{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T07:47:48Z","timestamp":1795160868178,"version":"4.10.3"},"reference-count":48,"publisher":"IOP Publishing","issue":"8","license":[{"start":{"date-parts":[[2016,7,25]],"date-time":"2016-07-25T00:00:00Z","timestamp":1469404800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2016,7,25]],"date-time":"2016-07-25T00:00:00Z","timestamp":1469404800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2016,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>False intensive care unit (ICU) alarms induce stress in both patients and clinical staff and decrease the quality of care, thus significantly increasing both the hospital recovery time and rehospitalization rates. In the PhysioNet\/CinC Challenge 2015 for reducing false arrhythmia alarms in ICU bedside monitor data, this paper validates the application of a real-time arrhythmia detection library (ADLib, Schiller AG) for the robust detection of five types of life-threatening arrhythmia alarms. The strength of the application is to give immediate feedback on the arrhythmia event within a scan interval of 3 s\u20137.5\u2009s, and to increase the noise immunity of electrocardiogram (ECG) arrhythmia analysis by fusing its decision with supplementary ECG quality interpretation and real-time pulse wave monitoring (quality and hemodynamics) using arterial blood pressure or photoplethysmographic signals. We achieved the third-ranked real-time score (79.41) in the challenge (Event 1), however, the rank was not officially recognized due to the \u2018closed-source\u2019 entry. This study shows the optimization of the alarm decision module, using tunable parameters such as the scan interval, lead quality threshold, and pulse wave features, with a follow-up improvement of the real-time score (80.07). The performance (true positive rate, true negative rate) is reported in the blinded challenge test set for different arrhythmias: asystole (83%, 96%), extreme bradycardia (100%, 90%), extreme tachycardia (98%, 80%), ventricular tachycardia (84%, 82%), and ventricular fibrillation (78%, 84%). Another part of this study considers the validation of ADLib with four reference ECG databases (AHA, EDB, SVDB, MIT-BIH) according to the international recommendations for performance reports in ECG monitors (ANSI\/AAMI EC57). The sensitivity (Se) and positive predictivity (+P) are: QRS detector QRS (Se, +P)\u2009\u2009&gt;\u2009\u200999.7%, ventricular ectopic beat (VEB) classifier VEB (Se, +P)\u2009\u2009=\u2009\u200995%, and ventricular fibrillation detector VFIB (P\u2009\u2009+\u2009\u2009= 94.8%)\u2009\u2009&gt;\u2009\u2009VFIB (Se\u2009\u2009=\u2009\u200986.4%), adjusted to the clinical setting requirements, giving preference to low false positive alarms.<\/jats:p>","DOI":"10.1088\/0967-3334\/37\/8\/1273","type":"journal-article","created":{"date-parts":[[2016,7,25]],"date-time":"2016-07-25T08:14:02Z","timestamp":1469434442000},"page":"1273-1297","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":32,"title":["Real-time arrhythmia detection with supplementary ECG quality and pulse wave monitoring for the reduction of false alarms in ICUs"],"prefix":"10.1088","volume":"37","author":[{"given":"Vessela","family":"Krasteva","sequence":"first","affiliation":[{"name":"Bulgarian Academy of Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irena","family":"Jekova","sequence":"additional","affiliation":[{"name":"Bulgarian Academy of Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Remo","family":"Leber","sequence":"additional","affiliation":[{"name":"Research and Signal Processing"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramun","family":"Schmid","sequence":"additional","affiliation":[{"name":"Research and Signal Processing"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger","family":"Ab\u00e4cherli","sequence":"additional","affiliation":[{"name":"Research and Signal Processing"},{"name":"University Hospital Basel"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2016,7,25]]},"reference":[{"key":"pmeaaa2867bib001","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1016\/j.jbi.2008.03.003","type":"journal-article","article-title":"Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform","volume":"41","author":"Aboukhalil","year":"2008","journal-title":"J. Biomed. Inform."