{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T07:03:34Z","timestamp":1784271814654,"version":"3.55.0"},"reference-count":36,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T00:00:00Z","timestamp":1784246400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T00:00:00Z","timestamp":1784246400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"CERN Knowledge Transfer Fund for Medical Applications"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2026,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    In low-energy photon fields, such as those encountered during fluoroscopy-guided interventions, the current operational quantity for area dosimetry, ambient dose equivalent\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi>H<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mo>\u2217<\/mml:mo>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    (10), overestimates effective dose by roughly a factor of two. International Commission on Radiation Units and measurements (ICRU) Report 95 introduces a revised set of operational quantities intended to better align with protection quantities, replacing\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi>H<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mo>\u2217<\/mml:mo>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    (10) with ambient dose\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi>H<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mo>\u2217<\/mml:mo>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    for area monitoring. Experimental data validating these changes in realistic clinical environments remain scarce. This study examines the differences between current and newly proposed operational quantities in scattered radiation fields representative of occupational staff exposure during fluoroscopy-guided procedures. Measurements were performed using a Timepix4 hybrid pixel detector operated simultaneously as an x-ray spectrometer and dosimeter. The detector provides energy-resolved photon fluence measurements convertible into operational dose quantities via published fluence-to-dose conversion coefficients. Measurement campaigns were conducted in a urology theatre and an interventional cardiology (IC) theatre under realistic clinical conditions. Photon spectra were recorded at staff positions representative of standard procedures and converted into current and newly proposed quantities relevant to whole-body, skin, and eye lens exposure. The influence of beam angulation and additional shielding was further investigated in the IC theatre. For whole-body exposure, ratios between\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi>H<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mo>\u2217<\/mml:mo>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi>H<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mo>\u2217<\/mml:mo>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    (10) ranged from 0.52 in urology to 0.59 in IC. Quantities relevant to skin and eye lens exposure remained close to unity, with deviations not exceeding 5% and 8%, respectively. Beam angulation and shielding induced only minor variations in these ratios, below 5%. These results provide the first experimental validation of ICRU Report 95 quantities in interventional workplaces. Whole-body dosimetry is most affected by the transition, while skin and eye lens monitoring should remain largely unchanged. Ambient dosimeters calibrated in\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi>H<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mo>\u2217<\/mml:mo>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    (10) used in low-energy photon fields may be recalibrated using a single procedure-specific calibration factor, whereas calibration procedures for skin and eye lens dosimeters may remain unchanged.\n                  <\/jats:p>","DOI":"10.1088\/1361-6498\/ae8272","type":"journal-article","created":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T22:49:01Z","timestamp":1782427741000},"page":"031514","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Impact of the ICRU\/ICRP proposal on operational quantities during interventional procedures: investigation through spectral measurements"],"prefix":"10.1088","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-3156-8577","authenticated-orcid":true,"given":"Tristan","family":"Genetay","sequence":"first","affiliation":[{"name":"European Organization for Nuclear Research"},{"name":"Lausanne University Hospital and Lausanne University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-4876-6853","authenticated-orcid":true,"given":"Nicolas","family":"Cherbuin","sequence":"additional","affiliation":[{"name":"Lausanne University Hospital and Lausanne University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2297-8865","authenticated-orcid":true,"given":"Lucia","family":"Gallego Manzano","sequence":"additional","affiliation":[{"name":"Lausanne University Hospital and Lausanne University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6182-8659","authenticated-orcid":true,"given":"Thomas","family":"Otto","sequence":"additional","affiliation":[{"name":"European Organization for Nuclear Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2076-0296","authenticated-orcid":false,"given":"Fran\u00e7ois","family":"Bochud","sequence":"additional","affiliation":[{"name":"Lausanne University Hospital and Lausanne University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5013-6844","authenticated-orcid":false,"given":"Pierre","family":"Carbonez","sequence":"additional","affiliation":[{"name":"European Organization for Nuclear Research"},{"name":"University of Otago"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2481-2049","authenticated-orcid":false,"given":"Marie","family":"Nowak","sequence":"additional","affiliation":[{"name":"Lausanne University Hospital and