{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,13]],"date-time":"2025-12-13T15:00:48Z","timestamp":1765638048318,"version":"3.48.0"},"reference-count":9,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2020,2,12]],"date-time":"2020-02-12T00:00:00Z","timestamp":1581465600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2020,2,12]],"date-time":"2020-02-12T00:00:00Z","timestamp":1581465600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["11605290"],"award-info":[{"award-number":["11605290"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100002855","name":"Ministry of Science and Technology of the People\u2019s Republic of China","doi-asserted-by":"crossref","award":["2012YQ180118"],"award-info":[{"award-number":["2012YQ180118"]}],"id":[{"id":"10.13039\/501100002855","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2020,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>When responding to nuclear and radiological emergencies, rapid and on-site detections of possible internal radioactive contaminants are required for early dose estimation and medical triage. Nasal swab analysis is an effective method to provide valuable information for early and fast estimates of alpha radionuclide inhalation intakes and resultant doses. In this study, to improve the quality of nasal swab measurements, a specialised double-detector alpha counter was designed. Various parameters including swab materials, sample pre-preparation, angle-dependence and vacuum dependence were investigated to optimise the reliability and convenience of the nasal swab method. An improved procedure of direct nasal swab measurement was eventually established, which could be used to obtain early data for initial dose assessment during the first response of nuclear and radiological emergencies.<\/jats:p>","DOI":"10.1088\/1361-6498\/ab6628","type":"journal-article","created":{"date-parts":[[2019,12,30]],"date-time":"2019-12-30T17:15:27Z","timestamp":1577726127000},"page":"270-279","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["An improved method of nasal swab analysis for assessing alpha internal radioactive contaminants"],"prefix":"10.1088","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7095-2360","authenticated-orcid":false,"given":"Ji","family":"Yunlong","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Dawei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qu","family":"Decheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ning","family":"Jing","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2020,2,12]]},"reference":[{"article-title":"Manual for first responders to a radiological emergency","year":"2006","author":"IAEA","key":"jrpab6628bib1","type":"report"},{"year":"2011","author":"USDHHS","key":"jrpab6628bib2","type":"other"},{"article-title":"Management of persons contaminated with radionuclides","year":"2008","author":"NCRP","key":"jrpab6628bib3","type":"report"},{"key":"jrpab6628bib4","first-page":"357","type":"conference-proceedings","article-title":"Application of nose swab to the assessment of internal contamination","author":"Miyabe","year":"1984"},{"key":"jrpab6628bib5","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1093\/rpd\/ncm354","type":"journal-article","article-title":"Technical basis for using nose swab bioassay data for early internal dose assessment","volume":"127","author":"Guilmette","year":"2007","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpab6628bib6","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1093\/rpd\/ncm295","type":"journal-article","article-title":"Practical action levels for chelation therapy in Plutonium inhalation using nose swab","volume":"127","author":"Kurihara","year":"2007","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpab6628bib7","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1088\/0952-4746\/32\/2\/155","type":"journal-article","article-title":"Optimisation of nasal swab analysis by liquid scintillation counting","volume":"32","author":"Dai","year":"2012","journal-title":"J. Radiol. Prot."},{"key":"jrpab6628bib8","first-page":"(2","type":"journal-article","article-title":"Occupational Intakes of Radionuclides: Part 4. ICRP Publication 141","volume":"48","author":"ICRP","year":"2012","journal-title":"Ann. ICRP"},{"article-title":"Early internal and external dose magnitude estimation","year":"2008","author":"ORISE","key":"jrpab6628bib9","type":"report"}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,13]],"date-time":"2025-12-13T14:57:03Z","timestamp":1765637823000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ab6628"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,12]]},"references-count":9,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,2,12]]},"published-print":{"date-parts":[[2020,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ab6628","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"type":"print","value":"0952-4746"},{"type":"electronic","value":"1361-6498"}],"subject":[],"published":{"date-parts":[[2020,2,12]]},"assertion":[{"value":"An improved method of nasal swab analysis for assessing alpha internal radioactive contaminants","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2020 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2019-09-21","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-12-30","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-02-12","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}