{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T09:40:52Z","timestamp":1763718052178,"version":"3.45.0"},"reference-count":51,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T00:00:00Z","timestamp":1763683200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T00:00:00Z","timestamp":1763683200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2025,12,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Epidural blocks are commonly performed interventional pain procedures under C-arm fluoroscopic guidance. However, radiation exposure to the ocular lens remains a significant concern due to its high radiosensitivity and the associated risk of radiation-induced cataract formation. Therefore, this study aims to quantify ocular lens dose during cervical and lumbar epidural blocks (CEBs and LEBs), and to evaluate the shielding efficacy of 0.5 mmPb lead-free radiation-protective eyewear (R-PEW), using a quantitative, phantom-based experimental design that simulates realistic clinical scenarios based on exposure conditions derived from 150 real patients. An adult anthropomorphic phantom was used, and ocular lens doses were recorded with optically stimulated luminescence dosimeters under six experimental conditions defined based on procedure type, patient position, and eyewear status. Without shielding, the maximum lens dose was 1.90 mSv during prone CEBs, while the greatest reduction with R-PEW was 83.3% during prone LEBs. Dose asymmetry between the right and left eyes corresponded to differences in source-to-eye distance. All measured doses were substantially below the cataract threshold (0.5 Gy) and the International Commission on Radiological Protection annual public equivalent dose limit for the lens of the eye (15 mSv). Nonetheless, R-PEW consistently reduced exposure under all conditions, offering additional protection in accordance with the optimisation principle. These findings suggest that, although routine patient shielding is not warranted given the low absolute doses, R-PEW represents a simple and effective adjunct to further minimise ocular exposure during C-arm-guided epidural blocks.<\/jats:p>","DOI":"10.1088\/1361-6498\/ae1e05","type":"journal-article","created":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T22:48:36Z","timestamp":1762901316000},"page":"041515","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Eye lens dose and shielding efficacy of radiation-protective eyewear in C-arm\u2013guided cervical and lumbar epidural blocks: a phantom study"],"prefix":"10.1088","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7474-9127","authenticated-orcid":true,"given":"Do-Byung","family":"Rhee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-6496-3504","authenticated-orcid":true,"given":"Ji-Won","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-9095-8672","authenticated-orcid":true,"given":"Il-Hwan","family":"Bae","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4368-8541","authenticated-orcid":true,"given":"Hee-June","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9686-9955","authenticated-orcid":true,"given":"Jin-Seok","family":"Yeo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2025,11,21]]},"reference":[{"key":"jrpae1e05bib1","doi-asserted-by":"publisher","first-page":"m791","DOI":"10.1136\/bmj.m791","type":"journal-article","article-title":"Global, regional, and national burden of neck pain in the general population, 1990\u20132017: systematic analysis of the Global Burden of Disease Study 2017","volume":"368","author":"Safiri","year":"2020","journal-title":"BMJ"},{"key":"jrpae1e05bib2","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1001\/jama.2013.13805","type":"journal-article","article-title":"The state of US health, 1990\u20132010: burden of diseases, injuries, and risk factors","volume":"310","author":"Murray","year":"2013","journal-title":"JAMA"},{"article-title":"Interventional fluoroscopy: reducing radiation risks for patients and staff","year":"2005","author":"National Cancer Institute, Society of Interventional Radiology","key":"jrpae1e05bib3","type":"report"},{"key":"jrpae1e05bib4","doi-asserted-by":"publisher","first-page":"e135","DOI":"10.1002\/acm2.13526","type":"journal-article","article-title":"AAPM Medical physics practice guideline 12.a: fluoroscopy","volume":"49","author":"Fisher","year":"2022","journal-title":"Med. Phys."