{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:52:41Z","timestamp":1787759561687,"version":"build-2784847793"},"reference-count":49,"publisher":"IOP Publishing","issue":"6","license":[{"start":{"date-parts":[[2019,3,8]],"date-time":"2019-03-08T00:00:00Z","timestamp":1552003200000},"content-version":"vor","delay-in-days":7,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2019,3,8]],"date-time":"2019-03-08T00:00:00Z","timestamp":1552003200000},"content-version":"tdm","delay-in-days":7,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"crossref","award":["16K21637"],"award-info":[{"award-number":["16K21637"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2019,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    A strong demand is expected for high-sensitivity, high-resolution and low-cost brain positron emission tomography (PET) imaging for early diagnosis of dementia, as well as for general neuroscience studies. Therefore, we have proposed novel geometries of a hemisphere detector arrangement for high-sensitivity brain imaging, in which an add-on detector at the chin position or neck position helps in sensitivity uniformity improvement. In this study, we developed the first prototype system for proof-of-concept using four-layer depth-of-interaction detectors, each of which consisted of 16\u2009\u2009\u00d7\u2009\u200916\u2009\u2009\u00d7\u2009\u20094 Zr-doped GSO crystals with dimensions of 2.8\u2009\u2009\u00d7\u2009\u20092.8\u2009\u2009\u00d7\u2009\u20097.5\u2009mm\n                    <jats:sup>3<\/jats:sup>\n                    and a high-sensitivity 64-channel flat-panel photomultiplier tube. We used 47 detectors to form a hemisphere detector with a hemisphere shape of 25\u2009cm inner diameter and 50\u2009cm outer diameter, and we used seven detectors for each of the add-on detectors. The total detector number of 54 was about one-fourth that of a typical whole-body PET scanner. The hemisphere detector for the prototype system was realized by multiple rings having different numbers of detectors and a cross-shaped top detector unit covering the top. Performance evaluation showed uniform spatial resolutions of 3\u20134\u2009mm by the filtered back-projection method. Imaging tests of a hot-rod phantom done with an iterative method were able to resolve 2.2\u2009mm rods. Peak sensitivity was measured as more than 10% at a region near the top of the head, which was achieved with the help of the top detector unit. In addition, using the prototype system, we performed the first FDG clinical test with a healthy volunteer. The results showed that the proposed geometries had high potential for realizing high-sensitivity, high-resolution, and low-cost brain PET imaging. As for the add-on detector position, it was shown that the neck position resulted in higher sensitivity and wider field of view (FOV) than the chin position because the add-on detector at the neck position can be placed continuously to the hemisphere detector and close to the FOV.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ab012c","type":"journal-article","created":{"date-parts":[[2019,1,23]],"date-time":"2019-01-23T21:16:48Z","timestamp":1548278208000},"page":"065004","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":37,"title":["First prototyping of a dedicated PET system with the hemisphere detector arrangement"],"prefix":"10.1088","volume":"64","author":[{"given":"Hideaki","family":"Tashima","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eiji","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuma","family":"Iwao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidekatsu","family":"Wakizaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takamasa","family":"Maeda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chie","family":"Seki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuyuki","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuhei","family":"Takado","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Higuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuya","family":"Suhara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taichi","family":"Yamashita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taiga","family":"Yamaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2019,3,8]]},"reference":[{"key":"pmbab012cbib001","doi-asserted-by":"publisher","first-page":"p M6A2-6","DOI":"10.1109\/NSSMIC.2015.7582248)","type":"other","article-title":"Sensitivity comparison of the Helmet-chin PET with a cylindrical PET: a simulation study","author":"Ahmed","year":"2015"},{"key":"pmbab012cbib002","doi-asserted-by":"publisher","first-page":"4541","DOI":"10.1088\/1361-6560\/aa685c","type":"journal-article","article-title":"Simulation study comparing the helmet-chin PET with a cylindrical PET of the same number of detectors","volume":"62","author":"Ahmed","year":"2017a","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib003","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.nima.2017.03.044","type":"journal-article","article-title":"Investigation of the optimal detector arrangement for the helmet-chin PET-A simulation study","volume":"858","author":"Ahmed","year":"2017b","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbab012cbib004","doi-asserted-by":"publisher","DOI":"10.1002\/brb3.530","type":"journal-article","article-title":"Concept of an upright wearable positron emission tomography imager in humans","volume":"6","author":"Bauer","year":"2016","journal-title":"Brain Behav."