{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T18:40:25Z","timestamp":1783536025744,"version":"3.55.0"},"reference-count":44,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2024,5,28]],"date-time":"2024-05-28T00:00:00Z","timestamp":1716854400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,5,28]],"date-time":"2024-05-28T00:00:00Z","timestamp":1716854400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"FACEPE- Foundation for the Support of Science and Technology of the State of Pernambuco","award":["processes: IBPG-1429-3.09\/22 and BIC-0941-3.09\/22"],"award-info":[{"award-number":["processes: IBPG-1429-3.09\/22 and BIC-0941-3.09\/22"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2024,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician\u2019s hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.<\/jats:p>","DOI":"10.1088\/1361-6498\/ad4905","type":"journal-article","created":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T10:41:11Z","timestamp":1715251271000},"page":"021516","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Medical staff dose estimation during pediatric cardiac interventional procedures"],"prefix":"10.1088","volume":"44","author":[{"given":"Maryanna Regina","family":"Roberto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luiz M A","family":"Leite","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ar\u00edcia R P","family":"Cruz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7257-0959","authenticated-orcid":true,"given":"Helen","family":"Khoury","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7617-454X","authenticated-orcid":false,"given":"Vin\u00edcius S M","family":"de Barros","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juliana R","family":"Neves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00e9ssica M","family":"Cartaxo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2565-5850","authenticated-orcid":false,"given":"Carlos","family":"Ubeda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7549-4522","authenticated-orcid":false,"given":"Viviane K","family":"Asfora","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,5,28]]},"reference":[{"key":"jrpad4905bib1","doi-asserted-by":"publisher","first-page":"E85","DOI":"10.1161\/CIRCULATIONAHA.105.171600","article-title":"Heart disease and stroke statistics\u20142006, a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee","volume":"113","author":"Thom","year":"2006","journal-title":"Circulation"},{"key":"jrpad4905bib2","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1016\/j.ehj.2004.04.024","volume":"25","author":"Togni","year":"2004","journal-title":"Eur. Heart J."},{"key":"jrpad4905bib3","author":"United Nations Scientific Committee on Atomic Radiation (UNSCEAR)","year":"2013"},{"key":"jrpad4905bib4","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1259\/bjr.73.871.11089467","volume":"73","author":"Mooney","year":"2000","journal-title":"Br. J. Radiol."},{"key":"jrpad4905bib5","doi-asserted-by":"publisher","first-page":"3","DOI":"10.2214\/ajr.177.1.1770003","volume":"177","author":"Koenig","year":"2001","journal-title":"Am. J. Roentgenol."},{"key":"jrpad4905bib6","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1002\/1522-726X(200102)52:2<235::AID-CCD1056>3.0.CO;2-J","volume":"52","author":"Schmoor","year":"2001","journal-title":"Cardiovasc. Interv."},{"key":"jrpad4905bib7","doi-asserted-by":"publisher","first-page":"13","DOI":"10.2214\/ajr.177.1.1770013","volume":"177","author":"Koenig","year":"2001","journal-title":"Am. J. Roentgenol."},{"key":"jrpad4905bib8","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.ijcard.2005.06.015","volume":"109","author":"Rehani","year":"2006","journal-title":"Int. J. Cardiol."},{"key":"jrpad4905bib9","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1016\/S1051-0443(07)61742-4","volume":"13","author":"Fletcher","year":"2002","journal-title":"J. Vascular Int. Radiol."},{"key":"jrpad4905bib10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.10.001","article-title":"International commission on radiological protection. Radiological protection in paediatric diagnostic and interventional radiology. ICRP publication 121","volume":"42","author":"Khong","year":"2013","journal-title":"Ann. ICRP"},{"key":"jrpad4905bib11","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1259\/bjr.71.847.9771383","volume":"71","author":"Vano","year":"1998","journal-title":"Br. J. Radiol."},{"key":"jrpad4905bib12","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1148\/radiol.2482071800","volume":"248","author":"Vano","year":"2008","journal-title":"Radiology"},{"key":"jrpad4905bib13","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1667\/RR2207.1","volume":"174","author":"Vano","year":"2010","journal-title":"Radiat. Res."},{"key":"jrpad4905bib14","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1002\/ccd.22670","volume":"76","author":"Ciraj-Bjelac","year":"2010","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"jrpad4905bib15","first-page":"108","volume":"83","author":"Pages","year":"2000","journal-title":"JBR-BTR"},{"key":"jrpad4905bib16","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1093\/rpd\/ncv051","volume":"165","author":"Principi","year":"2015","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpad4905bib17","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1088\/0952-4746\/36\/1\/133","volume":"36","author":"Sanchez","year":"2016","journal-title":"J. Radiol. Prot."