{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,15]],"date-time":"2026-11-15T01:18:24Z","timestamp":1794705504850,"version":"4.9.1"},"reference-count":48,"publisher":"IOP Publishing","issue":"8","license":[{"start":{"date-parts":[[2015,3,31]],"date-time":"2015-03-31T00:00:00Z","timestamp":1427760000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2015,3,31]],"date-time":"2015-03-31T00:00:00Z","timestamp":1427760000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2015,4,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Depth and radial dose profiles for therapeutic\n                    <jats:sup>1<\/jats:sup>\n                    H,\n                    <jats:sup>4<\/jats:sup>\n                    He,\n                    <jats:sup>12<\/jats:sup>\n                    C and\n                    <jats:sup>16<\/jats:sup>\n                    O beams are calculated using the Geant4-based Monte Carlo model for Heavy-Ion Therapy (MCHIT).\n                    <jats:sup>4<\/jats:sup>\n                    He and\n                    <jats:sup>16<\/jats:sup>\n                    O ions are presented as alternative options to\n                    <jats:sup>1<\/jats:sup>\n                    H and\n                    <jats:sup>12<\/jats:sup>\n                    C broadly used for ion-beam cancer therapy. Biological dose profiles and survival fractions of cells are estimated using the modified Microdosimetric Kinetic model. Depth distributions of cell survival of healthy tissues, assuming 10% and 50% survival of tumor cells, are calculated for 6\u00a0cm SOBPs at two tumor depths and for different tissues radiosensitivities. It is found that the optimal ion choice depends on (i) depth of the tumor, (ii) dose levels and (iii) the contrast of radiosensitivities of tumor and surrounding healthy tissues. Our results indicate that\n                    <jats:sup>12<\/jats:sup>\n                    C and\n                    <jats:sup>16<\/jats:sup>\n                    O ions are more appropriate to spare healthy tissues in the case of a more radioresistant tumor at moderate depths. On the other hand, a sensitive tumor surrounded by more resistant tissues can be better treated with\n                    <jats:sup>1<\/jats:sup>\n                    H and\n                    <jats:sup>4<\/jats:sup>\n                    He ions. In general,\n                    <jats:sup>4<\/jats:sup>\n                    He beam is found to be a good candidate for therapy. It better spares healthy tissues in all considered cases compared to\n                    <jats:sup>1<\/jats:sup>\n                    H. Besides, the dose conformation is improved for deep-seated tumors compared to\n                    <jats:sup>1<\/jats:sup>\n                    H, and the damage to surrounding healthy tissues is reduced compared to heavier ions due to the lower impact of nuclear fragmentation. No definite advantages of\n                    <jats:sup>16<\/jats:sup>\n                    O with respect to\n                    <jats:sup>12<\/jats:sup>\n                    C ions are found in this study.\n                  <\/jats:p>","DOI":"10.1088\/0031-9155\/60\/8\/3313","type":"journal-article","created":{"date-parts":[[2015,3,31]],"date-time":"2015-03-31T18:13:11Z","timestamp":1427825591000},"page":"3313-3331","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":27,"title":["Comparative study of dose distributions and cell survival fractions for\n                    <sup>1<\/sup>\n                    H,\n                    <sup>4<\/sup>\n                    He,\n                    <sup>12<\/sup>\n                    C and\n                    <sup>16<\/sup>\n                    O beams using Geant4 and Microdosimetric Kinetic model"],"prefix":"10.1088","volume":"60","author":[{"given":"Lucas","family":"Burigo","sequence":"first","affiliation":[{"name":"Frankfurt Institute for Advanced Studies, Johann Wolfgang Goethe University"},{"name":"Institut f\u00fcr Theoretische Physik, Johann Wolfgang Goethe University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Igor","family":"Pshenichnov","sequence":"additional","affiliation":[{"name":"Frankfurt Institute for Advanced Studies, Johann Wolfgang Goethe University"},{"name":"Institute for Nuclear Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Igor","family":"Mishustin","sequence":"additional","affiliation":[{"name":"Frankfurt Institute for Advanced Studies, Johann Wolfgang Goethe University"},{"name":"Kurchatov Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Bleicher","sequence":"additional","affiliation":[{"name":"Frankfurt Institute for Advanced Studies, Johann Wolfgang Goethe University"},{"name":"Institut f\u00fcr Theoretische Physik, Johann Wolfgang Goethe University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2015,3,31]]},"reference":[{"key":"pmb510532bib001","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/S0168-9002(03)01368-8","type":"journal-article","article-title":"Geant4\u2009:\u2009a simulation toolkit","volume":"506","author":"Agostinelli","year":"2003","journal-title":"Nucl. Instrum. Methods A"},{"key":"pmb510532bib002","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1109\/TNS.2006.869826","type":"journal-article","article-title":"Geant4 developments and applications","volume":"53","author":"Allison","year":"2006","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmb510532bib003","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/0370-1573(94)00097-M","type":"journal-article","article-title":"Statistical multifragmentation of nuclei","volume":"257","author":"Bondorf","year":"1995","journal-title":"Phys. Rep."