{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T07:02:26Z","timestamp":1780556546582,"version":"3.54.1"},"reference-count":53,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T00:00:00Z","timestamp":1780531200000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T00:00:00Z","timestamp":1780531200000},"content-version":"tdm","delay-in-days":3,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2026,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Interventional cardiology procedures chronically expose healthcare personnel to ionising radiation, raising concerns about long-term health effects such as cataracts and cancer. Consequently, growing attention has been directed towards advanced shielding technologies capable of substantially reducing occupational dose while improving ergonomic conditions.\u201d\n                    <jats:italic>Objective.<\/jats:italic>\n                    To synthesise the available evidence on the technical performance and radiation attenuation capabilities of autonomous radiation protection systems (ARPS) (Protego\u2122, Rampart\u2122, and EggNest XR\u2122), used in interventional cardiology settings. A scoping review was conducted following the PRISMA-ScR framework. Relevant studies were identified through a systematic search of PubMed, EBSCO, Scopus, WOS and Cochrane. Eligible studies included clinical and phantom-based assessments reporting quantitative dosimetric outcomes. Fourteen studies met the inclusion criteria. Protego\u2122 was associated with consistently high reported attenuation, typically \u2a7e95% in studies providing quantifiable measurements; in several investigations, post-shielding doses fell below the detection limits of standard personal dosimeters, whereas Rampart\u2122 demonstrated wider reported attenuation ranges (approximately 16.7%\u2013100%) across heterogeneous study designs and measurement protocols and EggNest XR\u2122 exhibited attenuation values ranging from 91.5% to 99.0% in a single phantom-based study. Device performance varied by anatomical site and professional role, with higher attenuation typically observed among primary operators (often exceeding 95% at head and torso levels) compared with more variable reductions in peripheral personnel such as nurses and anaesthesiologists, where attenuation occasionally decreased to the 80%\u201390% range depending on positioning and projection. The attenuation results for autonomous shielding systems are promising, particularly for fixed systems, which demonstrate consistently high performance. Given their potential for ergonomic improvement and radiation reduction, ARPS are emerging as valuable tools. However, given the limited clinical validation and the heterogeneity of existing study, the implementation of these systems should be supported by site-specific validation and standardised dosimetry protocols\u201d.\n                  <\/jats:p>","DOI":"10.1088\/1361-6498\/ae7122","type":"journal-article","created":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T22:49:12Z","timestamp":1779403752000},"page":"021003","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Occupational dose attenuation and dosimetric performance of autonomous radiation protection systems in fluoroscopy: a scoping review with implications for the role of conventional lead aprons"],"prefix":"10.1088","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8221-9035","authenticated-orcid":true,"given":"Sergio","family":"Ramos-Avasola","sequence":"first","affiliation":[{"name":"Escuela de Tecnolog\u00eda M\u00e9dica, Facultad de Ciencias, Universidad San Sebasti\u00e1n"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nitza","family":"Espinosa-Rojo","sequence":"additional","affiliation":[{"name":"Unidad de Hemodinamia, Hospital Regional Dr Juan No\u00e9 Crevani"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ricardo","family":"Ampuero","sequence":"additional","affiliation":[{"name":"Escuela de Tecnolog\u00eda M\u00e9dica, Facultad de Ciencias, Universidad San Sebasti\u00e1n"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Constanza","family":"Vira","sequence":"additional","affiliation":[{"name":"Escuela de Tecnolog\u00eda M\u00e9dica, Facultad de Ciencias, Universidad San Sebasti\u00e1n"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Araya","sequence":"additional","affiliation":[{"name":"Servicio de Cardiolog\u00eda Intervencionista, Cl\u00ednica Alemana"},{"name":"Sociedad Latinoamericana de Cardiolog\u00eda Intervencionista (SOLACI)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1020-8775","authenticated-orcid":true,"given":"Adlin","family":"L\u00f3pez","sequence":"additional","affiliation":[{"name":"Centro de Excelencia en F\u00edsica e Ingenier\u00eda en Salud. Universidad de La Frontera"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2501-579X","authenticated-orcid":true,"given":"Edilaine","family":"Honorio da Silva","sequence":"additional","affiliation":[{"name":"Universidade de S\u00e3o Paulo, Institute of Physics"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,6,4]]},"reference":[{"key":"jrpae7122bib1","doi-asserted-by":"publisher","first-page":"ehab724","DOI":"10.1093\/eurheartj\/ehab724.3032","type":"journal-article","article-title":"Cath lab nursing\u2014it\u2019s a risky business","volume":"42","author":"Wilson-Stewart","year":"2021","journal-title":"Eur. Heart J."},{"key":"jrpae7122bib2","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1088\/0952-4746\/21\/1\/609","type":"journal-article","article-title":"UNSCEAR report 2000: sources and effects of ionizing radiation","volume":"21","author":"Charles","year":"2001","journal-title":"J. Radiol. Prot."},{"key":"jrpae7122bib3","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.jvir.2012.10.016","type":"journal-article","article-title":"Radiation-associated lens opacities in catheterization personnel: results of a survey and direct assessments","volume":"24","author":"Vano","year":"2013","journal-title":"J. Vasc. Interv Radiol."},{"key":"jrpae7122bib4","doi-asserted-by":"publisher","first-page":"224","DOI":"10.37349\/ec.2024.00036","type":"journal-article","article-title":"The head of invasive cardiologists as a target of professional exposure to ionizing radiation","volume":"2","author":"Borghini","year":"2024","journal-title":"Explor. Cardiol."},{"key":"jrpae7122bib5","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1096\/fj.04-3287fje","type":"journal-article","article-title":"Somatic DNA damage in interventional cardiologists: a case\u2010control study","volume":"19","author":"Andreassi","year":"2005","journal-title":"FASEB J."},{"key":"jrpae7122bib6","doi-asserted-by":"publisher","first-page":"1368","DOI":"10.1016\/j.amjcard.2012.12.060","type":"journal-article","article-title":"Brain and neck tumors among physicians performing interventional procedures","volume":"111","author":"Roguin","year":"2013","journal-title":"Am. J. Cardiol."},{"key":"jrpae7122bib7","first-page":"1850","type":"journal-article","article-title":"Brain tumours among interventional cardiologists: a call for alarm?","volume":"33","author":"Roguin","year":"2012","journal-title":"Eur. Heart J."},{"key":"jrpae7122bib8","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.4244\/EIJV7I9A172","type":"journal-article","article-title":"Brain tumours among interventional cardiologists: a cause for alarm? Report of four new cases from two cities and a review of the literature","volume":"7","author":"Roguin","year":"2012","journal-title":"EuroIntervention"},{"key":"jrpae7122bib9","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.ejrad.2009.03.035","type":"journal-article","article-title":"Radiation effects analysis in a group of interventional radiologists using biological and physical dosimetry methods","volume":"75","author":"Ramos","year":"2010","journal-title":"Eur. J. Radiol."},{"key":"jrpae7122bib10","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1111\/j.1540-8183.2010.00610.x","type":"journal-article","article-title":"Cutaneous cancers in an interventional cardiologist: a cautionary tale","volume":"24","author":"EAGAN Jr","year":"2011","journal-title":"J. Interventional Cardiol."},{"key":"jrpae7122bib11","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1002\/ccd.27258","type":"journal-article","article-title":"Interventional cardiologists: beware and be aware: an updated report of radiation-induced cutaneous cancers","volume":"91","author":"Eagan","year":"2018","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"jrpae7122bib12","doi-asserted-by":"publisher","first-page":"1960","DOI":"10.1016\/j.jvir.2020.07.004","type":"journal-article","article-title":"Estimating occupational radiation exposure using cytogenetic dosimetry in an interventional radiologist with skin cancer: a case report","volume":"31","author":"Jang","year":"2020","journal-title":"J. Vasc. Interventional Radiol."},{"key":"jrpae7122bib13","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/j.carrev.2021.01.029","type":"journal-article","article-title":"Multiple cutaneous cancers in an interventional cardiologist: predominance in unprotected skin nearest the radiation source","volume":"28","author":"Purohit","year":"2021","journal-title":"Cardiovasc. Revasc. Med."