{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T13:43:18Z","timestamp":1795095798620,"version":"4.10.2"},"reference-count":21,"publisher":"IOP Publishing","issue":"23","license":[{"start":{"date-parts":[[2019,12,5]],"date-time":"2019-12-05T00:00:00Z","timestamp":1575504000000},"content-version":"vor","delay-in-days":4,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2019,12,5]],"date-time":"2019-12-05T00:00:00Z","timestamp":1575504000000},"content-version":"tdm","delay-in-days":4,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2019,12,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>A method using both patient geometric and dosimetric information was proposed to predict dose-volume histograms (DVHs) of organs at risk (OARs) for a nasopharyngeal cancer (NPC) intensity-modulated radiation therapy (IMRT) plan.<\/jats:p>\n                  <jats:p>\n                    A total of 106 nine-field IMRT NPC plans were used in this study. Twenty-six plans were randomly selected as testing cases, and the remaining plans were used as the training data. A method employing geometric and dosimetric information was developed for OAR DVH prediction. The dosimetric information was derived from an initial dose calculation using a simple unoptimized conformal plan. The DVHs were also predicted using only the geometric information. The DVH prediction model was a generalized regression neural network (GRNN). Mean absolute error (MAE) and\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    values were introduced to evaluate DVH prediction accuracy.\n                  <\/jats:p>\n                  <jats:p>\n                    Significant differences in the DVH prediction accuracy were found between the method employing the geometric and dosimetric information and the method utilizing the geometric information for the brainstem (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    , 0.98 versus 0.95,\n                    <jats:italic>p<\/jats:italic>\n                    \u200a\u2009\u2009=\u2009\u20090.007; MAE, 3.52% versus 7.19%,\n                    <jats:italic>p<\/jats:italic>\n                    \u200a\u2009\u2009=\u2009\u20090.002), spinal cord (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    , 0.98 versus 0.96,\n                    <jats:italic>p<\/jats:italic>\n                    \u200a\u2009\u2009&lt;\u2009\u20090.001; MAE, 2.80% versus 4.36%,\n                    <jats:italic>p<\/jats:italic>\n                    \u200a\u2009\u2009&lt;\u2009\u20090.001), left optic nerve (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    , 0.90 versus 0.77,\n                    <jats:italic>p<\/jats:italic>\n                    \u200a\u2009\u2009=\u2009\u20090.014; MAE, 3.07% versus 11.29%,\n                    <jats:italic>p<\/jats:italic>\n                    \u200a\u2009\u2009=\u2009\u20090.025) and other organs. On average, the\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    value increased by ~6.7% and the MAE value decreased by ~46.7% after adding the dosimetric information to the DVH prediction.\n                  <\/jats:p>\n                  <jats:p>We developed a method for predicting DVHs of OARs in NPC IMRT plans by using geometric and dosimetric information. Adding dosimetric information can help predict the DVHs of OARs in NPC IMRT plans.<\/jats:p>","DOI":"10.1088\/1361-6560\/ab50eb","type":"journal-article","created":{"date-parts":[[2019,10,24]],"date-time":"2019-10-24T18:46:28Z","timestamp":1571942788000},"page":"23NT04","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":31,"title":["Prediction of dose-volume histograms in nasopharyngeal cancer IMRT using geometric and dosimetric information"],"prefix":"10.1088","volume":"64","author":[{"given":"Sheng-Xiu","family":"Jiao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-Xin","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Han","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming-Li","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7276-0787","authenticated-orcid":false,"given":"Xiao-Wei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2019,12,5]]},"reference":[{"key":"pmbab50ebbib001","doi-asserted-by":"publisher","first-page":"7446","DOI":"10.1118\/1.4761864","type":"journal-article","article-title":"Predicting dose-volume histograms for organs-at-risk in IMRT planning","volume":"39","author":"Appenzoller","year":"2012","journal-title":"Med. Phys."},{"key":"pmbab50ebbib002","doi-asserted-by":"publisher","first-page":"6148","DOI":"10.1002\/mp.12621","type":"journal-article","article-title":"Neural network dose models for knowledge-based planning in pancreatic SBRT","volume":"44","author":"Campbell","year":"2017","journal-title":"Med. Phys."},{"key":"pmbab50ebbib003","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/j.ijrobp.2016.02.017","type":"journal-article","article-title":"Comparison of planning quality and efficiency between conventional and knowledge based algorithms in nasopharyngeal cancer patients using intensity-modulated radiotherapy","volume":"95","author":"Chang","year":"2016","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbab50ebbib004","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1186\/s13014-015-0533-2","type":"journal-article","article-title":"Evaluation of an automated knowledge based treatment planning system for head and neck","volume":"10","author":"Krayenbuehl","year":"2015","journal-title":"Radiat. Oncol."},{"key":"pmbab50ebbib005","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1002\/mp.13334","type":"journal-article","article-title":"Dosimetric features-driven machine learning model for DVH prediction in VMAT treatment planning","volume":"46","author":"Ma","year":"2019","journal-title":"Med. Phys."