},{"key":"pmb510532bib004","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/S0168-583X(01)00781-9","type":"journal-article","article-title":"Design of a centre for biologically optimised light ion therapy in Stockholm","volume":"184","author":"Brahme","year":"2001","journal-title":"Nucl. Instrum. Methods B"},{"key":"pmb510532bib005","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.nimb.2013.05.021","type":"journal-article","article-title":"Microdosimetry of radiation field from a therapeutic 12C beam in water: a study with Geant4 toolkit","volume":"310","author":"Burigo","year":"2013a","journal-title":"Nucl. Instrum. Methods B"},{"key":"pmb510532bib006","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/426\/1\/012006","type":"journal-article","article-title":"Monte Carlo simulations of microdosimetry for space research at FAIR","volume":"426","author":"Burigo","year":"2013b","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmb510532bib007","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.nimb.2013.10.018","type":"journal-article","article-title":"Microdosimetry spectra and RBE of 1H, 4He, 7Li and 12C nuclei in water studied with Geant4","volume":"320","author":"Burigo","year":"2014","journal-title":"Nucl. Instrum. Methods B"},{"key":"pmb510532bib008","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/0360-3016(77)90234-6","type":"journal-article","article-title":"Radiobiological characterization of the inactivating events produced in mammalian cells by helium and heavy ions","volume":"3","author":"Chapman","year":"1977","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmb510532bib009","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.radonc.2010.02.016","type":"journal-article","article-title":"Particle therapy at the Heidelberg ion therapy center (HIT)\u2014Integrated research-driven university-hospital-based radiation oncology service in Heidelberg, Germany","volume":"95","author":"Combs","year":"2010","journal-title":"Radiother. Oncol."},{"key":"pmb510532bib010","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1038\/nrclinonc.2009.183","type":"journal-article","article-title":"Charged particles in radiation oncology","volume":"7","author":"Durante","year":"2010","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"pmb510532bib011","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1667\/RR0467.1","type":"journal-article","article-title":"Cluster effects within the local effect model","volume":"167","author":"Els\u00e4sser","year":"2007","journal-title":"Radiat. Res."},{"key":"pmb510532bib012","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1140\/epja\/i2003-10219-7","type":"journal-article","article-title":"The binary cascade","volume":"21","author":"Folger","year":"2004","journal-title":"Eur. Phys. J. A"},{"key":"pmb510532bib013","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1007\/s00411-010-0298-9","type":"journal-article","article-title":"Accuracy of RBE: experimental and theoretical considerations","volume":"49","author":"Friedrich","year":"2010","journal-title":"Radiat. Environ. Biophys."},{"key":"pmb510532bib014","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1667\/0033-7587(2000)154[0485:IOAAHC]2.0.CO;2","type":"journal-article","article-title":"Inactivation of aerobic and hypoxic cells from three different cell lines by accelerated He-3-,C-12- and Ne-20-ion beams","volume":"154","author":"Furusawa","year":"2000","journal-title":"Radiat. Res."},{"key":"pmb510532bib015","doi-asserted-by":"publisher","first-page":"A97","DOI":"10.1269\/jrr.48.A97","type":"journal-article","article-title":"Comparison of the methods of specifying carbon ion doses at NIRS and GSI","volume":"48","author":"Gueulette","year":"2007","journal-title":"J. Radiat. Res."},{"key":"pmb510532bib016","doi-asserted-by":"publisher","first-page":"S186","DOI":"10.1016\/S0167-8140(04)80046-X","type":"journal-article","article-title":"The Heidelberg ion therapy center","volume":"73","author":"Haberer","year":"2004","journal-title":"Radiother. Oncol."},{"key":"pmb510532bib017","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1667\/RR3010","type":"journal-article","article-title":"A microdosimetric-kinetic model for the effect of non-Poisson distribution of lethal lesions on the variation of RBE with LET","volume":"160","author":"Hawkins","year":"2003","journal-title":"Radiat. Res."},{"key":"pmb510532bib018","article-title":"Microdosimetry","author":"ICRU","year":"1983","type":"report"},{"key":"pmb510532bib019","doi-asserted-by":"publisher","first-page":"6721","DOI":"10.1088\/0031-9155\/55\/22\/008","type":"journal-article","article-title":"Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model","volume":"55","author":"Inaniwa","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmb510532bib020","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.1088\/0031-9155\/46\/4\/314","type":"journal-article","article-title":"Treatment planning for heavy ion radiotherapy: clinical implementation and application","volume":"46","author":"J\u00e4kel","year":"2001","journal-title":"Phys. Med. Biol."