{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T06:39:36Z","timestamp":1793255976880,"version":"4.5.0"},"reference-count":41,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T00:00:00Z","timestamp":1614297600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T00:00:00Z","timestamp":1614297600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2021,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The radiation dose to the breasts should be kept to a minimum as breast tissues are highly sensitive to radiation. In mammography, the mean glandular dose (MGD) is used to specify the patient dose. In this study, data on the MGD during diagnostic mammographic examinations was collected using the database from six digital mammography facilities available in the Western Province in Sri Lanka. Examinations involving breast pathology, breast implants, or compressed breast thicknesses (CBT) outside the range of 20\u2013110\u2009mm were excluded in this study. The mean MGD per breast was 3.50\u2009mGy, with a mean CBT of 57\u2009mm. The mean MGD per facility varies from 1.58 to 2.27\u2009mGy, with overall 75th and 95th percentiles of 2.15 and 2.82\u2009mGy, respectively. The 75th and 95th percentile MGD per image, for the average CBT of 57\u2009\u00b1\u200912\u2009mm, were 2.00 and 2.65\u2009mGy respectively. The 75th percentile value of the MGD is suggested for the Western Province and it depends on the specific CBT.<\/jats:p>","DOI":"10.1088\/1361-6498\/abd075","type":"journal-article","created":{"date-parts":[[2020,12,3]],"date-time":"2020-12-03T17:31:18Z","timestamp":1607016678000},"page":"79-96","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["Establishment of regional diagnostic reference levels for digital mammography in Western Province of Sri Lanka"],"prefix":"10.1088","volume":"41","author":[{"given":"H S","family":"Niroshani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2896-3768","authenticated-orcid":false,"given":"Jeyasingam","family":"Jeyasugiththan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G","family":"Senanayake","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toru","family":"Negishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2021,2,26]]},"reference":[{"key":"jrpabd075bib1","doi-asserted-by":"publisher","first-page":"205","DOI":"10.7326\/M15-1241","type":"journal-article","article-title":"Radiation-induced breast cancer incidence and mortality from digital mammography screening: a modeling study","volume":"164","author":"Miglioretti","year":"2016","journal-title":"Ann. Intern. Med."},{"key":"jrpabd075bib2","doi-asserted-by":"publisher","first-page":"541","DOI":"10.3238\/arztebl.2008.0541","type":"journal-article","article-title":"Imaging studies for the early detection of breast cancer","volume":"37","author":"Heywang-Kobrunner","year":"2008","journal-title":"Deutsches Arzteblatt Int."},{"key":"jrpabd075bib3","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1007\/s00330-017-5024-4","type":"journal-article","article-title":"Radiation dose with digital breast tomosynthesis compared to digital mammography: per-view analysis","volume":"28","author":"Gennaro","year":"2018","journal-title":"Eur. Radiol."},{"key":"jrpabd075bib4","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/s13058-015-0525-z","type":"journal-article","article-title":"Benefits and harms of mammography screening","volume":"17","author":"Loberg","year":"2015","journal-title":"Breast Cancer Res."},{"key":"jrpabd075bib5","doi-asserted-by":"publisher","DOI":"10.1063\/1.5004297","type":"journal-article","article-title":"Estimation of mean glandular dose for patients who undergo mammography and studying the factor affecting it","volume":"1888","author":"Barzanje","year":"2017","journal-title":"AIP Conf. Proc."},{"key":"jrpabd075bib6","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1093\/rpd\/ncz005","type":"journal-article","article-title":"Institutional breast doses in digital mammography","volume":"185","author":"Lekatou","year":"2019","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpabd075bib7","first-page":"23","type":"journal-article","article-title":"Evaluation of mean glandular dose and modulation transfer function for different tube potentials and target-filter combinations in computed radiography mammography","volume":"20","author":"Abdul Aziz","year":"2013","journal-title":"Malaysian J. Med. Sci."},{"key":"jrpabd075bib8","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1088\/0031-9155\/35\/9\/002","type":"journal-article","article-title":"Monte-Carlo calculation of conversion factors for the estimation of mean glandular breast dose","volume":"35","author":"Dance","year":"1990","journal-title":"Phys. Med. Biol."