{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T14:17:59Z","timestamp":1784816279697,"version":"3.55.0"},"reference-count":21,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2026,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Computed tomography (CT) contributes disproportionately to medical radiation exposure. While most patients undergo only a few examinations, a subset accumulates high cumulative effective doses (CEDs), raising concern for long-term stochastic risks. Recently, the concept of a recurrent exposure reference level (RERL) has been proposed as a benchmark for cumulative dose monitoring in recurrently imaged patients. To evaluate cumulative radiation exposure from recurrent CT imaging in a tertiary care hospital, determine the proportion of patients exceeding high-dose thresholds, and establish a local RERL. All adult CT examinations performed at Vilnius University Hospital Santaros Klinikos between 2022 and 2024 were retrospectively analysed. Recurrent patients were defined as those with at least one CT in 2023 and an additional CT in 2022, 2023, or 2024. Outcome measures included the annual and three-year incidence and prevalence of CED \u2a7e 100 mSv, dose distributions, and RERL determination as the 75th percentile of annual CED among recurrent patients. Over three years, 78 258 patients underwent 99 865 CT examinations. The annual number of patients and exams increased steadily, but the yearly incidence of high-dose patients (CED \u2a7e 100 mSv) remained stable at \u223c2%. Across the full cohort, 1633 patients (3.6%) exceeded 100 mSv, and 29 patients (0.04%) surpassed 500 mSv. Among 9199 recurrent patients (35.6% of the total), 18.2% exceeded 100 mSv within three years. Most patients (68%) crossed this threshold with fewer than five CTs. The local RERL, defined as the 75th percentile of annual CED in recurrent patients, was 36 mSv. A subset of patients in a tertiary care setting accumulated high radiation doses from recurrent CT, often with relatively few examinations. The derived RERL aligns closely with values reported in other European studies, supporting its use as a practical benchmark for monitoring cumulative dose. Systematic dose tracking, integration of RERLs, and strict adherence to justification and optimisation are essential to mitigate risks while preserving the diagnostic value of CT.<\/jats:p>","DOI":"10.1088\/1361-6498\/ae4521","type":"journal-article","created":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T22:48:08Z","timestamp":1770936488000},"page":"011513","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Recurrent CT imaging and strategies for patient radiation protection"],"prefix":"10.1088","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9774-9461","authenticated-orcid":true,"given":"Antonio","family":"Jreije","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonid","family":"Krynke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Birut\u0117","family":"Gricien\u0117","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,2,23]]},"reference":[{"key":"jrpae4521bib1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222432","type":"journal-article","article-title":"Clinical applications of photon-counting CT: a review of pioneer studies and a glimpse into the future","volume":"309","author":"Douek","year":"2023","journal-title":"Radiology"},{"key":"jrpae4521bib2","doi-asserted-by":"publisher","first-page":"135","DOI":"10.3238\/arztebl.m2022.0395","type":"journal-article","article-title":"Radiation exposure in computed tomography","volume":"120","author":"Bos","year":"2023","journal-title":"Dtsch. Arztebl Int."},{"key":"jrpae4521bib3","doi-asserted-by":"publisher","first-page":"5514","DOI":"10.1007\/s00330-021-07696-1","type":"journal-article","article-title":"Cumulative effective dose from recurrent CT examinations in Europe: proposal for clinical guidance based on an ESR EuroSafe imaging survey","volume":"31","author":"European Society of Radiology (ESR)","year":"2021","journal-title":"Eur. Radiol."},{"key":"jrpae4521bib4","doi-asserted-by":"publisher","first-page":"3065","DOI":"10.1007\/s00330-020-07458-5","type":"journal-article","article-title":"Analysis of patients receiving \u2a7e 100 mSv during a computed tomography intervention","volume":"31","author":"Arellano","year":"2021","journal-title":"Eur. Radiol."},{"key":"jrpae4521bib5","doi-asserted-by":"publisher","first-page":"1828","DOI":"10.1007\/s00330-019-06523-y","type":"journal-article","article-title":"Patients undergoing recurrent CT scans: assessing the magnitude","volume":"30","author":"Rehani","year":"2020","journal-title":"Eur. Radiol."},{"key":"jrpae4521bib6","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1148\/radiol.2511081296","type":"journal-article","article-title":"Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults","volume":"251","author":"Sodickson","year":"2009","journal-title":"Radiology"},{"key":"jrpae4521bib7","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/ac31c1","type":"journal-article","article-title":"How much should we be concerned about cumulative effective doses in medical imaging?","volume":"42","author":"Martin","year":"2022","journal-title":"J. Radiol. Prot."