{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T06:56:13Z","timestamp":1790578573333,"version":"4.1.0"},"reference-count":48,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"vor","delay-in-days":27,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"tdm","delay-in-days":27,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Radiol. Prot."],"published-print":{"date-parts":[[2026,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The development of sustainable and lead-free shielding materials is of increasing interest for diagnostic radiology facilities, particularly in low- and middle-income countries where cost, material availability, and environmental considerations are important factors. This study evaluates the radiation shielding performance of fired clay bricks (FCB), concrete, and stainless steel (SS) as alternative structural materials for x-ray facilities operating up to 150 kVp using Monte Carlo simulations with the PHITS code. Mass attenuation coefficients and effective atomic numbers were computed to characterise photon attenuation properties and guide the design of multilayer shielding assemblies. Two concrete-encapsulated assemblies were engineered: a standard composite (C\n                    <jats:sub>8<\/jats:sub>\n                    -FCB\n                    <jats:sub>200<\/jats:sub>\n                    -C\n                    <jats:sub>8<\/jats:sub>\n                    , 2.32 mm lead equivalent) and a steel-reinforced composite (SS\n                    <jats:sub>2<\/jats:sub>\n                    -C\n                    <jats:sub>8<\/jats:sub>\n                    -FCB\n                    <jats:sub>200<\/jats:sub>\n                    -C\n                    <jats:sub>8<\/jats:sub>\n                    , 2.73 lead equivalent). Their performance was benchmarked against a conventional 2 mm lead barrier. Photon flux distributions and effective dose rates (EDR) were evaluated at primary (Cell 20) and secondary (Cells 22, 24, 26) shielding boundaries for x-ray tube potentials ranging from 80 to 150 kVp. At 150 kVp, the lead reference barrier reduced the transmitted EDR to 7.09\u00d710\n                    <jats:sup>\u201309<\/jats:sup>\n                    <jats:italic>\u00b5<\/jats:italic>\n                    Sv h\n                    <jats:sup>\u20131<\/jats:sup>\n                    at the primary barrier and below 1.79\u00d710\n                    <jats:sup>\u201312<\/jats:sup>\n                    <jats:italic>\u00b5<\/jats:italic>\n                    Sv h\n                    <jats:sup>\u20131<\/jats:sup>\n                    at the secondary barriers. A comparative analysis of the EDR recorded behind the alternative barriers reveals that for the secondary barriers, the standard C\n                    <jats:sub>8<\/jats:sub>\n                    -FCB\n                    <jats:sub>200<\/jats:sub>\n                    -C\n                    <jats:sub>8<\/jats:sub>\n                    configuration was fully adequate across the entire investigated tube voltage range (80\u2013150 kVp). Conversely, for the primary barrier, the reinforced SS\n                    <jats:sub>6<\/jats:sub>\n                    -C\n                    <jats:sub>8<\/jats:sub>\n                    -FCB\n                    <jats:sub>200<\/jats:sub>\n                    -C\n                    <jats:sub>8<\/jats:sub>\n                    composite is strictly required to provide sufficient shielding at 150 kVp. These results demonstrate the potential of locally available, lead-free composite materials as cost-effective and environmentally sustainable alternatives for radiation shielding in diagnostic radiology facilities while supporting optimization and ALARA principles.\n                  <\/jats:p>","DOI":"10.1088\/1361-6498\/aea2a0","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T22:48:14Z","timestamp":1788562094000},"page":"031537","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Investigations of lead-free multilayer shielding for diagnostic radiology using Monte Carlo simulations"],"prefix":"10.1088","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6296-4612","authenticated-orcid":true,"given":"Fran\u00e7ois","family":"Mbozeko Mouongue","sequence":"first","affiliation":[{"name":"University of Yaound\u00e9 1"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0785-0492","authenticated-orcid":true,"given":"Jean F\u00e9lix","family":"Beyala Ateba","sequence":"additional","affiliation":[{"name":"Radiological Safety and Nuclear Security Authority, P O Box"},{"name":"University of Yaound\u00e9 I"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4740-1146","authenticated-orcid":true,"given":"Cebastien Joel","family":"Guembou Shouop","sequence":"additional","affiliation":[{"name":"Radiological Safety and Nuclear Security Authority, P O Box"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bonaventure","family":"Mvogo Aloa","sequence":"additional","affiliation":[{"name":"University of Yaound\u00e9 I"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1419-6246","authenticated-orcid":true,"given":"Henri Paul","family":"Ekobena Fouda","sequence":"additional","affiliation":[{"name":"University of Yaound\u00e9 1"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,9,28]]},"reference":[{"key":"jrpaea2a0bib1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1051\/epjn\/2022044","type":"journal-article","article-title":"Medical applications of ionizing radiation and radiation protection for European patients, population and environment","volume":"8","author":"Hierry-Chef","year":"2022","journal-title":"EPJ Nucl. Sci. Technol."