{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T11:39:50Z","timestamp":1780573190799,"version":"3.54.1"},"reference-count":23,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2021,2,2]],"date-time":"2021-02-02T00:00:00Z","timestamp":1612224000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,2,2]],"date-time":"2021-02-02T00:00:00Z","timestamp":1612224000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2021,2,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>We describe a radiation therapy treatment plan optimization method that explicitly considers the effects of interfraction organ motion through optimization on the clinical target volume (CTV), and investigate how it compares to conventional planning using a planning target volume (PTV). The method uses simulated treatment courses generated using patient images created by a deformable registration algorithm to replicate the effects of interfraction organ motion, and performs robust optimization aiming to achieve CTV coverage under all simulated treatment courses. The method was applied to photon-mediated treatments of three prostate cases and compared to conventional, PTV-based planning with margins selected to achieve similar CTV coverage as the robustly optimized plans. Clinical goals for the CTV and healthy tissue were used in comparison between the two types of plans. Out of the two clinical goals for overdosage of the CTV, the three robustly optimized plans violated respectively 2, 2, and 0 goals in the mean over the scenarios, whereas none of the PTV plans violated these goals. Of the ten clinical goals for rectum, bladder, anal canal, and bulbus, the robustly optimized plans violated respectively 0, 1, and 1 goals in the mean, whereas the PTV plans violated 5, 7, and 4 goals. Compared to PTV-based planning, the inclusion of treatment course scenarios in the optimization has the potential to reduce the dose to healthy tissues while retaining a high probability of target coverage. This may reduce the need for adaptive replanning.<\/jats:p>","DOI":"10.1088\/1361-6560\/abd591","type":"journal-article","created":{"date-parts":[[2020,12,21]],"date-time":"2020-12-21T20:36:45Z","timestamp":1608583005000},"page":"045010","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["Robust radiation therapy optimization using simulated treatment courses for handling deformable organ motion"],"prefix":"10.1088","volume":"66","author":[{"given":"Albin","family":"Fredriksson","sequence":"first","affiliation":[{"name":"RaySearch Laboratories, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Engwall","sequence":"additional","affiliation":[{"name":"RaySearch Laboratories, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bj\u00f6rn","family":"Andersson","sequence":"additional","affiliation":[{"name":"RaySearch Laboratories, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2021,2,2]]},"reference":[{"key":"pmbabd591bib1","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1118\/1.596360","type":"journal-article","article-title":"Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media","volume":"16","author":"Ahnesj\u00f6","year":"1989","journal-title":"Med. Phys."},{"key":"pmbabd591bib2","doi-asserted-by":"publisher","first-page":"3563","DOI":"10.1088\/0031-9155\/58\/11\/3563","type":"journal-article","article-title":"Probabilistic objective functions for margin-less IMRT planning","volume":"58","author":"Bohoslavsky","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbabd591bib3","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1118\/1.597070","type":"journal-article","article-title":"Decomposition of pencil beam kernels for fast dose calculations in three\u2010dimensional treatment planning","volume":"20","author":"Bortfeld","year":"1993","journal-title":"Med. Phys."},{"key":"pmbabd591bib4","doi-asserted-by":"publisher","first-page":"2567","DOI":"10.1088\/0031-9155\/51\/10\/014","type":"journal-article","article-title":"A robust approach to IMRT optimization","volume":"51","author":"Chan","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"pmbabd591bib5","doi-asserted-by":"publisher","first-page":"2012","DOI":"10.1118\/1.1589493","type":"journal-article","article-title":"Limitations of a convolution method for modeling geometric uncertainties in radiation therapy: II. The effect of a finite number of fractions","volume":"30","author":"Craig","year":"2003","journal-title":"Med. Phys."},{"key":"pmbabd591bib6","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.ctro.2019.04.004","type":"journal-article","article-title":"Evaluation of organ motion-based robust optimisation for VMAT planning for breast and internal mammary chain radiotherapy","volume":"16","author":"Dunlop","year":"2019","journal-title":"Clin. Transl. Radiat. Oncol."},{"key":"pmbabd591bib7","doi-asserted-by":"publisher","first-page":"4020","DOI":"10.1002\/mp.13094","type":"journal-article","article-title":"4D robust optimization including uncertainties in time structures can reduce the interplay effect in proton pencil beam scanning radiation therapy","volume":"45","author":"Engwall","year":"2018","journal-title":"Med. Phys."},{"key":"pmbabd591bib8","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1118\/1.3273063","type":"journal-article","article-title":"Coverage optimized planning: probabilistic treatment planning based on dose coverage histogram criteria","volume":"37","author":"Gordon","year":"2010","journal-title":"Med. Phys."