{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T14:16:16Z","timestamp":1788617776000,"version":"build-2803163510"},"reference-count":23,"publisher":"IOP Publishing","issue":"8","license":[{"start":{"date-parts":[[2016,7,25]],"date-time":"2016-07-25T00:00:00Z","timestamp":1469404800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2016,7,25]],"date-time":"2016-07-25T00:00:00Z","timestamp":1469404800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2016,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>False arrhythmia alarms pose a major threat to the quality of care in today\u2019s ICU. Thus, the PhysioNet\/Computing in Cardiology Challenge 2015 aimed at reducing false alarms by exploiting multimodal cardiac signals recorded by a patient monitor. False alarms for asystole, extreme bradycardia, extreme tachycardia, ventricular flutter\/fibrillation as well as ventricular tachycardia were to be reduced using two electrocardiogram channels, up to two cardiac signals of mechanical origin as well as a respiratory signal.<\/jats:p>\n                  <jats:p>In this paper, an approach combining multimodal rhythmicity estimation and machine learning is presented. Using standard short-time autocorrelation and robust beat-to-beat interval estimation, the signal\u2019s self-similarity is analyzed. In particular, beat intervals as well as quality measures are derived which are further quantified using basic mathematical operations (min, mean, max, etc). Moreover, methods from the realm of image processing, 2D Fourier transformation combined with principal component analysis, are employed for dimensionality reduction. Several machine learning approaches are evaluated including linear discriminant analysis and random forest.<\/jats:p>\n                  <jats:p>Using an alarm-independent reduction strategy, an overall false alarm reduction with a score of 65.52 in terms of the real-time scoring system of the challenge is achieved on a hidden dataset. Employing an alarm-specific strategy, an overall real-time score of 78.20 at a true positive rate of 95% and a true negative rate of 78% is achieved. While the results for some categories still need improvement, false alarms for extreme tachycardia are suppressed with 100% sensitivity and specificity.<\/jats:p>","DOI":"10.1088\/0967-3334\/37\/8\/1233","type":"journal-article","created":{"date-parts":[[2016,7,25]],"date-time":"2016-07-25T08:14:00Z","timestamp":1469434440000},"page":"1233-1252","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":32,"title":["Reducing false alarms in the ICU by quantifying self-similarity of multimodal biosignals"],"prefix":"10.1088","volume":"37","author":[{"given":"Christoph Hoog","family":"Antink","sequence":"first","affiliation":[{"name":"RWTH Aachen University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steffen","family":"Leonhardt","sequence":"additional","affiliation":[{"name":"RWTH Aachen University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marian","family":"Walter","sequence":"additional","affiliation":[{"name":"RWTH Aachen University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2016,7,25]]},"reference":[{"key":"pmeaaa2d48bib001","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1109\/CIC.2015.7411127","type":"journal-article","article-title":"Multi-modal integrated approach towards reducing false arrhythmia alarms during continuous patient monitoring: the physionet challenge","volume":"42","author":"Ansari","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib002","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1088\/0967-3334\/34\/2\/123","type":"journal-article","article-title":"Robust inter-beat interval estimation in cardiac vibration signals","volume":"34","author":"Br\u00fcser","year":"2013","journal-title":"Physiol. Meas."},{"key":"pmeaaa2d48bib003","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1186\/cc1021","type":"journal-article","article-title":"Alarms in the intensive care unit: how can the number of false alarms be reduced?","volume":"5","author":"Chambrin","year":"2001","journal-title":"Crit. Care"},{"key":"pmeaaa2d48bib004","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1109\/CIC.2015.7408639","type":"journal-article","article-title":"The PhysioNet\/Computing in cardiology challenge 2015: reducing false arrhythmia alarms in the icu","volume":"42","author":"Clifford","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib022","doi-asserted-by":"publisher","first-page":"E5","DOI":"10.1088\/0967-3334\/37\/8\/E5","type":"journal-article","article-title":"False alarm reduction in critical care","volume":"37","author":"Clifford","year":"2016","journal-title":"Physiol. Meas."},{"key":"pmeaaa2d48bib005","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1109\/CIC.2015.7411019","type":"journal-article","article-title":"Suppression of false arrhythmia alarms using ecg and pulsatile waveforms","volume":"42","author":"Couto","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib006","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1109\/CIC.2015.7411018","type":"journal-article","article-title":"Heart beat fusion algorithm to reduce false alarms for arrhythmias","volume":"42","author":"Daluwatte","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib007","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1109\/CIC.2015.7408644","type":"journal-article","article-title":"Decreasing the false alarm rate of arrhythmias in intensive care using a machine learning approach","volume":"42","author":"Eerik\u00e4inen","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib008","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1109\/CIC.2015.7408640","type":"journal-article","article-title":"A