{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T11:27:20Z","timestamp":1786534040325,"version":"build-2736575974"},"reference-count":27,"publisher":"IOP Publishing","issue":"32","license":[{"start":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T00:00:00Z","timestamp":1786492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T00:00:00Z","timestamp":1786492800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000062","name":"National Institute of Diabetes and Digestive and Kidney Diseases","doi-asserted-by":"crossref","award":["NIH-RC2-DK-122379"],"award-info":[{"award-number":["NIH-RC2-DK-122379"]}],"id":[{"id":"10.13039\/100000062","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Meas. Sci. Technol."],"published-print":{"date-parts":[[2026,8,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Many experimental and clinical measurements require simultaneous acquisition from independent instruments that do not share a clock. We describe a device that enables such pairings via event-based synchronization: an electrical trigger from one instrument drives an Arduino-controlled stepper actuator that produces a brief mechanical event at a location sensed by the other instrument, leaving a fiducial marker for post-hoc temporal alignment. The motivating application is synchronization of high-resolution manometry (HRM) with transperineal ultrasound for phenotyping stress urinary incontinence. Bench characterization yielded a device latency of\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:mn>802.5<\/mml:mn>\n                          <\/mml:mrow>\n                          <mml:mstyle scriptlevel=\"0\"\/>\n                          <mml:mtext>\u03bc<\/mml:mtext>\n                          <mml:mtext>m<\/mml:mtext>\n                          <mml:mo>\u00b1<\/mml:mo>\n                          <mml:mrow>\n                            <mml:mn>46.2<\/mml:mn>\n                          <\/mml:mrow>\n                          <mml:mstyle scriptlevel=\"0\"\/>\n                          <mml:mtext>\u03bc<\/mml:mtext>\n                          <mml:mtext>m<\/mml:mtext>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    (mean\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    SD,\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>n<\/mml:mi>\n                          <mml:mo>=<\/mml:mo>\n                          <mml:mn>30<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ), of which the electromechanical response of the actuator accounts for\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u2248<\/mml:mo>\n                          <mml:mstyle scriptlevel=\"0\"\/>\n                          <mml:mrow>\n                            <mml:mn>84<\/mml:mn>\n                          <\/mml:mrow>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    of the mean latency and the dominant share of the trial-to-trial variation (i.e. the SD of\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:mn>46.2<\/mml:mn>\n                          <\/mml:mrow>\n                          <mml:mtext>\u03bc<\/mml:mtext>\n                          <mml:mtext>m<\/mml:mtext>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ). For the ultrasound\u2013HRM application, the synchronization uncertainty is\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u2248<\/mml:mo>\n                          <mml:mstyle scriptlevel=\"0\"\/>\n                          <mml:mrow>\n                            <mml:mn>6<\/mml:mn>\n                          <\/mml:mrow>\n                          <mml:mstyle scriptlevel=\"0\"\/>\n                          <mml:mtext>ms<\/mml:mtext>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>n<\/mml:mi>\n                          <mml:mo>=<\/mml:mo>\n                          <mml:mn>30<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    markers), set by the HRM rather than the device, whose intrinsic jitter contributes negligibly. The approach generalizes to instrument pairings in which one instrument provides a stable electrical trigger with a known relation to its recording timeline and the other is a mechanically-sensitive receiver of adequate bandwidth, provided the marker does not contaminate the signal of interest.