{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T09:59:56Z","timestamp":1777283996052,"version":"3.51.4"},"reference-count":22,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T00:00:00Z","timestamp":1777248000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T00:00:00Z","timestamp":1777248000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2026,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Occupational use of ionising radiation in medical procedures requires stringent protective measures to reduce exposure risks for staff. This study examined the integrity and reliability of personal protective equipment (PPE) used in a hospital setting, focusing on methods for detecting damage and its impact on radiation transmission. A total of 64 lead-based protective coats (one and two pieces) were examined for damage using four inspection techniques: visual- palpatory examination, LED light source, computed tomography (CT), and fluoroscopy\/conventional x-ray. In the second part of the study, the transmittance of the primary beam and scattered radiation through damaged and undamaged areas was measured. Damage was found in 25% of protective coats, with 15.6%\u201318.8% classified as unsuitable according to recommended rejection models. Inspection using fluoroscopy and conventional x-ray was the most accurate method for detecting damage, followed by CT. Visual-palpatory, and light source assessments were less reliable, detecting 73.6% and 47.4% of all defects, respectively. Transmission of the primary beam in damaged areas increased from 0.5% to 316.6% compared to undamaged areas. Defective areas led to increased radiation exposure, potentially resulting in higher occupational doses and health concerns. The study emphasises the need for routine PPE inspections and recommends incorporating comprehensive assessments, including radiographic evaluations, into annual quality assurance and quality control protocols, as these have been shown to be most effective, particularly assessments using conventional x-ray units and fluoroscopy. These measures can significantly reduce the risk of unnecessary radiation exposure. However, time efficiency, required resources, and potential risks should also be considered and further evaluated.<\/jats:p>","DOI":"10.1088\/1361-6498\/ae6081","type":"journal-article","created":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T22:48:12Z","timestamp":1776379692000},"page":"021509","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of radiation integrity and transmission in lead-rubber layers: a comparative analysis of visual-palpatory, light source and radiographic inspection methods"],"prefix":"10.1088","volume":"46","author":[{"given":"Manca","family":"Likar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Nini\u0107","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Jur\u0161a","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9438-7415","authenticated-orcid":true,"given":"Nejc","family":"Meki\u0161","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2026,4,27]]},"reference":[{"key":"jrpae6081bib1","doi-asserted-by":"publisher","first-page":"264","DOI":"10.5662\/wjm.v12.i4.264","type":"journal-article","article-title":"Are we aware of radiation: a study about necessity of diagnostic x-ray exposure","volume":"12","author":"Karavas","year":"2022","journal-title":"World J. Methodol."},{"key":"jrpae6081bib2","doi-asserted-by":"publisher","first-page":"5675","DOI":"10.1007\/s00330-023-09541-z","type":"journal-article","article-title":"Occupational exposure to ionizing radiation in medical staff: trends during the 2009\u20132019 period in a multicentric study","volume":"33","author":"Baudin","year":"2023","journal-title":"Eur. Radiol."},{"key":"jrpae6081bib3","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/1436\/1\/012050","type":"journal-article","article-title":"Occupational dose during an interventional radiology procedure","volume":"1436","author":"Kartikasari","year":"2020","journal-title":"J. Phys.: Conf. Ser."},{"key":"jrpae6081bib4","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.ejrad.2010.06.034","type":"journal-article","article-title":"Radiation protection of medical staff","volume":"76","author":"Le Heron","year":"2010","journal-title":"Eur. J. Radiol."},{"key":"jrpae6081bib5","doi-asserted-by":"publisher","first-page":"1520","DOI":"10.4103\/jfmpc.jfmpc_2292_20","type":"journal-article","article-title":"Radiation in medical practice & health effects of radiation: rationale, risks, and rewards","volume":"10","author":"Jain","year":"2021","journal-title":"J. Fam. Med. Prim. Care"},{"key":"jrpae6081bib6","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s13244-022-01323-3","type":"journal-article","article-title":"Integrity of personal radiation protective equipment (PRPE): a 4-year longitudinal follow-up study","volume":"13","author":"Kellens","year":"2022","journal-title":"Insights into Imaging"},{"key":"jrpae6081bib7","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.1016\/j.jacr.2016.05.006","type":"journal-article","article-title":"Personnel protective apparel integrity inspection: where we are and what we need","volume":"13","author":"Smith","year":"2016","journal-title":"J. Am. Coll. Radiol."