},{"key":"jrpae7122bib14","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1007\/s00540-016-2140-2","type":"journal-article","article-title":"Evaluation of lead aprons and their maintenance and management at our hospital","volume":"30","author":"Matsuda","year":"2016","journal-title":"J. Anesth."},{"key":"jrpae7122bib15","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.jvs.2020.04.523","type":"journal-article","article-title":"Intraprocedural ergonomics of vascular surgeons","volume":"73","author":"Davila","year":"2021","journal-title":"J. Vasc. Surg."},{"key":"jrpae7122bib16","doi-asserted-by":"publisher","DOI":"10.1016\/j.apergo.2019.103029","type":"journal-article","article-title":"Effect of surgical radiation personal protective equipment on EMG-based measures of back and shoulder muscle fatigue: a laboratory study of novices","volume":"84","author":"Tetteh","year":"2020","journal-title":"Appl. Ergon."},{"key":"jrpae7122bib17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317750356","type":"journal-article","article-title":"ICRP publication 139: occupational radiological protection in interventional procedures","volume":"47","author":"Ortiz Lopez","year":"2018","journal-title":"Ann. ICRP"},{"key":"jrpae7122bib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jscai.2023.101109","type":"journal-article","article-title":"Radiation doses to the entire catheterization laboratory team with a novel radiation protection device","volume":"3","author":"Parikh","year":"2024","journal-title":"J. Soc. Cardiovasc. Angiogr. Interventional"},{"key":"jrpae7122bib19","doi-asserted-by":"publisher","first-page":"467","DOI":"10.7326\/M18-0850","type":"journal-article","article-title":"PRISMA extension for scoping reviews (PRISMA-ScR): checklist and explanation","volume":"169","author":"Tricco","year":"2018","journal-title":"Ann. Interventional Med."},{"key":"jrpae7122bib20","doi-asserted-by":"publisher","first-page":"2119","DOI":"10.11124\/JBIES-20-00167","type":"journal-article","article-title":"Updated methodological guidance for the conduct of scoping reviews","volume":"18","author":"Peters","year":"2020","journal-title":"JBI Evidence Synth."},{"key":"jrpae7122bib21","author":"Higgins","year":"2022","type":"book"},{"key":"jrpae7122bib22","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1186\/s13643-016-0384-4","type":"journal-article","article-title":"Rayyan\u2014a web and mobile app for systematic reviews","volume":"5","author":"Ouzzani","year":"2016","journal-title":"Syst. Rev."},{"key":"jrpae7122bib23","doi-asserted-by":"publisher","first-page":"e1230","DOI":"10.1002\/cl2.1230","type":"journal-article","article-title":"PRISMA2020 : an R package and shiny app for producing PRISMA 2020\u2010compliant flow diagrams, with interactivity for optimised digital transparency and open synthesis","volume":"18","author":"Haddaway","year":"2022","journal-title":"Campbell Syst. Rev."},{"key":"jrpae7122bib24","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2023.102543","type":"journal-article","article-title":"Effectiveness of staff radiation protection devices for interventional cardiology procedures","volume":"107","author":"Huet","year":"2023","journal-title":"Phys. Med."},{"key":"jrpae7122bib25","doi-asserted-by":"publisher","first-page":"378","DOI":"10.11124\/JBIES-23-00268","type":"journal-article","article-title":"The revised JBI critical appraisal tool for the assessment of risk of bias for quasi-experimental studies","volume":"22","author":"Barker","year":"2024","journal-title":"JBI Evidence Synth."},{"key":"jrpae7122bib26","doi-asserted-by":"publisher","first-page":"494","DOI":"10.11124\/JBIES-22-00430","type":"journal-article","article-title":"The revised JBI critical appraisal tool for the assessment of risk of bias for randomized controlled trials","volume":"21","author":"Barker","year":"2023","journal-title":"JBI Evidence Synth."