},{"key":"pmeaaa2867bib002","article-title":"American Heart Association ventricular arrhythmia ECG database","author":"AHA","year":"1985","type":"web-resource"},{"key":"pmeaaa2867bib003","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1109\/TBME.2006.880909","type":"journal-article","article-title":"Detecting ventricular fibrillation by time-delay methods","volume":"54","author":"Amann","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaaa2867bib004","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1109\/CIC.2015.7411127","type":"journal-article","article-title":"Multi-modal integrated approach towards reducing false arrhythmia alarms during continuous patient monitoring: the PhysioNet Challenge 2015","volume":"42","author":"Ansari","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib005","article-title":"Testing and reporting performance results of cardiac rhythm and ST-segment measurement algorithms","author":"ANSI\/AAMI EC57:1998","year":"2003","type":"other"},{"key":"pmeaaa2867bib006","article-title":"Cardiac monitors, heart rate meters, and alarms","author":"ANSI\/AAMI EC13:2002","year":"2007","type":"other"},{"key":"pmeaaa2867bib007","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1109\/CIC.2015.7408642","type":"journal-article","article-title":"Reducing false arrhythmia alarms using robust interval estimation and machine learning","volume":"42","author":"Antink","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib008","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1097\/00002727-199208000-00006","type":"journal-article","article-title":"Discomfort to environmental noise: heart rate responses of SICU patients","volume":"15","author":"Baker","year":"1992","journal-title":"Crit. Care Nurs."},{"key":"pmeaaa2867bib009","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1109\/TBME.2013.2240452","type":"journal-article","article-title":"ECG signal quality during arrhythmia and its application to false alarm reduction","volume":"60","author":"Behar","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaaa2867bib010","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1515\/bmt.2011.005","type":"journal-article","article-title":"Medical device alarms","volume":"56","author":"Borowski","year":"2011","journal-title":"Biomed. Tech. (Berl)"},{"key":"pmeaaa2867bib011","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1186\/cc1021","type":"journal-article","article-title":"Review: alarms in the intensive care unit: how can the number of false alarms be reduced?","volume":"5","author":"Chambrin","year":"2001","journal-title":"Crit. Care"},{"key":"pmeaaa2867bib012","first-page":"829","type":"journal-article","article-title":"Using the blood pressure waveform to reduce critical false ECG alarms","volume":"33","author":"Clifford","year":"2006","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib013","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1109\/CIC.2015.7408639","type":"journal-article","article-title":"The PhysioNet\/Computing in Cardiology Challenge 2015: reducing false arrhythmia alarms in the ICU","volume":"42","author":"Clifford","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib014","author":"Comit\u00e9 Europ\u00e9en de Normalisation","year":"1995","type":"other"},{"key":"pmeaaa2867bib015","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1109\/CIC.2015.7411019","type":"journal-article","article-title":"Suppression of false arrhythmia alarms using ECG and pulsatile waveforms","volume":"42","author":"Couto","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib016","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1378\/chest.105.4.1217","type":"journal-article","article-title":"Name that tone. The proliferation of alarms in the intensive care unit","volume":"105","author":"Cropp","year":"1994","journal-title":"Chest"},{"key":"pmeaaa2867bib017","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1097\/00075198-200208000-00008","type":"journal-article","article-title":"The hostile environment of the intensive care unit","volume":"8","author":"Donchin","year":"2002","journal-title":"Curr. Opin. Crit. Care"},{"key":"pmeaaa2867bib0017a","first-page":"2721","type":"journal-article","article-title":"Practice Standards for electrocardiographic monitoring in hospital settings","volume":"110","author":"Drew","year":"2004","journal-title":"An American Heart Association Scientific Statement From the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young"},{"key":"pmeaaa2867bib018","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0110274","type":"journal-article","article-title":"Insights into the problem of alarm fatigue with physiologic monitor devices: a comprehensive observational study of consecutive intensive care unit patients","volume":"9","author":"Drew","year":"2014","journal-title":"PLoS One"},{"key":"pmeaaa2867bib019","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1109\/CIC.2015.7408644","type":"journal-article","article-title":"Decreasing the false alarm rate of arrhythmias in intensive care using a machine learning approach","volume":"42","author":"Eerik\u00e4inen","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib020","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1109\/CIC.2015.7408640","type":"journal-article","article-title":"A