{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T13:55:30Z","timestamp":1791640530121,"version":"4.3.4"},"reference-count":63,"publisher":"IOP Publishing","issue":"12","license":[{"start":{"date-parts":[[2015,5,28]],"date-time":"2015-05-28T00:00:00Z","timestamp":1432771200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2015,5,28]],"date-time":"2015-05-28T00:00:00Z","timestamp":1432771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Canadian Institutes for Health Research","award":["MOP-115101"],"award-info":[{"award-number":["MOP-115101"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2015,6,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Radiochromic leuco crystal violet (LCV) micelle gel dosimeters are promising three-dimensional radiation dosimeters because of their spatial stability and suitability for optical readout. The effects of surfactant type and surfactant concentration on dose sensitivity of LCV micelle gels are tested, demonstrating that dose sensitivity and initial colour of the gel increases with increasing Triton x-100 (Tx100) concentration. Using Cetyl Trimethyl Ammonium Bromide (CTAB) in place of Tx100 produces gels that are nearly colourless prior to irradiation, but reduces the dose sensitivity. The separate effects of Tri-chloro acetic acid concentration and pH are investigated, revealing that controlling the pH near 3.6 is crucial for achieving high dose sensitivity. The sensitizing effect of chlorinated species on dose sensitivity is tested using 2,2,2-trichloroethanol (TCE), chloroform, and 1,1,1-trichloro-2-methyl-2-propanol hemihydrate. TCE gives the largest improvement in dose sensitivity and is recommended for use in micelle gel dosimeters because it is less volatile and safer to use than chloroform. Preliminary experiments on a new gel containing CTAB as the surfactant and TCE show that this new gel gives a dose sensitivity that is 24% higher than that of previous LCV micelle gels and is nearly colourless prior to irradiation.<\/jats:p>","DOI":"10.1088\/0031-9155\/60\/12\/4665","type":"journal-article","created":{"date-parts":[[2015,5,28]],"date-time":"2015-05-28T09:13:22Z","timestamp":1432804402000},"page":"4665-4683","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":22,"title":["Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers"],"prefix":"10.1088","volume":"60","author":[{"given":"A T","family":"Nasr","sequence":"first","affiliation":[{"name":"Queen\u2019s University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K","family":"Alexander","sequence":"additional","affiliation":[{"name":"Queen\u2019s University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L J","family":"Schreiner","sequence":"additional","affiliation":[{"name":"Queen\u2019s University"},{"name":"Queen\u2019s University"},{"name":"Cancer Centre of Southeastern Ontario"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K B","family":"McAuley","sequence":"additional","affiliation":[{"name":"Queen\u2019s University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2015,5,28]]},"reference":[{"key":"pmb513832bib0001","article-title":"3D dosimeter for penetrating radiation and method of use","author":"Adamovics","year":"2006","type":"patent"},{"key":"pmb513832bib0002","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1093\/rpd\/nci555","type":"journal-article","article-title":"Charaterisation of PRESAGE: a new 3D radio chromic solid polymer dosimeter for ionizing radiation","volume":"120","author":"Adamovics","year":"2006","journal-title":"Radiat. Prot. Dosim."},{"key":"pmb513832bib0003","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1118\/1.596052","type":"journal-article","article-title":"Imaging of spatial radiation dose distribution in agarose gels using magnetic resonance","volume":"14","author":"Appleby","year":"1987","journal-title":"Med. Phys."