{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T22:53:48Z","timestamp":1777589628615,"version":"3.51.4"},"reference-count":67,"publisher":"IOP Publishing","issue":"14","license":[{"start":{"date-parts":[[2019,2,7]],"date-time":"2019-02-07T00:00:00Z","timestamp":1549497600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2019,2,7]],"date-time":"2019-02-07T00:00:00Z","timestamp":1549497600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Department of Science and Technology, Ministry of Science and Technology","award":["SR\/FST\/ETII-028\/2010"],"award-info":[{"award-number":["SR\/FST\/ETII-028\/2010"]}]},{"DOI":"10.13039\/501100008628","name":"Ministry of Electronics and Information technology","doi-asserted-by":"crossref","award":["5(9)\/2012-NANO"],"award-info":[{"award-number":["5(9)\/2012-NANO"]}],"id":[{"id":"10.13039\/501100008628","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Nanotechnology"],"published-print":{"date-parts":[[2019,4,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    A back-gate-field-effect-transistor (BG-FET) has been developed to selectively detect ammonia and urea. The BG-FET was prepared on a p-type Si substrate with an n-type channel of CdS-TiO\n                    <jats:sub>2<\/jats:sub>\n                    nanocomposite and poly-methyl methacrylate film as dielectric layer. The reusability of the sensor was ensured by putting it as a cover to a chamber where samples were detected. The BG-FET showed an increase in drain current with the increase in ammonia release from chamber because higher numbers of charge carriers were created when ammonia adsorped on CdS-TiO\n                    <jats:sub>2<\/jats:sub>\n                    nanostructures. Control experiments suggested that the variation in current-to-voltage response of BG-FET could also be calibrated to measure the activity of a host of other hazardous gases. The lowest concentration of ammonia detected was \u223c0.85 ppm with a response time of 30 s at a gate voltage of 0.5 V or less, which were superior than available field effect transistors ammonia sensors. Addition of urease in urine liberated ammonia equivalent to urea content in urine, which could be detected by the proposed BGFET. The urea-urease enzyme catalysis reaction made the sensor specific in detecting the biomarker. The accuracy, sensitivity, and reusability of the device was found to be suitable to develop a point-of-care testing device for ammonia and urea detection.\n                  <\/jats:p>","DOI":"10.1088\/1361-6528\/aafe44","type":"journal-article","created":{"date-parts":[[2019,1,14]],"date-time":"2019-01-14T17:30:54Z","timestamp":1547487054000},"page":"145502","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":21,"title":["Reusable nano-BG-FET for point-of-care estimation of ammonia and urea in human urine"],"prefix":"10.1088","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1861-6295","authenticated-orcid":false,"given":"Sagnik","family":"Middya","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitradip","family":"Bhattacharjee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dipankar","family":"Bandyopadhyay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2019,2,7]]},"reference":[{"key":"nanoaafe44bib1","first-page":"155","type":"journal-article","article-title":"Existing and emerging technologies for point-of-care testing","volume":"35","author":"St John","year":"2014","journal-title":"Clin. Biochem. Rev."},{"key":"nanoaafe44bib2","doi-asserted-by":"publisher","first-page":"868","DOI":"10.1345\/aph.1D347","type":"journal-article","article-title":"Home blood pressure monitoring: point-of-care testing","volume":"38","author":"Lopez","year":"2004","journal-title":"Ann. Pharmacother."},{"key":"nanoaafe44bib3","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.bios.2015.11.075","type":"journal-article","article-title":"Paper-based a-amylase detector for point-of-care diagnostics","volume":"78","author":"Dutta","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"nanoaafe44bib4","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1016\/j.bios.2017.03.049","type":"journal-article","article-title":"Nano-enabled paper humidity sensor for mobile based point-of-care lung function monitoring","volume":"94","author":"Bhattacharjee","year":"2017","journal-title":"Biosens. Bioelectron."},{"key":"nanoaafe44bib5","doi-asserted-by":"publisher","first-page":"738","DOI":"10.1016\/j.snb.2016.12.058","type":"journal-article","article-title":"Instrument-free point-of-care molecular diagnosis of H1N1 based on microfluidic convective PCR","volume":"243","author":"Qiu","year":"2017","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib6","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1177\/1932296814522799","type":"journal-article","article-title":"Nanomaterial-mediated biosensors for monitoring glucose","volume":"8","author":"Taguchi","year":"2014","journal-title":"J. Diabetes Sci. Technol."