{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T14:46:40Z","timestamp":1782571600762,"version":"3.54.5"},"reference-count":32,"publisher":"IOP Publishing","issue":"9","license":[{"start":{"date-parts":[[2017,4,6]],"date-time":"2017-04-06T00:00:00Z","timestamp":1491436800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2017,4,6]],"date-time":"2017-04-06T00:00:00Z","timestamp":1491436800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"National R&D Program for Cancer Control, Ministry of Health & Welfare, Republic of Korea","award":["1631200"],"award-info":[{"award-number":["1631200"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2017,5,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>We propose bilateral total body irradiation (TBI) utilizing a 3D printer and a 3D optical scanner. We acquired surface information of an anthropomorphic phantom with the 3D scanner and fabricated the 3D compensator with the 3D printer, which could continuously compensate for the lateral missing tissue of an entire body from the beam\u2019s eye view. To test the system\u2019s performance, we measured doses with optically stimulated luminescent dosimeters (OSLDs) as well as EBT3 films with the anthropomorphic phantom during TBI without a compensator, conventional bilateral TBI, and TBI with the 3D compensator (3D TBI). The 3D TBI showed the most uniform dose delivery to the phantom. From the OSLD measurements of the 3D TBI, the deviations between the measured doses and the prescription dose ranged from\u2009\u2009\u22126.7% to 2.4% inside the phantom and from\u2009\u2009\u22122.3% to 0.6% on the phantom\u2019s surface. From the EBT3 film measurements, the prescription dose could be delivered to the entire body of the phantom within\u2009\u2009\u00b110% accuracy, except for the chest region, where tissue heterogeneity is extreme. The 3D TBI doses were much more uniform than those of the other irradiation techniques, especially in the anterior-to-posterior direction. The 3D TBI was advantageous, owing to its uniform dose delivery as well as its efficient treatment procedure.<\/jats:p>","DOI":"10.1088\/1361-6560\/aa6866","type":"journal-article","created":{"date-parts":[[2017,3,22]],"date-time":"2017-03-22T16:58:25Z","timestamp":1490201905000},"page":"3735-3756","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":12,"title":["Total body irradiation with a compensator fabricated using a 3D optical scanner and a 3D printer"],"prefix":"10.1088","volume":"62","author":[{"given":"So-Yeon","family":"Park","sequence":"first","affiliation":[{"name":"Seoul National University Hospital"},{"name":"Seoul National University Medical Research Center"},{"name":"Seoul National University Hospital"},{"name":"Advanced Institutes of Convergence Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jung-in","family":"Kim","sequence":"additional","affiliation":[{"name":"Seoul National University Hospital"},{"name":"Seoul National University Medical Research Center"},{"name":"Seoul National University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoon Ha","family":"Joo","sequence":"additional","affiliation":[{"name":"Seoul National University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jung Chan","family":"Lee","sequence":"additional","affiliation":[{"name":"Seoul National University College of Medicine"},{"name":"Seoul National University Hospital"},{"name":"Seoul National University Medical Research Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong Min","family":"Park","sequence":"additional","affiliation":[{"name":"Seoul National University Hospital"},{"name":"Seoul National University Medical Research Center"},{"name":"Seoul National University Hospital"},{"name":"Advanced Institutes of Convergence Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2017,4,6]]},"reference":[{"key":"pmbaa6866bib001","doi-asserted-by":"publisher","first-page":"270","DOI":"10.4236\/ijmpcero.2016.54027","type":"journal-article","article-title":"TBI technique improvements for anesthetized pediatric patients based on near-miss incident reporting","volume":"2016","author":"Cao","year":"2016","journal-title":"Int. J. Med. Phys. Clin. Eng. Radiat. Ocol."},{"key":"pmbaa6866bib002","type":"journal-article","article-title":"Total body irradiation with step translation and dynamic field matching","volume":"2013","author":"Chen","year":"2013","journal-title":"Biomed. Res. Int."},{"key":"pmbaa6866bib003","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1118\/1.598978","type":"journal-article","article-title":"A variable speed translating couch technique for total body irradiation","volume":"27","author":"Chretien","year":"2000","journal-title":"Med. Phys."},{"key":"pmbaa6866bib004","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0082496","type":"journal-article","article-title":"Enhanced responses to tumor immunization following total body irradiation are time-dependent","volume":"8","author":"Diab","year":"2013","journal-title":"PLoS One"},{"key":"pmbaa6866bib005","doi-asserted-by":"publisher","first-page":"1741","DOI":"10.1109\/TBME.2005.855715","type":"journal-article","article-title":"Implementation of a water compensator for total body irradiation","volume":"52","author":"Gallina","year":"2005","journal-title":"IEEE. Trans. Biol. Med. Eng."