{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T03:32:03Z","timestamp":1793331123774,"version":"4.5.0"},"reference-count":44,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2022,7,11]],"date-time":"2022-07-11T00:00:00Z","timestamp":1657497600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2022,7,11]],"date-time":"2022-07-11T00:00:00Z","timestamp":1657497600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2022,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This work focuses on the determination of the radiation doses for a total sample of 916 children, categorised into four age groups (&lt;1, 1\u20135, &lt;5\u201310, &lt;10\u201315 years) undergoing the most frequent paediatric CT scans performed in different scan facilities in Tunisia in order to establish the national diagnostic reference levels (DRLs). Dose evaluation concerned the dosimetric indicators: volume computed tomography dose index (CTDI<jats:sub>vol)<\/jats:sub> and dose\u2013length product (DLP). The different paediatric CT protocols and practices were also evaluated. The results show a large variation in doses between different radiology departments. For head scans, the respective DRLs for children aged &lt;1, 1\u20135, 5\u201310 and 10\u201315 years were 26, 38, 51 and 51 mGy, respectively, for CTDI<jats:sub>vol<\/jats:sub> and 384, 664, 873 and 978 mGy cm, respectively, for DLP. For the chest, the equivalent respective DRLs were 8, 10, 12 and 15 mGy for CTDI<jats:sub>vol<\/jats:sub> and 118, 330, 442 and 526 mGy cm for DLP. For the abdomen, the respective DRLs were 9, 13, 19 and 18 mGy for CTDI<jats:sub>vol<\/jats:sub> and 353, 485, 592 and 1073 mGy cm for DLP. This study shows that the optimisation of paediatric CT procedures should be a priority, especially within regional hospitals. The implementation of corrective actions will take place after the initial DRLs. These actions, including recommendations and guidelines to good practice, should be a joint effort of all stakeholders, including health authorities, the radiation protection regulator, professional societies and universities.<\/jats:p>","DOI":"10.1088\/1361-6498\/ac767a","type":"journal-article","created":{"date-parts":[[2022,6,7]],"date-time":"2022-06-07T18:22:42Z","timestamp":1654626162000},"page":"031503","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Towards the establishment of national diagnostic reference levels in Tunisia: a multicentre survey in paediatric CT"],"prefix":"10.1088","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3179-6470","authenticated-orcid":true,"given":"Abir","family":"Bouaoun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Latifa","family":"Ben Omrane","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wi\u00e8m","family":"Douira Khomssi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2022,7,11]]},"reference":[{"key":"jrpac767abib1","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","type":"journal-article","article-title":"Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study","volume":"380","author":"Pearce","year":"2012","journal-title":"The Lancet"},{"key":"jrpac767abib2","article-title":"Medical radiation exposure of the European population. Radiation Protection 180 part 1\/2","author":"European Commission","year":"2014","type":"web-resource"},{"key":"jrpac767abib3","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1051\/radiopro\/2017002","type":"journal-article","article-title":"Exposure of the French population to ionizing radiations from medical diagnostic procedures in 2012","volume":"52","author":"Dreuil","year":"2017","journal-title":"Radioprotection"},{"key":"jrpac767abib4","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1007\/s00247-011-2154-8","type":"journal-article","article-title":"ALARA (as low as reasonably achievable) CT 2011\u2014executive summary","volume":"41","author":"Newman","year":"2011","journal-title":"Pediatr. Radiol."},{"key":"jrpac767abib5","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/s00330-012-2639-3","type":"journal-article","article-title":"IAEA survey of paediatric computed tomography practice in 40 countries in Asia, Europe, Latin America and Africa: procedures and protocols","volume":"23","author":"Vassileva","year":"2013","journal-title":"Eur. Radiol."},{"key":"jrpac767abib6","article-title":"Guide de bonne pratique en TDM chez l\u2019enfant","author":"Soci\u00e9t\u00e9 Francophone d\u2019Imagerie P\u00e9diatrique et Pr\u00e9natale (SFIPP)","year":"2014","type":"web-resource"},{"key":"jrpac767abib7","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1007\/s00247-011-2169-1","type":"journal-article","article-title":"Advances in CT technology and application to pediatric imaging","volume":"41","author":"Mahesh","year":"2011","journal-title":"Pediatr. Radiol."