},{"key":"pmb513832bib0004","doi-asserted-by":"publisher","first-page":"6791","DOI":"10.1088\/0031-9155\/54\/22\/003","type":"journal-article","article-title":"Radiochromic leuco dye micelle hydrogels: II. Low diffusion rate leuco crystal violet gel","volume":"54","author":"Babic","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0005","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/0031-9155\/55\/1\/001","type":"journal-article","article-title":"Polymer gel dosimetry","volume":"55","author":"Baldock","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0006","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1088\/0031-9155\/54\/2\/007","type":"journal-article","article-title":"Modelling optical scattering artefacts for varying pathlength in a gel dosimeter phantom","volume":"54","author":"Bosi","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0007","doi-asserted-by":"publisher","first-page":"2893","DOI":"10.1088\/0031-9155\/52\/10\/017","type":"journal-article","article-title":"Initial investigation of a novel light-scattering gel phantom for evaluation of optical CT scanners for radiotherapy gel dosimetry","volume":"52","author":"Bosi","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0008","doi-asserted-by":"publisher","first-page":"1970","DOI":"10.1016\/j.apradiso.2008.06.005","type":"journal-article","article-title":"Radiological properties of the PRESAGE and PAGAT polymer dosimeters","volume":"66","author":"Brown","year":"2008","journal-title":"Appl. Radiat. Isot."},{"key":"pmb513832bib0009","doi-asserted-by":"publisher","first-page":"4885","DOI":"10.1088\/0031-9155\/55\/17\/001","type":"journal-article","article-title":"RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation","volume":"55","author":"Ceberg","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0010","doi-asserted-by":"publisher","first-page":"2091","DOI":"10.1088\/0031-9155\/56\/7\/012","type":"journal-article","article-title":"Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response","volume":"56","author":"Chain","year":"2011a","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0011","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1002\/mats.201100032","type":"journal-article","article-title":"Mathematical modeling of depth-dose response of polymer-gel dosimeters","volume":"20","author":"Chain","year":"2011b","journal-title":"Macromol. Theory Simul."},{"key":"pmb513832bib0012","doi-asserted-by":"publisher","first-page":"10771","DOI":"10.1021\/la801705y","type":"journal-article","article-title":"Mechanism of surfactant micelle formation","volume":"24","author":"Cui","year":"2008","journal-title":"Langmuir"},{"key":"pmb513832bib0013","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1088\/1742-6596\/3\/1\/006","type":"journal-article","article-title":"Essential characteristics of polymer gel dosimeters","volume":"3","author":"De Deene","year":"2004","journal-title":"J. Phys.:Conf. Ser."},{"key":"pmb513832bib0014","doi-asserted-by":"publisher","first-page":"2459","DOI":"10.1088\/0031-9155\/47\/14\/307","type":"journal-article","article-title":"Dose\u2013response stability and integrity of the dose distribution of various polymer gel dosimeters","volume":"47","author":"De Deene","year":"2002a","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0015","doi-asserted-by":"publisher","first-page":"3441","DOI":"10.1088\/0031-9155\/47\/19\/301","type":"journal-article","article-title":"A basic study of some normoxic polymer gel dosimeters","volume":"47","author":"De Deene","year":"2002b","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0016","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/164\/1\/012020","type":"journal-article","article-title":"The history and principles of optical computed tomography for scanning 3-D radiation dosimeters: 2008 update","volume":"164","author":"Doran","year":"2009","journal-title":"J. Phys.:Conf. Ser."},{"key":"pmb513832bib0017","doi-asserted-by":"publisher","first-page":"16608","DOI":"10.1021\/jp960644m","type":"journal-article","article-title":"Size of sodium dodecyl sulfate micelles in aqueous solutions as studied by positron annihilation lifetime spectroscopy","volume":"100","author":"Duplatre","year":"1996","journal-title":"J. Phys. Chem."},{"key":"pmb513832bib0018","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/444\/1\/012027","type":"journal-article","article-title":"Basic investigations on LCV micelle gel","volume":"444","author":"Ebenezer","year":"2013","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmb513832bib0019","author":"Evans","year":"1999","edition":"2nd edn","type":"book"},{"key":"pmb513832bib0020","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1016\/j.ces.2004.09.079","type":"journal-article","article-title":"Modeling of polyacrylamide gel dosimeters with spatially non-uniform radiation dose distributions","volume":"60","author":"Fuxman","year":"2005","journal-title":"Chem. Eng. Sci."