},{"key":"nanoaafe44bib7","author":"Vanjari","year":"2012","type":"patent"},{"key":"nanoaafe44bib8","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1109\/JSEN.2017.2777913","type":"journal-article","article-title":"Creatinine-iron complex and its use in electrochemical measurement of urine creatinine","volume":"18","author":"Kumar","year":"2018","journal-title":"IEEE Sens. J."},{"key":"nanoaafe44bib9","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1289\/ehp.7651","type":"journal-article","article-title":"Personalized exposure assessment: promising approaches for human environmental health research","volume":"113","author":"Weis","year":"2005","journal-title":"Environ. Health Perspect."},{"key":"nanoaafe44bib10","doi-asserted-by":"publisher","first-page":"3700207","DOI":"10.1109\/JTEHM.2013.2281819","type":"journal-article","article-title":"Rapid, affordable, and point-of-care water monitoring via a microfluidic DNA sensor and a mobile interface for global health","volume":"1","author":"Kim","year":"2013","journal-title":"IEEE Transl. Eng. Health Med."},{"key":"nanoaafe44bib11","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1080\/10934528509375217","type":"journal-article","article-title":"Review of toxicity of gases emitted from combustion, pyrolysis of municipal and industrial wastes","volume":"20","author":"Wilkins","year":"1985","journal-title":"J. Environ. Sci. Health A"},{"key":"nanoaafe44bib12","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1289\/ehp.99107617","type":"journal-article","article-title":"Emergency planning and the acute toxic potency of inhaled ammonia","volume":"107","author":"Michaels","year":"1999","journal-title":"Environ. Health Perspect."},{"key":"nanoaafe44bib13","doi-asserted-by":"publisher","first-page":"831","DOI":"10.1016\/j.envint.2006.05.002","type":"journal-article","article-title":"Ecological and toxicological effects of inorganic nitrogen pollution in aquatic ecosystems: a global assessment","volume":"32","author":"Camargo","year":"2006","journal-title":"Environ. Int."},{"key":"nanoaafe44bib14","doi-asserted-by":"publisher","first-page":"286","DOI":"10.3168\/jds.S0022-0302(68)86976-0","type":"journal-article","article-title":"Some aspects of ammonia toxicity in animal cells","volume":"51","author":"Visek","year":"1968","journal-title":"J. Dairy Sci."},{"key":"nanoaafe44bib15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/BF02833598","type":"journal-article","article-title":"Ammonia: key factor in the pathogenesis of hepatic encephalopathy","volume":"6","author":"Butterworth","year":"1987","journal-title":"Neurochem. Pathol."},{"key":"nanoaafe44bib16","doi-asserted-by":"publisher","first-page":"2223","DOI":"10.1046\/j.1523-1755.2002.00683.x","type":"journal-article","article-title":"Significance of the fractional excretion of urea in the differential diagnosis of acute renal failure","volume":"62","author":"Carvounis","year":"2002","journal-title":"Kidney Int."},{"key":"nanoaafe44bib17","doi-asserted-by":"publisher","first-page":"47","DOI":"10.7326\/0003-4819-89-1-47","type":"journal-article","article-title":"Urinary diagnostic indices in acute renal failure: a prospective study","volume":"89","author":"Miller","year":"1978","journal-title":"Ann. Intern. Med."},{"key":"nanoaafe44bib18","author":"Nelson","year":"2013","edition":"6th edn","type":"book"},{"key":"nanoaafe44bib19","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1007\/s00467-011-1838-5","type":"journal-article","article-title":"Hyperammonemia in review: pathophysiology, diagnosis, and treatment","volume":"27","author":"Auron","year":"2012","journal-title":"Pediatr. Nephrol."},{"key":"nanoaafe44bib20","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.nut.2014.03.016","type":"journal-article","article-title":"Ammonia and amino acid profiles in liver cirrhosis: effects of variables leading to hepatic encephalopathy","volume":"31","author":"Holecek","year":"2015","journal-title":"Nutrition"},{"key":"nanoaafe44bib21","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/S0002-9343(02)01477-8","type":"journal-article","article-title":"Correlation between ammonia levels and the severity of hepatic encephalopathy","volume":"114","author":"Ong","year":"2003","journal-title":"Am. J. Med."},{"key":"nanoaafe44bib22","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1038\/ki.1997.324","type":"journal-article","article-title":"Quantitative analysis of ammonia on the breath of patients in end-stage renal failure","volume":"52","author":"Davies","year":"1997","journal-title":"Kidney Int."},{"key":"nanoaafe44bib23","doi-asserted-by":"publisher","first-page":"57006","DOI":"10.1117\/1.JBO.20.5.057006","type":"journal-article","article-title":"Ammonia and ethylene biomarkers in the respiration of the people with schizophrenia using photoacoustic spectroscopy","volume":"20","author":"Popa","year":"2015","journal-title":"J. Biomed. Opt."