{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T14:15:41Z","timestamp":1783174541268,"version":"3.54.6"},"reference-count":24,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2017,1,13]],"date-time":"2017-01-13T00:00:00Z","timestamp":1484265600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2017,1,13]],"date-time":"2017-01-13T00:00:00Z","timestamp":1484265600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000062","name":"National Institute of Diabetes and Digestive and Kidney Diseases","doi-asserted-by":"crossref","award":["1R21DK091555-01A1"],"award-info":[{"award-number":["1R21DK091555-01A1"]}],"id":[{"id":"10.13039\/100000062","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Meas. Sci. Technol."],"published-print":{"date-parts":[[2017,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This paper designs and fabricates an instrumented catheter for instantaneous measurement of distributed urethral pressure profiles. Since the catheter enables a new type of urological measurement, a process for accurate\n                    <jats:italic>ex vivo<\/jats:italic>\n                    validation of the catheter is developed. A flexible sensor strip is first fabricated with nine pressure sensors and integrated electronic pads for an associated sensor IC chip. The flexible sensor strip and associated IC chip are assembled on a 7 Fr Foley catheter. A sheep bladder and urethra are extracted and used in an\n                    <jats:italic>ex vivo<\/jats:italic>\n                    set up for verification of the developed instrumented catheter. The bladder-urethra are suspended in a test rig and pressure cuffs placed to apply known static and dynamic pressures around the urethra. A significant challenge in the performance of the sensor system is the presence of parasitics that introduce large bias and drift errors in the capacitive sensor signals. An algorithm based on use of reference parasitic transducers is used to compensate for the parasitics. Extensive experimental results verify that the developed compensation method works effectively. Results on pressure variation profiles circumferentially around the urethra and longitudinally along the urethra are presented. The developed instrumented catheter will be useful in improved urodynamics to more accurately diagnose the source of urinary incontinence in patients.\n                  <\/jats:p>","DOI":"10.1088\/1361-6501\/aa5434","type":"journal-article","created":{"date-parts":[[2016,12,17]],"date-time":"2016-12-17T01:22:05Z","timestamp":1481937725000},"page":"035702","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["Instrumented urethral catheter and its\n                    <i>ex vivo<\/i>\n                    validation in a sheep urethra"],"prefix":"10.1088","volume":"28","author":[{"given":"Mahdi","family":"Ahmadi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajesh","family":"Rajamani","sequence":"additional","affiliation":[{"name":"University of Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerald","family":"Timm","sequence":"additional","affiliation":[{"name":"University of Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serdar","family":"Sezen","sequence":"additional","affiliation":[{"name":"St. Cloud State University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2017,1,13]]},"reference":[{"key":"mstaa5434bib001","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/BF00373608","type":"journal-article","article-title":"The standardization of terminology of lower urinary tract function recommended by the international continence society","volume":"1","author":"Abrams","year":"1990","journal-title":"Int. Urogynecol. J."},{"key":"mstaa5434bib002","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1159\/000480832","type":"journal-article","article-title":"Urinary incontinence in Belgium: a population based epidemiological survey","volume":"32","author":"Schulman","year":"1997","journal-title":"Eur. Urol."},{"key":"mstaa5434bib003","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1111\/j.1532-5415.1990.tb03504.x","type":"journal-article","article-title":"Prevalence and incidence of urinary incontinence in community-dwelling populations","volume":"38","author":"Herzog","year":"1990","journal-title":"J. Am. Geriat. Soc."},{"key":"mstaa5434bib004","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1159\/000019750","type":"journal-article","article-title":"Prevalence of urinary incontinence among Spanish older people living at home","volume":"34","author":"Damian","year":"1998","journal-title":"Eur. Urol."},{"key":"mstaa5434bib005","first-page":"1022","type":"journal-article","article-title":"Prevalence of urinary incontinence and other urological symptoms in the noninstitutionalized elderly","volume":"136","author":"Diokno","year":"1996","journal-title":"J. Urol."},{"key":"mstaa5434bib006","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1046\/j.1442-2042.2000.00147.x","type":"journal-article","article-title":"Urinary incontinence among community-dwelling people aged 40 years or older in Japan: prevalence, risk factors, knowledge and self perception","volume":"7","author":"Ueda","year":"2000","journal-title":"Int. J. Urol."},{"key":"mstaa5434bib007","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/S0090-4295(97)00623-7","type":"journal-article","article-title":"Economic costs of urinary incontinence in 1995","volume":"51","author":"Wagner","year":"1998","journal-title":"Urology"},{"key":"mstaa5434bib008","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1111\/j.1464-410X.1979.tb03585.x","type":"journal-article","article-title":"Urinary incontinence: prevalence and needs","volume":"51","author":"Fenely","year":"1979","journal-title":"Br. J. Urol."