},{"key":"jrpae6081bib8","doi-asserted-by":"publisher","first-page":"244","DOI":"10.3344\/kjp.2018.31.4.244","type":"journal-article","article-title":"Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management","volume":"31","author":"Cheon","year":"2018","journal-title":"Korean J. Pain"},{"key":"jrpae6081bib9","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1053\/j.tvir.2017.12.002","type":"journal-article","article-title":"Should we keep the lead in the aprons?","volume":"21","author":"Bartal","year":"2018","journal-title":"Tech. Vasc. Interv. Radiol."},{"key":"jrpae6081bib10","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1007\/s00270-019-02391-7","type":"journal-article","article-title":"Don\u2019t be caught half-dressed when working with radiation","volume":"43","author":"Yu","year":"2020","journal-title":"Cardiovasc. Intervent. Radiol."},{"key":"jrpae6081bib11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317750356","type":"journal-article","article-title":"ICRP publication 139: occupational radiological protection in interventional procedures","volume":"47(2)","author":"L\u00f3pez","year":"2018","journal-title":"Ann. ICRP"},{"key":"jrpae6081bib12","doi-asserted-by":"publisher","first-page":"34","DOI":"10.3329\/bsmmuj.v11i1.35360","type":"journal-article","article-title":"Integrity test of lead apron and its effect on personnel and carer","volume":"11","author":"Omojola","year":"2018","journal-title":"Bangabandhu Sheikh Mujib Med. Univ. J."},{"key":"jrpae6081bib13","first-page":"1","type":"other","article-title":"Radiation effects on polymer materials commonly used in medical devices","author":"IAEA","year":"2021"},{"key":"jrpae6081bib14","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1007\/s00540-016-2140-2","type":"journal-article","article-title":"Evaluation of lead aprons and their maintenance and management at our hospital","volume":"30","author":"Matsuda","year":"2016","journal-title":"J. Anesth."},{"key":"jrpae6081bib15","article-title":"Radiation protection accessories for medical use of X-radiation\u2014part 2: quality control of protective clothes being in use (DIN 6857\u20132)","author":"DIN Deutsches Institut f\u00fcr Normung","year":"2021","type":"other"},{"key":"jrpae6081bib16","doi-asserted-by":"publisher","first-page":"S67","DOI":"10.1097\/00004032-200105001-00008","type":"journal-article","article-title":"Inspection of lead aprons: criteria for rejection","volume":"80","author":"Lambert","year":"2001","journal-title":"Health Phys."},{"key":"jrpae6081bib17","doi-asserted-by":"publisher","first-page":"S133","DOI":"10.1097\/01.HP.0000314763.19226.86","type":"journal-article","article-title":"Inspection of lead aprons: a practical rejection model","volume":"95","author":"Stam","year":"2008","journal-title":"Health Phys."},{"key":"jrpae6081bib18","article-title":"Radiation standard 4","author":"NSW Environment Protection Authority","year":"2023","type":"other"},{"key":"jrpae6081bib19","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1093\/rpd\/ncn244","type":"journal-article","article-title":"Technical note usefulness of non-lead aprons in radiation protection for physicians performing","volume":"131","author":"Zuguchi","year":"2008","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpae6081bib20","first-page":"52","type":"journal-article","article-title":"How efficient are the lead aprons used for radiation protection in our hospitals?","volume":"8","author":"Chiegwu","year":"2018","journal-title":"Indian J. Appl. Res."},{"key":"jrpae6081bib21","doi-asserted-by":"publisher","first-page":"147","DOI":"10.4261\/1305-3825.DIR.4526-11.1","type":"journal-article","article-title":"How protective are the lead aprons we use against ionizing radiation?","volume":"18","author":"Oyar","year":"2012","journal-title":"Diagn. Interv. Radiol."},{"key":"jrpae6081bib22","first-page":"337","author":"Chang","year":"2021","type":"book"}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T09:29:01Z","timestamp":1777282141000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae6081"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,27]]},"references-count":22,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,4,27]]},"published-print":{"date-parts":[[2026,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ae6081","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,27]]},"assertion":[{"value":"Evaluation of radiation integrity and transmission in lead-rubber layers: a comparative analysis of visual-palpatory, light source and radiographic inspection methods","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of the Society for Radiological Protection by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-01-27","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-04-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-04-27","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}