{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T15:12:24Z","timestamp":1788966744240,"version":"build-2803163510"},"reference-count":39,"publisher":"IOP Publishing","issue":"31","license":[{"start":{"date-parts":[[2025,8,4]],"date-time":"2025-08-04T00:00:00Z","timestamp":1754265600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,8,4]],"date-time":"2025-08-04T00:00:00Z","timestamp":1754265600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100000287","name":"Royal Academy of Engineering","doi-asserted-by":"crossref","award":["CiET1819\/2\/78"],"award-info":[{"award-number":["CiET1819\/2\/78"]}],"id":[{"id":"10.13039\/501100000287","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100010269","name":"Wellcome Trust","doi-asserted-by":"crossref","award":["221367\/Z\/20\/Z"],"award-info":[{"award-number":["221367\/Z\/20\/Z"]}],"id":[{"id":"10.13039\/100010269","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"crossref","award":["EP\/P005209\/1"],"award-info":[{"award-number":["EP\/P005209\/1"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Phys. D: Appl. Phys."],"published-print":{"date-parts":[[2025,8,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Strain imaging using conventional x-ray tomography is a widely established technique for investigating the mechanical deformation of materials, including cement and batteries. However, its biomedical applications are primarily restricted to bone tissue due to the low contrast of soft tissues. X-ray phase contrast imaging, offering superior contrast-to-noise ratios in soft tissues, can in principle overcome this limitation. This study explores the feasibility of x-ray strain imaging for soft tissues using edge illumination (EI), a laboratory-based x-ray phase contrast technique. A phantom mimicking the mechanical properties of healthy and tumorous soft tissues, with a stiff inclusion invisible to conventional x-ray imaging, was tested alongside chicken soft tissue fixed in ethanol. While our study confirmed that EI phase contrast imaging provides improved contrast for such samples compared to absorption imaging, it also revealed a reduction in strain retrieval precision. Artefacts caused by absorbing bridges in the mask design and errors arising from differential phase signal integration, which vary spatially between scans, were identified as key limiting factors. Consequently, EI phase contrast strain imaging was unable to locate phantom inclusions based on mechanical contrast. However, EI\u2019s capability to increase spatial sampling frequency without compromising the field of view improved strain retrieval precision using its absorption contrast beyond that achieved with conventional x-ray strain imaging. These findings highlight the potential and challenges of applying EI to strain analysis in soft tissues, providing insights into its limitations and opportunities for further improvement.<\/jats:p>","DOI":"10.1088\/1361-6463\/adf452","type":"journal-article","created":{"date-parts":[[2025,7,25]],"date-time":"2025-07-25T22:48:49Z","timestamp":1753483729000},"page":"315402","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["On the applicability of x-ray strain imaging using the edge illumination technique in biomedical applications"],"prefix":"10.1088","volume":"58","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-1479-6344","authenticated-orcid":true,"given":"Carlo","family":"Peiffer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A","family":"Astolfo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7810-2301","authenticated-orcid":true,"given":"M","family":"Endrizzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C K","family":"Hagen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7150-2951","authenticated-orcid":true,"given":"A","family":"Olivo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9306-3673","authenticated-orcid":false,"given":"P R T","family":"Munro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,8,4]]},"reference":[{"key":"dadf452bib1","author":"Fung","year":"1981","edition":"2 edn"},{"key":"dadf452bib2","doi-asserted-by":"publisher","first-page":"1565","DOI":"10.1088\/0031-9155\/52\/6\/002","article-title":"Elastic moduli of normal and pathological human breast tissues: an inversion-technique-based investigation of 169 samples","volume":"52","author":"Samani","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"dadf452bib3","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/S0301-5629(02)00489-1","article-title":"Elastic modulus measurements of human liver and correlation with pathology","volume":"28","author":"Yeh","year":"2002","journal-title":"Ultrasound Med. Biol."},{"key":"dadf452bib4","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1016\/j.cgh.2007.06.012","article-title":"Assessment of hepatic fibrosis with magnetic resonance elastography","volume":"5","author":"Yin","year":"2007","journal-title":"Clin. Gastroenterol. Hepatology"},{"key":"dadf452bib5","doi-asserted-by":"publisher","first-page":"213","DOI":"10.3233\/CBM-2008-44-505","article-title":"Tissue elasticity properties as biomarkers for prostate cancer","volume":"4","author":"Hoyt","year":"2008","journal-title":"Cancer Biomarkers"},{"key":"dadf452bib6","author":"Walker","year":"1990","edition":"3 edn"},{"key":"dadf452bib7","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/0301-5629(90)90002-T","article-title":"Sonoelasticity images derived from ultrasound signals in mechanically vibrated tissues","volume":"16","author":"Lerner","year":"1990","journal-title":"Ultrasound Med. Biol."