},{"key":"jrpad4905bib18","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s00246-008-9375-0","volume":"30","author":"Vano","year":"2009","journal-title":"Pediatr. Cardiol."},{"key":"jrpad4905bib19","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1093\/rpd\/ncq039","volume":"140","author":"Ubeda","year":"2010","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpad4905bib20","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1093\/rpd\/nct118","volume":"157","author":"Ubeda","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpad4905bib21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/rpd\/ncx031","article-title":"Characterization and experimental measurements of scatter dose at cardiologist\u2019s eyes during paediatric interventional cardiology procedures in costa rica","volume":"176","author":"Ubeda","year":"2017","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpad4905bib22","author":"IEC","year":"2010","edition":"2nd edn"},{"key":"jrpad4905bib23","author":"ICRU Report 74","year":"2005"},{"key":"jrpad4905bib24","article-title":"International organization for standarization","author":"ISO 4037-1","year":"1996"},{"key":"jrpad4905bib25","article-title":"Guide to expression of uncertainty in measurement","author":"ISO\/IEC Guide 98-3","year":"2008"},{"key":"jrpad4905bib26","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1097\/HP.0b013e3181e850da","volume":"99","author":"von Boetticher","year":"2010","journal-title":"Health Phys."},{"key":"jrpad4905bib27","author":"International Atomic Energy Agency","year":"2013"},{"key":"jrpad4905bib28","author":"Vanhavere","year":"2012"},{"key":"jrpad4905bib29","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1111\/1754-9485.13307","volume":"66","author":"Moriarty","year":"2022","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"jrpad4905bib30","article-title":"Official Journal of the European Union","author":"Euratom","year":"2013"},{"key":"jrpad4905bib31","doi-asserted-by":"publisher","first-page":"1956","DOI":"10.1002\/mp.14753","volume":"48","author":"Morcillo","year":"2021","journal-title":"Med. Phys."},{"key":"jrpad4905bib32","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1093\/rpd\/ncac064","volume":"198","author":"Morcillo","year":"2022","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpad4905bib33","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1093\/rpd\/ncp168","volume":"136","author":"Martin","year":"2009","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpad4905bib34","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1093\/rpd\/ncs236","volume":"154","author":"Antic","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpad4905bib35","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ejmp.2022.04.005","volume":"98","author":"Pekkarinen","year":"2022","journal-title":"Phys. Med."},{"key":"jrpad4905bib36","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1088\/1361-6498\/abc4d7","volume":"40","author":"S\u00e1nchez","year":"2020","journal-title":"J. Radiol. Prot."},{"key":"jrpad4905bib37","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1259\/bjr\/83222759","volume":"84","author":"Efstathopoulos","year":"2011","journal-title":"Br. J. Radiol."},{"key":"jrpad4905bib38","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1093\/rpd\/ncy085","volume":"182","author":"Rizk","year":"2018","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpad4905bib39","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.ejmp.2017.03.015","volume":"36","author":"Alejo","year":"2017","journal-title":"Phys. Med."},{"key":"jrpad4905bib40","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.apradiso.2016.01.013","volume":"117","author":"Leyton","year":"2016"},{"key":"jrpad4905bib41","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1590\/0104-1843000000015","volume":"22","author":"Leyton","year":"2014","journal-title":"Rev. Bras. Cardiol. Invasiva"},{"key":"jrpad4905bib42","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1088\/0952-4746\/36\/1\/37","volume":"36","author":"Vano","year":"2016","journal-title":"J. Radiol. Prot."},{"key":"jrpad4905bib43","doi-asserted-by":"publisher","first-page":"138","DOI":"10.2214\/AJR.11.8455","volume":"200","author":"Chida","year":"2013","journal-title":"Am. J. Roentgenol."},{"key":"jrpad4905bib44","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1093\/rpd\/ncp052","volume":"133","author":"Kim","year":"2009","journal-title":"Radiat. Prot. Dosim."}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,23]],"date-time":"2025-08-23T10:52:13Z","timestamp":1755946333000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ad4905"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,28]]},"references-count":44,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,5,28]]},"published-print":{"date-parts":[[2024,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ad4905","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,28]]},"assertion":[{"value":"Medical staff dose estimation during pediatric cardiac interventional procedures","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-12-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-09","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-28","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}