{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T06:28:39Z","timestamp":1791440919719,"version":"4.3.3"},"reference-count":19,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2016,3,15]],"date-time":"2016-03-15T00:00:00Z","timestamp":1458000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2016,3,15]],"date-time":"2016-03-15T00:00:00Z","timestamp":1458000000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2016,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>With the objective of reducing patient exposure to radiation, we conducted a questionnaire survey regarding radiographic conditions in 2014. Here we report estimates of dose exposure in general radiography and mammography through an investigation and comparison of present patient exposure conditions. Questionnaires were sent to 3000 facilities nationwide in Japan. Surveys asked questions on a total of 16 items related to general radiography, including the chest, abdomen, and breast. Output data from x-ray tubes measured in the Chubu area of Japan were used as the mean in these estimates. The index of patient exposure was adopted as the entrance skin dose (ESD) for general radiography and as the mean glandular dose (MGD) for mammography. The response rate for this survey was 21.9%. Our results showed that doses received through the use of flat-panel detector (FPD) devices were lower than those received through computed radiography devices, except for the ankle joint (e.g. in chest examination, the dose from FPD and CR was 0.24 mGy, 0.31 mGy on the average, respectively). These results suggest that more widespread use of FPD devices could lead to decreases in the ESD and MGD, thereby reducing patient exposure.<\/jats:p>","DOI":"10.1088\/0952-4746\/36\/2\/n8","type":"journal-article","created":{"date-parts":[[2016,3,15]],"date-time":"2016-03-15T08:13:39Z","timestamp":1458029619000},"page":"N8-N18","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":16,"title":["Survey of patient exposure from general radiography and mammography in Japan in 2014"],"prefix":"10.1088","volume":"36","author":[{"given":"Y","family":"Asada","sequence":"first","affiliation":[{"name":"Fujita Health University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Fujita Health University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K","family":"Minami","sequence":"additional","affiliation":[{"name":"Fujita Health University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S","family":"Shirakawa","sequence":"additional","affiliation":[{"name":"Fujita Health University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M","family":"Kobayashi","sequence":"additional","affiliation":[{"name":"Fujita Health University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2016,3,15]]},"reference":[{"key":"jrpaa0c39bib001","first-page":"473","type":"journal-article","article-title":"Patient exposure doses during diagnostic radiography","volume":"44","author":"Suzuki","year":"2001","journal-title":"JMAJ"},{"key":"jrpaa0c39bib002","first-page":"1589","type":"journal-article","article-title":"Analysis on patient exposure of diagnostic x-ray examinations; result of national investigation in 2002","volume":"47","author":"Asada","year":"2001","journal-title":"Japan. J. Clin. Radiol."},{"key":"jrpaa0c39bib003","first-page":"127","type":"journal-article","article-title":"Analysis of patient exposure dose for mammography in 2001","volume":"18","author":"Asada","year":"2003","journal-title":"Japan J Breast Cancer"},{"key":"jrpaa0c39bib004","first-page":"55","type":"journal-article","article-title":"Patient exposure doses from medical x-ray examinations in Japan (2003)","volume":"75","author":"Suzuki","year":"2005","journal-title":"Japan J. Med. Instrum."},{"key":"jrpaa0c39bib005","doi-asserted-by":"publisher","first-page":"1582","DOI":"10.6009\/jjrt.65.1582","type":"journal-article","article-title":"The survey of patient exposure doses from diagnostic x-ray examinations-progress report 2","volume":"65","author":"Suzuki","year":"2009","journal-title":"Japan. J. Radiol. Technol."},{"key":"jrpaa0c39bib006","first-page":"302","type":"journal-article","article-title":"Analysis of patient exposure doses for mammography","volume":"153","author":"Asada","year":"2009","journal-title":"Med. Biol."},{"key":"jrpaa0c39bib007","doi-asserted-by":"publisher","first-page":"371","DOI":"10.6009\/jjrt.2013_JSRT_69.4.371","type":"journal-article","article-title":"Investigation of patient exposure doses in diagnostic radiography in 2011 questionnaire","volume":"69","author":"Asada","year":"2013","journal-title":"Japan. J. Radiol. Technol."},{"key":"jrpaa0c39bib008","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1088\/0952-4746\/34\/1\/125","type":"journal-article","article-title":"Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan","volume":"34","author":"Asada","year":"2014","journal-title":"J. Radiol. Prot."},{"key":"jrpaa0c39bib009","first-page":"1","type":"journal-article","article-title":"Actual condition survey of patient radiation exposures and leakage radiation in mammography","volume":"416","author":"Suzuki","year":"2011","journal-title":"FBNews"},{"key":"jrpaa0c39bib010","author":"Kouchi","year":"2005","type":"other"},{"key":"jrpaa0c39bib011","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.6009\/jjrt.2012_JSRT_68.9.1261","type":"journal-article","article-title":"Summary of results of the patient exposures in diagnostic radiography in 2011 questionnaire\u2014focus on radiographic conditions","volume":"68","author":"Asada","year":"2012","journal-title":"Japan. J. Radiol. Technol."},{"key":"jrpaa0c39bib012","doi-asserted-by":"publisher","first-page":"455","DOI":"10.6009\/jjrt.KJ00001364379","type":"journal-article","article-title":"Evaluation of the FPD in the general radiography","volume":"58","author":"Kishimoto","year":"2002","journal-title":"Japan. J. Radiol. Technol."},{"key":"jrpaa0c39bib013","first-page":"22","type":"journal-article","article-title":"Radiation protection in the FPD system, action to patient exposure reduction","author":"Kobayashi","year":"2012","journal-title":"INNERVISION"},{"key":"jrpaa0c39bib014","doi-asserted-by":"publisher","first-page":"1381","DOI":"10.6009\/jjrt.67.1381","type":"journal-article","article-title":"Study of appropriate dosing in consideration of image quality and patient dose on the digital radiography 2011","volume":"67","author":"Kishimoto","year":"2011","journal-title":"Japan. J. Radiol. Technol."},{"key":"jrpaa0c39bib015","first-page":"p64","author":"Okabe","year":"2008","type":"other"},{"key":"jrpaa0c39bib016","author":"Pisano","year":"2004","type":"other"},{"key":"jrpaa0c39bib017","first-page":"p80","author":"IAEA","year":"2006","type":"book"},{"key":"jrpaa0c39bib018","first-page":"p43","type":"book","article-title":"Radiation and your patient\u2014a guide for medical practitioners","author":"ICRP","year":"2001"},{"key":"jrpaa0c39bib019","article-title":"Managing patient dose in digital radiology","author":"ICRP","year":"2004","type":"book"}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0952-4746\/36\/i=2\/a=N8\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0952-4746\/36\/i=2\/a=N8?key=crossref.21ead83eb3b87848d4244d1cb789f860","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0952-4746\/36\/2\/N8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0952-4746\/36\/2\/N8\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0952-4746\/36\/2\/N8\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0952-4746\/36\/2\/N8\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T13:00:08Z","timestamp":1786798808000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0952-4746\/36\/2\/N8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3,15]]},"references-count":19,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2016,3,15]]},"published-print":{"date-parts":[[2016,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/0952-4746\/36\/2\/n8","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,3,15]]},"assertion":[{"value":"Survey of patient exposure from general radiography and mammography in Japan in 2014","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2016 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2015-03-16","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-11-19","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-03-15","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}