},{"key":"pmbab50ebbib006","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/489\/1\/012055","type":"journal-article","article-title":"Clinical implementation of dose-volume histogram predictions for organs-at-risk in IMRT planning","volume":"489","author":"Moore","year":"2014","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmbab50ebbib007","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1016\/j.ijrobp.2010.11.030","type":"journal-article","article-title":"Experience-based quality control of clinical intensity-modulated radiotherapy planning","volume":"81","author":"Moore","year":"2011","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbab50ebbib008","author":"OFFIS Open Source DICOM Toolkit DCMTK","year":"2017","type":"web-resource"},{"key":"pmbab50ebbib009","doi-asserted-by":"publisher","DOI":"10.1118\/1.4894496","type":"journal-article","article-title":"Within the next ten years treatment planning will become fully automated without the need for human intervention","volume":"41","author":"Sharpe","year":"2014","journal-title":"Med. Phys."},{"key":"pmbab50ebbib010","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1118\/1.4938583","type":"journal-article","article-title":"Knowledge-based prediction of three-dimensional dose distributions for external beam radiotherapy","volume":"43","author":"Shiraishi","year":"2016","journal-title":"Med. Phys."},{"key":"pmbab50ebbib011","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1109\/72.97934","type":"journal-article","article-title":"A general regression neural networks","volume":"2","author":"Specht","year":"1991","journal-title":"IEEE Trans. Neural Netw."},{"key":"pmbab50ebbib012","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa9a30","type":"journal-article","article-title":"An improved distance-to-dose correlation for predicting bladder and rectum dose-volumes in knowledge-based VMAT planning for prostate cancer","volume":"63","author":"Wall","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbab50ebbib013","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1186\/s13014-017-0822-z","type":"journal-article","article-title":"Is it possible for knowledge-based planning to improve intensity modulated radiation therapy plan quality for planners with different planning experiences in left-sided breast cancer patients?","volume":"12","author":"Wang","year":"2017","journal-title":"Radiat. Oncol."},{"key":"pmbab50ebbib014","doi-asserted-by":"publisher","first-page":"2556","DOI":"10.1002\/mp.12251","type":"journal-article","article-title":"Development of the open-source dose calculation and optimization toolkit matrad","volume":"44","author":"Wieser","year":"2017","journal-title":"Med. Phys."},{"key":"pmbab50ebbib015","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.radonc.2014.07.009","type":"journal-article","article-title":"Improved robotic stereotactic body radiation therapy plan quality and planning efficacy for organ-confined prostate cancer utilizing overlap-volume histogram-driven planning methodology","volume":"112","author":"Wu","year":"2014","journal-title":"Radiother. Oncol."},{"key":"pmbab50ebbib016","doi-asserted-by":"publisher","DOI":"10.1118\/1.4788671","type":"journal-article","article-title":"Using overlap volume histogram and IMRT plan data to guide and automate VMAT planning: a head-and-neck case study","volume":"40","author":"Wu","year":"2013","journal-title":"Med. Phys."},{"key":"pmbab50ebbib017","doi-asserted-by":"publisher","first-page":"5497","DOI":"10.1118\/1.3253464","type":"journal-article","article-title":"Patient geometry-driven information retrieval for IMRT treatment plan quality control","volume":"36","author":"Wu","year":"2009","journal-title":"Med. Phys."},{"key":"pmbab50ebbib018","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1016\/j.ijrobp.2010.05.026","type":"journal-article","article-title":"Data-driven approach to generating achievable dose-volume histogram objectives in intensity-modulated radiotherapy planning","volume":"79","author":"Wu","year":"2011","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbab50ebbib019","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1186\/s13014-016-0684-9","type":"journal-article","article-title":"Applying a RapidPlan model trained on a technique and orientation to another: a feasibility and dosimetric evaluation","volume":"11","author":"Wu","year":"2016","journal-title":"Radiat. Oncol."},{"key":"pmbab50ebbib020","doi-asserted-by":"publisher","first-page":"6868","DOI":"10.1118\/1.4757927","type":"journal-article","article-title":"Quantitative analysis of the factors which affect the interpatient organ-at-risk dose sparing variation in IMRT plans","volume":"39","author":"Yuan","year":"2012","journal-title":"Med. Phys."},{"key":"pmbab50ebbib021","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1118\/1.3539749","type":"journal-article","article-title":"A planning quality evaluation tool for prostate adaptive IMRT based on machine learning","volume":"38","author":"Zhu","year":"2011","journal-title":"Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T12:37:31Z","timestamp":1770467851000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ab50eb"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,1]]},"references-count":21,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2019,12,5]]},"published-print":{"date-parts":[[2019,12,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ab50eb","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,1]]},"assertion":[{"value":"Prediction of dose-volume histograms in nasopharyngeal cancer IMRT using geometric and dosimetric information","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2019 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2019-07-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-10-24","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-12-05","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}