},{"key":"nanoaafe44bib24","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1186\/1471-230X-9-21","type":"journal-article","article-title":"Blood ammonia levels in liver cirrhosis: a clue for the presence of portosystemic collateral veins","volume":"9","author":"Tarantino","year":"2009","journal-title":"BMC Gastroenterol."},{"key":"nanoaafe44bib25","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1136\/pgmj.55.639.10","type":"journal-article","article-title":"The cause of the raised plasma urea of acute heart failure","volume":"55","author":"Thomas","year":"1979","journal-title":"Postgrad. Med. J."},{"key":"nanoaafe44bib26","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1016\/j.snb.2016.01.086","type":"journal-article","article-title":"Highly sensitive and flexible ammonia sensor based on S and N co-doped graphene quantum dots\/polyaniline hybrid at room temperature","volume":"229","author":"Gavgani","year":"2016","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib27","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.snb.2016.08.173","type":"journal-article","article-title":"Flexible room temperature ammonia sensor based on polyaniline","volume":"240","author":"Kumar","year":"2017","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib28","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.apsusc.2015.02.164","type":"journal-article","article-title":"Room temperature ammonia sensor based on copper nanoparticle intercalated polyaniline nanocomposite thin films","volume":"339","author":"Patil","year":"2015","journal-title":"Appl. Surf. Sci."},{"key":"nanoaafe44bib29","doi-asserted-by":"publisher","first-page":"26415","DOI":"10.3390\/s151026415","type":"journal-article","article-title":"Ammonia gas sensing behavior of tanninsulfonic acid doped polyaniline-TiO2 composite","volume":"15","author":"Bairi","year":"2015","journal-title":"Sensors"},{"key":"nanoaafe44bib30","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.nancom.2010.09.005","type":"journal-article","article-title":"High sensitivity of a ZnO nanowire-based ammonia gas sensor with Pt nano-particles","volume":"1","author":"Chang","year":"2010","journal-title":"Nano Commun. Netw."},{"key":"nanoaafe44bib31","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.talanta.2011.12.006","type":"journal-article","article-title":"Ultra-high sensitive ammonia chemical sensor based on ZnO nanopencils","volume":"89","author":"Dar","year":"2012","journal-title":"Talanta"},{"key":"nanoaafe44bib32","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1016\/j.matchar.2006.11.007","type":"journal-article","article-title":"TiO2 thin film gas sensor for monitoring ammonia","volume":"58","author":"Karunagaran","year":"2007","journal-title":"Mater. Charact."},{"key":"nanoaafe44bib33","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1016\/j.snb.2004.11.054","type":"journal-article","article-title":"Ammonia sensors and their applications\u2014a review","volume":"107","author":"Timmer","year":"2005","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib34","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.snb.2010.11.057","type":"journal-article","article-title":"Room temperature ammonia sensors based on zinc oxide and functionalized graphite and multi-walled carbon nanotubes","volume":"152","author":"Tulliani","year":"2011","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib35","doi-asserted-by":"publisher","first-page":"1784","DOI":"10.1016\/j.materresbull.2013.01.037","type":"journal-article","article-title":"Sensing behavior of CdS nanoparticles to SO2, H2S and NH3 at room temperature","volume":"48","author":"Fu","year":"2013","journal-title":"Mater. Res. Bull."},{"key":"nanoaafe44bib36","doi-asserted-by":"publisher","first-page":"1432","DOI":"10.1002\/elan.200904584","type":"journal-article","article-title":"Ammonia gas sensor using polypyrrole-coated TiO2\/ZnO nanofibers","volume":"21","author":"Wang","year":"2009","journal-title":"Electroanalysis"},{"key":"nanoaafe44bib37","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1016\/j.snb.2015.03.103","type":"journal-article","article-title":"Detection of ammonia in human breath using quartz crystal microbalance sensors with functionalized mesoporous SiO2 nanoparticle films","volume":"215","author":"Ogimoto","year":"2015","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib38","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1021\/ac60241a037","type":"journal-article","article-title":"Determination of dissolved ammonia by gas chromatography","volume":"38","author":"Jenkins","year":"1966","journal-title":"Anal. Chem."