},{"key":"pmb510532bib021","doi-asserted-by":"publisher","first-page":"S35","DOI":"10.1259\/bjr\/71511359","type":"journal-article","article-title":"Review of clinical experience with ion beam radiotherapy","volume":"84","author":"Jensen","year":"2011","journal-title":"Br. J. Radiol."},{"key":"pmb510532bib022","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1007\/s10147-012-0388-6","type":"journal-article","article-title":"Clinical evidence of particle beam therapy (carbon)","volume":"17","author":"Kamada","year":"2012","journal-title":"Int. J. Clin. Oncol."},{"key":"pmb510532bib023","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/S0360-3016(98)00544-6","type":"journal-article","article-title":"Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy","volume":"44","author":"Kanai","year":"1999","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmb510532bib024","doi-asserted-by":"publisher","first-page":"6585","DOI":"10.1118\/1.3662911","type":"journal-article","article-title":"Dose and dose averaged LET comparison of H-1, He-4, Li-6, Be-8, B-10, C-12, N-14 and O-16 ion beams forming a spread-out Bragg peak","volume":"38","author":"Kantemiris","year":"2011","journal-title":"Med. Phys."},{"key":"pmb510532bib048","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1269\/jrr.11044","type":"journal-article","article-title":"Preliminary calculation of RBE-weighted dose distribution for cerebral radionecrosis in carbon-ion treatment planning","volume":"52","author":"Kase","year":"2011","journal-title":"J. Radiat. Res."},{"key":"pmb510532bib025","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1667\/RR0536.1","type":"journal-article","article-title":"Microdosimetric measurements and estimation of human cell survival for heavy-ion beams","volume":"166","author":"Kase","year":"2006a","journal-title":"Radiat. Res."},{"key":"pmb510532bib026","doi-asserted-by":"publisher","first-page":"N467","DOI":"10.1088\/0031-9155\/51\/24\/N03","type":"journal-article","article-title":"Biological dose calculation with Monte Carlo physics simulation for heavy-ion radiotherapy","volume":"51","author":"Kase","year":"2006b","journal-title":"Phys. Med. Biol."},{"key":"pmb510532bib027","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1118\/1.2400621","type":"journal-article","article-title":"Depth absorbed dose and LET distributions of therapeutic H-1, He-4, Li-7 and C-12 beams","volume":"34","author":"Kempe","year":"2007","journal-title":"Med. Phys."},{"key":"pmb510532bib028","article-title":"New native QMD code in Geant4","author":"Koi","year":"2010","type":"conference-proceedings"},{"key":"pmb510532bib029","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1140\/epjd\/e2010-00077-8","type":"journal-article","article-title":"Ion beam transport calculations and treatment plans in particle therapy","volume":"60","author":"Kr\u00e4mer","year":"2010","journal-title":"Eur. Phys. J. D"},{"key":"pmb510532bib030","doi-asserted-by":"publisher","first-page":"3299","DOI":"10.1088\/0031-9155\/45\/11\/313","type":"journal-article","article-title":"Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization","volume":"45","author":"Kr\u00e4mer","year":"2000","journal-title":"Phys. Med. Biol."},{"key":"pmb510532bib031","doi-asserted-by":"publisher","first-page":"3319","DOI":"10.1088\/0031-9155\/45\/11\/314","type":"journal-article","article-title":"Treatment planning for heavy-ion radiotherapy: calculation and optimization of biologically effective dose","volume":"45","author":"Kr\u00e4mer","year":"2000","journal-title":"Phys. Med. Biol."},{"key":"pmb510532bib032","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1080\/02841860500341157","type":"journal-article","article-title":"Proton therapy of cancer: Potential clinical advantages and cost-effectiveness","volume":"44","author":"Lundkvist","year":"2005","journal-title":"Acta. Oncol."},{"key":"pmb510532bib033","doi-asserted-by":"publisher","first-page":"3441","DOI":"10.1088\/0031-9155\/55\/12\/011","type":"journal-article","article-title":"Microdosimetry measurements characterizing the radiation fields of 300\u00a0MeV\u00a0u\u22121 12C and 185\u00a0MeV\u00a0u\u22121 7Li pencil beams stopping in water","volume":"55","author":"Martino","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmb510532bib034","doi-asserted-by":"publisher","first-page":"A81","DOI":"10.1269\/jrr.48.A81","type":"journal-article","article-title":"Specification of carbon ion dose at the National Institute of Radiological Sciences (NIRS)","volume":"48","author":"Matsufuji","year":"2007","journal-title":"J. Radiat. Res."},{"key":"pmb510532bib035","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1016\/j.nimb.2009.12.023","type":"journal-article","article-title":"Nuclear fragmentation reactions in extended media studied with Geant4 toolkit","volume":"268","author":"Pshenichnov","year":"2010","journal-title":"Nucl. Instrum. Methods B"},{"key":"pmb510532bib036","doi-asserted-by":"publisher","first-page":"5493","DOI":"10.1088\/0031-9155\/50\/23\/005","type":"journal-article","article-title":"Neutrons from fragmentation of light nuclei in tissue-like media: a study with the Geant4 toolkit","volume":"50","author":"Pshenichnov","year":"2005","journal-title":"Phys. Med. Biol."