},{"key":"jrpae4521bib8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","type":"journal-article","article-title":"ICRP publication 135: diagnostic reference levels in medical imaging","volume":"46 (1)","author":"Va\u00f1\u00f3","year":"2017","journal-title":"Ann. ICRP"},{"key":"jrpae4521bib9","doi-asserted-by":"publisher","first-page":"1658","DOI":"10.1007\/s00330-024-11240-2","type":"journal-article","article-title":"Establishment of recurrent exposures reference levels for repeated computed tomography examinations in adult patients on a nationwide level in Slovakia","volume":"35","author":"Brambilla","year":"2025","journal-title":"Eur. Radiol."},{"key":"jrpae4521bib10","doi-asserted-by":"publisher","first-page":"4475","DOI":"10.1007\/s00330-023-10520-7","type":"journal-article","article-title":"Optimisation of protection in the medical exposure of recurrent adult patients due to computed tomography procedures: development of recurrent exposures reference levels","volume":"34","author":"Bramilla","year":"2024","journal-title":"Eur. Radiol."},{"key":"jrpae4521bib11","article-title":"European guidance on estimating population doses from medical x-ray procedures","author":"European Commission","year":"2008","type":"report"},{"key":"jrpae4521bib12","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.ejmp.2020.07.014","type":"journal-article","article-title":"Estimates of the number of patients with high cumulative doses through recurrent CT exams in 35 OECD countries","volume":"76","author":"Rehani","year":"2020","journal-title":"Phys. Med."},{"key":"jrpae4521bib13","doi-asserted-by":"publisher","first-page":"2493","DOI":"10.1007\/s00330-019-06528-7","type":"journal-article","article-title":"Multinational data on cumulative radiation exposure of patients from recurrent radiological procedures: call for action","volume":"30","author":"Brambilla","year":"2020","journal-title":"Eur. Radiol."},{"key":"jrpae4521bib14","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20200814","type":"journal-article","article-title":"Challenges for managing the cumulative effective dose for patients","volume":"93","author":"Vano","year":"2020","journal-title":"Br. J. Radiol."},{"key":"jrpae4521bib15","doi-asserted-by":"publisher","DOI":"10.26044\/esi2020\/ESI-11078","type":"report","article-title":"Dose management\u2013requirements and recommendations for users","author":"Loose","year":"2020"},{"key":"jrpae4521bib16","article-title":"On target 2: Updated guidance for image-guided radiotherapy","author":"Royal College of Radiologists, Society and College of Radiographers, Institute of Physics and Engineering in Medicine","year":"2021","type":"report"},{"key":"jrpae4521bib17","doi-asserted-by":"publisher","first-page":"e84","DOI":"10.1002\/mp.12824","type":"journal-article","article-title":"Image guidance doses delivered during radiotherapy: quantification, management, and reduction: report of the AAPM Therapy Physics Committee Task Group 180","volume":"45","author":"Ding","year":"2018","journal-title":"Med. Phys."},{"key":"jrpae4521bib18","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.2106\/JBJS.18.01334","type":"journal-article","article-title":"An estimation of lifetime fatal carcinogenesis risk attributable to radiation exposure in the first year following polytrauma: a major trauma center\u2019s experience over 10 years","volume":"101","author":"Howard","year":"2019","journal-title":"J. Bone Joint Surg."},{"key":"jrpae4521bib19","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20210477","type":"journal-article","article-title":"Radiation protection perspective to recurrent medical imaging: what is known and what more is needed?","volume":"94","author":"Vassileva","year":"2021","journal-title":"Br. J. Radiol."},{"key":"jrpae4521bib20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2007.10.003","type":"journal-article","article-title":"The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103","volume":"37 (2\u20134)","author":"ICRP","year":"2007","journal-title":"Ann. ICRP"},{"key":"jrpae4521bib21","article-title":"European co-ordinated action on improving justification of computed tomography: results and recommendations from a first-time multi-national study on CT justification in the EU","author":"Brklja\u010di\u0107","year":"2024","type":"other"}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T07:59:42Z","timestamp":1771833582000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae4521"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,23]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2,23]]},"published-print":{"date-parts":[[2026,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ae4521","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,23]]},"assertion":[{"value":"Recurrent CT imaging and strategies for patient radiation protection","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of the Society for Radiological Protection by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-10-02","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-02-12","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-02-23","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}