},{"article-title":"Notable trends and advancements in mobile C-arms Imaging","year":"2024","author":"Taschetta-Millane","key":"jrpae1e05bib5","type":"web-resource"},{"article-title":"Radiation safety. Treasure Island (FL): statPearls publishing","year":"2025","author":"StatPearls","key":"jrpae1e05bib6","type":"web-resource"},{"key":"jrpae1e05bib7","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1093\/eurheartj\/eht394","type":"journal-article","article-title":"The appropriate and justified use of medical radiation in cardiovascular imaging: a position document of the ESC associations of cardiovascular imaging, percutaneous cardiovascular interventions and electrophysiology","volume":"35","author":"Picano","year":"2014","journal-title":"Eur. Heart J."},{"key":"jrpae1e05bib8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.pmr.2017.08.001","type":"journal-article","article-title":"Cervical epidural steroid injection: techniques and evidence","volume":"29","author":"House","year":"2018","journal-title":"Phys. Med. Rehabil. Clin. North Am."},{"key":"jrpae1e05bib9","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.bjae.2021.12.006","type":"journal-article","article-title":"Update on applied epidural anatomy","volume":"22","author":"Macpherson","year":"2022","journal-title":"BJA. Educ."},{"key":"jrpae1e05bib10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317750356","type":"journal-article","article-title":"ICRP Publication 139: occupational radiological protection in interventional procedures","volume":"47(2)","author":"L\u00f3pez","year":"2018","journal-title":"Ann. ICRP"},{"key":"jrpae1e05bib11","doi-asserted-by":"publisher","first-page":"aca2b3","DOI":"10.1088\/1361-6498\/aca2b3","type":"journal-article","article-title":"Current status of diagnostic reference levels in interventional cardiology","volume":"42","author":"S\u00e1nchez","year":"2022","journal-title":"J. Radiol. Prot."},{"key":"jrpae1e05bib12","doi-asserted-by":"publisher","first-page":"129","DOI":"10.3344\/kjp.2022.35.2.129","type":"journal-article","article-title":"Radiation safety for pain physicians: principles and recommendations","volume":"35","author":"Park","year":"2022","journal-title":"Korean J. Pain."},{"key":"jrpae1e05bib13","doi-asserted-by":"publisher","first-page":"557","DOI":"10.36076\/ppj.2023.26.557","type":"journal-article","article-title":"Assessment of radiation exposure with mandatory two fluoroscopic views for epidural procedures","volume":"26","author":"Manchikanti","year":"2023","journal-title":"Pain. Phys."},{"key":"jrpae1e05bib14","doi-asserted-by":"publisher","first-page":"256","DOI":"10.3344\/kjp.24087","type":"journal-article","article-title":"Current practices of cervical epidural block for cervical radicular pain: a multicenter survey conducted by the Korean Pain Society","volume":"37","author":"Kim","year":"2024","journal-title":"Korean J. Pain"},{"key":"jrpae1e05bib15","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1097\/BRS.0b013e3180b9f96e","type":"journal-article","article-title":"Increases in lumbosacral injections in the medicare population: 1994 to 2001","volume":"32","author":"Friedly","year":"2007","journal-title":"Spine"},{"article-title":"Article A56681\u2014Epidural steroid injections for pain management (coverage guidance)","author":"Centers for Medicare & Medicaid Services (CMS)","key":"jrpae1e05bib16","type":"web-resource"},{"article-title":"2023 Annual Report on National Health Insurance and Review Assessment System","year":"2023","author":"Health Insurance Review and Assessment Service (HIRA)","key":"jrpae1e05bib17","type":"web-resource"},{"key":"jrpae1e05bib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jscai.2023.100603","type":"journal-article","article-title":"Comprehensive radiation shield minimizes operator radiation exposure and obviates need for lead aprons","volume":"2","author":"Rizik","year":"2023","journal-title":"J. Soc. Cardiovasc. Angiogr. Interv."},{"key":"jrpae1e05bib19","doi-asserted-by":"publisher","first-page":"745","DOI":"10.2214\/AJR.15.15864","type":"journal-article","article-title":"Radiation risk to the fluoroscopy operator and staff","volume":"207","author":"Stahl","year":"2016","journal-title":"AJR Am. J. Roentgenol."},{"key":"jrpae1e05bib20","doi-asserted-by":"publisher","first-page":"1540","DOI":"10.21037\/atm-2020-rcs-16","type":"journal-article","article-title":"Recent developments in cataract surgery","volume":"8","author":"Grzybowski","year":"2020","journal-title":"Ann. Transl. Med."