},{"key":"pmb513832bib0021","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1088\/0031-9155\/29\/10\/002","type":"journal-article","article-title":"Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging","volume":"29","author":"Gore","year":"1984","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0022","doi-asserted-by":"publisher","first-page":"1338","DOI":"10.1118\/1.2192888","type":"journal-article","article-title":"Characterization of a new radiochromic 3D dosimeter","volume":"33","author":"Guo","year":"2006","journal-title":"Med. Phys."},{"key":"pmb513832bib0023","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1016\/j.nima.2006.05.167","type":"journal-article","article-title":"High-resolution gel dosimetry of a HDR brachytherapy source using normoxic polymer gel dosimeters: preliminary study","volume":"565","author":"Hurley","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res A"},{"key":"pmb513832bib0024","doi-asserted-by":"publisher","first-page":"5269","DOI":"10.1088\/0031-9155\/55\/18\/002","type":"journal-article","article-title":"Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry","volume":"55","author":"Jirasek","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0025","doi-asserted-by":"publisher","first-page":"1891","DOI":"10.1088\/0031-9155\/51\/7\/018","type":"journal-article","article-title":"Investigation of tetrakis hydroxymethyl phosphonium chloride as an antioxidant for use in x-ray computed tomography polyacrylamide gel dosimetry","volume":"51","author":"Jirasek","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0026","author":"Jordan","year":"2013","type":"other"},{"key":"pmb513832bib0027","doi-asserted-by":"publisher","first-page":"6773","DOI":"10.1088\/0031-9155\/54\/22\/002","type":"journal-article","article-title":"Radiochromic leuco dye micelle hydrogels: I. initial investigation","volume":"54","author":"Jordan","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0028","doi-asserted-by":"publisher","first-page":"2779","DOI":"10.1088\/0031-9155\/54\/9\/013","type":"journal-article","article-title":"Preliminary investigation of the NMR, optical and x-ray CT dose\u2013response of polymer gel dosimeters incorporating cosolvents to improve dose sensitivity","volume":"54","author":"Koeva","year":"2009a","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0029","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1002\/mats.200900023","type":"journal-article","article-title":"Mathematical Modeling of PAG- and NIPAM Based Polymer Gel Dosimeters Contaminated by Oxygen and Inhibitor","volume":"18","author":"Koeva","year":"2009b","journal-title":"Macromol. Theory Simul."},{"key":"pmb513832bib0030","first-page":"645","type":"book","author":"Laidler","year":"2003","edition":"4th edn"},{"key":"pmb513832bib0031","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.radonc.2009.12.020","type":"journal-article","article-title":"3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry","volume":"94","author":"Mans","year":"2010","journal-title":"Radiother. Oncol."},{"key":"pmb513832bib0032","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/0730-725X(93)90030-H","type":"journal-article","article-title":"NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI","volume":"11","author":"Maryanski","year":"1993","journal-title":"Magn. Reson. Imaging"},{"key":"pmb513832bib0033","doi-asserted-by":"publisher","first-page":"1437","DOI":"10.1088\/0031-9155\/39\/9\/010","type":"journal-article","article-title":"Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter","volume":"39","author":"Maryanski","year":"1994","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0034","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1088\/1742-6596\/3\/1\/005","type":"journal-article","article-title":"The chemistry and physics of polyacrylamide gel dosimeters: why they do and don\u2019t work","volume":"3","author":"McAuley","year":"2004","journal-title":"J. Phys.:Conf. Ser."},{"key":"pmb513832bib0035","first-page":"p 129","type":"book","article-title":"Films, Dyes, and Photographic Systems","author":"McLaughlin","year":"1970"},{"key":"pmb513832bib0036","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/250\/1\/012020","type":"journal-article","article-title":"2D and 3D dose verification at the netherlands cancer institute-antoni van leeuwenhoek hospital using epids","volume":"250","author":"Mijnheer","year":"2010","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmb513832bib0037","doi-asserted-by":"publisher","first-page":"4685","DOI":"10.1088\/0031-9155\/60\/12\/4685","type":"journal-article","article-title":"Leuco-crystal-violet micelle gel dosimeters: II. Recipe optimization and