},{"key":"jrpac767abib8","doi-asserted-by":"publisher","first-page":"950","DOI":"10.2214\/AJR.12.9026","type":"journal-article","article-title":"Pediatric CT: strategies to lower radiation dose","volume":"200","author":"Zacharias","year":"2013","journal-title":"AJR Am. J. Roentgenol."},{"key":"jrpac767abib9","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/j.jmir.2015.03.003","type":"journal-article","article-title":"Pediatric computed tomography dose optimization strategies: a literature review","volume":"46","author":"AlMahrooqi","year":"2015","journal-title":"J. Med. Imaging Radiat. Sci."},{"key":"jrpac767abib10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0146-6453(00)89195-2","type":"journal-article","article-title":"Radiological protection and safety in medicine. ICRP Publication 73","volume":"26","author":"ICRP","year":"1996","journal-title":"Ann. ICRP"},{"key":"jrpac767abib11","first-page":"1","type":"journal-article","article-title":"The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication 103","volume":"37","author":"ICRP","year":"2007","journal-title":"Ann. ICRP"},{"key":"jrpac767abib12","author":"International Atomic Energy Agency","year":"2018","type":"book"},{"key":"jrpac767abib13","article-title":"Council Directive 2013\/59\/Euratom of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation, and repealing Directives 89\/618\/Euratom, 90\/641\/Euratom, 96\/29\/Euratom, 97\/43\/Euratom and 2003\/122\/Euratom","author":"European Commission","year":"2014","type":"other"},{"key":"jrpac767abib14","author":"European Commission","year":"1999","type":"report"},{"key":"jrpac767abib15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/0146645317717209","type":"journal-article","article-title":"Diagnostic reference levels in medical imaging. ICRP Publication 135","volume":"46","author":"International Commission on Radiological Protection (ICRP)","year":"2017","journal-title":"Ann. ICRP"},{"key":"jrpac767abib16","author":"European Commission (EC)","year":"2018","type":"book"},{"key":"jrpac767abib17","first-page":"1","type":"journal-article","article-title":"Managing patient dose in computed tomography. ICRP Publication 87","volume":"30","author":"International Commission on Radiological Protection","year":"2001","journal-title":"Ann. ICRP"},{"key":"jrpac767abib18","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1136\/bmj.320.7235.593","type":"journal-article","article-title":"Radiation doses in computed tomography","volume":"320","author":"Rehani","year":"2000","journal-title":"BMJ"},{"key":"jrpac767abib19","doi-asserted-by":"publisher","first-page":"303","DOI":"10.2214\/ajr.176.2.1760303","type":"journal-article","article-title":"Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large children\u2019s hospital","volume":"176","author":"Donnelly","year":"2001","journal-title":"Am. J. Roentgenol."},{"key":"jrpac767abib20","article-title":"Optimization of the Radiological Protection of Patient Undergoing Radiography, Fluoroscopy and Computed Tomography: Final Report of a Coordinated Research Project in Africa, Asia and Eastern Europe IAEA TEC DOC-1423","author":"International Atomic Energy Agency","year":"2004","type":"report"},{"key":"jrpac767abib21","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1093\/rpd\/ncq015","type":"journal-article","article-title":"Paediatric CT examinations in 19 developing countries: frequency and radiation dose","volume":"140","author":"Muhogora","year":"2010","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpac767abib22","doi-asserted-by":"publisher","first-page":"3327","DOI":"10.14319\/ijcto.33.27","type":"journal-article","article-title":"A survey of paediatric CT radiation doses in two selected hospitals in Kampala, Uganda: a radiation safety concern","volume":"3","author":"Kisembo","year":"2015","journal-title":"Int. J. Cancer Ther. Oncol."},{"key":"jrpac767abib23","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1051\/radiopro\/2012016","type":"journal-article","article-title":"\u00c9valuation de la dose patient en scanographie p\u00e9diatrique dans deux h\u00f4pitaux universitaires \u00e0 Yaound\u00e9 Cameroun","volume":"47","author":"Ongolo-Zogo","year":"2012","journal-title":"Radioprotection"},{"key":"jrpac767abib24","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1093\/rpd\/ncu321","type":"journal-article","article-title":"Radiation exposure during paediatric CT in sudan: CT dose, organ and effective doses","volume":"167","author":"Suliman","year":"2014","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpac767abib25","doi-asserted-by":"publisher","first-page":"56","DOI":"10.19044\/esj.2016.v12n6p56","type":"journal-article","article-title":"Revue des doses d\u2019exposition et des m\u00e9thode d\u2019optimisation en tomodensitom\u00e9trie (TDM) de l\u2019enfant au Togo","volume":"12","author":"Tchaou","year":"2016","journal-title":"Eur. Sci. J."