},{"key":"jrpae7122bib27","doi-asserted-by":"publisher","DOI":"10.46658\/JBIMES-24-06","type":"book","article-title":"Systematic reviews of etiology and risk","author":"Moola","year":"2020","edition":"ed"},{"key":"jrpae7122bib28","doi-asserted-by":"publisher","DOI":"10.1016\/j.jscai.2023.100603","type":"journal-article","article-title":"Comprehensive radiation shield minimizes operator radiation exposure and obviates need for lead aprons","volume":"2","author":"Rizik","year":"2023","journal-title":"J. Soc. Cardiovasc. Angiogr. Interventional"},{"key":"jrpae7122bib29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jscai.2023.101110","type":"journal-article","article-title":"Comprehensive shielding system enhances radiation protection for structural heart procedures","volume":"3","author":"Rizik","year":"2024","journal-title":"J. Soc. Cardiovasc. Angiogr. Interventional"},{"key":"jrpae7122bib30","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1002\/ccd.30490","type":"journal-article","article-title":"A novel comprehensive radiation shielding system eliminates need for personal lead aprons in the catheterization laboratory","volume":"101","author":"Rabah","year":"2023","journal-title":"Catheter Cardiovasc. Interventional"},{"key":"jrpae7122bib31","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.carrev.2024.02.015","type":"journal-article","article-title":"Comprehensive radiation shield minimizes operator radiation exposure in coronary and structural heart procedures","volume":"64","author":"Rizik","year":"2024","journal-title":"Cardiovasc. Revasc. Med."},{"key":"jrpae7122bib32","doi-asserted-by":"publisher","DOI":"10.1155\/2024\/8815778","type":"journal-article","article-title":"Role of different adjunctive protective devices to reduce operator radiation exposure in percutaneous coronary procedures: the RAPTOR study","volume":"2024","author":"Sciahbasi","year":"2024","journal-title":"J Interv Cardiol."},{"key":"jrpae7122bib33","doi-asserted-by":"publisher","DOI":"10.1016\/j.jscai.2023.101184","type":"journal-article","article-title":"Radiation exposure using rampart vs standard lead aprons and shields during invasive cardiovascular procedures","volume":"3","author":"Lisko","year":"2024","journal-title":"J. Soc. Cardiovasc. Angiogr. Interventional"},{"key":"jrpae7122bib34","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/j.amjcard.2023.07.050","type":"journal-article","article-title":"Trial of a novel radiation shielding device to protect staff in the cardiac catheter laboratory","volume":"203","author":"Crowhurst","year":"2023","journal-title":"Am. J. Cardiol."},{"key":"jrpae7122bib35","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/ac8203","type":"journal-article","article-title":"Assessment of occupational dose reduction with the use of a floor mounted mobile lead radiation protection shield","volume":"42","author":"Scott","year":"2022","journal-title":"J. Radiol. Prot."},{"key":"jrpae7122bib36","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.68108","type":"journal-article","article-title":"Radiation exposure during invasive cardiovascular procedures: portable shielding system versus standard lead aprons","volume":"29","author":"Noor","year":"2024","journal-title":"Cureus"},{"key":"jrpae7122bib37","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/s13246-023-01354-0","type":"journal-article","article-title":"Investigation of scatter radiation intensities in the cardiac catheter laboratory: novel versus traditional shielding solutions","volume":"47","author":"Mirjalili","year":"2024","journal-title":"Phys. Eng. Sci. Med."},{"key":"jrpae7122bib38","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.carrev.2021.05.017","type":"journal-article","article-title":"A novel catheterization laboratory radiation shielding system: results of pre-clinical testing","volume":"36","author":"Dixon","year":"2022","journal-title":"Cardiovasc. Revasc. Med."},{"key":"jrpae7122bib39","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahjo.2025.100543","type":"journal-article","article-title":"Comparative effectiveness of the EggNest complete shielding system to standard shielding in the Cath lab","volume":"54","author":"Riley","year":"2025","journal-title":"Am. Hear J. Plus Cardiol. Res. Pract."},{"key":"jrpae7122bib40","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1097\/HP.0000000000001890","type":"journal-article","article-title":"A novel shielding device for cardiac Cath labs","volume":"128","author":"Smith","year":"2025","journal-title":"Health Phys."},{"key":"jrpae7122bib41","doi-asserted-by":"publisher","first-page":"1859","DOI":"10.1007\/s11548-019-02037-6","type":"journal-article","article-title":"Pitfalls in interventional x-ray organ dose assessment\u2014combined experimental and computational phantom study: application to prostatic artery embolization","volume":"14","author":"Roser","year":"2019","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"jrpae7122bib42","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1111\/eci.12628","type":"journal-article","article-title":"Risk of cancer among cardiologists who frequently perform percutaneous coronary interventions: a population-based study","volume":"46","author":"Ho","year":"2016","journal-title":"Eur. J. Clin. Invest."