{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T00:41:51Z","timestamp":1792111311896,"version":"4.4.0"},"reference-count":32,"publisher":"IOP Publishing","issue":"6","license":[{"start":{"date-parts":[[2016,5,20]],"date-time":"2016-05-20T00:00:00Z","timestamp":1463702400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2016,5,20]],"date-time":"2016-05-20T00:00:00Z","timestamp":1463702400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"European Union 7th Framework Programme on R&D","award":["WELCOME\/611223"],"award-info":[{"award-number":["WELCOME\/611223"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2016,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The measurement of rapid regional lung volume changes by electrical impedance tomography (EIT) could determine regional lung function in patients with obstructive lung diseases during pulmonary function testing (PFT). EIT examinations carried out before and after bronchodilator reversibility testing could detect the presence of spatial and temporal ventilation heterogeneities and analyse their changes in response to inhaled bronchodilator on the regional level. We examined seven patients suffering from chronic asthma (49\u2009\u2009\u00b1\u2009\u200919 years, mean age\u2009\u2009\u00b1\u2009\u2009SD) using EIT at a scan rate of 33 images s\n                    <jats:sup>\u22121<\/jats:sup>\n                    during tidal breathing and PFT with forced full expiration. The patients were studied before and 5, 10 and 20\u2009min after bronchodilator inhalation. Seven age- and sex-matched human subjects with no lung disease history served as a control study group. The spatial heterogeneity of lung function measures was quantified by the global inhomogeneity indices calculated from the pixel values of tidal volume, forced expiratory volume in one second (FEV\n                    <jats:sub>1<\/jats:sub>\n                    ), forced vital capacity (FVC), peak flow and forced expiratory flow between 25% and 75% of FVC as well as histograms of pixel FEV\n                    <jats:sub>1<\/jats:sub>\n                    \/FVC values. Temporal heterogeneity was assessed using the pixel values of expiration times needed to exhale 75% and 90% of pixel FVC. Regional lung function was more homogeneous in the healthy subjects than in the patients with asthma. Spatial and temporal ventilation distribution improved in the patients with asthma after the bronchodilator administration as evidenced mainly by the histograms of pixel FEV\n                    <jats:sub>1<\/jats:sub>\n                    \/FVC values and pixel expiration times. The examination of regional lung function using EIT enables the assessment of spatial and temporal heterogeneity of ventilation distribution during bronchodilator reversibility testing. EIT may become a new tool in PFT, allowing the estimation of the natural disease progression and therapy effects on the regional and not only global level.\n                  <\/jats:p>","DOI":"10.1088\/0967-3334\/37\/6\/698","type":"journal-article","created":{"date-parts":[[2016,5,21]],"date-time":"2016-05-21T18:47:58Z","timestamp":1463856478000},"page":"698-712","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":76,"title":["Regional lung function determined by electrical impedance tomography during bronchodilator reversibility testing in patients with asthma"],"prefix":"10.1088","volume":"37","author":[{"given":"I","family":"Frerichs","sequence":"first","affiliation":[{"name":"University Medical Centre Schleswig-Holstein"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Z","family":"Zhao","sequence":"additional","affiliation":[{"name":"Furtwangen University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T","family":"Becher","sequence":"additional","affiliation":[{"name":"University Medical Centre Schleswig-Holstein"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P","family":"Zabel","sequence":"additional","affiliation":[{"name":"Research Center Borstel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N","family":"Weiler","sequence":"additional","affiliation":[{"name":"University Medical Centre Schleswig-Holstein"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B","family":"Vogt","sequence":"additional","affiliation":[{"name":"University Medical Centre Schleswig-Holstein"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2016,5,20]]},"reference":[{"key":"pmeaaa1ae0bib001","doi-asserted-by":"publisher","first-page":"S35","DOI":"10.1088\/0967-3334\/30\/6\/S03","type":"journal-article","article-title":"GREIT: a unified approach to 2D linear EIT reconstruction of lung images","volume":"30","author":"Adler","year":"2009","journal-title":"Physiol. Meas."},{"key":"pmeaaa1ae0bib002","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1109\/10.486261","type":"journal-article","article-title":"Impedance imaging of lung ventilation: do we need to account for chest expansion?","volume":"43","author":"Adler","year":"1996","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaaa1ae0bib003","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1186\/s13054-014-0679-6","type":"journal-article","article-title":"Assessment of respiratory system compliance with electrical impedance tomography using a positive end-expiratory pressure wave maneuver during pressure support ventilation: a pilot clinical study","volume":"18","author":"Becher","year":"2014","journal-title":"Crit. Care"},{"key":"pmeaaa1ae0bib004","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1007\/s00134-013-2898-8","type":"journal-article","article-title":"Ventilation distribution measured with EIT at varying levels of pressure support and neurally adjusted ventilatory assist in patients with ALI","volume":"39","author":"Blankman","year":"2013","journal-title":"Intensive Care Med."