},{"key":"mstaa5434bib009","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1093\/ageing\/8.2.81","type":"journal-article","article-title":"The prevalence, severity and factors associated with urinary incontinence in a random sample of the elderly","volume":"8","author":"Yarnell","year":"1979","journal-title":"Age Ageing"},{"key":"mstaa5434bib010","doi-asserted-by":"publisher","author":"Abrams","year":"1997","DOI":"10.1007\/978-1-4471-3598-2","type":"book"},{"key":"mstaa5434bib011","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1002\/nau.10066","type":"journal-article","article-title":"Good urodynamic practices: uroflowmetry, filling cystometry, and pressure-flow studies","volume":"21","author":"Schafer","year":"2002","journal-title":"Neurourol. Urodyn."},{"key":"mstaa5434bib012","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1016\/S0022-5347(17)38887-0","type":"journal-article","article-title":"Ambulatory monitoring of bladder and detrusor pressure during natural filling","volume":"142","author":"Griffiths","year":"1989","journal-title":"J. Urol."},{"key":"mstaa5434bib013","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1111\/j.1464-410X.1991.tb15283.x","type":"journal-article","article-title":"Ambulatory monitoring and electronic measurement of urinary leakage in the diagnosis of detrusor instability and incontinence","volume":"68","author":"Webb","year":"1991","journal-title":"Br. J. Urol."},{"key":"mstaa5434bib014","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1002\/nau.10062","type":"journal-article","article-title":"Urodynamic changes induced by the intravaginal electrode during pelvic floor electrical stimulation","volume":"22","author":"Resplande","year":"2003","journal-title":"Neurourol. Urodyn."},{"key":"mstaa5434bib015","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/S0022-5347(17)65493-4","type":"journal-article","article-title":"Further observations on the kinetics of the urethrovesical sphincter","volume":"84","author":"Lapides","year":"1960","journal-title":"J. Urol."},{"key":"mstaa5434bib016","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1111\/j.1464-410X.1969.tb09925.x","type":"journal-article","article-title":"The urethral pressure profile","volume":"41","author":"Brown","year":"1969","journal-title":"Br. J. Urol."},{"key":"mstaa5434bib017","article-title":"Urethral profile measurement with modified enhorning catheter","author":"Jonas","year":"1975","type":"other"},{"key":"mstaa5434bib018","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1002\/nau.20991","type":"journal-article","article-title":"Comparison of air-charged and water-filled urodynamic pressure measurement catheters","volume":"30","author":"Cooper","year":"2011","journal-title":"Neurourol. Urodyn."},{"key":"mstaa5434bib019","article-title":"Luna micro-tip catheters for urology measurement","type":"web-resource"},{"key":"mstaa5434bib020","doi-asserted-by":"publisher","first-page":"1840","DOI":"10.1109\/JMEMS.2015.2444992","type":"journal-article","article-title":"Flexible distributed pressure sensing strip for a urethral catheter","volume":"24","author":"Ahmadi","year":"2015","journal-title":"J. Microelectromech. Syst."},{"key":"mstaa5434bib021","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/26\/7\/075101","type":"journal-article","article-title":"Research on a novel magnetic fluid micro-pressure sensor","volume":"26","author":"Yao","year":"2015","journal-title":"Meas. Sci. Technol."},{"key":"mstaa5434bib022","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/26\/6\/065101","type":"journal-article","article-title":"A high performance micro-pressure sensor based on a double-ended quartz tuning fork and silicon diaphragm in atmospheric packaging","volume":"26","author":"Cheng","year":"2015","journal-title":"Meas. Sci. Technol."},{"key":"mstaa5434bib023","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/24\/5\/055304","type":"journal-article","article-title":"Differential pressure distribution measurement for the development of insect-sized wings","volume":"24","author":"Takahashi","year":"2013","journal-title":"Meas. Sci. Technol."},{"key":"mstaa5434bib024","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1007\/BF00257163","type":"journal-article","article-title":"REVIEW: the urethral pressure profile, St. Peter\u2019s Hospitals and Institute of Urology, London","volume":"4","author":"Harrison","year":"1976","journal-title":"Urol. Res."}],"container-title":["Measurement Science and Technology"],"original-title":[],"link":[{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0957-0233\/28\/i=3\/a=035702\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0957-0233\/28\/i=3\/a=035702?key=crossref.6b6b075c819ff071f3f61e57234b08f8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/stacks.iop.org\/0957-0233\/28\/i=3\/a=035702?key=crossref.6b6b075c819ff071f3f61e57234b08f8","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0957-0233\/28\/i=3\/a=035702\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T13:18:26Z","timestamp":1783171106000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/aa5434"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,13]]},"references-count":24,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2017,1,13]]},"published-print":{"date-parts":[[2017,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6501\/aa5434","relation":{},"ISSN":["0957-0233","1361-6501"],"issn-type":[{"value":"0957-0233","type":"print"},{"value":"1361-6501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1,13]]},"assertion":[{"value":"Instrumented urethral catheter and its\n                      ex vivo\n                      validation in a sheep urethra","name":"article_title","label":"Article Title"},{"value":"Measurement Science and Technology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2017 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2016-08-15","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2016-12-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2017-01-13","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}