{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:02:55Z","timestamp":1789689775589,"version":"4.0.1"},"reference-count":37,"publisher":"IOP Publishing","issue":"18","license":[{"start":{"date-parts":[[2019,9,19]],"date-time":"2019-09-19T00:00:00Z","timestamp":1568851200000},"content-version":"vor","delay-in-days":18,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2019,9,19]],"date-time":"2019-09-19T00:00:00Z","timestamp":1568851200000},"content-version":"tdm","delay-in-days":18,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"crossref","award":["U01EB021183"],"award-info":[{"award-number":["U01EB021183"]}],"id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2019,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    While CTA is an established clinical gold standard for imaging large cerebral arteries and veins, an important challenge that currently remains for CTA is its limited performance in imaging small perforating arteries with diameters below 0.5\u2009mm. The purpose of this work was to theoretically and experimentally study the potential benefits of using photon counting detector (PCD)-based CT (PCCT) to improve the performance of CTA in imaging these small arteries. In particular, the study focused on an important component of the CTA image package known as the maximum intensity projection (MIP) image. To help understand how the physical properties of a detector quantitatively influence the MIP image quality, a theoretical model on the statistical properties of MIP images was developed. After validating this model, it was used to explore the individual and joint contribution of the following detector properties to the MIP signal-to-noise ratio (SNR): inter-slice noise covariance, spatial resolution along the\n                    <jats:italic>z<\/jats:italic>\n                    direction, and native pixel pitch along\n                    <jats:italic>z<\/jats:italic>\n                    . The model demonstrated that superior slice sensitivity, reduced inter-slice noise correlation, and smaller native pixel pitch along\n                    <jats:italic>z<\/jats:italic>\n                    provided by PCDs lead to improved vessel SNR in MIP images. Finally, experiments were performed by scanning an anthropomorphic cerebral angiographic phantom using a benchtop PCCT system and a commercial MDCT system. The experimental MIP results consistently demonstrated that compared with MDCT, PCCT provides superior vessel conspicuity and reduced artifactual stenosis.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ab32fe","type":"journal-article","created":{"date-parts":[[2019,7,17]],"date-time":"2019-07-17T18:30:24Z","timestamp":1563388224000},"page":"185015","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":27,"title":["Impacts of photon counting CT to maximum intensity projection (MIP) images of cerebral CT angiography: theoretical and experimental studies"],"prefix":"10.1088","volume":"64","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3184-7461","authenticated-orcid":false,"given":"Evan Cary","family":"Harvey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7343-0525","authenticated-orcid":false,"given":"Mang","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xu","family":"Ji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ran","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1635-5178","authenticated-orcid":false,"given":"Yinsheng","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guang-Hong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2672-2672","authenticated-orcid":false,"given":"Ke","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2019,9,19]]},"reference":[{"key":"pmbab32febib001","article-title":"American College of Radiology appropriateness criteria cerebrovascular disease","author":"ACR","year":"2016","type":"web-resource"},{"key":"pmbab32febib002","doi-asserted-by":"publisher","first-page":"488","DOI":"10.3174\/ajnr.A4131","type":"journal-article","article-title":"Strategies of collateral blood flow assessment in ischemic stroke: prediction of the follow-up infarct volume in conventional and dynamic CTA","volume":"36","author":"Bejer","year":"2015","journal-title":"Am. J. Neuroradiol."},{"key":"pmbab32febib003","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/8\/02\/C02028","type":"journal-article","article-title":"Chromatic x-ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC","volume":"8","author":"Bellazzini","year":"2013","journal-title":"J. Instrum."},{"key":"pmbab32febib004","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.sjopt.2014.10.001","type":"journal-article","article-title":"Review of giant cell arteritis","volume":"29","author":"Chacko","year":"2015","journal-title":"Saudi J. Ophthalmol."},{"key":"pmbab32febib005","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1118\/1.594678","type":"journal-article","article-title":"Nonlinear partial volume artifacts in x-ray computed tomography","volume":"7","author":"Glover","year":"1980","journal-title":"Med. Phys."