},{"key":"jrpabd075bib9","article-title":"Benefit and risk in breast screening","author":"Law","type":"other"},{"key":"jrpabd075bib10","author":"Public health functions to be exercised by NHS England Service specification 24","type":"other"},{"key":"jrpabd075bib11","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1148\/radiol.10100655","type":"journal-article","article-title":"Risk of radiation-induced breast cancer from mammographic screening","volume":"258","author":"Yaffe","year":"2011","journal-title":"Radiology"},{"key":"jrpabd075bib12","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1093\/rpd\/ncu365","type":"journal-article","article-title":"Diagnostic reference levels in digital mammography: a systematic review","volume":"167","author":"Suleiman","year":"2015","journal-title":"Radiat. Prot. Dosimetry"},{"key":"jrpabd075bib13","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1148\/radiology.193.1.8090926","type":"journal-article","article-title":"Normalized average glandular dose in molybdenum target rhodium filter and rhodium target-rhodium filter mammography","volume":"193","author":"Wu","year":"1994","journal-title":"Radiology"},{"key":"jrpabd075bib14","doi-asserted-by":"publisher","first-page":"1863","DOI":"10.1118\/1.598100","type":"journal-article","article-title":"Molybdenum, rhodium and tungsten anode spectral models using interpolating polynomials with application to mammography","volume":"24","author":"Boone","year":"1997","journal-title":"Med. Phys."},{"key":"jrpabd075bib15","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1088\/1361-6498\/ab0b28","type":"journal-article","article-title":"Mean glandular dose in digital mamography in women with breast implants","volume":"39","author":"Couto","year":"2019","journal-title":"J. Radiol. Prot."},{"key":"jrpabd075bib16","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1093\/rpd\/nct051","type":"journal-article","article-title":"Mammography equipment performance, image quality and mean glandular dose in Malta","volume":"156","author":"Borg","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpabd075bib17","doi-asserted-by":"crossref","first-page":"A123-A132","DOI":"10.1088\/0952-4746\/29\/2A\/S08","type":"journal-article","article-title":"Mammography\u2014oncogenicity at low doses","volume":"29","author":"Heyes","year":"2009","journal-title":"J. Radiol. Prot."},{"key":"jrpabd075bib18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","type":"journal-article","article-title":"ICRP publication 135: diagnostic reference levels in medical imaging","volume":"46","author":"Vano","year":"2017","journal-title":"Ann. ICRP"},{"key":"jrpabd075bib19","doi-asserted-by":"publisher","first-page":"3225","DOI":"10.1088\/0031-9155\/45\/11\/308","type":"journal-article","article-title":"Additional factors for estimation of mean glandular breast dose using the UK mammography dosimetry protocol","volume":"45","author":"Dance","year":"2000","journal-title":"Phys. Med. Biol."},{"key":"jrpabd075bib20","article-title":"Diagnostic Reference Level position paper","author":"Medical Council Ireland","year":"2004","type":"other"},{"key":"jrpabd075bib21","doi-asserted-by":"publisher","first-page":"54","DOI":"10.4103\/ajmhs.ajmhs_43_17","type":"journal-article","article-title":"Diagnostic reference levels for mammography examinations in north eastern Nigeria","volume":"17","author":"Joseph","year":"2018","journal-title":"African J. Med. Health Sci."},{"key":"jrpabd075bib22","article-title":"Malaysian diagnostic reference levels in imaging medical (Radiology)","author":"Malaysian Ministry of Health (MOH)","year":"2013","type":"other"},{"key":"jrpabd075bib23","author":"Magny","year":"2020","type":"book"},{"key":"jrpabd075bib24","author":"ACR BI-RADS Atlas\u00ae","year":"2013","edition":"5th edn","type":"book"},{"key":"jrpabd075bib25","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1111\/1754-9485.12540","type":"journal-article","article-title":"Diagnostic reference levels for digital mammography in New South Wales","volume":"61","author":"Suleiman","year":"2016","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"jrpabd075bib26","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1093\/rpd\/ncn152","type":"journal-article","article-title":"Results of a European dose survey for mammography","volume":"129","author":"Michielsen","year":"2008","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpabd075bib27","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1093\/rpd\/ncs317","type":"journal-article","article-title":"Towards proposition of a diagnostic reference level for mammographic examination in the greater Khorasan Province, Iran","volume":"155","author":"Bahreyni Toossi","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpabd075bib28","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1093\/rpd\/ncs112","type":"journal-article","article-title":"A comparison of mean glandular dose diagnostic reference levels within the all-digital irish national breast screening programme and the irish symptomatic breast services","volume":"153","author":"O\u2019Leary","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpabd075bib29","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1007\/s12194-013-0239-9","type":"journal-article","article-title":"Patient investigation of average glandular dose and incident air kerma for digital mammography","volume":"7","author":"Kawaguchi","year":"2014","journal-title":"Radiol. Phys. Technol."