{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T16:28:35Z","timestamp":1791304115043,"version":"4.3.1"},"reference-count":31,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2023,3,9]],"date-time":"2023-03-09T00:00:00Z","timestamp":1678320000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,9]],"date-time":"2023-03-09T00:00:00Z","timestamp":1678320000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000050","name":"National Heart, Lung, and Blood Institute","doi-asserted-by":"crossref","award":["1R01HL165138"],"award-info":[{"award-number":["1R01HL165138"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100000055","name":"National Institute on Deafness and Other Communication Disorders","doi-asserted-by":"crossref","award":["R21DC016468"],"award-info":[{"award-number":["R21DC016468"]}],"id":[{"id":"10.13039\/100000055","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Micromech. Microeng."],"published-print":{"date-parts":[[2023,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This paper reports a highly sensitive piezoelectric microelectromechanical systems (MEMS) resonant microphone array (RMA) for detection and classification of wheezing in lung sounds. The RMA is composed of eight width-stepped cantilever resonant microphones with Mel-distributed resonance frequencies from 230 to 630 Hz, the main frequency range of wheezing. At the resonance frequencies, the unamplified sensitivities of the microphones in the RMA are between 86 and 265 mV Pa<jats:sup>\u22121<\/jats:sup>, while the signal-to-noise ratios (SNRs) for 1 Pa sound pressure are between 86.6 and 98.0 dBA. Over 200\u2013650 Hz, the unamplified sensitivities are between 35 and 265 mV Pa<jats:sup>\u22121<\/jats:sup>, while the SNRs are between 79 and 98 dBA. Wheezing feature in lung sounds recorded by the RMA is more distinguishable than that recorded by a reference microphone with traditional flat sensitivity, and thus, the automatic classification accuracy of wheezing is higher with the lung sounds recorded by the RMA than with those by the reference microphone, when tested with deep learning algorithms on computer or with simple machine learning algorithms on low-power wireless chip set for wearable applications.<\/jats:p>","DOI":"10.1088\/1361-6439\/acbfc3","type":"journal-article","created":{"date-parts":[[2023,2,28]],"date-time":"2023-02-28T22:23:40Z","timestamp":1677623020000},"page":"044003","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":17,"title":["MEMS piezoelectric resonant microphone array for lung sound classification"],"prefix":"10.1088","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4461-9748","authenticated-orcid":true,"given":"Hai","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matin","family":"Barekatain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akash","family":"Roy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Song","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunqi","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0817-4956","authenticated-orcid":true,"given":"Yongkui","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anton","family":"Shkel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eun Sok","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2023,3,9]]},"reference":[{"key":"jmmacbfc3bib1","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1016\/S2213-2600(20)30105-3","article-title":"Prevalence and attributable health burden of chronic respiratory diseases, 1990\u20132017: a systematic analysis for the Global Burden of Disease Study 2017","volume":"8","author":"Soriano","year":"2020","journal-title":"Lancet Respir. Med."},{"key":"jmmacbfc3bib2","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1513\/AnnalsATS.201311-405PS","article-title":"The global burden of respiratory disease","volume":"11","author":"Ferkol","year":"2014","journal-title":"Ann. Am. Thorac. Soc."},{"key":"jmmacbfc3bib3","article-title":"Asthma","author":"","year":"2022"},{"key":"jmmacbfc3bib4","article-title":"Wheezing and asthma","author":"Gong","year":"1990","edition":"3rd edn,"},{"key":"jmmacbfc3bib5","doi-asserted-by":"publisher","first-page":"1403","DOI":"10.1164\/ajrccm.162.4.9912111","article-title":"A clinical index to define risk of asthma in young children with recurrent wheezing","volume":"162","author":"Castro-Rodr\u00edguez","year":"2000","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"jmmacbfc3bib6","doi-asserted-by":"publisher","first-page":"1942","DOI":"10.1183\/09031936.95.08111942","article-title":"Wheezes","volume":"8","author":"Meslier","year":"1995","journal-title":"Eur. Respir. J."},{"key":"jmmacbfc3bib7","author":"Priftis","year":"2018"},{"key":"jmmacbfc3bib8","article-title":"Electronic & digital stethoscopes for sale","author":"","year":"2022"},{"key":"jmmacbfc3bib9","article-title":"Thinklabs one digital stethoscope","author":"","year":"2022"},{"key":"jmmacbfc3bib10","doi-asserted-by":"publisher","first-page":"171","DOI":"10.3390\/s17010171","article-title":"Design of wearable breathing sound monitoring system for real-time wheeze detection","volume":"17","author":"Li","year":"2017","journal-title":"Sensors"},{"key":"jmmacbfc3bib11","article-title":"Datasheet of INMP411","author":"","year":"2014"},{"key":"jmmacbfc3bib12","article-title":"Datasheet of ICS-40730","author":"","year":"2020"},{"key":"jmmacbfc3bib13","article-title":"Datasheet of SPH2430HR5H-B","author":"","year":"2018"},{"key":"jmmacbfc3bib14","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1109\/JMEMS.2003.820260","article-title":"A new measurement microphone based on MEMS technology","volume":"12","author":"Scheeper","year":"2003","journal-title":"J. Microelectromech. Syst."