},{"key":"pmbab32febib006","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1097\/00005792-199909000-00002","type":"journal-article","article-title":"Systemic vasculitis in adults in Northwestern Spain, 1988\u20131997 clinical and epidemiologic aspects","volume":"78","author":"Gonz\u00e1lez-Gay","year":"1999","journal-title":"Medicine"},{"key":"pmbab32febib007","author":"Hsieh","year":"2003","type":"book"},{"key":"pmbab32febib008","doi-asserted-by":"publisher","DOI":"10.1117\/12.2217180","type":"journal-article","article-title":"A high-resolution imaging technique using a whole-body, research photon counting detector CT system","volume":"9783","author":"Leng","year":"2016","journal-title":"Proc. SPIE"},{"key":"pmbab32febib009","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1097\/RLI.0000000000000488","type":"journal-article","article-title":"150 \u03bcm spatial resolution using photon-counting detector computed tomography technology: technical performance and first patient images","volume":"53","author":"Leng","year":"2018","journal-title":"Investigative Radiol."},{"key":"pmbab32febib010","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1002\/ima.22259","type":"journal-article","article-title":"Control study of low tube voltage computed tomography angiography (CTA) and digital subtraction angiography (DSA) in diagnosing intracranial micro-aneurysm","volume":"28","author":"Li","year":"2017","journal-title":"IMA"},{"key":"pmbab32febib011","doi-asserted-by":"publisher","first-page":"1677","DOI":"10.1007\/s00330-014-3184-z","type":"journal-article","article-title":"Low tube voltage and low contrast material volume cerebral CT angiography","volume":"24","author":"Luo","year":"2014","journal-title":"Eur. Radiol."},{"key":"pmbab32febib012","doi-asserted-by":"crossref","DOI":"10.37206\/97","type":"report","article-title":"The measurement, reporting, and management of radiation dose in CT","author":"McCollough","year":"2008"},{"key":"pmbab32febib013","article-title":"Radiation detector and method for producing a radiation detector","author":"Miess","year":"2011","type":"patent"},{"key":"pmbab32febib014","doi-asserted-by":"publisher","first-page":"2257","DOI":"10.3174\/ajnr.A5402","type":"journal-article","article-title":"Photon-counting CT of the brain: in vivo human results and image-quality assessment","volume":"38","author":"Pourmorteza","year":"2017","journal-title":"Am. J. Neuroradiol."},{"key":"pmbab32febib015","doi-asserted-by":"publisher","first-page":"3881","DOI":"10.1088\/0031-9155\/54\/12\/018","type":"journal-article","article-title":"Comparison of ring artifact correction methods for flat-detector CT","volume":"54","author":"Prell","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmbab32febib016","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1148\/rg.344135028","type":"journal-article","article-title":"Imaging spectrum of CNS vasculitis","volume":"34","author":"Razek","year":"2014","journal-title":"RadioGraphics"},{"key":"pmbab32febib017","doi-asserted-by":"publisher","first-page":"4679","DOI":"10.1088\/0031-9155\/52\/15\/020","type":"journal-article","article-title":"K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors","volume":"52","author":"Roessl","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"pmbab32febib018","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1148\/radiol.14132232","type":"journal-article","article-title":"CT angiography after 20 years","volume":"271","author":"Rubin","year":"2014","journal-title":"Radiology"},{"key":"pmbab32febib019","doi-asserted-by":"publisher","first-page":"3018","DOI":"10.1118\/1.3148535","type":"journal-article","article-title":"Optimal image-based weighting for energy-resolved CT","volume":"36","author":"Schmidt","year":"2009","journal-title":"Med. Phys."},{"key":"pmbab32febib020","doi-asserted-by":"publisher","first-page":"1475","DOI":"10.1088\/0031-9155\/53\/5\/020","type":"journal-article","article-title":"Computed tomography with energy-resolved detection: a feasibility study","volume":"53","author":"Shikhaliev","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"pmbab32febib021","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1148\/radiol.2017162587","type":"journal-article","article-title":"Feasibility of dose-reduced chest CT with photon-counting detectors: initial results in humans","volume":"285","author":"Symons","year":"2017","journal-title":"Radiology"},{"key":"pmbab32febib022","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1097\/RLI.0000000000000418","type":"journal-article","article-title":"Photon-counting computed tomography vascular imaging of the head and neck first in vivo human results","volume":"53","author":"Symons","year":"2018","journal-title":"Investigative Radiol."},{"key":"pmbab32febib023","first-page":"19","type":"journal-article","article-title":"A team approach for CT protocol optimization","volume":"38","author":"Szczykutowicz","year":"2016","journal-title":"Radiol. Manage."