},{"year":"2019","author":"World Health Organization","key":"jrpae1e05bib21","type":"report"},{"key":"jrpae1e05bib22","doi-asserted-by":"publisher","first-page":"e1221","DOI":"10.1016\/S2214-109X(17)30393-5","type":"journal-article","article-title":"Global causes of blindness and distance vision impairment 1990\u20132020: a systematic review and meta-analysis","volume":"5","author":"Flaxman","year":"2017","journal-title":"Lancet Glob. Health"},{"article-title":"2023 Annual Statistics of Surgical Procedures","year":"2024","author":"National Health Insurance Service (NHIS)","key":"jrpae1e05bib23","type":"web-resource"},{"key":"jrpae1e05bib24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2008.08.001","type":"journal-article","article-title":"Radiological protection in medicine","volume":"37(6)","author":"International Commission on Radiological Protection","year":"2007","journal-title":"Ann. ICRP"},{"key":"jrpae1e05bib25","doi-asserted-by":"publisher","first-page":"53","DOI":"10.3344\/kjp.2020.33.1.53","type":"journal-article","article-title":"Radiation exposure to the eyes and thyroid of the pain physicians during C-arm fluoroscopy-guided cervical epidural blocks","volume":"33","author":"Choi","year":"2020","journal-title":"Korean J. Pain."},{"key":"jrpae1e05bib26","doi-asserted-by":"publisher","first-page":"86","DOI":"10.4103\/sni.sni_85_18","type":"journal-article","article-title":"Major risks and complications of cervical epidural steroid injections: an updated review","volume":"9","author":"Epstein","year":"2018","journal-title":"Surg. Neurol. Int."},{"year":"2018","author":"Ministry of Food and Drug Safety (MFDS)","key":"jrpae1e05bib27","type":"book"},{"key":"jrpae1e05bib28","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1093\/rpd\/ncaf092","type":"journal-article","article-title":"Radiation dose to the eye lens and the shielding efficacy of a protective eye mask in patients with Hodgkin lymphoma undergoing repeated CT examinations","volume":"201","author":"Rhee","year":"2025","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpae1e05bib29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2011.10.001","type":"journal-article","article-title":"ICRP Publication 116: conversion coefficients for radiological protection quantities for external radiation exposures","volume":"40(2\u20135)","author":"International Commission on Radiological Protection","year":"2010","journal-title":"Ann. ICRP"},{"year":"2020","author":"International Electrotechnical Commission","key":"jrpae1e05bib30","type":"book"},{"key":"jrpae1e05bib31","first-page":"1","type":"journal-article","article-title":"ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs\u2014threshold doses for tissue reactions in a radiation protection context","volume":"41(1\u20132)","author":"International Commission on Radiological Protection","year":"2012","journal-title":"Ann. ICRP"},{"article-title":"InLight\u00ae Model 2: Dosimetry Badges","year":"2025","author":"Landauer, Inc.","key":"jrpae1e05bib32","type":"web-resource"},{"key":"jrpae1e05bib33","doi-asserted-by":"publisher","first-page":"R351","DOI":"10.1088\/0031-9155\/53\/20\/R01","type":"journal-article","article-title":"Optically stimulated luminescence (OSL) dosimetry in medicine","volume":"53","author":"Yukihara","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"jrpae1e05bib34","first-page":"1","type":"journal-article","article-title":"Conversion coefficients for use in radiological protection against external radiation. Adopted by the ICRP and ICRU in September 1995","volume":"26(3-4)","author":"International Commission on Radiation Units and Measurements","year":"1996","journal-title":"Ann. ICRP"},{"key":"jrpae1e05bib35","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2007.10.003","type":"journal-article","article-title":"The 2007 recommendations of the international commission on radiological protection. ICRP publication 103","volume":"37(2\u20134)","author":"International Commission on Radiological Protection","year":"2007","journal-title":"Ann. ICRP"},{"key":"jrpae1e05bib36","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1093\/aje\/kwn171","type":"journal-article","article-title":"Risk of cataract after exposure to low doses of radiation: a 20-year prospective cohort study among US radiologic technologists","volume":"168","author":"Chodick","year":"2008","journal-title":"Am. J. Epidemiol."},{"key":"jrpae1e05bib37","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1667\/RR1884.1","type":"journal-article","article-title":"Epidemiological studies of cataract risk at low to moderate radiation doses: (not) seeing is believing","volume":"174","author":"Shore","year":"2010","journal-title":"Radiat. Res."},{"key":"jrpae1e05bib38","doi-asserted-by":"publisher","DOI":"10.1016\/j.envint.2020.106295","type":"journal-article","article-title":"Radiation-induced lens opacities: epidemiological, clinical and mechanistic evidence, methodological issues, research gaps and strategy","volume":"147","author":"Pasqual","year":"2021","journal-title":"Environ. Int."