},{"key":"pmbab012cbib005","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1118\/1.4938264","type":"journal-article","article-title":"Attenuation correction in emission tomography using the emission data\u2014a review","volume":"43","author":"Berker","year":"2016","journal-title":"Med. Phys."},{"key":"pmbab012cbib006","doi-asserted-by":"publisher","first-page":"2089","DOI":"10.1088\/0031-9155\/52\/8\/004","type":"journal-article","article-title":"A scatter-corrected list-mode reconstruction and a practical scatter\/random approximation technique for dynamic PET imaging","volume":"52","author":"Cheng","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib007","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1137\/0143028","type":"journal-article","article-title":"The ill-conditioned nature of the limited angle tomography problem","volume":"43","author":"Davison","year":"1983","journal-title":"SIAM J. Appl. Math."},{"key":"pmbab012cbib008","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1109\/TNS.1977.4328738","type":"journal-article","article-title":"High resolution computed tomography of positron emitters","volume":"24","author":"Derenzo","year":"1977","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib009","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.1109\/TNS.2002.803784","type":"journal-article","article-title":"The ECAT HRRT: NEMA NEC evaluation of the HRRT system, the new high-resolution research tomograph","volume":"49","author":"Eriksson","year":"2002","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib010","doi-asserted-by":"publisher","first-page":"N193","DOI":"10.1088\/0031-9155\/61\/5\/N193","type":"journal-article","article-title":"On the assessment of spatial resolution of PET systems with iterative image reconstruction","volume":"61","author":"Gong","year":"2016a","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib011","doi-asserted-by":"publisher","first-page":"3681","DOI":"10.1088\/0031-9155\/61\/10\/3681","type":"journal-article","article-title":"Designing a compact high performance brain PET scanner\u2014simulation study","volume":"61","author":"Gong","year":"2016b","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib012","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/s12194-013-0231-4","type":"journal-article","article-title":"Performance evaluation of a depth-of-interaction detector by use of position-sensitive PMT with a super-bialkali photocathode","volume":"7","author":"Hirano","year":"2014","journal-title":"Radiol. Phys. Technol."},{"key":"pmbab012cbib013","doi-asserted-by":"publisher","first-page":"1392","DOI":"10.2967\/jnumed.110.078949","type":"journal-article","article-title":"MRI-based attenuation correction for whole-body PET\/MRI: quantitative evaluation of segmentation- and atlas-based methods","volume":"52","author":"Hofmann","year":"2011","journal-title":"J. Nucl. Med."},{"key":"pmbab012cbib014","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1007\/s12194-007-0014-x","type":"journal-article","article-title":"Performance evaluation for 120 four-layer DOI block detectors of the jPET-D4","volume":"1","author":"Inadama","year":"2007","journal-title":"Radiol. Phys. Technol."},{"key":"pmbab012cbib015","doi-asserted-by":"publisher","first-page":"M18","DOI":"10.1109\/NSSMIC.2012.6551810","type":"other","article-title":"Development of a new brain PET scanner based on single event data acquisition","author":"Isobe","year":"2012"},{"key":"pmbab012cbib016","first-page":"p 184","type":"other","article-title":"Development of attenuation correction method for helmet-chin PET prototype using CT images","volume":"vol 36","author":"Iwao","year":"2016"},{"key":"pmbab012cbib0001a","doi-asserted-by":"publisher","first-page":"M-15-058","DOI":"10.1109\/NSSMIC.2017.8532891","type":"other","article-title":"Seated vs. supine: optimum measurement pose for brain-dedicated PET","author":"Iwao","year":"2017"},{"key":"pmbab012cbib017","doi-asserted-by":"publisher","first-page":"495","DOI":"10.2967\/jnumed.111.095240","type":"journal-article","article-title":"Methods for motion correction evaluation using 18F-FDG human brain scans on a high-resolution PET scanner","volume":"53","author":"Keller","year":"2012","journal-title":"J. Nucl. Med."},{"key":"pmbab012cbib018","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1002\/ana.20009","type":"journal-article","article-title":"Imaging brain amyloid in Alzheimer\u2019s disease with Pittsburgh Compound-B","volume":"55","author":"Klunk","year":"2004","journal-title":"Ann. Neurol."},{"key":"pmbab012cbib019","doi-asserted-by":"publisher","first-page":"553","DOI":"10.2967\/jnumed.106.037556","type":"journal-article","article-title":"2-(2-[2-Dimethylaminothiazol-5-yl]ethenyl)-6- (2-[fluoro]ethoxy)benzoxazole: a novel PET agent for in vivo detection of dense amyloid plaques in Alzheimer\u2019s disease patients","volume":"48","author":"Kudo","year":"2007","journal-title":"J. Nucl. Med."