{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T22:35:07Z","timestamp":1785796507370,"version":"3.56.0"},"reference-count":29,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T00:00:00Z","timestamp":1776038400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T00:00:00Z","timestamp":1776038400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"},{"start":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T00:00:00Z","timestamp":1776038400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T00:00:00Z","timestamp":1776038400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2026,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study investigates the impact of rotation axis configuration and modulation of tube voltage (kV) and dose rate on organ dose estimates in dental panoramic radiography, using Monte Carlo simulations. Computational phantoms representing 15 year-old male and female patients were each exposed to 16 protocol scenarios across three panoramic radiography units, varying the rotation centre (sliding versus fixed) and the presence or absence of x-ray beam modulation. Simulations were conducted using the particle and heavy-ion transport code system code, employing dump files and a multi-source approach to replicate realistic exposure conditions. Results were expressed and analysed as percentage differences relative to reference protocols incorporating a sliding rotation centre and beam modulation. The findings revealed a consistent and substantial underestimation\u2014up to 50%\u2014of doses to the thyroid, salivary glands, and brain when fixed-axis or non-modulated protocols were applied. The oral mucosa (lips and chin) exhibited marked overestimation (up to 700%), particularly in males, attributable to mandibular anatomy and beam geometry. Sex-related differences were evident in doses to the tongue and floor of the mouth, linked to anatomical mass variations, with male tongue mass approximately 8% greater than female. All results displayed relative errors below 5%. These findings highlight that simplified simulation models lacking a sliding rotation axis and beam modulation significantly distort and compromise dose assessments. Consequently, realistic modelling of beam dynamics is essential for accurate dosimetry in panoramic radiography.<\/jats:p>","DOI":"10.1088\/1361-6498\/ae597a","type":"journal-article","created":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T22:49:31Z","timestamp":1774997371000},"page":"021505","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Effect of rotation axis and modulation on x-ray emission in dose assessment in panoramic radiographs using the Monte Carlo method"],"prefix":"10.1088","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8464-5783","authenticated-orcid":true,"given":"Wilson Otto","family":"Batista","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4614-8209","authenticated-orcid":true,"given":"Maria Rosangela","family":"Soares","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1587-1445","authenticated-orcid":false,"given":"Jacqueline Machado Gurj\u00e3o","family":"Rios","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,4,13]]},"reference":[{"key":"jrpae597abib1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/eos.12796","type":"journal-article","article-title":"Choice of radiography in orthodontic treatment on children and adolescents: a questionnaire-based study performed in Sweden","volume":"129","author":"Stervik","year":"2021","journal-title":"Eur. J. Oral Sci."},{"key":"jrpae597abib2","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1007\/s40368-019-00493-x","type":"journal-article","article-title":"Best clinical practice guidance for prescribing dental radiographs in children and adolescents: an EAPD policy document","volume":"21","author":"K\u00fchnisch","year":"2020","journal-title":"Eur. Arch. Paediatr. Dent."},{"key":"jrpae597abib3","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s40368-019-00478-w","type":"journal-article","article-title":"A systematic review of relative indications and contra-indications for prescribing panoramic radiographs in dental paediatric patients","volume":"21","author":"Tsiklakis","year":"2020","journal-title":"Eur. Arch. Paediatr. Dent."},{"key":"jrpae597abib4","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20151052","type":"journal-article","article-title":"Absorbed organ and effective doses from digital intra-oral and panoramic radiography applying the ICRP 103 recommendations for effective dose estimations","volume":"89","author":"Granlund","year":"2016","journal-title":"Br. J. Radiol."},{"key":"jrpae597abib5","type":"conference-proceedings","article-title":"Radiation dose and risk in dental panoramic radiography: a literature review","volume":"vol 319","author":"Elmorabit","year":"2021"},{"key":"jrpae597abib6","author":"White","year":"2014","type":"book"},{"key":"jrpae597abib7","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/j.oooo.2015.10.030","type":"journal-article","article-title":"Comparison of dosimetry methods for panoramic radiography: thermoluminescent dosimeter measurement versus personal computer-based Monte Carlo method calculation","volume":"121","author":"Lee","year":"2016","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol."},{"key":"jrpae597abib8","doi-asserted-by":"publisher","first-page":"9691","DOI":"10.1038\/s41598-019-46157-0","type":"journal-article","article-title":"Efficacy of the Monte Carlo method and dose reduction strategies in paediatric panoramic radiography","volume":"9","author":"Lee","year":"2019","journal-title":"Sci. Rep."