testing","volume":"60","author":"Nasr","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0038","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1088\/0031-9155\/58\/4\/787","type":"journal-article","article-title":"Evaluation of the potential for diacetylenes as reporter molecules in 3D micelle gel dosimetry","volume":"58","author":"Nasr","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0039","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1002\/mats.201100057","type":"journal-article","article-title":"Mathematical modeling of the response of polymer gel dosimeters to HDR and LDR brachytherapy radiation","volume":"21","author":"Nasr","year":"2012","journal-title":"Macromol. Theory Simul."},{"key":"pmb513832bib0040","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.meddos.2012.07.004","type":"journal-article","article-title":"Delivery quality assurance with ArcCHECK","volume":"38","author":"Neilson","year":"2013","journal-title":"Med. Dosim."},{"key":"pmb513832bib0041","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1016\/0076-6879(90)82020-3","type":"journal-article","article-title":"Detergents: an overview","volume":"182","author":"Neugebauer","year":"1990","journal-title":"Methods Enzymol."},{"key":"pmb513832bib0042","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1118\/1.1655710","type":"journal-article","article-title":"Optical-CT gel-dosimetry: II. Optical artifacts and geometrical distortion","volume":"31","author":"Oldham","year":"2004","journal-title":"Med. Phys."},{"key":"pmb513832bib0043","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1118\/1.1559835","type":"journal-article","article-title":"Optical-CT gel-dosimetry I: basic investigations","volume":"30","author":"Oldham","year":"2003","journal-title":"Med. Phys."},{"key":"pmb513832bib0044","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/444\/1\/012073","type":"journal-article","article-title":"Stereotactic body radiation therapy delivery validation","volume":"444","author":"Olding","year":"2013","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmb513832bib0045","doi-asserted-by":"publisher","first-page":"3","DOI":"10.4103\/0971-6203.75466","type":"journal-article","article-title":"Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry","volume":"36","author":"Olding","year":"2011","journal-title":"J. Med. Phys."},{"key":"pmb513832bib0046","doi-asserted-by":"publisher","first-page":"2819","DOI":"10.1088\/0031-9155\/55\/10\/003","type":"journal-article","article-title":"Cone beam optical computed tomography for geldosimetry I: scanner characterization","volume":"55","author":"Olding","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0047","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/164\/1\/012060","type":"journal-article","article-title":"On the role of polymer gels in the dosimetry of small photon fields used in radiotherapy","volume":"164","author":"Pappas","year":"2009","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmb513832bib0048","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1021\/j100443a008","type":"journal-article","article-title":"Shape and size of a nonionic surfactant micelle. Triton x-100 in aqueous solution","volume":"84","author":"Paradies","year":"1980","journal-title":"J. Phys. Chem."},{"key":"pmb513832bib0049","doi-asserted-by":"publisher","first-page":"1823","DOI":"10.1088\/0031-9155\/58\/6\/1823","type":"journal-article","article-title":"Controlling sensitivity and stability of ferrous-xylenol orange-gelatin 3D gel dosimeters by doping with phenanthroline-type ligands and glyoxal","volume":"58","author":"Penev","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0050","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1088\/1742-6596\/3\/1\/003","type":"journal-article","article-title":"Review of Fricke gel dosimeters","volume":"3","author":"Schreiner","year":"2004","journal-title":"J. Physics. Conf. Ser."},{"key":"pmb513832bib0051","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/164\/1\/012001","type":"journal-article","article-title":"where does gel dosimetry fit in the clinic?","volume":"164","author":"Schreiner","year":"2009","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmb513832bib0052","doi-asserted-by":"publisher","first-page":"189","DOI":"10.4103\/0971-6203.89963","type":"journal-article","article-title":"on the quality assurance and verification of modern radiation therapy treatment","volume":"36\u20134","author":"Schreiner","year":"2011","journal-title":"J. Med. Phys."