},{"key":"jmmacbfc3bib15","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1109\/84.546403","article-title":"Piezoelectric cantilever microphone and microspeaker","volume":"5","author":"Lee","year":"1996","journal-title":"J. Microelectromech. Syst."},{"key":"jmmacbfc3bib16","doi-asserted-by":"publisher","first-page":"1296","DOI":"10.1073\/pnas.0407446102","article-title":"Microengineered hydromechanical cochlear model","volume":"102","author":"White","year":"2005","journal-title":"Proc. Natl Acad. Sci."},{"key":"jmmacbfc3bib17","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.sna.2009.12.021","article-title":"Development of piezoelectric acoustic sensor with frequency selectivity for artificial cochlea","volume":"158","author":"Shintaku","year":"2010","journal-title":"Sens. Actuators A"},{"key":"jmmacbfc3bib18","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1109\/JMEMS.2012.2216505","article-title":"Resonance-enhanced piezoelectric microphone array for broadband or prefiltered acoustic sensing","volume":"22","author":"Baumgartel","year":"2013","journal-title":"J. Microelectromech. Syst."},{"key":"jmmacbfc3bib19","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/23\/11\/115014","article-title":"Wide-range frequency selectivity in an acoustic sensor fabricated using a microbeam array with non-uniform thickness","volume":"23","author":"Shintaku","year":"2013","journal-title":"J. Micromech. Microeng."},{"key":"jmmacbfc3bib20","doi-asserted-by":"crossref","DOI":"10.1109\/IEDM19573.2019.8993658","article-title":"MEMS resonant microphone array for lung sound classification","author":"Liu","year":"2019"},{"key":"jmmacbfc3bib21","doi-asserted-by":"crossref","DOI":"10.1109\/MEMS46641.2020.9056160","article-title":"Multi-band MEMS resonant microphone array for continuous lung-sound monitoring and classification","author":"Liu","year":"2020"},{"key":"jmmacbfc3bib22","doi-asserted-by":"publisher","first-page":"3711","DOI":"10.1038\/s41598-019-39303-1","article-title":"Voltage readout from a piezoelectric intracochlear acoustic transducer implanted in a living guinea pig","volume":"9","author":"Zhao","year":"2019","journal-title":"Sci. Rep."},{"key":"jmmacbfc3bib23","doi-asserted-by":"publisher","DOI":"10.1038\/srep12447","article-title":"A microelectromechanical system artificial basilar membrane based on a piezoelectric cantilever array and its characterization using an animal model","volume":"5","author":"Jang","year":"2015","journal-title":"Sci. Rep."},{"key":"jmmacbfc3bib24","author":"Von B\u00e9k\u00e9sy","year":"1989"},{"key":"jmmacbfc3bib25","first-page":"193","article-title":"Features based on auditory physiology and perception","author":"Stern","year":"2012"},{"key":"jmmacbfc3bib26","article-title":"MEMS piezoelectric resonant microphone arrays and their applications","author":"Liu","year":"2022"},{"key":"jmmacbfc3bib27","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/ab03ea","article-title":"An open access database for the evaluation of respiratory sound classification algorithms","volume":"40","author":"Rocha","year":"2019","journal-title":"Physiol. Meas."},{"key":"jmmacbfc3bib28","first-page":"156","article-title":"Temporal convolutional networks for action segmentation and detection","author":"Lea","year":"2017"},{"key":"jmmacbfc3bib29","article-title":"CYBLE-416045-02","author":"","year":"2020"},{"key":"jmmacbfc3bib30","doi-asserted-by":"publisher","first-page":"4629","DOI":"10.1109\/JSEN.2019.2900713","article-title":"Continuous health monitoring with resonant-microphone-array-based wearable stethoscope","volume":"19","author":"Shkel","year":"2019","journal-title":"IEEE Sens. J."},{"key":"jmmacbfc3bib31","doi-asserted-by":"publisher","first-page":"258","DOI":"10.31438\/trf.hh2016.69","article-title":"Piezoelectric MEMS microphones noise sources","author":"Littrell","year":"2016"}],"container-title":["Journal of Micromechanics and Microengineering"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,9]],"date-time":"2023-03-09T12:50:54Z","timestamp":1678366254000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6439\/acbfc3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,9]]},"references-count":31,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,3,9]]},"published-print":{"date-parts":[[2023,4,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6439\/acbfc3","relation":{},"ISSN":["0960-1317","1361-6439"],"issn-type":[{"value":"0960-1317","type":"print"},{"value":"1361-6439","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,9]]},"assertion":[{"value":"MEMS piezoelectric resonant microphone array for lung sound classification","name":"article_title","label":"Article Title"},{"value":"Journal of Micromechanics and Microengineering","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2022-10-20","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-02-28","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-03-09","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}