},{"key":"pmeaaa1ae0bib005","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/S1579-2129(08)60072-5","type":"journal-article","article-title":"Assessment of differential lung function by electrical impedance tomography","volume":"44","author":"de Lema","year":"2008","journal-title":"Arch. Bronconeumol."},{"key":"pmeaaa1ae0bib006","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.1088\/0967-3334\/34\/10\/1303","type":"journal-article","article-title":"Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography","volume":"34","author":"Elke","year":"2013","journal-title":"Physiol. Meas."},{"key":"pmeaaa1ae0bib007","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1097\/MCC.0000000000000088","type":"journal-article","article-title":"Electrical impedance tomography imaging of the cardiopulmonary system","volume":"20","author":"Frerichs","year":"2014","journal-title":"Curr. Opin. Crit. Care"},{"key":"pmeaaa1ae0bib008","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.resp.2004.07.014","type":"journal-article","article-title":"Distribution of ventilation in young and elderly adults determined by electrical impedance tomography","volume":"143","author":"Frerichs","year":"2004","journal-title":"Respir. Physiol. Neurobiol."},{"key":"pmeaaa1ae0bib009","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1152\/japplphysiol.00081.2002","type":"journal-article","article-title":"Detection of local lung air content by electrical impedance tomography compared with electron beam CT","volume":"93","author":"Frerichs","year":"2002","journal-title":"J. Appl. Physiol."},{"key":"pmeaaa1ae0bib010","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.media.2015.04.001","type":"journal-article","article-title":"Globally optimal co-segmentation of three-dimensional pulmonary (1)H and hyperpolarized (3)He MRI with spatial consistence prior","volume":"23","author":"Guo","year":"2015","journal-title":"Med. Image Anal."},{"key":"pmeaaa1ae0bib011","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1111\/j.1399-6576.2006.00958.x","type":"journal-article","article-title":"Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography","volume":"50","author":"Hinz","year":"2006","journal-title":"Acta Anaesthesiol. Scand."},{"key":"pmeaaa1ae0bib012","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1002\/jmri.25010","type":"journal-article","article-title":"Pulmonary CT and MRI phenotypes that help explain chronic pulmonary obstruction disease pathophysiology and outcomes","volume":"43","author":"Hoffman","year":"2016","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmeaaa1ae0bib013","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1148\/radiol.10091937","type":"journal-article","article-title":"Chronic obstructive pulmonary disease: longitudinal hyperpolarized (3)He MR imaging","volume":"256","author":"Kirby","year":"2010","journal-title":"Radiology"},{"key":"pmeaaa1ae0bib014","doi-asserted-by":"publisher","first-page":"1917","DOI":"10.1007\/s00134-012-2684-z","type":"journal-article","article-title":"Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?","volume":"38","author":"Leonhardt","year":"2012","journal-title":"Intensive Care Med."},{"key":"pmeaaa1ae0bib015","first-page":"1024","type":"journal-article","article-title":"Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome-assessed by electric impedance tomography","volume":"76","author":"Lowhagen","year":"2010","journal-title":"Minerva Anestesiol."},{"key":"pmeaaa1ae0bib016","doi-asserted-by":"publisher","first-page":"1823","DOI":"10.1097\/CCM.0000000000001083","type":"journal-article","article-title":"Effects of sigh on regional lung strain and ventilation heterogeneity in acute respiratory failure patients undergoing assisted mechanical ventilation","volume":"43","author":"Mauri","year":"2015","journal-title":"Crit. Care Med."},{"key":"pmeaaa1ae0bib017","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1183\/09031936.00138311","type":"journal-article","article-title":"The effect of airway pressure and oscillation amplitude on ventilation in pre-term infants","volume":"40","author":"Miedema","year":"2012","journal-title":"Eur. Respir. J."},{"key":"pmeaaa1ae0bib018","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1152\/jappl.1966.21.3.749","type":"journal-article","article-title":"Regional distribution of inspired gas in the lung","volume":"21","author":"Milic-Emili","year":"1966","journal-title":"J. Appl. Physiol."},{"key":"pmeaaa1ae0bib019","doi-asserted-by":"publisher","first-page":"1726","DOI":"10.1002\/mrm.25550","type":"journal-article","article-title":"Pulmonary hyperpolarized Xe morphometry for mapping xenon gas concentrations and alveolar oxygen partial pressure: proof-of-concept demonstration in healthy and COPD subjects","volume":"74","author":"Ouriadov","year":"2015","journal-title":"Magn. Reson. Med."},{"key":"pmeaaa1ae0bib020","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1183\/09031936.00088814","type":"journal-article","article-title":"Monitoring asthma in children","volume":"45","author":"Pijnenburg","year":"2015","journal-title":"Eur. Respir. J."