},{"key":"pmbab012cbib020","doi-asserted-by":"publisher","first-page":"7149","DOI":"10.1088\/0031-9155\/55\/23\/001","type":"journal-article","article-title":"Analog signal multiplexing for PSAPD-based PET detectors: simulation and experimental validation","volume":"55","author":"Lau","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib021","doi-asserted-by":"publisher","first-page":"98","DOI":"10.2967\/jnumed.117.203000","type":"journal-article","article-title":"Data-driven motion detection and event-by-event correction for brain PET","volume":"59","author":"Lu","year":"2018","journal-title":"J. Nucl. Med."},{"key":"pmbab012cbib022","doi-asserted-by":"publisher","DOI":"10.1100\/2012\/567067","type":"journal-article","article-title":"Automatic PET-CT image registration method based on mutual information and genetic algorithms","volume":"2012","author":"Marinelli","year":"2012","journal-title":"Sci. World J."},{"key":"pmbab012cbib023","doi-asserted-by":"publisher","first-page":"1094","DOI":"10.1016\/j.neuron.2013.07.037","type":"journal-article","article-title":"Imaging of tau pathology in a tauopathy mouse model and in Alzheimer patients compared to normal controls","volume":"79","author":"Maruyama","year":"2013","journal-title":"Neuron"},{"key":"pmbab012cbib024","doi-asserted-by":"publisher","first-page":"1152","DOI":"10.1109\/23.681994","type":"journal-article","article-title":"Depth encoding multicrystal detectors for PET","volume":"45","author":"Murayama","year":"1998","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib025","author":"National Electrical Manufacturers Association","year":"2012","type":"book"},{"key":"pmbab012cbib026","doi-asserted-by":"publisher","first-page":"10857","DOI":"10.1523\/JNEUROSCI.1738-05.2005","type":"journal-article","article-title":"Quinoline and benzimidazole derivatives: candidate probes for in vivo imaging of tau pathology in Alzheimer\u2019s disease","volume":"25","author":"Okamura","year":"2005","journal-title":"J. Neurosci."},{"key":"pmbab012cbib027","doi-asserted-by":"publisher","first-page":"M18","DOI":"10.1109\/NSSMIC.2012.6551815","type":"other","article-title":"Development of a high-resolution four-layer DOI detector using MPPCs for brain PET","author":"Omura","year":"2012"},{"key":"pmbab012cbib028","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1109\/42.75614","type":"journal-article","article-title":"Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography","volume":"10","author":"Politte","year":"1991","journal-title":"IEEE Trans. Med. Imag."},{"key":"pmbab012cbib029","doi-asserted-by":"publisher","first-page":"4887","DOI":"10.1088\/0031-9155\/50\/20\/010","type":"journal-article","article-title":"Statical dynamic image recnstruction in state-of-the-art high-resolution PET","volume":"50","author":"Rahmin","year":"2005","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib030","doi-asserted-by":"publisher","first-page":"4239","DOI":"10.1088\/0031-9155\/49\/18\/004","type":"journal-article","article-title":"Statistical list-mode image reconstruction for the high resolution research tomograph","volume":"49","author":"Rahmin","year":"2004","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib031","doi-asserted-by":"publisher","first-page":"2652","DOI":"10.1056\/NEJMoa054625","type":"journal-article","article-title":"PET of brain amyloid and tau in mild cognitive impairment","volume":"355","author":"Small","year":"2006","journal-title":"New Engl. J. Med."},{"key":"pmbab012cbib032","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.2967\/jnumed.107.045351","type":"journal-article","article-title":"Impact of image-space resolution modeling for studies with the high-resolution research tomograph","volume":"49","author":"Sureau","year":"2008","journal-title":"J. Nucl. Med."},{"key":"pmbab012cbib033","doi-asserted-by":"publisher","first-page":"M11","DOI":"10.1109\/NSSMIC.2013.6829074","type":"other","article-title":"A proposed helmet-PET with a jaw detector enabling high-sensitivity brain imaging","author":"Tashima","year":"2013"},{"key":"pmbab012cbib034","doi-asserted-by":"publisher","first-page":"7205","DOI":"10.1088\/0031-9155\/61\/19\/7205","type":"journal-article","article-title":"Proposed helmet-PET geometries with add-on detectors for high sensitivity brain imaging","volume":"61","author":"Tashima","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib035","doi-asserted-by":"publisher","first-page":"M3CP-97","DOI":"10.1109\/NSSMIC.2015.7582022","type":"other","article-title":"Development of the helmet-chin PET prototype","author":"Tashima","year":"2015"},{"key":"pmbab012cbib036","doi-asserted-by":"publisher","first-page":"2537","DOI":"10.1109\/TNS.2004.835739","type":"journal-article","article-title":"A four-layer depth-of-interaction detector block for small animal PET","volume":"51","author":"Tsuda","year":"2004","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib037","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1002\/ana.22068","type":"journal-article","article-title":"18F-flutemetamol amyloid imaging in Alzheimer disease and mild cognitive impairment a phase 2 trial","volume":"68","author":"Vandenberghe","year":"2010","journal-title":"Ann. Neurol."