},{"key":"jrpaea2a0bib2","author":"UNSCEAR","year":"2000","journal-title":"Sources and effects of ionizing radiation: UNSCEAR 2000 report to the General Assembly, with scientific annexes (Volume II: Effects)","type":"journal-article"},{"key":"jrpaea2a0bib3","doi-asserted-by":"publisher","first-page":"145","DOI":"10.3344\/kjp.2018.31.3.145","type":"journal-article","article-title":"Three principles for radiation safety: time, distance, and shielding","volume":"31","author":"Kim","year":"2018","journal-title":"Korean J. Pain."},{"key":"jrpaea2a0bib4","doi-asserted-by":"publisher","first-page":"254-61","DOI":"10.1016\/j.neuro.2016.04.006","type":"journal-article","article-title":"Consequences of lead exposure, and it is emerging role as an epigenetic modifier in the aging brain","volume":"56","author":"Eid","year":"2015","journal-title":"Neurotoxicology"},{"key":"jrpaea2a0bib5","doi-asserted-by":"publisher","first-page":"284","DOI":"10.3109\/1547691X.2011.592162","type":"journal-article","article-title":"Effects of environmental lead exposure on T-helper cell-specific cytokines in children","volume":"8","author":"Hsiao","year":"2011","journal-title":"J. Immunotoxicol."},{"key":"jrpaea2a0bib6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.radphyschem.2019.108439","type":"journal-article","article-title":"Conventional and new lead-free radiation shielding materials for radiation protection in nuclear medicine: a review","volume":"165","author":"AbuAlRoos","year":"2019","journal-title":"Radiat. Phys. Chem."},{"key":"jrpaea2a0bib7","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1080\/15563650701816448","type":"journal-article","article-title":"Two cases of acute lead poisoning due to occupational exposure to lead","volume":"46","author":"Ogawa","year":"2008","journal-title":"Clin. Toxicol."},{"key":"jrpaea2a0bib8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1063\/5.0022959","type":"journal-article","article-title":"A study of x-ray radiation shielding properties of bricks contained barium sulfate","volume":"2279","author":"Kiatwattanacharoen","year":"2020","journal-title":"AIP Conf, Proc"},{"key":"jrpaea2a0bib9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jrras.2026.102255","type":"journal-article","article-title":"Sustainable and high-performance solutions for radiation shielding in concrete: recent advances and future directions","volume":"19","author":"Al-Abdullah","year":"2026","journal-title":"J. Radiat. Res. Appl. Sci."},{"key":"jrpaea2a0bib10","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2024.112245","type":"journal-article","article-title":"Experimental investigation of fired clay bricks for gamma radiation shielding","volume":"226","author":"Hanfi","year":"2025","journal-title":"Radiat. Phys. Chem."},{"key":"jrpaea2a0bib11","doi-asserted-by":"publisher","first-page":"0","DOI":"10.1088\/2053-1591\/ac5e8d\/","type":"journal-article","article-title":"Barite concrete-based cement composites for 252Cf spontaneous neutron and 60Co\/192Ir shielding based on Monte Carlo computation","volume":"9","author":"Joel","year":"2022","journal-title":"Mater. Res. Express"},{"key":"jrpaea2a0bib12","doi-asserted-by":"publisher","first-page":"1183","DOI":"10.1038\/s41598-022-05221-y","type":"journal-article","article-title":"Monte Carlo optimum management of 241Am\/Be disused sealed radioactive sources","volume":"12","author":"Guembou Shouop","year":"2022","journal-title":"Sci. Rep."},{"key":"jrpaea2a0bib13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jobe.2024.110800","type":"journal-article","article-title":"Radiation-shielding concrete: a review of materials, performance, and the impact of radiation on concrete properties","volume":"97","author":"Onaizi","year":"2024","journal-title":"J. Build. Eng."},{"key":"jrpaea2a0bib14","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1177\/0734242X251405995","type":"journal-article","article-title":"Towards sustainable radiation shielding: a literature review of agricultural waste-enhanced concrete composites","volume":"44","author":"Amponsah","year":"2026","journal-title":"J. A Sustain. Circ. Econ."},{"key":"jrpaea2a0bib15","doi-asserted-by":"publisher","first-page":"784","DOI":"10.1140\/epjp\/s13360-020-00797-8","type":"journal-article","article-title":"Shielding design for high-intensity Co-60 and Ir-192 gamma sources used in industrial radiography based on PHITS Monte Carlo simulations","volume":"135","author":"Guembou Shouop","year":"2020","journal-title":"Eur. Phys. J. Plus."