},{"key":"nanoaafe44bib39","doi-asserted-by":"publisher","first-page":"2881","DOI":"10.1039\/C5NR06066D","type":"journal-article","article-title":"Simultaneous determination of indoor ammonia pollution and its biological metabolite in the human body with a recyclable nanocrystalline lanthanide-functionalized MOF","volume":"8","author":"Hao","year":"2016","journal-title":"Nanoscale"},{"key":"nanoaafe44bib40","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1016\/j.snb.2016.01.058","type":"journal-article","article-title":"A long period grating optical fiber sensor with nano-assembled porphyrin layers for detecting ammonia gas","volume":"228","author":"Wang","year":"2016","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib41","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1039\/b716154a","type":"journal-article","article-title":"An aqueous ammonia sensor based on an inkjet-printed polyaniline nanoparticle-modified electrode","volume":"133","author":"Crowley","year":"2008","journal-title":"Analyst"},{"key":"nanoaafe44bib42","doi-asserted-by":"publisher","first-page":"2189","DOI":"10.1021\/am5084122","type":"journal-article","article-title":"Graphene on paper: a simple, low-cost chemical sensing platform","volume":"7","author":"Kumar","year":"2015","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"nanoaafe44bib43","doi-asserted-by":"publisher","first-page":"4329","DOI":"10.1002\/adfm.201505477","type":"journal-article","article-title":"Flexible transparent reduced graphene oxide sensor coupled with organic dye molecules for rapid dual-mode ammonia gas detection","volume":"26","author":"Duy","year":"2016","journal-title":"Adv. Funct. Mater."},{"key":"nanoaafe44bib44","author":"Bhat","year":"2012","type":"patent"},{"key":"nanoaafe44bib45","doi-asserted-by":"publisher","first-page":"17406","DOI":"10.3390\/s140917406","type":"journal-article","article-title":"Gas sensors based on semiconducting nanowire field-effect transistors","volume":"14","author":"Feng","year":"2014","journal-title":"Sensors"},{"key":"nanoaafe44bib46","doi-asserted-by":"publisher","first-page":"20","DOI":"10.3390\/chemosensors4040020","type":"journal-article","article-title":"Recent trends in field-effect transistors-based immunosensors","volume":"4","author":"de Moraes","year":"2016","journal-title":"Chemosensors"},{"key":"nanoaafe44bib47","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1016\/S0925-4005(00)00541-4","type":"journal-article","article-title":"Multi-parameter gas sensors based on organic thin-film-transistors","volume":"67","author":"Torsi","year":"2000","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib48","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.snb.2013.12.118","type":"journal-article","article-title":"Ammonia gas sensing using a graphene field-effect transistor gated by ionic liquid","volume":"195","author":"Inaba","year":"2014","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib49","doi-asserted-by":"publisher","first-page":"213","DOI":"10.3390\/s17010213","type":"journal-article","article-title":"Gas sensors based on polymer field-effect transistors","volume":"17","author":"Lv","year":"2017","journal-title":"Sensors"},{"key":"nanoaafe44bib50","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.snb.2015.11.005","type":"journal-article","article-title":"Poly(3-hexylthiophene)\/polystyrene (P3HT\/PS) blends based organic field-effect transistor ammonia gas sensor","volume":"225","author":"Han","year":"2016","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib51","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/srep20671","type":"journal-article","article-title":"Unencapsulated air-stable organic field effect transistor by all solution processes for low power vapor sensing","volume":"6","author":"Feng","year":"2016","journal-title":"Sci. Rep."},{"key":"nanoaafe44bib52","doi-asserted-by":"publisher","first-page":"3635","DOI":"10.1021\/acsami.5b08078","type":"journal-article","article-title":"Highly sensitive thin-film field-effect transistor sensor for ammonia with the DPP-bithiophene conjugated polymer entailing thermally cleavable tert-butoxy groups in the side chains","volume":"8","author":"Yang","year":"2016","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"nanoaafe44bib53","doi-asserted-by":"publisher","first-page":"54836","DOI":"10.1039\/C6RA09731F","type":"journal-article","article-title":"Ammonium ion detection in solution using vertically grown ZnO nanorod based field-effect transistor","volume":"6","author":"Ahmad","year":"2016","journal-title":"RSC Adv."