},{"key":"pmb510532bib037","doi-asserted-by":"publisher","first-page":"1094","DOI":"10.1016\/j.nimb.2008.02.025","type":"journal-article","article-title":"Comparative study of depth-dose distributions for beams of light and heavy nuclei in tissue-like media","volume":"266","author":"Pshenichnov","year":"2008","journal-title":"Nucl. Instrum. Methods B"},{"key":"pmb510532bib038","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1016\/j.ijrobp.2011.08.006","type":"journal-article","article-title":"Optimizing normal tissue sparing in ion therapy using calculated isoeffective dose for ion selection","volume":"83","author":"Remmes","year":"2012","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmb510532bib039","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1103\/RevModPhys.82.383","type":"journal-article","article-title":"Heavy-ion tumor therapy: physical and radiobiological benefits","volume":"82","author":"Schardt","year":"2010","journal-title":"Rev. Mod. Phys."},{"key":"pmb510532bib040","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/0273-1177(95)00784-C","type":"journal-article","article-title":"Track structure and the calculation of biological effects of heavy charged particles","volume":"18","author":"Scholz","year":"1996","journal-title":"Adv. Space Res."},{"key":"pmb510532bib041","doi-asserted-by":"publisher","first-page":"953","DOI":"10.1200\/JCO.2006.09.7816","type":"journal-article","article-title":"Particle radiation therapy using proton and heavier ion beams","volume":"25","author":"Schulz-Ertner","year":"2007","journal-title":"J. Clin. Oncol."},{"key":"pmb510532bib042","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.radonc.2010.01.015","type":"journal-article","article-title":"Proton versus carbon ion beams in the definitive radiation treatment of cancer patients","volume":"95","author":"Suit","year":"2010","journal-title":"Radiother. Oncol."},{"key":"pmb510532bib043","doi-asserted-by":"publisher","first-page":"S206","DOI":"10.1016\/S0167-8140(04)80049-5","type":"journal-article","article-title":"Development of light ion therapy at the Karolinska Hospital and Institute","volume":"73","author":"Svensson","year":"2004","journal-title":"Radiother. Oncol."},{"key":"pmb510532bib044","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1269\/jrr.11135","type":"journal-article","article-title":"Systematic measurement of lineal energy distributions for proton, He and Si ion beams over a wide energy range using a wall-less tissue equivalent proportional counter","volume":"53","author":"Tsuda","year":"2012","journal-title":"J. Radiat. Res."},{"key":"pmb510532bib045","doi-asserted-by":"publisher","first-page":"S41","DOI":"10.1016\/S0167-8140(04)80012-4","type":"journal-article","article-title":"Overview of clinical experiences on carbon ion radiotherapy at NIRS","volume":"73","author":"Tsujii","year":"2004","journal-title":"Radiother. Oncol."},{"key":"pmb510532bib046","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.ijrobp.2007.08.029","type":"journal-article","article-title":"Direct comparison of biologically optimized spread-out Bragg peaks for protons and carbon ions","volume":"70","author":"Wilkens","year":"2008","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmb510532bib047","doi-asserted-by":"publisher","first-page":"732","DOI":"10.2307\/3575352","type":"journal-article","article-title":"The synergistic effects of different radiations","volume":"83","author":"Zaider","year":"1980","journal-title":"Radiat. Res."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=8\/a=3313\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=8\/a=3313?key=crossref.974c3cec7e34d9f17b45f9397eddf4a6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/8\/3313","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/8\/3313\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/8\/3313\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=8\/a=3313\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/60\/i=8\/a=3313?key=crossref.974c3cec7e34d9f17b45f9397eddf4a6","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/8\/3313\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T13:40:58Z","timestamp":1791639658000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0031-9155\/60\/8\/3313"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3,31]]},"references-count":48,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2015,3,31]]},"published-print":{"date-parts":[[2015,4,21]]}},"URL":"https:\/\/doi.org\/10.1088\/0031-9155\/60\/8\/3313","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,3,31]]},"assertion":[{"value":"Comparative study of dose distributions and cell survival fractions for\n                      1\n                      H,\n                      4\n                      He,\n                      12\n                      C and\n                      16\n                      O beams using Geant4 and Microdosimetric Kinetic model","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2015 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2014-12-17","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-02-17","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-03-31","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}