},{"key":"jrpae7122bib43","doi-asserted-by":"publisher","first-page":"2514","DOI":"10.1158\/1055-9965.EPI-06-0482","type":"journal-article","article-title":"Lead, genetic susceptibility, and risk of adult brain tumors","volume":"15","author":"Rajaraman","year":"2006","journal-title":"Cancer Epidemiol. Biomarkers Prevention"},{"key":"jrpae7122bib44","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.2214\/AJR.15.15265","type":"journal-article","article-title":"Cancer risks in U.S. radiologic technologists working with fluoroscopically guided interventional procedures, 1994\u20132008","volume":"206","author":"Rajaraman","year":"2016","journal-title":"Am. J. Roentgenol."},{"key":"jrpae7122bib45","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/S0002-9149(96)00678-9","type":"journal-article","article-title":"Prevalence of spinal disc disease among interventional cardiologists","volume":"79","author":"Ross","year":"1997","journal-title":"Am. J. Cardiol."},{"key":"jrpae7122bib46","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1161\/CIRCINTERVENTIONS.115.003273","type":"journal-article","article-title":"Occupational health risks in cardiac catheterization laboratory workers","volume":"9","author":"Andreassi","year":"2016","journal-title":"Circ. Cardiovasc. Interventional"},{"key":"jrpae7122bib47","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1016\/j.jacc.2014.11.056","type":"journal-article","article-title":"Occupational health hazards of working in the interventional laboratory: a multisite case control study of physicians and allied staff","volume":"65","author":"Orme","year":"2015","journal-title":"J. Am. Coll Cardiol."},{"key":"jrpae7122bib48","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1111\/j.1540-8167.2011.02041.x","type":"journal-article","article-title":"Prevalence and risk factors for cervical and lumbar spondylosis in interventional electrophysiologists","volume":"22","author":"Birnie","year":"2011","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"jrpae7122bib49","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.2214\/ajr.161.5.8273614","type":"journal-article","article-title":"Lightweight aprons for protection against scattered radiation during fluoroscopy","volume":"161","author":"Hubbert","year":"1993","journal-title":"Am. J. Roentgenol."},{"key":"jrpae7122bib50","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1002\/iis2.12876","type":"journal-article","article-title":"A meta\u2010model for integrating human factors into system engineering","volume":"32","author":"Amokrane\u2010Ferka","year":"2022","journal-title":"INCOSE Int. Symp."},{"key":"jrpae7122bib51","first-page":"3","author":"Nickel","year":"2020","type":"book"},{"key":"jrpae7122bib52","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1177\/15266028231160661","type":"journal-article","article-title":"StemRad MD, an exoskeleton-based radiation protection system, reduces ergonomic posture risk based on a prospective observational study","volume":"31","author":"Katsarou","year":"2024","journal-title":"J. Endovasc. Ther."},{"key":"jrpae7122bib53","doi-asserted-by":"publisher","first-page":"E687","DOI":"10.1002\/ccd.29894","type":"journal-article","article-title":"Evaluation of a suspended radiation protection system to reduce operator exposure in cardiology interventional procedures","volume":"98","author":"Zanca","year":"2021","journal-title":"Catheter Cardiovasc. Interventional"}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T06:28:30Z","timestamp":1780554510000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae7122"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,1]]},"references-count":53,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,6,4]]},"published-print":{"date-parts":[[2026,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ae7122","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,1]]},"assertion":[{"value":"Occupational dose attenuation and dosimetric performance of autonomous radiation protection systems in fluoroscopy: a scoping review with implications for the role of conventional lead aprons","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-01-19","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-05-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-04","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}