},{"key":"pmb513832bib0053","first-page":"197","type":"other","article-title":"Development of in-house process QA in modern radiation therapy","volume":"vol 2","author":"Schreiner","year":"2011"},{"key":"pmb513832bib0054","article-title":"Leucocrystal violet, cas registry number: 603-48-5","author":"SciFinder website","year":"2013","type":"web-resource"},{"key":"pmb513832bib0055","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1088\/0031-9155\/56\/3\/006","type":"journal-article","article-title":"Severe dose inaccuracies caused by an oxygen-antioxidant imbalance in normoxic polymer gel dosimeters","volume":"56","author":"Sedaghat","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0056","doi-asserted-by":"publisher","first-page":"3301","DOI":"10.1088\/0031-9155\/51\/14\/001","type":"journal-article","article-title":"Polymer gel dosimeters with reduced toxicity: a preliminary investigation of the NMR and optical dose\u2013response using different monomers","volume":"51","author":"Senden","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0057","article-title":"MSDS for chloroform, 2,2,2-Trichloroethanol and 1,1,1-Trichloro-2-methyl-2-propanol hemihydrate","author":"Sigma-Aldrich","year":"2013","type":"web-resource"},{"key":"pmb513832bib0058","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/444\/1\/012036","type":"journal-article","article-title":"Exploring the dose response of radiochromic dosimeters","volume":"444","author":"Skyt","year":"2013a","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmb513832bib0059","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/444\/1\/012038","type":"journal-article","article-title":"Diffusion properties of a radiochromic hydrogel dosimeter","volume":"444","author":"Skyt","year":"2013b","journal-title":"J. Phys: Conf. Ser."},{"key":"pmb513832bib0060","doi-asserted-by":"publisher","first-page":"11582","DOI":"10.1021\/la402415b","type":"journal-article","article-title":"Molecular dynamics simulation of sds and ctab micellization and prediction of partition equilibria with cosmomic","volume":"29","author":"Storm","year":"2013","journal-title":"Langmuir"},{"key":"pmb513832bib0061","doi-asserted-by":"publisher","first-page":"6241","DOI":"10.1088\/0031-9155\/58\/18\/6241","type":"journal-article","article-title":"Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification","volume":"58","author":"Vandecasteele","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0062","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1088\/0031-9155\/56\/3\/007","type":"journal-article","article-title":"Radio-physical properties of micelle leucodye 3D integrating gel dosimeters","volume":"56","author":"Vandecasteele","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"pmb513832bib0063","doi-asserted-by":"publisher","first-page":"4507","DOI":"10.1088\/0031-9155\/49\/19\/005","type":"journal-article","article-title":"On the relation between the spatial dose integrity and the temporal instability of polymer gel dosimeters","volume":"49","author":"Vergote","year":"2004","journal-title":"Phys. Med. Biol."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=12\/a=4665\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=12\/a=4665?key=crossref.685534452654e0e478e483d835a481f9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/12\/4665","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/12\/4665\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/12\/4665\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=12\/a=4665\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=12\/a=4665?key=crossref.685534452654e0e478e483d835a481f9","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/12\/4665\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T13:44:02Z","timestamp":1791639842000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/12\/4665"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,5,28]]},"references-count":63,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2015,5,28]]},"published-print":{"date-parts":[[2015,6,21]]}},"URL":"https:\/\/doi.org\/10.1088\/0031-9155\/60\/12\/4665","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,5,28]]},"assertion":[{"value":"Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2015 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2014-06-25","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-04-27","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-05-28","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}