multimodal approach to reduce false arrhythmia alarms in the intensive care unit","volume":"42","author":"Fallet","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib009","volume":"vol 3","author":"Flanagan","year":"2013","type":"book"},{"key":"pmeaaa2d48bib010","doi-asserted-by":"publisher","first-page":"28","DOI":"10.4037\/ajcc2010651","type":"journal-article","article-title":"Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms","volume":"19","author":"Graham","year":"2010","journal-title":"Am. J. Crit. Care"},{"key":"pmeaaa2d48bib011","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1093\/biostatistics\/kxj035","type":"journal-article","article-title":"Regularized linear discriminant analysis and its application in microarrays","volume":"8","author":"Guo","year":"2007","journal-title":"Biostatistics"},{"key":"pmeaaa2d48bib012","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1088\/0967-3334\/36\/8\/1679","type":"journal-article","article-title":"Detection of heart beats in multimodal data: a robust beat-to-beat interval estimation approach","volume":"36","author":"Hoog Antink","year":"2015a","journal-title":"Physiol. Meas."},{"key":"pmeaaa2d48bib013","doi-asserted-by":"publisher","first-page":"2895","DOI":"10.1364\/BOE.6.002895","type":"journal-article","article-title":"Beat-to-beat heart rate estimation fusing multimodal video and sensor data","volume":"6","author":"Hoog Antink","year":"2015b","journal-title":"Biomed. Opt. Express"},{"key":"pmeaaa2d48bib014","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1109\/CIC.2015.7408642","type":"journal-article","article-title":"Reducing false arrhythmia alarms using robust interval estimation and machine learning","volume":"42","author":"Hoog Antink","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib015","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1109\/CIC.2015.7411015","type":"journal-article","article-title":"Enhancing accuracy of arrhythmia classification by combining logical and machine learning techniques","volume":"42","author":"Kalidas","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib016","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1109\/CIC.2015.7411016","type":"journal-article","article-title":"Validation of arrhythmia detection library on bedside monitor data for triggering alarms in intensive care","volume":"42","author":"Krasteva","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib017","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1097\/00003246-199406000-00017","type":"journal-article","article-title":"Crying wolf: false alarms in a pediatric intensive care unit","volume":"22","author":"Lawless","year":"1994","journal-title":"Crit. Care Med."},{"key":"pmeaaa2d48bib018","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1109\/CIC.2015.7411017","type":"journal-article","article-title":"Reduction of false alarms in intensive care unit using multi-feature fusion method","volume":"42","author":"Liu","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib019","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s00134-003-2030-6","type":"journal-article","article-title":"Sleep in the intensive care unit","volume":"30","author":"Parthasarathy","year":"2004","journal-title":"Intensive Care Med."},{"key":"pmeaaa2d48bib020","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1109\/CIC.2015.7408641","type":"journal-article","article-title":"False alarms in intensive care unit monitors: detection of life-threatening arrhythmias using elementary algebra, descriptive statistics and fuzzy logic","volume":"42","author":"Plesinger","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2d48bib021","doi-asserted-by":"publisher","first-page":"1629","DOI":"10.1088\/0967-3334\/36\/8\/1629","type":"journal-article","article-title":"Robust detection of heart beats in multimodal data","volume":"36","author":"Silva","year":"2015","journal-title":"Physiol. Meas."},{"key":"pmeaaa2d48bib023","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1109\/CVPR.1991.139758","type":"journal-article","article-title":"Face recognition using eigenfaces","author":"Turk","year":"1991","journal-title":"IEEE Computer Society Conf. on Computer Vision and Pattern Recognition. Proc. CVPR\u201991"}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0967-3334\/37\/i=8\/a=1233\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/37\/i=8\/a=1233?key=crossref.299878338aa07fad7b9eb991b21cea77","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1233","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1233\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1233\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1233\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T14:00:26Z","timestamp":1788616826000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1233"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7,25]]},"references-count":23,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2016,7,25]]},"published-print":{"date-parts":[[2016,8,1]]}},"URL":"https:\/\/doi.org\/10.1088\/0967-3334\/37\/8\/1233","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,7,25]]},"assertion":[{"value":"Reducing false alarms in the ICU by quantifying self-similarity of multimodal biosignals","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2016 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2016-02-23","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-06-03","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-07-25","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}