Lausanne University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1790-3236","authenticated-orcid":false,"given":"Jerome","family":"Damet","sequence":"additional","affiliation":[{"name":"Lausanne University Hospital and Lausanne University"},{"name":"University of Otago"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,7,17]]},"reference":[{"key":"jrpae8272bib1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0146-6453(91)90066-P","type":"journal-article","article-title":"1990 Recommendations of the international commission on radiological protection. ICRP publication 60","volume":"21 (1\u20133)","author":"ICRP","year":"1991","journal-title":"Ann. ICRP"},{"key":"jrpae8272bib2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2007.10.003","type":"journal-article","article-title":"The 2007 Recommendations of the international commission on radiological protection. ICRP publication 103","volume":"37 (2\u20134)","author":"ICRP","year":"2007","journal-title":"Ann. ICRP"},{"key":"jrpae8272bib3","first-page":"1","type":"journal-article","article-title":"ICRU report 39: determination of dose equivalents resulting from external radiation sources","volume":"os20","author":"ICRU","year":"1985","journal-title":"J. ICRU"},{"key":"jrpae8272bib4","first-page":"1","type":"journal-article","article-title":"ICRU report 51: quantities and units in radiation protection dosimetry","volume":"os26","author":"ICRU","year":"1993","journal-title":"J. ICRU"},{"key":"jrpae8272bib5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/jicru\/os29.2.Report57","type":"journal-article","article-title":"ICRU report 57: conversion coefficients for use in radiological protection against external radiation","volume":"os29","author":"ICRU","year":"1998","journal-title":"J. ICRU"},{"key":"jrpae8272bib6","first-page":"1","type":"journal-article","article-title":"ICRP Publication 74: conversion coefficients for use in radiological protection against external radiation","volume":"26 (3\u20134)","author":"ICRP","year":"1996","journal-title":"Ann. ICRP"},{"key":"jrpae8272bib7","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1177\/1473669120966222","type":"journal-article","article-title":"ICRU report 95 : operational quantities for external radiation exposure","volume":"20","author":"ICRU","year":"2020","journal-title":"J. ICRU"},{"key":"jrpae8272bib8","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.icrp.2009.09.001","type":"journal-article","article-title":"Realistic reference phantoms: an ICRP\/ICRU joint effort","volume":"39 (2)","author":"ICRP","year":"2009","journal-title":"Ann. ICRP"},{"key":"jrpae8272bib9","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.1088\/1361-6498\/ac0d63","type":"journal-article","article-title":"Impact of new operational dosimetric quantities on individual monitoring services","volume":"41","author":"Caresana","year":"2021","journal-title":"J. Radiol. Prot."},{"key":"jrpae8272bib10","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1093\/rpd\/ncaa078","type":"journal-article","article-title":"Response of current photon personal dosemeters to new operational quantities","volume":"190","author":"Ekendahl","year":"2020","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpae8272bib11","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1093\/rpd\/ncx243","type":"journal-article","article-title":"The ICRU proposal for new operational quantities for external radiation","volume":"180","author":"Otto","year":"2018","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpae8272bib12","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-75257-5","type":"journal-article","article-title":"Characterisation and mapping of scattered radiation fields in interventional radiology theatres","volume":"10","author":"Nowak","year":"2020","journal-title":"Sci. Rep."},{"key":"jrpae8272bib13","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1093\/rpd\/ncad290","type":"journal-article","article-title":"Energy spectrum measurement of scattered x-rays during IVR procedure","volume":"200","author":"Oikawa","year":"2024","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpae8272bib14","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.ejmp.2019.11.002","type":"journal-article","article-title":"Relative response of dosimeters to variations in scattered x-ray energy spectra encountered in interventional radiology","volume":"67","author":"Masterson","year":"2019","journal-title":"Phys. Medica"},{"key":"jrpae8272bib15","author":"UNSCEAR","year":"2022","type":"conference-proceedings"},{"key":"jrpae8272bib16","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/ae3f3f","type":"journal-article","article-title":"Evaluation of survey meter responses to the new operational quantities proposed by ICRU Report 95","volume":"46","author":"de Santana","year":"2026","journal-title":"J. Radiol. Prot."},{"key":"jrpae8272bib17","doi-asserted-by":"publisher","first-page":"1313","DOI":"10.1093\/rpd\/ncac154","type":"journal-article","article-title":"Response of current area dosemeters to new operational quantities","volume":"198","author":"\u010cemusov\u00e1","year":"2022","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpae8272bib18","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/14\/01\/P01010","type":"journal-article","article-title":"Response of photon dosimeters and survey instruments to new operational quantities proposed by ICRU RC26","volume":"14","author":"Otto","year":"2019","journal-title":"J. Instrum."},{"key":"jrpae8272bib19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2025.105687","type":"journal-article","article-title":"X-ray imaging dosimeter performance in standard and non-standard radiography radiation fields in terms of air kerma","volume":"141","author":"Kr\u017eanovi\u0107","year":"2026","journal-title":"Phys. Medica"},{"key":"jrpae8272bib20","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2021.106515","type":"journal-article","article-title":"Performance testing of dosimeters used in interventional radiology: results from the VERIDIC project","volume":"141","author":"Kr\u017eanovi\u0107","year":"2021","journal-title":"Radiat. Meas."