},{"key":"jrpae597abib9","doi-asserted-by":"publisher","first-page":"21","DOI":"10.5624\/isd.2018.48.1.21","type":"journal-article","article-title":"Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software","volume":"48","author":"Kim","year":"2018","journal-title":"Imaging Sci. Dent."},{"key":"jrpae597abib10","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1016\/j.nima.2010.09.101","type":"journal-article","article-title":"Development of a digital panoramic x-ray imaging system of adaptive image layers for dental applications","volume":"652","author":"Choi","year":"2011","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"jrpae597abib11","doi-asserted-by":"publisher","first-page":"141032","DOI":"10.1109\/ACCESS.2024.3422650","type":"journal-article","article-title":"Recent advances in dental panoramic x-ray synthesis and its clinical applications","volume":"12","author":"Sunilkumar","year":"2024","journal-title":"IEEE Access"},{"key":"jrpae597abib12","author":"J. Morita Mfg. Corp","year":"2025","type":"report"},{"key":"jrpae597abib13","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1093\/dmfr\/twae050","type":"journal-article","article-title":"A novel method for measuring the direction and angle of central ray and predicting rotation centre via panorama phantom","volume":"53","author":"Joh","year":"2024","journal-title":"Dentomaxillofac. Radiol."},{"key":"jrpae597abib14","article-title":"Radiation measurement digitizers","author":"Radcal","year":"2025","type":"web-resource"},{"key":"jrpae597abib15","author":"Canon Medical Systems Corporation","year":"2018","type":"book"},{"key":"jrpae597abib16","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1016\/j.nima.2006.02.125","type":"journal-article","article-title":"Interactive three-dimensional visualization and creation of geometries for Monte Carlo calculations","volume":"562","author":"Theis","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"jrpae597abib17","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1080\/00223131.2023.2275736","type":"journal-article","article-title":"Recent improvements of the particle and heavy ion transport code system\u2013PHITS version 3.33","volume":"61","author":"Sato","year":"2024","journal-title":"J. Nucl. Sci. Technol."},{"key":"jrpae597abib18","article-title":"SpekPy ver. 2 0.8","author":"Vorbau","year":"2022","type":"web-resource"},{"key":"jrpae597abib19","doi-asserted-by":"publisher","first-page":"S160","DOI":"10.1088\/1361-6498\/ac0801","type":"journal-article","article-title":"Development of paediatric mesh-type reference computational phantom series of International Commission on Radiological Protection","volume":"41","author":"Choi","year":"2021","journal-title":"J. Radiol. Prot."},{"key":"jrpae597abib20","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1177\/01466453231210649","type":"journal-article","article-title":"Paediatric mesh-type reference computational phantoms. ICRP Publication 156","volume":"53 (1\u20132)","author":"ICRP","year":"2024","journal-title":"Ann. ICRP"},{"key":"jrpae597abib21","article-title":"LabFit","author":"Pereira da Silva","year":"2025","type":"web-resource"},{"key":"jrpae597abib22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2021\/6924314","type":"journal-article","article-title":"A review of doses for dental imaging in 2010\u20132020 and development of a web dose calculator","volume":"2021","author":"Lee","year":"2021","journal-title":"Radiol. Res. Pract."},{"key":"jrpae597abib23","article-title":"PHITS","author":"JAEA","year":"2024","type":"web-resource"},{"key":"jrpae597abib24","author":"Salvat","year":"2019","type":"book"},{"key":"jrpae597abib25","author":"IAEA","year":"2024","type":"book"},{"key":"jrpae597abib26","doi-asserted-by":"publisher","first-page":"4069","DOI":"10.1088\/0031-9155\/54\/13\/008","type":"journal-article","article-title":"Dose conversion coefficients for electron exposure of the human eye lens","volume":"54","author":"Behrens","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"jrpae597abib27","article-title":"Acceptance testing and quality control of dental imaging equipment: report of AAPM task group 175","author":"American Association of Physicists in Medicine (AAPM)","year":"2019","type":"report"},{"key":"jrpae597abib28","doi-asserted-by":"publisher","first-page":"267","DOI":"10.2485\/jhtb.23.267","type":"journal-article","article-title":"Sex-related differences in cortical and trabecular bone quantities at the mandibular molar","volume":"23","author":"Matsuura","year":"2014","journal-title":"J. Hard Tissue Biol."},{"key":"jrpae597abib29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1590\/1981-86372019000073579","type":"journal-article","article-title":"Sexual dimorphism of mandibular measures from computed tomographies RGO","volume":"67","author":"Ishigame","year":"2019","journal-title":"Rev. Ga\u00fach. Odontol."}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T13:34:19Z","timestamp":1776087259000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae597a"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,13]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,4,13]]},"published-print":{"date-parts":[[2026,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ae597a","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,13]]},"assertion":[{"value":"Effect of rotation axis and modulation on x-ray emission in dose assessment in panoramic radiographs using the Monte Carlo method","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2025-12-01","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-03-31","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-04-13","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}