multimodal approach to reduce false arrhythmia alarms in the intensive care unit","volume":"42","author":"Fallet","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib021","article-title":"Improved detection and classification of arrhythmias in noise-corrupted electrocardiograms using contextual information","author":"Greenwald","year":"1990","type":"web-resource"},{"key":"pmeaaa2867bib022","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.ijcard.2003.11.006","type":"journal-article","article-title":"Influence of intensive coronary care acoustics on the quality of care and physiological state of patients","volume":"98","author":"Hagerman","year":"2005","journal-title":"Int. J. Cardiol."},{"key":"pmeaaa2867bib023","article-title":"Medical equipment\u2014part 2-27 particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment","author":"IEC 60601-2-27","year":"2011","type":"other"},{"key":"pmeaaa2867bib024","doi-asserted-by":"publisher","first-page":"1525","DOI":"10.1213\/01.ane.0000204385.01983.61","type":"journal-article","article-title":"Alarm algorithms in critical care monitoring","volume":"102","author":"Imhoff","year":"2006","journal-title":"Anesth. Analg."},{"key":"pmeaaa2867bib025","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1088\/0967-3334\/33\/9\/1463","type":"journal-article","article-title":"Threshold-based system for noise detection in multilead ECG recordings","volume":"33","author":"Jekova","year":"2012","journal-title":"Physiol. Meas."},{"key":"pmeaaa2867bib026","first-page":"573","type":"journal-article","article-title":"Lead quality monitoring for detection of the optimal snapshot time to record resting ECG","volume":"41","author":"Jekova","year":"2014","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib027","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1109\/CIC.2015.7411015","type":"journal-article","article-title":"Enhancing accuracy of arrhythmia classification by combining logical and machine learning techniques","volume":"42","author":"Kalidas","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib028","doi-asserted-by":"publisher","first-page":"1677","DOI":"10.1161\/01.CIR.95.6.1677","type":"journal-article","article-title":"Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms, and enhancing safety","volume":"95","author":"Kerber","year":"1997","journal-title":"Circulation"},{"key":"pmeaaa2867bib029","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/BF01772574","type":"journal-article","article-title":"An \u201calarming\u201d situation in the intensive therapy unit","volume":"9","author":"Kerr","year":"1983","journal-title":"Intensive Care Med."},{"key":"pmeaaa2867bib030","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/BF01259556","type":"journal-article","article-title":"A knowledge-based alarm system for monitoring cardiac operated patients-assessment of clinical performance","volume":"11","author":"Koski","year":"1994","journal-title":"Int. J. Clin. Monit. Comput."},{"key":"pmeaaa2867bib031","doi-asserted-by":"publisher","first-page":"e0140123","DOI":"10.1371\/journal.pone.0140123","type":"journal-article","article-title":"Superiority of classification tree versus cluster, fuzzy and discriminant models in a heartbeat classification system","volume":"10","author":"Krasteva","year":"2015a","journal-title":"PLoS One"},{"key":"pmeaaa2867bib032","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1109\/CIC.2015.7411016","type":"journal-article","article-title":"Validation of arrhythmia detection library on bedside monitor data for triggering alarms in intensive care","volume":"42","author":"Krasteva","year":"2015b","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib033","first-page":"349","type":"journal-article","article-title":"Classification of supraventricular and ventricular beats by QRS template matching and decision tree","volume":"41","author":"Krasteva","year":"2014","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib034","first-page":"347","type":"journal-article","article-title":"Computer detection of ventricular fibrillation","volume":"5","author":"Kuo","year":"1978","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib035","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1109\/CIC.2015.7411017","type":"journal-article","article-title":"Reduction of false alarms in intensive care unit using multi-feature fusion method","volume":"42","author":"Liu","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib036","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/0169-2607(91)90039-V","type":"journal-article","article-title":"The median filter as a preprocessor for a patient monitor limit alarm system in intensive care","volume":"34","author":"M\u00e4kivirta","year":"1991","journal-title":"Comput. Methods Programs Biomed."