},{"key":"jrpae8272bib21","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2025.107570","type":"journal-article","article-title":"RQR beam qualities measurement with the Timepix4 detector","volume":"191","author":"Genetay","year":"2026","journal-title":"Radiat. Meas."},{"key":"jrpae8272bib22","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/17\/01\/C01044","type":"journal-article","article-title":"Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning","volume":"17","author":"Llopart","year":"2022","journal-title":"J. Instrum."},{"key":"jrpae8272bib23","doi-asserted-by":"publisher","DOI":"10.1016\/j.cpc.2025.109658","type":"journal-article","article-title":"DataPix4: A C++ framework for Timepix4 configuration and read-out","volume":"314","author":"Cavallini","year":"2025","journal-title":"Comput. Phys. Commun."},{"key":"jrpae8272bib24","article-title":"Medical diagnostic x-ray equipment - Radiation conditions for use in the determination of characteristics","author":"IEC","year":"2025","type":"other"},{"key":"jrpae8272bib25","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-026-49696-5","type":"journal-article","article-title":"A dosimetry innovation using hybrid pixel detectors in hospital theatres","volume":"16","author":"Genetay","year":"2026","journal-title":"Sci. Rep."},{"key":"jrpae8272bib26","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/adda56","type":"journal-article","article-title":"Re-calculation of air kerma to dose-equivalent conversion coefficients for mono-energetic photons","volume":"45","author":"\u0160olc","year":"2025","journal-title":"J. Radiol. Prot."},{"key":"jrpae8272bib27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/14736691251392645","type":"journal-article","article-title":"ICRU Report 100, radiation protection dosimetry for external sources of ionizing radiation","volume":"25","author":"ICRU","year":"2025","journal-title":"J. ICRU"},{"key":"jrpae8272bib28","article-title":"Guide to the expression of uncertainty in measurement \u2014 Part 6: Developing and using measurement models","author":"Joint Committee for Guides in Metrology","year":"2020","type":"other"},{"key":"jrpae8272bib29","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/acb780","type":"journal-article","article-title":"Impact of the implementation of the new radiation quantities recommended by ICRU\/ICRP for practical use in interventional radiology: a Monte Carlo study","volume":"43","author":"Abdelrahman","year":"2023","journal-title":"J. Radiol. Prot."},{"key":"jrpae8272bib30","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ejmp.2020.08.016","type":"journal-article","article-title":"A parametric study of occupational radiation dose in interventional radiology by Monte-Carlo simulations","volume":"78","author":"Abdelrahman","year":"2020","journal-title":"Phys. Medica"},{"key":"jrpae8272bib31","article-title":"Eurados Report 2022-02: evaluation of the impact of the new icru operational quantities and recommendations for their practical application","author":"Gilvin","year":"2022","type":"other"},{"key":"jrpae8272bib32","article-title":"Radiation protection instrumentation \u2014 Ambient and\/or directional dose equivalent (rate) meters and\/or monitors for beta, X and gamma radiation \u2014 Part 1: Portable workplace and environmental meters and monitors","author":"IEC","year":"2009","type":"other"},{"key":"jrpae8272bib33","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1093\/rpd\/ncy105","type":"journal-article","article-title":"Testing different area dosemeters concerning their behaviour in pulsed radiation fields","volume":"182","author":"Friedrich","year":"2018","journal-title":"Radiat. Prot. Dosim."},{"key":"jrpae8272bib34","doi-asserted-by":"publisher","first-page":"3059","DOI":"10.1007\/s00590-023-03538-6","type":"journal-article","article-title":"Radiation dose to staff from medical x-ray scatter in the orthopaedic theatre","volume":"33","author":"Dorman","year":"2023","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"jrpae8272bib35","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2026.171844","type":"journal-article","article-title":"Extended angular response investigation of a Timepix4 silicon sensor assembly using broad x-ray spectra","volume":"1092","author":"Genetay","year":"2026","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"jrpae8272bib36","doi-asserted-by":"publisher","first-page":"63","DOI":"10.5194\/jsss-10-63-2021","type":"journal-article","article-title":"Method for fast determination of the angle of ionizing radiation incidence from data measured by a Timepix3 detector","volume":"10","author":"Lehner","year":"2021","journal-title":"J. Sens. Sens. Syst."}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T06:11:50Z","timestamp":1784268710000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/ae8272"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,17]]},"references-count":36,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,7,17]]},"published-print":{"date-parts":[[2026,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/ae8272","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,17]]},"assertion":[{"value":"Impact of the ICRU\/ICRP proposal on operational quantities during interventional procedures: investigation through spectral measurements","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of the Society for Radiological Protection by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-04-05","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-25","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-17","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}