},{"key":"dadf452bib8","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.1088\/0031-9155\/45\/6\/317","article-title":"High-resolution tensor MR elastography for breast tumour detection","volume":"45","author":"Sinkus","year":"2000","journal-title":"Phys. Med. Biol."},{"key":"dadf452bib9","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1038\/nphoton.2017.6","article-title":"The emergence of optical elastography in biomedicine","volume":"11","author":"Kennedy","year":"2017","journal-title":"Nat. Photon."},{"key":"dadf452bib10","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.7150\/thno.18650","article-title":"Ultrasound elastography: review of techniques and clinical applications","volume":"7","author":"Sigrist","year":"2017","journal-title":"Theranostics"},{"key":"dadf452bib11","doi-asserted-by":"publisher","first-page":"1773","DOI":"10.1158\/0008-5472.CAN-19-1240","article-title":"Diagnostic accuracy of quantitative micro-elastography for margin assessment in breast-conserving surgery","volume":"80","author":"Kennedy","year":"2020","journal-title":"Cancer Res."},{"key":"dadf452bib12","doi-asserted-by":"publisher","first-page":"2913","DOI":"10.1364\/BOE.5.002913","article-title":"Analysis of image formation in optical coherence elastography using a multiphysics approach","volume":"5","author":"Chin","year":"2014","journal-title":"Biomed. Opt. Express"},{"key":"dadf452bib13","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1109\/JSTQE.2013.2291445","article-title":"A review of optical coherence elastography: fundamentals, techniques and prospects","volume":"20","author":"Kennedy","year":"2014","journal-title":"IEEE J. Sel. Top. Quantum Electron."},{"key":"dadf452bib14","doi-asserted-by":"publisher","DOI":"10.1002\/advs.201500332","article-title":"Quantifying bulk electrode strain and material displacement within lithium batteries via high-speed operando tomography and digital volume correlation","volume":"3","author":"Finegan","year":"2016","journal-title":"Adv. Sci."},{"key":"dadf452bib15","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1007\/s11340-013-9730-9","article-title":"In-situ analysis of laminated composite materials by x-ray micro-computed tomography and digital volume correlation","volume":"53","author":"Brault","year":"2013","journal-title":"Exp. Mech."},{"key":"dadf452bib16","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1007\/BF02323555","article-title":"Digital volume correlation: three-dimensional strain mapping using x-ray tomography","volume":"39","author":"Bay","year":"1999","journal-title":"Exp. Mech."},{"key":"dadf452bib17","doi-asserted-by":"publisher","DOI":"10.1115\/1.3127249","article-title":"Whole bone strain quantification by image registration: a validation study","volume":"131","author":"Hardisty","year":"2009","journal-title":"J. Biomech. Eng."},{"key":"dadf452bib18","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1038\/s41551-019-0477-1","article-title":"In situ characterization of nanoscale strains in loaded whole joints via synchrotron x-ray tomography","volume":"4","author":"Madi","year":"2020","journal-title":"Nat. Biomed. Eng."},{"key":"dadf452bib19","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1016\/j.actbio.2021.10.012","article-title":"Regional variations in discrete collagen fibre mechanics within intact intervertebral disc resolved using synchrotron computed tomography and digital volume correlation","volume":"138","author":"Disney","year":"2022","journal-title":"Acta Biomater."},{"key":"dadf452bib20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2022.105579","article-title":"Image quality and scan time optimisation for in situ phase contrast x-ray tomography of the intervertebral disc","volume":"138","author":"Disney","year":"2023","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"dadf452bib21","doi-asserted-by":"publisher","DOI":"10.1063\/1.2772193","article-title":"A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources","volume":"91","author":"Olivo","year":"2007","journal-title":"Appl. Phys. Lett."},{"key":"dadf452bib22","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa9e2c","article-title":"Anatomically realistic ultrasound phantoms using gel wax with 3D printed moulds","volume":"63","author":"Maneas","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"dadf452bib23","doi-asserted-by":"publisher","first-page":"5469","DOI":"10.1118\/1.4742902","article-title":"Calculation of strain images of a breast-mimicking phantom from 3D CT image data","volume":"39","author":"Kim","year":"2012","journal-title":"Med. Phys."},{"key":"dadf452bib24","doi-asserted-by":"publisher","first-page":"3874","DOI":"10.1364\/OL.43.003874","article-title":"Retrieval of weak x-ray scattering using edge illumination","volume":"43","author":"Maughan Jones","year":"2018","journal-title":"Opt. Lett."