},{"key":"pmbaa6866bib006","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1088\/0031-9155\/39\/1\/002","type":"journal-article","article-title":"A translating-bed technique for total-body irradiation","volume":"39","author":"Gerig","year":"1994","journal-title":"Phys. Med. Biol."},{"key":"pmbaa6866bib007","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1259\/bjr.74.887.741041","type":"journal-article","article-title":"Total body irradiation using a modified standing technique: a single institution 7 years experience","volume":"74","author":"Harden","year":"2001","journal-title":"Br. J. Radiol."},{"key":"pmbaa6866bib008","doi-asserted-by":"publisher","first-page":"5263","DOI":"10.1118\/1.4739250","type":"journal-article","article-title":"Dosimetric aspects of inverse-planned modulated-arc total-body irradiation","volume":"39","author":"Held","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaa6866bib009","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1088\/0031-9155\/39\/5\/001","type":"journal-article","article-title":"Total-body irradiation on an isocentric linear accelerator: a radiation output compensation technique","volume":"39","author":"Hugtenburg","year":"1994","journal-title":"Phys. Med. Biol."},{"key":"pmbaa6866bib010","doi-asserted-by":"publisher","first-page":"3214","DOI":"10.1118\/1.2044428","type":"journal-article","article-title":"Feasibility study of helical tomotherapy for total body or total marrow irradiation","volume":"32","author":"Hui","year":"2005","journal-title":"Med. Phys."},{"key":"pmbaa6866bib011","doi-asserted-by":"publisher","first-page":"3767","DOI":"10.1120\/jacmp.v13i3.3767","type":"journal-article","article-title":"Total body irradiation dose optimization based on radiological depth","volume":"13","author":"Hussain","year":"2012","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaa6866bib012","doi-asserted-by":"publisher","first-page":"932","DOI":"10.1118\/1.3534196","type":"journal-article","article-title":"Aperture modulated, translating bed total body irradiation","volume":"38","author":"Hussain","year":"2011","journal-title":"Med. Phys."},{"key":"pmbaa6866bib013","doi-asserted-by":"publisher","first-page":"2761","DOI":"10.1118\/1.4705366","type":"journal-article","article-title":"Inverse-planned modulated-arc total-body irradiation","volume":"39","author":"Kirby","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaa6866bib014","doi-asserted-by":"publisher","first-page":"1663","DOI":"10.1118\/1.2899999","type":"journal-article","article-title":"Attenuator design for organs at risk in total body irradiation using a translation technique","volume":"35","author":"Lavallee","year":"2008","journal-title":"Med. Phys."},{"key":"pmbaa6866bib015","doi-asserted-by":"publisher","first-page":"3416","DOI":"10.1120\/jacmp.v12i3.3416","type":"journal-article","article-title":"3D heterogeneous dose distributions for total body irradiation patients","volume":"12","author":"Lavallee","year":"2011","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaa6866bib016","doi-asserted-by":"publisher","first-page":"6137","DOI":"10.1118\/1.4964452","type":"journal-article","article-title":"A depth-sensing technique on 3D-printed compensator for total body irradiation patient measurement and treatment planning","volume":"43","author":"Lee","year":"2016","journal-title":"Med. Phys."},{"key":"pmbaa6866bib017","doi-asserted-by":"publisher","first-page":"3852","DOI":"10.1120\/jacmp.v14i2.3852","type":"journal-article","article-title":"Feasibility study on dosimetry verification of volumetric-modulated arc therapy-based total marrow irradiation","volume":"14","author":"Liang","year":"2013","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaa6866bib018","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1186\/s13014-015-0391-y","type":"journal-article","article-title":"In vivo dosimetry with Gafchromic films for multi-isocentric VMAT irradiation of total marrow lymph-nodes: a feasibility study","volume":"10","author":"Mancosu","year":"2015","journal-title":"Radiat. Oncol."},{"key":"pmbaa6866bib019","doi-asserted-by":"publisher","first-page":"5568","DOI":"10.1118\/1.3495816","type":"journal-article","article-title":"Statistical analysis of dose heterogeneity in circulating blood: implications for sequential methods of total body irradiation","volume":"37","author":"Molloy","year":"2010","journal-title":"Med. Phys."},{"key":"pmbaa6866bib020","doi-asserted-by":"publisher","first-page":"1641","DOI":"10.1016\/j.ijrobp.2011.10.045","type":"journal-article","article-title":"Evaluation of field-in-field technique for total body irradiation","volume":"83","author":"Onal","year":"2012","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbaa6866bib021","doi-asserted-by":"publisher","first-page":"198","DOI":"10.3857\/roj.2014.32.3.198","type":"journal-article","article-title":"Effects of total body irradiation-based conditioning on allogeneic stem cell transplantation for pediatric acute leukemia: a single-institution study","volume":"32","author":"Park","year":"2014","journal-title":"Radiat. Oncol. J."