},{"key":"jrpaea2a0bib16","doi-asserted-by":"publisher","DOI":"10.1080\/19397038.2026.2630466","type":"journal-article","article-title":"Structural performance and radiation shielding of low-carbonheavyweight geopolymer concrete with barite aggregate","volume":"19","author":"Sylisomchanh","year":"2026","journal-title":"Int. J. Sustain. Eng."},{"key":"jrpaea2a0bib17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhazmat.2020.124201","type":"journal-article","article-title":"Radiation shielding concrete with alternate constituents: an approach to address multiple hazards","volume":"404","author":"Tyagi","year":"2012","journal-title":"J. Hazard. Mater."},{"key":"jrpaea2a0bib18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.pnucene.2004.09.015","type":"journal-article","article-title":"The shielding of \u03b3-rays by concretes produced with barite","volume":"46","author":"Akkurt","year":"2005","journal-title":"Prog. Nucl. Energy"},{"key":"jrpaea2a0bib19","doi-asserted-by":"publisher","DOI":"10.1063\/1.5144923","type":"journal-article","article-title":"New Cf-252 neutron source shielding design based Monte Carlo simulation using material combination","volume":"10","author":"Guembou Shouop","year":"2020","journal-title":"AIP Adv."},{"key":"jrpaea2a0bib20","doi-asserted-by":"publisher","DOI":"10.1063\/5.0063005","type":"journal-article","article-title":"241 Am\/Be source optimum geometry for DSRS management- based Monte Carlo simulations","volume":"11","author":"Guembou Shouop","year":"2021","journal-title":"AIP Adv."},{"key":"jrpaea2a0bib21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/2053-1591\/AC5E8D","type":"journal-article","article-title":"Barite concrete-based cement composites for 252Cf spontaneous neutron and 60Co\/192Ir shielding based on Monte Carlo computation","volume":"9","author":"Guembou Shouop","year":"2022","journal-title":"Mater. Res. Express"},{"key":"jrpaea2a0bib22","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2020.118908","type":"journal-article","article-title":"The use of rocks in lieu of bricks and concrete as radiation shielding barriers at low gamma and nuclear medicine energies","volume":"251","author":"Alorfi","year":"2020","journal-title":"Constr. Build. Mater."},{"key":"jrpaea2a0bib23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/ma15175908","type":"journal-article","article-title":"Estimating radiation shielding of fired clay bricks using ANN and GEP approaches","volume":"15","author":"Amin","year":"2022","journal-title":"Materials"},{"key":"jrpaea2a0bib24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.mex.2024.102744","type":"journal-article","article-title":"Investigation of red clay and waste glass composite bricks for ionizing radiation shielding","volume":"12","author":"Nzivulu","year":"2024","journal-title":"MethodsX"},{"key":"jrpaea2a0bib25","doi-asserted-by":"publisher","first-page":"12","DOI":"10.22259\/2637-5826.0601003","type":"journal-article","article-title":"eco-Friendly alternatives to lead in x-ray shielding: a comprehensive Review","volume":"6","author":"Osman","year":"2024","journal-title":"Open Access J. Phys."},{"key":"jrpaea2a0bib26","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1016\/j.radphyschem.2004.04.040","type":"journal-article","article-title":"WinXCom\u2014a program for calculating x-ray attenuation coefficients","volume":"71","author":"Gerward","year":"2004","journal-title":"Rad. Phys. Chem."},{"key":"jrpaea2a0bib27","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/S0969-806X(00)00324-8","type":"journal-article","article-title":"x-ray absorption in matter Reengineering XCOM","volume":"60","author":"Gerward","year":"2001","journal-title":"Rad. Phys. Chem."},{"key":"jrpaea2a0bib28","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1007\/s41365-017-0253-4","type":"journal-article","article-title":"Simulations of mass attenuation coefficients for shielding materials using the MCNP-X code","volume":"28","author":"Tekin","year":"2017","journal-title":"Nucl. Sci. Tech."},{"key":"jrpaea2a0bib29","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1097\/01.HP.0000158736.59917.93","type":"journal-article","article-title":"Recent history of the shielding of medical x-ray imaging facilities","volume":"88","author":"Archer","year":"2005","journal-title":"Health Phys."},{"key":"jrpaea2a0bib30","article-title":"Structural shielding design for medical x-ray imaging facilities","author":"NCRP","year":"2004","type":"other"},{"key":"jrpaea2a0bib31","doi-asserted-by":"publisher","first-page":"879","DOI":"10.15669\/pnst.4.879","type":"journal-article","article-title":"Overview of the PHITS code and its application to medical physics","volume":"4","author":"Sato","year":"2014","journal-title":"Prog. Nucl. Sci. Technol."},{"key":"jrpaea2a0bib32","doi-asserted-by":"publisher","first-page":"127-35","DOI":"10.1080\/00223131.2023.2275736","type":"journal-article","article-title":"Recent improvements of the particle and heavy ion transport code system\u2014PHITS version 3.33","volume":"61","author":"Sato","year":"2023","journal-title":"J. Nucl. Sci. Technol."