{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T13:23:59Z","timestamp":1794057839722,"version":"4.8.0"},"reference-count":22,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2015,4,2]],"date-time":"2015-04-02T00:00:00Z","timestamp":1427932800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2015,4,2]],"date-time":"2015-04-02T00:00:00Z","timestamp":1427932800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2015,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The pain and risk of infection associated with invasive blood sampling for blood gas measurements necessitate the search for reliable noninvasive techniques. In this work we developed a novel rate-based noninvasive method for a safe and fast assessment of respiratory status. A small sampler was built to collect the gases diffusing out of the skin. It was connected to a CO\n                    <jats:sub>2<\/jats:sub>\n                    sensor through gas-impermeable tubing. During a measurement, the CO\n                    <jats:sub>2<\/jats:sub>\n                    initially present in the sampler was first removed by purging it with nitrogen. The gases in the system were then recirculated between the sampler and the CO\n                    <jats:sub>2<\/jats:sub>\n                    sensor, and the CO\n                    <jats:sub>2<\/jats:sub>\n                    diffusion rate into the sampler was measured. Because the measurement is based on the initial transcutaneous diffusion rate, reaching mass transfer equilibrium and heating the skin is no longer required, thus, making it much faster and safer than traditional method. A series of designed experiments were performed to analyze the effect of the measurement parameters such as sampler size, measurement location, subject positions, and movement. After the factor analysis tests, the prototype was sent to a level IV NICU for clinical trial. The results show that the measured initial rate of increase in CO\n                    <jats:sub>2<\/jats:sub>\n                    partial pressure is linearly correlated with the corresponding arterial blood gas measurements. The new approach can be used as a trending tool, making frequent blood sampling unnecessary for respiratory status monitoring.\n                  <\/jats:p>","DOI":"10.1088\/0967-3334\/36\/5\/883","type":"journal-article","created":{"date-parts":[[2015,4,3]],"date-time":"2015-04-03T10:04:48Z","timestamp":1428055488000},"page":"883-894","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":29,"title":["A rate-based transcutaneous CO\n                    <sub>2<\/sub>\n                    sensor for noninvasive respiration monitoring"],"prefix":"10.1088","volume":"36","author":[{"given":"M","family":"Chatterjee","sequence":"first","affiliation":[{"name":"University of Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"X","family":"Ge","sequence":"additional","affiliation":[{"name":"University of Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y","family":"Kostov","sequence":"additional","affiliation":[{"name":"University of Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P","family":"Luu","sequence":"additional","affiliation":[{"name":"University of Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L","family":"Tolosa","sequence":"additional","affiliation":[{"name":"University of Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H","family":"Woo","sequence":"additional","affiliation":[{"name":"University of Maryland School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R","family":"Viscardi","sequence":"additional","affiliation":[{"name":"University of Maryland School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S","family":"Falk","sequence":"additional","affiliation":[{"name":"GE Healthcare"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R","family":"Potts","sequence":"additional","affiliation":[{"name":"Fluorometrix Biomedical"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G","family":"Rao","sequence":"additional","affiliation":[{"name":"University of Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2015,4,2]]},"reference":[{"key":"pmea510092bib001","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1111\/j.1399-6576.1978.tb01404.x","type":"journal-article","article-title":"An improved sensor and a method for transcutaneous CO2 monitoring","volume":"68","author":"Beran","year":"1978","journal-title":"Acta Anaesthesiol. Scand. Suppl."},{"key":"pmea510092bib005","doi-asserted-by":"publisher","first-page":"S48","DOI":"10.1213\/01.ane.0000278642.16117.f8","type":"journal-article","article-title":"The design, use, and results of transcutaneous carbon dioxide analysis: current and future directions","volume":"105","author":"Eberhard","year":"2007","journal-title":"Anesthesia Analgesia"},{"key":"pmea510092bib006","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1046\/j.1440-1754.2002.00041.x","type":"journal-article","article-title":"Hypocarbia in the ventilated preterm infant and its effect on intraventricular haemorrhage and bronchopulmonary dysplasia","volume":"38","author":"Erickson","year":"2002","journal-title":"J. Paediatr. Child Health"},{"key":"pmea510092bib008","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/S0095-5108(18)30142-8","type":"journal-article","article-title":"Volutrauma, paCO2 levels, and neurodevelopmental sequelae following assisted ventilation","volume":"25","author":"Gannon","year":"1998","journal-title":"Clin. Perinatol."},{"key":"pmea510092bib009","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1001\/archpedi.1995.02170190027005","type":"journal-article","article-title":"Leviton A. Hypocarbia before surfactant therapy appears to increase bronchopulmonary dysplasia risk in infants with respiratory distress syndrome","volume":"149","author":"Garland","year":"1995","journal-title":"Arch. Pediatr. Adolesc. Med."},{"key":"pmea510092bib011","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1378\/chest.80.4.442","type":"journal-article","article-title":"Transcutaneous noninvasive monitoring of carbon dioxide tension","volume":"80","author":"Greenspan","year":"1981","journal-title":"Chest"},{"key":"pmea510092bib012","first-page":"1419","type":"journal-article","article-title":"Need for blood transfusion in premature infants in 2 Dutch perinatology centres particularly determined by blood sampling for diagnosis","volume":"152","author":"Hack","year":"2008","journal-title":"Ned. Tijdschr. Geneeskd."