{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T13:51:13Z","timestamp":1791640273005,"version":"4.3.4"},"reference-count":23,"publisher":"IOP Publishing","issue":"22","license":[{"start":{"date-parts":[[2015,11,3]],"date-time":"2015-11-03T00:00:00Z","timestamp":1446508800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2015,11,3]],"date-time":"2015-11-03T00:00:00Z","timestamp":1446508800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2015,11,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Parallel-hole SPECT collimators have traditionally been manufactured by stacking sheets of lead foil or by casting. These techniques significantly restrict our options in terms of collimator geometry. However, recent developments in metal additive manufacturing are making novel collimator designs possible, giving rise to new opportunities in SPECT imaging. In this paper we propose an innovative type of collimator for stationary SPECT, using parallel-holes whose collimation direction depends on their axial position. Its main advantage compared to current stationary SPECT systems (which are based on pinholes) is that, using only axial bed translations, we can achieve complete angular sampling of an increased portion of the transaxial area of the collimator bore. This allows the system to be much more compact than current stationary SPECT systems that image objects of the same size. We describe three possible designs, for full-body, brain and small-animal imaging, respectively, and test their feasibility using simulations. The system modeling method is validated against realistic Monte Carlo simulations, and then used in the evaluation of the systems\u2019 performances and reconstructions. The simulations show that the system is able to reconstruct objects occupying the predicted field of view (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      \n                    <\/jats:inline-formula>\n                    of the transaxial area of the bore) without sampling artifacts. In particular, we perform reconstructions from noisy projection data obtained for an activity and scanning time similar to standard protocols for the three applications, and the resulting images indicate the possibility of using the proposed systems in practice.\n                  <\/jats:p>","DOI":"10.1088\/0031-9155\/60\/22\/8791","type":"journal-article","created":{"date-parts":[[2015,11,3]],"date-time":"2015-11-03T12:44:55Z","timestamp":1446554695000},"page":"8791-8807","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Parallel-hole collimator concept for stationary SPECT imaging"],"prefix":"10.1088","volume":"60","author":[{"given":"Lara R V","family":"Pato","sequence":"first","affiliation":[{"name":"Ghent University-iMinds-IBiTech"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefaan","family":"Vandenberghe","sequence":"additional","affiliation":[{"name":"Ghent University-iMinds-IBiTech"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiziana","family":"Zedda","sequence":"additional","affiliation":[{"name":"Ghent University-iMinds-IBiTech"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roel","family":"Van Holen","sequence":"additional","affiliation":[{"name":"Ghent University-iMinds-IBiTech"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2015,11,3]]},"reference":[{"key":"pmb520939bib001","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/B978-0-12-349450-4.50025-2","type":"book","article-title":"Radioisotope cameras","author":"Anger","year":"1967"},{"key":"pmb520939bib002","author":"Barrett","year":"1996","type":"book"},{"key":"pmb520939bib003","first-page":"1194","type":"journal-article","article-title":"U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice","volume":"46","author":"Beekman","year":"2005","journal-title":"J. Nucl. Med."},{"key":"pmb520939bib004","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1088\/0031-9155\/57\/3\/717","type":"journal-article","article-title":"Murine cardiac images obtained with focusing pinhole SPECT are barely influenced by extra-cardiac activity","volume":"57","author":"Branderhorst","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmb520939bib005","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1007\/s002590050153","type":"journal-article","article-title":"Quantification of diphosphonate uptake based on conventional bone scanning","volume":"24","author":"Brenner","year":"1997","journal-title":"Eur. J. Nucl. Med."},{"key":"pmb520939bib006","first-page":"259","type":"journal-article","article-title":"Brain SPECT in clinical practice. part I: perfusion","volume":"42","author":"Catafau","year":"2001","journal-title":"J. Nucl. Med."},{"key":"pmb520939bib007","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1007\/0-387-25294-0_12","type":"book","article-title":"Calibration of scintillation cameras and pinhole SPECT imaging systems","author":"Chen","year":"2005"},{"key":"pmb520939bib008","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1088\/0031-9155\/58\/4\/859","type":"journal-article","article-title":"Characterization of a SPECT pinhole collimator for optimal detector usage (the lofthole)","volume":"58","author":"Deprez","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmb520939bib009","doi-asserted-by":"publisher","first-page":"012501-1","DOI":"10.1118\/1.4769122","type":"journal-article","article-title":"Rapid additive manufacturing of MR compatible multipinhole collimators with selective laser melting of tungsten powder","volume":"40","author":"Deprez","year":"2013a","journal-title":"Med. Phys."