},{"key":"jrpae1e05bib39","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.icrp.2012.06.018","type":"journal-article","article-title":"Radiation cataract","volume":"41(3-4)","author":"Kleiman","year":"2012","journal-title":"Ann. ICRP"},{"key":"jrpae1e05bib40","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1186\/s13244-023-01452-3","type":"journal-article","article-title":"European survey on the use of patient contact shielding during radiological examinations","volume":"14","author":"Granata","year":"2023","journal-title":"Insights Imaging"},{"year":"2018","author":"National Council on Radiation Protection and Measurements (NCRP)","key":"jrpae1e05bib41","type":"report"},{"key":"jrpae1e05bib42","doi-asserted-by":"publisher","first-page":"28S","DOI":"10.1016\/j.jvs.2010.05.125","type":"journal-article","article-title":"Radiation safety in the endovascular suite: a review of occupational hazards and management","volume":"53","author":"Mitchell","year":"2011","journal-title":"J. Vasc. Surg."},{"key":"jrpae1e05bib43","doi-asserted-by":"publisher","first-page":"433","DOI":"10.2214\/AJR.14.12763","type":"journal-article","article-title":"Radiation protection for the eye in fluoroscopically guided procedures: experimental evaluation of shielding devices","volume":"215","author":"Koenig","year":"2020","journal-title":"AJR Am. J. Roentgenol."},{"key":"jrpae1e05bib44","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1007\/978-1-4757-3105-7_9","type":"journal-article","article-title":"Personnel exposure during fluoroscopy procedures","volume":"8","author":"Geise","year":"1988","journal-title":"Postgrad Radiol."},{"key":"jrpae1e05bib45","doi-asserted-by":"publisher","first-page":"145","DOI":"10.3344\/kjp.2018.31.3.145","type":"journal-article","article-title":"Three principles for radiation safety: time, distance, and shielding","volume":"31","author":"Kim","year":"2018","journal-title":"Korean J. Pain."},{"key":"jrpae1e05bib46","doi-asserted-by":"publisher","first-page":"402","DOI":"10.3174\/ajnr.A4549","type":"journal-article","article-title":"Radiation doses in patient eye lenses during interventional neuroradiology procedures","volume":"37","author":"S\u00e1nchez","year":"2016","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"jrpae1e05bib47","doi-asserted-by":"publisher","first-page":"145","DOI":"10.3344\/kjp.2014.27.2.145","type":"journal-article","article-title":"How effective are radiation-reducing gloves in C-arm fluoroscopy-guided pain interventions?","volume":"27","author":"Kim","year":"2014","journal-title":"Korean J. Pain."},{"key":"jrpae1e05bib48","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1093\/rpd\/nci369","type":"journal-article","article-title":"Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology","volume":"118","author":"Va\u00f1\u00f3","year":"2006","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpae1e05bib49","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1053\/j.tvir.2010.03.005","type":"journal-article","article-title":"Operator shielding: how and why","volume":"13","author":"Schueler","year":"2010","journal-title":"Tech. Vasc. Interv. Radiol."},{"key":"jrpae1e05bib50","doi-asserted-by":"publisher","first-page":"745","DOI":"10.2214\/AJR.16.16556","type":"journal-article","article-title":"Radiation protection for the fluoroscopy operator and staff","volume":"207","author":"Meisinger","year":"2016","journal-title":"AJR Am. J. Roentgenol."},{"key":"jrpae1e05bib51","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.urology.2017.12.011","type":"journal-article","article-title":"Radiation exposure to the urologist using an overcouch radiation source compared with an undercouch radiation source in contemporary urology practice","volume":"114","author":"Harris","year":"2018","journal-title":"Urology"}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T09:37:52Z","timestamp":1763717872000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae1e05"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,21]]},"references-count":51,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,11,21]]},"published-print":{"date-parts":[[2025,12,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ae1e05","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"type":"print","value":"0952-4746"},{"type":"electronic","value":"1361-6498"}],"subject":[],"published":{"date-parts":[[2025,11,21]]},"assertion":[{"value":"Eye lens dose and shielding efficacy of radiation-protective eyewear in C-arm\u2013guided cervical and lumbar epidural blocks: a phantom study","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2025-09-04","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-11-11","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-11-21","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}