},{"key":"pmbabd591bib9","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1016\/j.ejmp.2014.03.011","type":"journal-article","article-title":"Motion mitigation in scanned ion beam therapy through 4D-optimization","volume":"30","author":"Graeff","year":"2014","journal-title":"Phys. Med."},{"key":"pmbabd591bib24","doi-asserted-by":"publisher","first-page":"3059","DOI":"10.1118\/1.3148582","type":"journal-article","article-title":"Incorporating uncertainties in respiratory motion into 4D treatment plan optimization","volume":"36","author":"Heath","year":"2009","journal-title":"Med. Phys."},{"key":"pmbabd591bib10","volume":"vol 10","author":"International Commission on Radiation Units and Measurements","year":"2010","type":"book"},{"key":"pmbabd591bib11","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1088\/0266-5611\/11\/6\/005","type":"journal-article","article-title":"Optimal radiation beam profiles considering the stochastic process of patient positioning in fractionated radiation therapy","volume":"11","author":"L\u00f6f","year":"1995","journal-title":"Inverse Problems"},{"key":"pmbabd591bib13","doi-asserted-by":"publisher","first-page":"3880","DOI":"10.1118\/1.3176940","type":"journal-article","article-title":"Comparisons of treatment optimization directly incorporating random patient setup uncertainty with a margin\u2010based approach","volume":"36","author":"Moore","year":"2009","journal-title":"Med. Phys."},{"key":"pmbabd591bib14","doi-asserted-by":"publisher","first-page":"21","DOI":"10.21314\/JOR.2000.038","type":"journal-article","article-title":"Optimization of conditional value-at-risk","volume":"2","author":"Rockafellar","year":"2000","journal-title":"J. Risk"},{"key":"pmbabd591bib15","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1016\/j.ijrobp.2009.04.016","type":"journal-article","article-title":"Intensity-modulated radiotherapy optimization in a quasi-periodically deforming patient model","volume":"75","author":"S\u00f6hn","year":"2009","journal-title":"Int. J. Radiat. Oncol.* Biol.* Phys."},{"key":"pmbabd591bib16","doi-asserted-by":"publisher","first-page":"3693","DOI":"10.1088\/0031-9155\/57\/12\/3693","type":"journal-article","article-title":"Dosimetric treatment course simulation based on a statistical model of deformable organ motion","volume":"57","author":"S\u00f6hn","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbabd591bib17","article-title":"Probabilistic treatment planning based on dose coverage: how to quantify and minimize the effects of geometric uncertainties in radiotherapy","author":"Tilly","year":"2016","type":"other"},{"key":"pmbabd591bib18","doi-asserted-by":"publisher","first-page":"4005","DOI":"10.1088\/0031-9155\/49\/17\/013","type":"journal-article","article-title":"Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions","volume":"49","author":"Unkelbach","year":"2004","journal-title":"Phys. Med. Biol."},{"key":"pmbabd591bib19","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1016\/S0360-3016(00)00518-6","type":"journal-article","article-title":"The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy","volume":"47","author":"van Herk","year":"2000","journal-title":"Int. J. Radiat. Oncol.* Biol.* Phys."},{"key":"pmbabd591bib20","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1118\/1.4894702","type":"journal-article","article-title":"The ANACONDA algorithm for deformable image registration in radiotherapy","volume":"42","author":"Weistrand","year":"2015","journal-title":"Med. Phys."},{"key":"pmbabd591bib21","doi-asserted-by":"publisher","first-page":"3544","DOI":"10.1118\/1.2760027","type":"journal-article","article-title":"IMRT optimization including random and systematic geometric errors based on the expectation of TCP and NTCP","volume":"34","author":"Witte","year":"2007","journal-title":"Med. Phys."},{"key":"pmbabd591bib22","doi-asserted-by":"publisher","first-page":"7874","DOI":"10.1088\/1361-6560\/aa87fe","type":"journal-article","article-title":"Beyond the margin recipe: the probability of correct target dosage and tumor control in the presence of a dose limiting structure","volume":"62","author":"Witte","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"pmbabd591bib23","doi-asserted-by":"publisher","DOI":"10.1118\/1.4894701","type":"journal-article","article-title":"Coverage\u2010based treatment planning to accommodate deformable organ variations in prostate cancer treatment","volume":"41","author":"Xu","year":"2014","journal-title":"Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:24:57Z","timestamp":1778775897000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd591"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,2]]},"references-count":23,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021,2,2]]},"published-print":{"date-parts":[[2021,2,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/abd591","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,2]]},"assertion":[{"value":"Robust radiation therapy optimization using simulated treatment courses for handling deformable organ motion","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-08-10","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-12-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-02-02","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}