},{"key":"pmeaaa1ae0bib021","doi-asserted-by":"publisher","first-page":"S115","DOI":"10.1088\/0967-3334\/27\/5\/S10","type":"journal-article","article-title":"Comparison of different methods to define regions of interest for evaluation of regional lung ventilation by EIT","volume":"27","author":"Pulletz","year":"2006","journal-title":"Physiol. Meas."},{"key":"pmeaaa1ae0bib022","doi-asserted-by":"publisher","first-page":"R82","DOI":"10.1186\/cc7900","type":"journal-article","article-title":"Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study","volume":"13","author":"Richard","year":"2009","journal-title":"Crit. Care"},{"key":"pmeaaa1ae0bib023","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1088\/0967-3334\/23\/1\/322","type":"journal-article","article-title":"Use of electrical impedance tomography (EIT) for the assessment of unilateral pulmonary function","volume":"23","author":"Serrano","year":"2002","journal-title":"Physiol. Meas."},{"key":"pmeaaa1ae0bib024","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1088\/0967-3334\/23\/1\/324","type":"journal-article","article-title":"Epoprostenol-induced pulmonary vasodilatation in patients with pulmonary hypertension measured by electrical impedance tomography","volume":"23","author":"Smit","year":"2002","journal-title":"Physiol. Meas."},{"key":"pmeaaa1ae0bib025","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1152\/japplphysiol.01630.2011","type":"journal-article","article-title":"Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing","volume":"113","author":"Vogt","year":"2012","journal-title":"J. Appl. Physiol."},{"key":"pmeaaa1ae0bib026","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/j.acra.2015.10.010","type":"journal-article","article-title":"Second-order texture measurements of He ventilation MRI: proof-of-concept evaluation of asthma bronchodilator response","volume":"23","author":"Zha","year":"2016","journal-title":"Acad. Radiol."},{"key":"pmeaaa1ae0bib027","doi-asserted-by":"publisher","first-page":"S81","DOI":"10.1088\/0967-3334\/26\/2\/008","type":"journal-article","article-title":"EIT images of ventilation: what contributes to the resistivity changes?","volume":"26","author":"Zhang","year":"2005","journal-title":"Physiol. Meas."},{"key":"pmeaaa1ae0bib028","doi-asserted-by":"publisher","first-page":"109","DOI":"10.2174\/1874120701307010109","type":"journal-article","article-title":"Human CT measurements of structure\/electrode position changes during respiration with electrical impedance tomography","volume":"7","author":"Zhang","year":"2013","journal-title":"Open Biomed. Eng. J."},{"key":"pmeaaa1ae0bib029","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1016\/j.jcf.2012.03.011","type":"journal-article","article-title":"Regional ventilation in cystic fibrosis measured by electrical impedance tomography","volume":"11","author":"Zhao","year":"2012","journal-title":"J. Cyst. Fibrosis."},{"key":"pmeaaa1ae0bib030","doi-asserted-by":"publisher","first-page":"1900","DOI":"10.1007\/s00134-009-1589-y","type":"journal-article","article-title":"Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution","volume":"35","author":"Zhao","year":"2009","journal-title":"Intensive Care Med."},{"key":"pmeaaa1ae0bib031","doi-asserted-by":"publisher","first-page":"N107","DOI":"10.1088\/0967-3334\/34\/11\/N107","type":"journal-article","article-title":"Regional airway obstruction in cystic fibrosis determined by electrical impedance tomography in comparison with high resolution CT","volume":"34","author":"Zhao","year":"2013","journal-title":"Physiol. Meas."},{"key":"pmeaaa1ae0bib032","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0072675","type":"journal-article","article-title":"Effect of PEEP and tidal volume on ventilation distribution and end-expiratory lung volume: a prospective experimental animal and pilot clinical study","volume":"8","author":"Zick","year":"2013","journal-title":"PLoS One"}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0967-3334\/37\/i=6\/a=698\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/37\/i=6\/a=698?key=crossref.3c81bbc545c7450d2a8a0dad579fe7ed","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/6\/698","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/6\/698\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/6\/698\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/6\/698\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T13:55:27Z","timestamp":1788616527000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/6\/698"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5,20]]},"references-count":32,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2016,5,20]]},"published-print":{"date-parts":[[2016,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/0967-3334\/37\/6\/698","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,20]]},"assertion":[{"value":"Regional lung function determined by electrical impedance tomography during bronchodilator reversibility testing in patients with asthma","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2016 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2015-12-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-03-04","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-05-20","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}