\n                  <\/jats:p>","DOI":"10.1088\/1361-6501\/ae92a4","type":"journal-article","created":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T22:49:12Z","timestamp":1785451752000},"page":"325903","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Mechanically-induced fiducial marker system for event-based synchronization of independent recording instruments"],"prefix":"10.1088","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5254-6705","authenticated-orcid":true,"given":"Kourosh","family":"Kalayeh","sequence":"first","affiliation":[{"name":"University of Michigan"},{"name":"University of Michigan"},{"name":"Department of Biomedical Engineering, University of Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1012-7713","authenticated-orcid":true,"given":"John O L","family":"DeLancey","sequence":"additional","affiliation":[{"name":"University of Michigan"},{"name":"University of Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1528-2787","authenticated-orcid":false,"given":"James A","family":"Ashton-Miller","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Michigan"},{"name":"Department of Mechanical Engineering, University of Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4536-3919","authenticated-orcid":false,"given":"J Brian","family":"Fowlkes","sequence":"additional","affiliation":[{"name":"University of Michigan"},{"name":"Department of Biomedical Engineering, University of Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,8,12]]},"reference":[{"key":"mstae92a4bib1","doi-asserted-by":"publisher","first-page":"43","DOI":"10.3389\/fneng.2014.00043","type":"journal-article","article-title":"A low-cost programmable pulse generator for physiology and behavior","volume":"7","author":"Sanders","year":"2014","journal-title":"Front. Neuroeng."},{"key":"mstae92a4bib2","doi-asserted-by":"publisher","first-page":"IMAG.a.136","DOI":"10.1162\/IMAG.a.136","type":"journal-article","article-title":"The lab streaming layer for synchronized multimodal recording","volume":"3","author":"Kothe","year":"2025","journal-title":"Imaging Neurosci. (Camb)"},{"key":"mstae92a4bib3","first-page":"pp 135","type":"book","article-title":"Automatic event-based synchronization of multimodal data streams from wearable and ambient sensors","author":"Bannach","year":"2009"},{"key":"mstae92a4bib4","author":"Wang","year":"2019","type":"book"},{"key":"mstae92a4bib5","author":"K\u00fcgler","year":"2026","type":"book"},{"key":"mstae92a4bib6","first-page":"pp 4210","type":"conference-proceedings","article-title":"An automatic foot and shank IMU synchronization algorithm: proof-of-concept","author":"Shabani","year":"2022"},{"key":"mstae92a4bib7","doi-asserted-by":"publisher","first-page":"4900","DOI":"10.3390\/s23104900","type":"journal-article","article-title":"Monitoring knee contact force with force-sensing insoles","volume":"23","author":"Spencer","year":"2023","journal-title":"Sensors"},{"key":"mstae92a4bib8","first-page":"pp 113","type":"conference-proceedings","article-title":"Multi-sensor data-driven. synchronization using wearable sensors","author":"Bennett","year":"2015"},{"key":"mstae92a4bib9","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.1016\/j.eururo.2009.06.011","type":"journal-article","article-title":"Mechanisms of pelvic floor muscle function and the effect on the urethra during a cough","volume":"57","author":"Lovegrove Jones","year":"2010","journal-title":"Eur. Urol."},{"key":"mstae92a4bib10","doi-asserted-by":"publisher","first-page":"S159","DOI":"10.1016\/j.ejogrb.2009.02.021","type":"journal-article","article-title":"Dynamics of female pelvic floor function using urodynamics, ultrasound and Magnetic Resonance Imaging (MRI)","volume":"144","author":"Constantinou","year":"2009","journal-title":"Eur. J. Obstet. Gynecol. Reprod. Biol."},{"key":"mstae92a4bib11","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1016\/j.ultrasmedbio.2006.08.020","type":"journal-article","article-title":"Ultrasound evaluation of dynamic responses of female pelvic floor muscles","volume":"33","author":"Peng","year":"2007","journal-title":"Ultrasound Med. Biol."},{"key":"mstae92a4bib12","doi-asserted-by":"publisher","first-page":"S23","DOI":"10.1053\/j.gastro.2003.10.080","type":"journal-article","article-title":"Pathophysiology of adult urinary incontinence","volume":"126","author":"Delancey","year":"2004","journal-title":"Gastroenterology"},{"key":"mstae92a4bib13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/003655901750174773","type":"journal-article","article-title":"The functional anatomy of the female pelvic floor and stress continence control system","volume":"35","author":"Ashton-Miller","year":"2001","journal-title":"Scand. J. Urol. Nephrol. Suppl."