},{"key":"jrpaea2a0bib33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/00223131.2017.1419890","type":"journal-article","article-title":"Features of particle and heavy ion transport code system (PHITS) version 3. 02","volume":"55","author":"Sato","year":"2018","journal-title":"J. Nucl. Sci. Technol."},{"key":"jrpaea2a0bib34","doi-asserted-by":"publisher","first-page":"48","DOI":"10.14338\/IJPT-17-00029.1","type":"journal-article","article-title":"Benchmarking of PHITS for carbon ion therapy","volume":"4","author":"Puchalska","year":"2017","journal-title":"Int. J. Part. Ther."},{"key":"jrpaea2a0bib35","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1080\/09553002.2022.2013572","type":"journal-article","article-title":"Track-structure modes in particle and heavy ion transport code system (PHITS): application to radiobiological research","volume":"98","author":"Matsuya","year":"2022","journal-title":"Int. J. Radiat. Biol."},{"key":"jrpaea2a0bib36","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1007\/s12194-021-00628-0","type":"journal-article","article-title":"Medical application of particle and heavy ion transport code system PHITS","volume":"14","author":"Furuta","year":"2021","journal-title":"Radiol. Phys. Technol."},{"key":"jrpaea2a0bib37","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/00223131.2023.2275737","type":"journal-article","article-title":"Experimental and computational verifications of the dose calculation accuracy of PHITS for high-energy photon beam therapy","volume":"61","author":"Kuga","year":"2023","journal-title":"J. Nucl. Sci. Technol."},{"key":"jrpaea2a0bib38","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1118\/1.596686","type":"journal-article","article-title":"Molybdenum target x-ray spectra: a semiepirical model","volume":"18","author":"Tucker","year":"1991","journal-title":"Med. Phys."},{"key":"jrpaea2a0bib39","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1118\/1.596709","type":"journal-article","article-title":"Semiempirical model for generating tungsten tardget x-ray spectra","volume":"18","author":"Tucker","year":"1991","journal-title":"Med. Phys."},{"key":"jrpaea2a0bib40","author":"Johns","year":"1983","type":"book"},{"key":"jrpaea2a0bib41","author":"Alpen","year":"1998","edition":"2nd edn","type":"book"},{"key":"jrpaea2a0bib42","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2024.138978","type":"journal-article","article-title":"Evaluation of the shear behavior of RC beams strengthened with prestressing BFRP grids","volume":"452","author":"Zhou","year":"2024","journal-title":"Constr. Build. Mater."},{"key":"jrpaea2a0bib43","doi-asserted-by":"publisher","DOI":"10.1051\/radiopro\/2026002","type":"journal-article","article-title":"Enhancing shielding designs in medical radiography services in Cameroon using PHITS monte carlo simulations","volume":"61","author":"Fran\u00e7ois","year":"2026","journal-title":"Radioprotection"},{"key":"jrpaea2a0bib44","article-title":"Radiation protection and safety in medical uses of ionizing radiation","author":"IAEA","year":"2018","type":"web-resource"},{"key":"jrpaea2a0bib45","article-title":"1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP 21 (1\u20133)","author":"ICRP","year":"1991","type":"journal-article"},{"key":"jrpaea2a0bib46","author":"Munro","year":"2004","type":"book"},{"key":"jrpaea2a0bib47","article-title":"MCNP code version 6.3.0 theory & user manual","author":"Joel","year":"2022","type":"other"},{"key":"jrpaea2a0bib48","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1080\/00223131.2023.2275736","type":"journal-article","article-title":"Recent improvements of the particle and heavy ion transport code system\u2014PHITS version 3. 33","volume":"61","author":"Sato","year":"2024","journal-title":"J. Nucl. Sci. Technol."}],"container-title":["Journal of Radiological Protection"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T06:21:04Z","timestamp":1790576464000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6498\/aea2a0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":48,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,9,28]]},"published-print":{"date-parts":[[2026,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6498\/aea2a0","relation":{},"ISSN":["0952-4746","1361-6498"],"issn-type":[{"value":"0952-4746","type":"print"},{"value":"1361-6498","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,1]]},"assertion":[{"value":"Investigations of lead-free multilayer shielding for diagnostic radiology using Monte Carlo simulations","name":"article_title","label":"Article Title"},{"value":"Journal of Radiological Protection","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-03-16","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-04","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-28","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}