},{"key":"pmbaa6866bib022","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1118\/1.595677","type":"journal-article","article-title":"Physical treatment planning of total-body irradiation: patient translation and beam-zone method","volume":"12","author":"Quast","year":"1985","journal-title":"Med. Phys."},{"key":"pmbaa6866bib023","first-page":"736","type":"journal-article","article-title":"Total body irradiation (T.B.I.). Preliminary results of a new technique in 30 patients with hematologic malignancy","volume":"155","author":"Richaud","year":"1979","journal-title":"Strahlenther. Onkol."},{"key":"pmbaa6866bib024","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/0360-3016(95)02078-0","type":"journal-article","article-title":"Effect of radiation dose rate and cyclophosphamide on pulmonary toxicity after total body irradiation in a mouse model","volume":"34","author":"Safwat","year":"1996","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbaa6866bib025","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1120\/1.1411962","type":"journal-article","article-title":"A translational couch technique for total body irradiation","volume":"2","author":"Sarfaraz","year":"2001","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaa6866bib026","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1016\/S0360-3016(97)00913-9","type":"journal-article","article-title":"Dose rate-dependent sparing of the gastrointestinal tract by fractionated total body irradiation in dogs given marrow autografts","volume":"40","author":"Storb","year":"1998","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbaa6866bib027","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.ijrobp.2014.09.014","type":"journal-article","article-title":"Multi-institutional feasibility study of a fast patient localization method in total marrow irradiation with helical tomotherapy: a global health initiative by the international consortium of total marrow irradiation","volume":"91","author":"Takahashi","year":"2015","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbaa6866bib028","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/S0167-8140(85)80122-5","type":"journal-article","article-title":"Effect of dose-rate on total body irradiation: lethality and pathologic findings","volume":"4","author":"Travis","year":"1985","journal-title":"Radiother. Oncol."},{"key":"pmbaa6866bib029","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/0167-8140(95)01697-X","type":"journal-article","article-title":"Total body irradiation with translation method","volume":"38","author":"Umek","year":"1996","journal-title":"Radiother. Oncol."},{"key":"pmbaa6866bib030","doi-asserted-by":"publisher","first-page":"5609","DOI":"10.1118\/1.2990779","type":"journal-article","article-title":"Feasibility study for linac-based intensity modulated total marrow irradiation","volume":"35","author":"Wilkie","year":"2008","journal-title":"Med. Phys."},{"key":"pmbaa6866bib031","doi-asserted-by":"publisher","first-page":"2239","DOI":"10.1118\/1.3697526","type":"journal-article","article-title":"A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity","volume":"39","author":"Yao","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaa6866bib032","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1016\/j.ijrobp.2010.06.029","type":"journal-article","article-title":"Linear accelerator-based intensity-modulated total marrow irradiation technique for treatment of hematologic malignancies: a dosimetric feasibility study","volume":"79","author":"Yeginer","year":"2011","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/62\/i=9\/a=3735\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/62\/i=9\/a=3735?key=crossref.c041469532124b680e716b06a6fedac9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/62\/i=9\/a=3735?key=crossref.c041469532124b680e716b06a6fedac9","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/62\/i=9\/a=3735\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T13:57:45Z","timestamp":1782568665000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aa6866"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4,6]]},"references-count":32,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2017,4,6]]},"published-print":{"date-parts":[[2017,5,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/aa6866","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4,6]]},"assertion":[{"value":"Total body irradiation with a compensator fabricated using a 3D optical scanner and a 3D printer","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2017 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2017-01-25","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2017-03-22","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2017-04-06","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}