},{"key":"pmbab012cbib038","doi-asserted-by":"publisher","first-page":"1587","DOI":"10.1109\/23.873020","type":"journal-article","article-title":"New, faster, image-based scatter correction for 3D PET","volume":"47","author":"Watson","year":"2000","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib039","doi-asserted-by":"publisher","first-page":"913","DOI":"10.2967\/jnumed.109.069088","type":"journal-article","article-title":"In vivo imaging of amyloid deposition in Alzheimer\u2019s disease using the novel radioligand [18F]AV-45 (Florbetapir F 18)","volume":"51","author":"Wong","year":"2010","journal-title":"J. Nucl. Med."},{"key":"pmbab012cbib040","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1109\/TNS.2011.2105502","type":"journal-article","article-title":"Development of a brain PET system, PET-Hat: a wearable PET system for brain research","volume":"58","author":"Yamamoto","year":"2011","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib041","doi-asserted-by":"publisher","first-page":"1404","DOI":"10.1109\/TNS.2003.817307","type":"journal-article","article-title":"DOI-PET image reconstruction with accurate system modeling that reduces redundancy of the imaging system","volume":"50","author":"Yamaya","year":"2003","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib042","doi-asserted-by":"publisher","first-page":"6793","DOI":"10.1088\/0031-9155\/56\/21\/003","type":"journal-article","article-title":"A SiPM-based isotropic-3D PET detector X\u2019tal cube with a three-dimensional array of 1\u2009mm3 crystals","volume":"56","author":"Yamaya","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib043","doi-asserted-by":"publisher","first-page":"2482","DOI":"10.1109\/TNS.2008.2003252","type":"journal-article","article-title":"First human brain imaging by the jPET-D4 prototype with a pre-computed system matrix","volume":"55","author":"Yamaya","year":"2008","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib044","doi-asserted-by":"publisher","first-page":"5339","DOI":"10.1088\/0031-9155\/50\/22\/009","type":"journal-article","article-title":"Transaxial system models for jPET-D4 image reconstruction","volume":"50","author":"Yamaya","year":"2005","journal-title":"Phys. Med. Biol."},{"key":"pmbab012cbib045","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1109\/TNS.2012.2187214","type":"journal-article","article-title":"Development of the X\u2019 tal cube: a 3D position-sensitive radiation detector with all-surface MPPC readout","volume":"59","author":"Yazaki","year":"2012","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbab012cbib046","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/s12194-012-0167-0","type":"journal-article","article-title":"Intrinsic spatial resolution evaluation of the X\u2019tal cube PET detector based on a 3D crystal block segmented by laser processing","volume":"6","author":"Yoshida","year":"2013","journal-title":"Radiol. Phys. Technol."},{"key":"pmbab012cbib047","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1109\/TRPMS.2017.2703823","type":"journal-article","article-title":"Development of a whole-body dual ring OpenPET for in-beam PET","volume":"1","author":"Yoshida","year":"2017","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbab012cbib048","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1109\/TNS.2007.894128","type":"journal-article","article-title":"Performance characterization of a novel thin position-sensitive avalanche photodiode for 1\u2009mm resolution positron emission tomography","volume":"54","author":"Zhang","year":"2007","journal-title":"IEEE Trans. Nucl. Sci."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/64\/i=6\/a=065004\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/64\/i=6\/a=065004?key=crossref.2c3dad7b7eed83a509efc08c1981d568","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/64\/i=6\/a=065004\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0031-9155\/64\/i=6\/a=065004?key=crossref.2c3dad7b7eed83a509efc08c1981d568","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T12:13:55Z","timestamp":1770466435000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab012c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,1]]},"references-count":49,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2019,3,8]]},"published-print":{"date-parts":[[2019,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ab012c","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,1]]},"assertion":[{"value":"First prototyping of a dedicated PET system with the hemisphere detector arrangement","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2019 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2018-08-13","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-01-23","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-03-08","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}