},{"key":"pmeaaa2867bib037","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1109\/51.932724","type":"web-resource","article-title":"The impact of the MIT-BIH arrhythmia database","volume":"20","author":"Moody","year":"2001"},{"key":"pmeaaa2867bib038","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1097\/00003246-200301000-00018","type":"journal-article","article-title":"Noise, stress, and annoyance in a pediatric intensive care unit","volume":"31","author":"Morrison","year":"2003","journal-title":"Crit. Care Med."},{"key":"pmeaaa2867bib039","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1109\/RBME.2013.2243724","type":"journal-article","article-title":"Implementation of artifact detection in critical care: a methodological review","volume":"6","author":"Nizami","year":"2013","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"pmeaaa2867bib040","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1007\/s001340050500","type":"journal-article","article-title":"Stressors in ICU: patients\u2019 evaluation","volume":"23","author":"Novaes","year":"1997","journal-title":"Intensive Care Med."},{"key":"pmeaaa2867bib041","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s00134-003-2030-6","type":"journal-article","article-title":"Sleep in the intensive care unit","volume":"30","author":"Parthasarathy","year":"2004","journal-title":"Intensive Care Med."},{"key":"pmeaaa2867bib042","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1109\/CIC.2015.7408641","type":"journal-article","article-title":"False alarms in intensive care unit monitors: detection of life-threatening arrhythmias using elementary algebra, descriptive statistics and fuzzy logic","volume":"42","author":"Plesinger","year":"2015","journal-title":"Comput. Cardiol."},{"key":"pmeaaa2867bib043","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0169-2607(90)90026-6","type":"journal-article","article-title":"Physiologic trend detection and artifact rejection: a parallel implementation of a multi-state Kalman filtering algorithm","volume":"31","author":"Sittig","year":"1990","journal-title":"Comput. Methods Programs Biomed."},{"key":"pmeaaa2867bib044","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1093\/oxfordjournals.eurheartj.a060332","type":"web-resource","article-title":"The European ST-T Database: standard for evaluating systems for the analysis of ST-T changes in ambulatory electrocardiography","volume":"13","author":"Taddei","year":"1992"},{"key":"pmeaaa2867bib045","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1067\/mhl.2001.116592","type":"journal-article","article-title":"Interactive relationships between hospital patients\u2019 noise induced stress and other stress with sleep","volume":"30","author":"Topf","year":"2001","journal-title":"Heart Lung"},{"key":"pmeaaa2867bib046","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1097\/00003246-199704000-00010","type":"journal-article","article-title":"Poor prognosis for existing monitors in the intensive care unit.","volume":"25","author":"Tsien","year":"1997","journal-title":"Crit. Care Med."},{"key":"pmeaaa2867bib047","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1007\/BF02347553","type":"journal-article","article-title":"Reduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure","volume":"42","author":"Zong","year":"2004","journal-title":"Med. Biol. Eng. Comput."}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0967-3334\/37\/i=8\/a=1273\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/37\/i=8\/a=1273?key=crossref.1532b67539ba5ce5fcb2e0600ba65c8b","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1273","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1273\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1273\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1273\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T13:54:56Z","timestamp":1788616496000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0967-3334\/37\/8\/1273"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7,25]]},"references-count":48,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2016,7,25]]},"published-print":{"date-parts":[[2016,8,1]]}},"URL":"https:\/\/doi.org\/10.1088\/0967-3334\/37\/8\/1273","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,7,25]]},"assertion":[{"value":"Real-time arrhythmia detection with supplementary ECG quality and pulse wave monitoring for the reduction of false alarms in ICUs","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2016 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2016-02-24","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-05-19","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-07-25","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}