},{"key":"jrpac767abib26","article-title":"Pediatric computed tomography doses at the University Children\u2019s Hospital of Tunis","author":"Ben Omrane","year":"2014","type":"conference-proceedings"},{"key":"jrpac767abib27","first-page":"541","type":"conference-proceedings","article-title":"Paediatric head CT examination doses in two university teaching hospitals in Tunisia","author":"Bouaoun","year":"2017"},{"key":"jrpac767abib28","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1093\/rpd\/ncy055","type":"journal-article","article-title":"Pediatric head CT exposure doses in Tunisia: a pilot study towards the establishment of national diagnostic reference levels","volume":"182","author":"Bouaoun","year":"2018","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpac767abib29","article-title":"Sanitary map of Tunisia","author":"Ministry of Public Health, Tunisia","year":"2015","type":"web-resource"},{"key":"jrpac767abib30","article-title":"Measurement protocol Version 5.0","author":"ImPACT CT Scanner Dose Survey","year":"1997","type":"report"},{"key":"jrpac767abib31","first-page":"1","type":"journal-article","article-title":"Dosimetry in diagnostic radiology: an international code of practice","volume":"457","author":"International Atomic Energy Agency (IAEA)","year":"2007","journal-title":"TRS N\u00b0"},{"key":"jrpac767abib32","author":"Buls","year":"2010","type":"report"},{"key":"jrpac767abib33","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1259\/bjr\/93277434","type":"journal-article","article-title":"National survey of doses from CT in the UK: 2003","volume":"79","author":"Shrimpton","year":"2006","journal-title":"Br. J. Radiol."},{"key":"jrpac767abib34","article-title":"The measurement, reporting, and management of radiation dose in CT. AAPM Report 96","author":"American Association of Physicists in Medicine (AAPM)","year":"2008","type":"report"},{"key":"jrpac767abib35","author":"American Association of Physicists in Medicine (AAPM)","year":"2011","type":"report"},{"key":"jrpac767abib36","author":"United Nations Scientific Committee on the Effect of Atomic Radiation (UNSCEAR)","year":"2000","type":"report"},{"key":"jrpac767abib37","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1093\/rpd\/ncv116","type":"journal-article","article-title":"A study to establish international diagnostic reference levels for paediatric computed tomography","volume":"165","author":"Vassileva","year":"2015","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpac767abib38","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1055\/a-0824-7603","type":"journal-article","article-title":"Diagnostic reference levels for diagnostic and interventional x-ray procedures in Germany: update and handling","volume":"191","author":"Schegerer","year":"2019","journal-title":"Rofo"},{"key":"jrpac767abib39","author":"National Diagnostic Reference Levels in Japan","year":"2020","type":"web-resource"},{"key":"jrpac767abib40","author":"The Federal Agency for Nuclear Control (FANC), Belgium","year":"2020","type":"web-resource"},{"key":"jrpac767abib41","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.radmp.2021.02.001","type":"journal-article","article-title":"A multi-provincial survey and analysis of radiation doses from pediatric CT in China","volume":"2","author":"Kang","year":"2021","journal-title":"Radiat. Med. Prot."},{"key":"jrpac767abib42","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1118\/1.2710331","type":"journal-article","article-title":"Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations","volume":"34","author":"Tzedakis","year":"2007","journal-title":"Med. Phys."},{"key":"jrpac767abib43","first-page":"1","type":"journal-article","article-title":"Recommendations of the International Commission on Radiological Protection. Publication 60","volume":"21","author":"International Commission on Radiological Protection","year":"1990","journal-title":"Ann. ICRP"},{"key":"jrpac767abib44","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1148\/radiol.2021211241","type":"journal-article","article-title":"U.S. diagnostic reference levels and achievable doses for 10 pediatric CT examinations","volume":"302","author":"Kanal","year":"2021","journal-title":"Radiology"}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T11:36:58Z","timestamp":1760787418000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ac767a"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,11]]},"references-count":44,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022,7,11]]},"published-print":{"date-parts":[[2022,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ac767a","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,11]]},"assertion":[{"value":"Towards the establishment of national diagnostic reference levels in Tunisia: a multicentre survey in paediatric CT","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2022-01-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-06-07","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-07-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}