},{"key":"pmbab32febib024","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1016\/j.jacr.2015.10.021","type":"journal-article","article-title":"A Wiki-based solution to managing your institution\u2019s imaging protocols","volume":"13","author":"Szczykutowicz","year":"2016","journal-title":"J. Am. College Radiol."},{"key":"pmbab32febib025","doi-asserted-by":"publisher","DOI":"10.1118\/1.4820371","type":"journal-article","article-title":"Vision 20\/20: single photon counting x-ray detectors in medical imaging","volume":"40","author":"Taguchi","year":"2013","journal-title":"Med. Phys."},{"key":"pmbab32febib026","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/876796","type":"journal-article","article-title":"The value of cerebral CT angiography with low tube voltage in detection of intracranial aneurysms","volume":"2015","author":"Tang","year":"2015","journal-title":"Biomed. Res. Int."},{"key":"pmbab32febib027","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1088\/0031-9155\/30\/6\/002","type":"journal-article","article-title":"SNR and DQE analysis of broad spectrum x-ray imaging","volume":"30","author":"Tapiovaara","year":"1985","journal-title":"Phys. Med. Biol."},{"key":"pmbab32febib028","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1148\/rg.243035126","type":"journal-article","article-title":"CT angiography of intracranial anuerysms: a focus on postprocessing","volume":"24","author":"Tomandl","year":"2004","journal-title":"RadioGraphics"},{"key":"pmbab32febib029","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1161\/hs0102.101223","type":"journal-article","article-title":"CT angiography in acute ischemic stroke: preliminary results","volume":"33","author":"Verro","year":"2002","journal-title":"Stroke"},{"key":"pmbab32febib030","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","type":"journal-article","article-title":"Photon-counting CT: technical principles and clinical prospects","volume":"289","author":"Willemink","year":"2018","journal-title":"Radiology"},{"key":"pmbab32febib031","doi-asserted-by":"publisher","DOI":"10.1118\/1.4894733","type":"journal-article","article-title":"Cascaded systems analysis of photon counting detectors","volume":"41","author":"Xu","year":"2014","journal-title":"Med. Phys."},{"key":"pmbab32febib032","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1109\/NSSMIC.2000.949387","type":"other","article-title":"Direct conversion CdZnTe and CdTe detectors for digital mammography","volume":"3","author":"Yin","year":"2000"},{"key":"pmbab32febib033","doi-asserted-by":"publisher","first-page":"1926","DOI":"10.3938\/jkps.66.1926","type":"journal-article","article-title":"Characterization of on-site digital mammography systems: direct versus indirect conversion detectors","volume":"66","author":"Youn","year":"2015","journal-title":"J. Korean Phys. Soc."},{"key":"pmbab32febib034","doi-asserted-by":"publisher","DOI":"10.1117\/12.2082739","type":"journal-article","article-title":"Initial results from a prototype whole-body photon-counting computed tomography system","volume":"9412","author":"Yu","year":"2015","journal-title":"Proc. SPIE"},{"key":"pmbab32febib035","doi-asserted-by":"publisher","first-page":"1572","DOI":"10.1088\/0031-9155\/61\/4\/1572","type":"journal-article","article-title":"Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array","volume":"61","author":"Yu","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"pmbab32febib036","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.1118\/1.1405845","type":"journal-article","article-title":"Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors","volume":"28","author":"Zhao","year":"2001","journal-title":"Med. Phys."},{"key":"pmbab32febib037","doi-asserted-by":"publisher","DOI":"10.1117\/12.2294952","type":"journal-article","article-title":"Impact of photon counting detector technology on kV selection and diagnostic workflow in CT","volume":"10573","author":"Zhou","year":"2018","journal-title":"Proc. SPIE"}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T12:29:49Z","timestamp":1770467389000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab32fe"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,9,1]]},"references-count":37,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2019,9,19]]},"published-print":{"date-parts":[[2019,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ab32fe","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,9,1]]},"assertion":[{"value":"Impacts of photon counting CT to maximum intensity projection (MIP) images of cerebral CT angiography: theoretical and experimental studies","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2019 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2019-04-06","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-07-17","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-09-19","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}