},{"key":"pmb520939bib010","first-page":"2165","type":"journal-article","article-title":"Accuracy and density of pure tungsten collimators produced by additive manufacturing","volume":"54","author":"Deprez","year":"2013b","journal-title":"J. Nucl. Med."},{"key":"pmb520939bib011","first-page":"595","type":"journal-article","article-title":"A novel approach to multipinhole SPECT for myocardial perfusion imaging","volume":"47","author":"Funk","year":"2006","journal-title":"J. Nucl. Med."},{"key":"pmb520939bib012","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1109\/TNS.2004.830975","type":"journal-article","article-title":"FastSPECT II: a second-generation high-resolution dynamic SPECT imager","volume":"51","author":"Furenlid","year":"2004","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmb520939bib013","doi-asserted-by":"publisher","first-page":"4543","DOI":"10.1088\/0031-9155\/49\/19\/007","type":"journal-article","article-title":"Gate: a simulation toolkit for PET and SPECT","volume":"49","author":"Jan","year":"2004","journal-title":"Phys. Med. Biol."},{"key":"pmb520939bib014","first-page":"931","type":"journal-article","article-title":"FASTSPECT: electrical and mechanical design of a high-resolution dynamic SPECT imager","volume":"vol 2","author":"Klein","year":"1995","journal-title":"IEEE NSS\/MIC Conf. Record"},{"key":"pmb520939bib015","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/NSSMIC.2013.6829175","type":"journal-article","article-title":"Artificial compound-eye gamma camera for MRI compatible SPECT imaging","author":"Lai","year":"2013","journal-title":"IEEE NSS\/MIC Conf. Record"},{"key":"pmb520939bib016","first-page":"4004","type":"journal-article","article-title":"System integration of FastSPECT III, a dedicated SPECT rodent-brain imager based on BazookaSPECT detector technology","author":"Miller","year":"2009","journal-title":"IEEE NSS\/MIC Conf. Record"},{"key":"pmb520939bib017","doi-asserted-by":"publisher","first-page":"6153","DOI":"10.1088\/0031-9155\/59\/20\/6153","type":"journal-article","article-title":"Continuous bed motion on clinical scanner: design, data correction, and reconstruction","volume":"59","author":"Panin","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmb520939bib018","article-title":"Analytical modeling of collimator response for a compact stationary parallel-hole spect system","author":"Pato","year":"2015","type":"conference-proceedings"},{"key":"pmb520939bib019","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.mibio.2004.03.002","type":"journal-article","article-title":"Development of a 4D digital mouse phantom for molecular imaging research","volume":"6","author":"Segars","year":"2004","journal-title":"Mol. Imaging Biol."},{"key":"pmb520939bib020","first-page":"1954","type":"journal-article","article-title":"MCAT to XCAT: the evolution of 4D computerized phantoms for imaging research","author":"Segars","year":"2009","journal-title":"IEEE NSS\/MIC Conf. Record"},{"key":"pmb520939bib021","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1088\/0031-9155\/54\/2\/003","type":"journal-article","article-title":"Multi-pinhole collimator design for small-object imaging with SiliSPECT: a high-resolution SPECT","volume":"54","author":"Shokouhi","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmb520939bib022","doi-asserted-by":"publisher","first-page":"599","DOI":"10.2967\/jnumed.108.056606","type":"journal-article","article-title":"U-SPECT-II: an ultra-high-resolution device for molecular small-animal imaging","volume":"50","author":"van der Have","year":"2009","journal-title":"J. Nucl. Med."},{"key":"pmb520939bib023","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1088\/0031-9155\/38\/10\/005","type":"journal-article","article-title":"CERASPECT: a brain-dedicated SPECT system. Performance evaluation and comparison with the rotating gamma camera","volume":"38","author":"Zito","year":"1993","journal-title":"Phys. Med. Biol."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=22\/a=8791\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=22\/a=8791?key=crossref.d2cffdf39bca6a5a0c1cd982e0c61f20","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/22\/8791","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/22\/8791\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/22\/8791\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=22\/a=8791\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=22\/a=8791?key=crossref.d2cffdf39bca6a5a0c1cd982e0c61f20","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/22\/8791\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T13:05:04Z","timestamp":1791637504000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/22\/8791"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,3]]},"references-count":23,"journal-issue":{"issue":"22","published-online":{"date-parts":[[2015,11,3]]},"published-print":{"date-parts":[[2015,11,21]]}},"URL":"https:\/\/doi.org\/10.1088\/0031-9155\/60\/22\/8791","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,3]]},"assertion":[{"value":"Parallel-hole collimator concept for stationary SPECT imaging","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2015 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2015-07-23","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-10-08","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-11-03","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}