},{"key":"mstae92a4bib14","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1111\/j.1532-5415.1998.tb02721.x","type":"journal-article","article-title":"A pelvic muscle precontraction can reduce cough-related urine loss in selected women with mild SUI","volume":"46","author":"Miller","year":"1998","journal-title":"J. Am. Geriatr. Soc."},{"key":"mstae92a4bib15","doi-asserted-by":"publisher","first-page":"1213","DOI":"10.1002\/jum.16676","type":"journal-article","article-title":"A new automated ultrasound quantification of urethral mobility for stress urinary incontinence: a feasibility study","volume":"44","author":"Kalayeh","year":"2025","journal-title":"J. Ultrasound Med."},{"key":"mstae92a4bib16","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1002\/nau.70231","type":"journal-article","article-title":"Automated ultrasound-based analysis of urethral kinematics in stress urinary incontinence: a pilot study","volume":"45","author":"Kalayeh","year":"2026","journal-title":"Neurourol. Urodyn."},{"key":"mstae92a4bib17","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1097\/SPV.0000000000000135","type":"journal-article","article-title":"Measurement of dynamic urethral pressures with a high-resolution manometry system in continent and incontinent women","volume":"21","author":"Kirby","year":"2015","journal-title":"Female Pelvic Med. Reconstr. Surg."},{"key":"mstae92a4bib18","article-title":"ATmega328\/P AVR microcontroller datasheet. Microchip technology Inc. Chandler, AZ","author":"Microchip Technology Inc.","year":"2016","type":"other"},{"key":"mstae92a4bib19","article-title":"Proportional pinch valves: MPPV series manual. resolution air, Ltd. Cincinnati, OH, USA","author":"Resolution Air, Ltd.","year":"2026","type":"other"},{"key":"mstae92a4bib20","article-title":"Pololu DRV8434A stepper motor driver carrier, item #3764. Pololu corporation. Las Vegas, NV","author":"Corporation","year":"2026","type":"other"},{"key":"mstae92a4bib21","article-title":"SN74AHC123A dual retriggerable monostable multivibrators. Texas instruments incorporated. Dallas, TX","author":"Texas Instruments Incorporated","type":"other"},{"key":"mstae92a4bib22","article-title":"Pololu bidirectional logic level shifter, item #2595. Pololu corporation. Las Vegas, NV","author":"Pololu Corporation","year":"2026","type":"other"},{"key":"mstae92a4bib23","article-title":"FlexiForce standard force and load sensors datasheet, model A301. Tekscan Inc. Boston, MA","author":"Tekscan Inc.","year":"2024","type":"other"},{"key":"mstae92a4bib24","article-title":"Automated onset detection quantifies pelvic floor muscle coordination in transperineal ultrasound: a proof-of-concept study. San Juan, PR","author":"Kalayeh","year":"2026","type":"other"},{"key":"mstae92a4bib25","article-title":"Quantifying pelvic floor coordination via automated motion onset detection in transperineal ultrasound. Philadelphia, PA","author":"Kalayeh","year":"2026","type":"other"},{"key":"mstae92a4bib26","article-title":"SUI phenotyping with high resolution manometry and transperineal ultrasound. Vancouver, Canada","author":"Kalayeh","year":"2025","type":"other"},{"key":"mstae92a4bib27","article-title":"Biomechanical analyses of female stress urinary incontinence","author":"Kim","year":"1994","type":"other"}],"container-title":["Measurement Science and Technology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T10:27:52Z","timestamp":1786530472000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6501\/ae92a4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,12]]},"references-count":27,"journal-issue":{"issue":"32","published-online":{"date-parts":[[2026,8,12]]},"published-print":{"date-parts":[[2026,8,14]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6501\/ae92a4","relation":{},"ISSN":["0957-0233","1361-6501"],"issn-type":[{"value":"0957-0233","type":"print"},{"value":"1361-6501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,12]]},"assertion":[{"value":"Mechanically-induced fiducial marker system for event-based synchronization of independent recording instruments","name":"article_title","label":"Article Title"},{"value":"Measurement Science and Technology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-17","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-30","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-08-12","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}