},{"key":"nanoaafe44bib54","doi-asserted-by":"publisher","first-page":"6570","DOI":"10.1021\/acsami.6b00471","type":"journal-article","article-title":"Morphology-driven high-performance polymer transistor-based ammonia gas sensor","volume":"8","author":"Yu","year":"2016","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"nanoaafe44bib55","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.snb.2014.06.083","type":"journal-article","article-title":"Performance improvement of organic field-effect transistor ammonia gas sensor using ZnO\/PMMA hybrid as dielectric layer","volume":"203","author":"Han","year":"2014","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib56","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/S0925-4005(03)00075-3","type":"journal-article","article-title":"Biosensors for clinical diagnostics industry","volume":"91","author":"Malhotra","year":"2003","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib57","doi-asserted-by":"publisher","first-page":"9635","DOI":"10.3390\/s120709635","type":"journal-article","article-title":"A survey on gas sensing technology","volume":"12","author":"Liu","year":"2012","journal-title":"Sensors"},{"key":"nanoaafe44bib58","doi-asserted-by":"publisher","first-page":"1613","DOI":"10.1063\/1.1559438","type":"journal-article","article-title":"In2O3 nanowires as chemical sensors","volume":"82","author":"Li","year":"2003","journal-title":"Appl. Phys. Lett."},{"key":"nanoaafe44bib59","doi-asserted-by":"publisher","DOI":"10.1063\/1.2358214","type":"journal-article","article-title":"Large area, dense silicon nanowire array chemical sensors","volume":"89","author":"Talin","year":"2006","journal-title":"Appl. Phys. Lett."},{"key":"nanoaafe44bib60","doi-asserted-by":"publisher","first-page":"3221","DOI":"10.1016\/j.orgel.2014.08.023","type":"journal-article","article-title":"Printable ammonia sensor based on organic field effect transistor","volume":"15","author":"Besar","year":"2014","journal-title":"Org. Electron."},{"key":"nanoaafe44bib61","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1016\/j.snb.2012.06.010","type":"journal-article","article-title":"Poly-3-hexylthiophene based organic field-effect transistor: detection of low concentration of ammonia","volume":"171","author":"Tiwari","year":"2012","journal-title":"Sensors Actuators B"},{"key":"nanoaafe44bib62","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1109\/JSEN.2011.2121901","type":"journal-article","article-title":"Pentacene-based organic thin film transistors for ammonia sensing","volume":"12","author":"Zan","year":"2012","journal-title":"IEEE Sens. J."},{"key":"nanoaafe44bib63","doi-asserted-by":"publisher","author":"Coronado","year":"2013","DOI":"10.1007\/978-1-4471-5061-9","type":"book"},{"key":"nanoaafe44bib64","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.matchemphys.2005.04.028","type":"journal-article","article-title":"The effect of substrate temperature on the structural and some physical properties of ultrasonically sprayed CdS films","volume":"94","author":"Bilgin","year":"2005","journal-title":"Mater. Chem. Phys."},{"key":"nanoaafe44bib65","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.orgel.2015.04.001","type":"journal-article","article-title":"High-performance diketopyrrolopyrrole-based organic field-effect transistors for flexible gas sensors","volume":"23","author":"Ryu","year":"2015","journal-title":"Org. Electron."},{"key":"nanoaafe44bib66","doi-asserted-by":"publisher","first-page":"6509","DOI":"10.3390\/s110706509","type":"journal-article","article-title":"A single polyaniline nanofiber field effect transistor and its gas sensing mechanisms","volume":"11","author":"Chen","year":"2011","journal-title":"Sensors"},{"key":"nanoaafe44bib67","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.snb.2015.11.005","type":"journal-article","article-title":"Poly(3-hexylthiophene)\/polystyrene (P3HT\/PS) blends based organic field-effect transistor ammonia gas sensor","volume":"225","author":"Han","year":"2016","journal-title":"Sensors Actuators B"}],"container-title":["Nanotechnology"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0957-4484\/30\/i=14\/a=145502?key=crossref.ec24197d5dd16da97a714219f344e780","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0957-4484\/30\/i=14\/a=145502\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0957-4484\/30\/i=14\/a=145502\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0957-4484\/30\/i=14\/a=145502?key=crossref.ec24197d5dd16da97a714219f344e780","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T14:03:57Z","timestamp":1772287437000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6528\/aafe44"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,7]]},"references-count":67,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2019,2,7]]},"published-print":{"date-parts":[[2019,4,5]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6528\/aafe44","relation":{},"ISSN":["0957-4484","1361-6528"],"issn-type":[{"value":"0957-4484","type":"print"},{"value":"1361-6528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,7]]},"assertion":[{"value":"Reusable nano-BG-FET for point-of-care estimation of ammonia and urea in human urine","name":"article_title","label":"Article Title"},{"value":"Nanotechnology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2019 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2018-12-14","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-01-14","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-02-07","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}