},{"key":"pmea510092bib013","doi-asserted-by":"publisher","first-page":"e583","DOI":"10.1542\/peds.2008-1016","type":"journal-article","article-title":"Permissive hypercapnia and risk for brain injury and developmental impairment","volume":"122","author":"Hagen","year":"2008","journal-title":"Pediatrics"},{"key":"pmea510092bib014","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1159\/000308454","type":"journal-article","article-title":"Blood gases and retinopathy of prematurity: The ELGAN study","volume":"99","author":"Hauspurg","year":"2011","journal-title":"Neonatology"},{"key":"pmea510092bib015","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1203\/00006450-199912000-00007","type":"journal-article","article-title":"The new BPD: an arrest of lung development","volume":"46","author":"Jobe","year":"1999","journal-title":"Pediatr. Res."},{"key":"pmea510092bib016","doi-asserted-by":"publisher","first-page":"1723","DOI":"10.1164\/ajrccm.163.7.2011060","type":"journal-article","article-title":"Bronchopulmonary dysplasia","volume":"163","author":"Jobe","year":"2001","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"pmea510092bib017","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1038\/sj.jp.7211492","type":"journal-article","article-title":"Hypercapnia during the first 3\u2009d of life is associated with severe intraventricular hemorrhage in very low birth weight infants","volume":"26","author":"Kaiser","year":"2006","journal-title":"J. Perinatol."},{"key":"pmea510092bib018","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1007\/BF01468090","type":"journal-article","article-title":"Bloodless, continuous monitoring of the acid-base status in man by transcutaneous measurments of the arterial pO2 and pCO2 as well as the concentration of hemoglobin at body temperature","volume":"51","author":"L\u00fcbbers","year":"1973","journal-title":"Klin. Wochenschr."},{"key":"pmea510092bib019","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1080\/08035250410033015","type":"journal-article","article-title":"Early hypocarbia of preterm infants: its relationship to periventricular leukomalacia and cerebral palsy, and its perinatal risk factors","volume":"94","author":"Murase","year":"2005","journal-title":"Acta Paediatr."},{"key":"pmea510092bib020","doi-asserted-by":"publisher","first-page":"2095","DOI":"10.1111\/j.1365-2672.2007.03440.x","type":"journal-article","article-title":"Orthogonal array design in optimizing ERIC-PCR system for fingerprinting rat\u2019s intestinal microflora","volume":"103","author":"Peng","year":"2007","journal-title":"J. Appl. Microbiol."},{"key":"pmea510092bib021","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1097\/01.PCC.0000102384.60676.E5","type":"journal-article","article-title":"Current limitations of volumetric capnography in surfactant-depleted small lungs","volume":"5","author":"Proquitt\u00e9","year":"2004","journal-title":"Pediatr. Crit. Care Med."},{"key":"pmea510092bib022","doi-asserted-by":"publisher","first-page":"1955","DOI":"10.4187\/respcare.02011","type":"journal-article","article-title":"AARC clinical practice guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012","volume":"57","author":"Restrepo","year":"2012","journal-title":"Respir. Care"},{"key":"pmea510092bib023","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1590\/S0103-507X2010000100003","type":"journal-article","article-title":"Closed system for blood sampling and transfusion in critically ill patients","volume":"22","author":"Rezende","year":"2010","journal-title":"Rev. Bras. Ter. Intensiva."},{"key":"pmea510092bib027","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/712678","type":"journal-article","article-title":"Formulation development and evaluation of hybrid nanocarrier for cancer therapy: Taguchi orthogonal array based design","volume":"2013","author":"Tekade","year":"2013","journal-title":"Biomed. Res. Int."},{"key":"pmea510092bib028","doi-asserted-by":"publisher","first-page":"F53","DOI":"10.1136\/fn.84.1.F53","type":"journal-article","article-title":"An automatic incision device for obtaining blood samples from the heels of preterm infants causes less damage than a conventional manual lancet","volume":"84","author":"Vertanen","year":"2001","journal-title":"Arch. Dis. Child Fetal Neonatal Ed."},{"key":"pmea510092bib029","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1007\/BF03013040","type":"journal-article","article-title":"Misleading end-tidal CO2 tensions","volume":"43","author":"Wahba","year":"1996","journal-title":"Can. J. Anaesth."},{"key":"pmea510092bib031","author":"Yang","year":"2002","type":"book"}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0967-3334\/36\/i=5\/a=883\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/36\/i=5\/a=883?key=crossref.c87d84dd9195e04b4e94faeae4f81418","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/36\/5\/883","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/36\/5\/883\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/36\/5\/883\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/36\/i=5\/a=883\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/36\/i=5\/a=883?key=crossref.c87d84dd9195e04b4e94faeae4f81418","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/36\/5\/883\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T12:35:53Z","timestamp":1794054953000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/36\/5\/883"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4,2]]},"references-count":22,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2015,4,2]]},"published-print":{"date-parts":[[2015,5,1]]}},"URL":"https:\/\/doi.org\/10.1088\/0967-3334\/36\/5\/883","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,4,2]]},"assertion":[{"value":"A rate-based transcutaneous CO\n                      2\n                      sensor for noninvasive respiration monitoring","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2015 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2015-02-05","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-02-13","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2015-04-02","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}