},{"key":"jrpabd075bib30","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1088\/0952-4746\/34\/1\/125","type":"journal-article","article-title":"Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan","volume":"34","author":"Asada","year":"2014","journal-title":"J. Radiol. Prot."},{"key":"jrpabd075bib31","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1259\/bjr\/66428508","type":"journal-article","article-title":"A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it","volume":"76","author":"Jamal","year":"2003","journal-title":"Br. J. Radiol."},{"key":"jrpabd075bib32","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/j.radi.2009.05.002","type":"journal-article","article-title":"Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria","volume":"15","author":"Ogundare","year":"2009","journal-title":"Radiography"},{"key":"jrpabd075bib33","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1093\/rpd\/nct136","type":"journal-article","article-title":"New diagnostic reference level for full-field digital mammography units","volume":"157","author":"Hauge","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpabd075bib34","doi-asserted-by":"publisher","first-page":"2471","DOI":"10.1118\/1.1784591","type":"journal-article","article-title":"Patient dose in digital mammography","volume":"31","author":"Chevalier","year":"2004","journal-title":"Med. Physics."},{"key":"jrpabd075bib35","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1259\/bjr\/41095952","type":"journal-article","article-title":"Radiation doses received in the UK Breast Screening Programme in 2001 and 2002","volume":"78","author":"Young","year":"2005","journal-title":"Br. J. Radiol."},{"key":"jrpabd075bib36","article-title":"Breastcharacteristics and dosimetric data in X-ray mammography a large sample worldwide survey","author":"Geeraert","year":"2012","type":"conference-proceedings"},{"key":"jrpabd075bib37","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1093\/rpd\/ncq375","type":"journal-article","article-title":"Comprehensive dose survey of breast screening in Ireland","volume":"145","author":"Baldelli","year":"2011","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpabd075bib38","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1111\/tbj.12833","type":"journal-article","article-title":"Do women with dense breasts have higher radiation dose during screening mammography?","volume":"24","author":"Nguyen","year":"2018","journal-title":"Breast J."},{"key":"jrpabd075bib39","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/s12957-017-1107-6","type":"journal-article","article-title":"Radiation dose affected by mammographic composition and breast size: first application of a radiation dose management system for full-field digital mammography in Korean women","volume":"15","author":"Baek","year":"2017","journal-title":"World J. Surgical Oncol."},{"key":"jrpabd075bib40","author":"Japan DRLs","year":"2015","type":"other"},{"key":"jrpabd075bib41","doi-asserted-by":"publisher","first-page":"36","DOI":"10.18203\/issn.0019-5359.IndianJMedSci20163529","type":"journal-article","article-title":"Suggested diagnostic reference level for mammography examination in Ethiopia","volume":"68","author":"Dellie","year":"2016","journal-title":"Indian J. Med. Sci."}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T14:16:05Z","timestamp":1764425765000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/abd075"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,26]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,2,26]]},"published-print":{"date-parts":[[2021,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/abd075","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,26]]},"assertion":[{"value":"Establishment of regional diagnostic reference levels for digital mammography in Western Province of Sri Lanka","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-09-30","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-12-03","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-02-26","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}