},{"key":"dadf452bib25","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1046\/j.1365-2818.2002.01010.x","article-title":"Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object","volume":"206","author":"Paganin","year":"2002","journal-title":"J. Microscopy"},{"key":"dadf452bib26","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevApplied.7.044020","article-title":"Single-shot x-ray phase-contrast computed tomography with nonmicrofocal laboratory sources","volume":"7","author":"Diemoz","year":"2017","journal-title":"Phys. Rev. Appl."},{"key":"dadf452bib27","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1002\/mp.14553","article-title":"Evaluation of a compact multicontrast and multiresolution x-ray phase contrast edge illumination system for small animal imaging","volume":"48","author":"Massimi","year":"2021","journal-title":"Med. Phys."},{"key":"dadf452bib28","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1109\/TMI.2021.3137964","article-title":"Volumetric high-resolution x-ray phase-contrast virtual histology of breast specimens with a compact laboratory system","volume":"41","author":"Massimi","year":"2022","journal-title":"IEEE Trans. Med. Imaging"},{"key":"dadf452bib29","doi-asserted-by":"publisher","first-page":"1945","DOI":"10.1364\/OL.445802","article-title":"Tomographic phase and attenuation extraction for a sample composed of unknown materials using x-ray propagation-based phase-contrast imaging","volume":"47","author":"Alloo","year":"2022","journal-title":"Opt. Lett."},{"key":"dadf452bib30","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.ultramic.2015.05.002","article-title":"The ASTRA toolbox: a platform for advanced algorithm development in electron tomography","volume":"157","author":"van Aarle","year":"2015","journal-title":"Ultramicroscopy"},{"key":"dadf452bib31","doi-asserted-by":"publisher","first-page":"25129","DOI":"10.1364\/OE.24.025129","article-title":"Fast and flexible x-ray tomography using the ASTRA toolbox","volume":"24","author":"van Aarle","year":"2016","journal-title":"Opt. Express"},{"key":"dadf452bib32","article-title":"AVIZO user\u2019s guide","author":"AVIZO","year":"2018"},{"key":"dadf452bib33","doi-asserted-by":"publisher","first-page":"1298","DOI":"10.1016\/j.medengphy.2013.02.001","article-title":"Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis","volume":"35","author":"Madi","year":"2013","journal-title":"Med. Eng. Phys."},{"key":"dadf452bib34","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1051\/meca\/2012025","article-title":"Digital volume correlation: what are the limits to the spatial resolution?","volume":"13","author":"Leclerc","year":"2012","journal-title":"Mech. Ind."},{"key":"dadf452bib35","doi-asserted-by":"publisher","DOI":"10.5522\/04\/28554059.v1","article-title":"CT reconstructions used to retrieve strain and assess strain retrieval precision in paper \u201cOn the applicability of X-ray strain imaging using the edge illumination technique in biomedical applications\u201d","author":"Peiffer","year":"2025"},{"key":"dadf452bib36","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/S0168-9002(97)00566-4","article-title":"X-ray microtomography scanner using time-delay integration for elimination of ring artefacts in the reconstructed image","volume":"394","author":"Davis","year":"1997","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"dadf452bib37","doi-asserted-by":"publisher","first-page":"3191","DOI":"10.1088\/0031-9155\/46\/12\/309","article-title":"A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results","volume":"46","author":"Doran","year":"2001","journal-title":"Phys. Med. Biol."},{"key":"dadf452bib38","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevApplied.10.054050","article-title":"Theoretical framework for spatial resolution in edge-illumination x-ray tomography","volume":"10","author":"Hagen","year":"2018","journal-title":"Phys. Rev. Appl."},{"key":"dadf452bib39","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevApplied.14.014069","article-title":"Cycloidal computed tomography","volume":"14","author":"Hagen","year":"2020","journal-title":"Phys. Rev. Appl."}],"container-title":["Journal of Physics D: Applied Physics"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,4]],"date-time":"2025-08-04T09:20:47Z","timestamp":1754299247000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6463\/adf452"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,4]]},"references-count":39,"journal-issue":{"issue":"31","published-online":{"date-parts":[[2025,8,4]]},"published-print":{"date-parts":[[2025,8,4]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6463\/adf452","relation":{},"ISSN":["0022-3727","1361-6463"],"issn-type":[{"value":"0022-3727","type":"print"},{"value":"1361-6463","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,4]]},"assertion":[{"value":"On the applicability of x-ray strain imaging using the edge illumination technique in biomedical applications","name":"article_title","label":"Article Title"},{"value":"Journal of Physics D: Applied Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-03-07","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-07-25","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-08-04","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}