{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,13]],"date-time":"2026-09-13T03:23:15Z","timestamp":1789269795044,"version":"build-2803163510"},"reference-count":49,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2021,2,10]],"date-time":"2021-02-10T00:00:00Z","timestamp":1612915200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,2,10]],"date-time":"2021-02-10T00:00:00Z","timestamp":1612915200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"National Cancer Institute","award":["R01CA215718"],"award-info":[{"award-number":["R01CA215718"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2021,2,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Organ-at-risk (OAR) delineation is a key step for cone-beam CT (CBCT) based adaptive radiotherapy planning that can be a time-consuming, labor-intensive, and subject-to-variability process. We aim to develop a fully automated approach aided by synthetic MRI for rapid and accurate CBCT multi-organ contouring in head-and-neck (HN) cancer patients. MRI has superb soft-tissue contrasts, while CBCT offers bony-structure contrasts. Using the complementary information provided by MRI and CBCT is expected to enable accurate multi-organ segmentation in HN cancer patients. In our proposed method, MR images are firstly synthesized using a pre-trained cycle-consistent generative adversarial network given CBCT. The features of CBCT and synthetic MRI (sMRI) are then extracted using dual pyramid networks for final delineation of organs. CBCT images and their corresponding manual contours were used as pairs to train and test the proposed model. Quantitative metrics including Dice similarity coefficient (DSC), Hausdorff distance 95% (HD95), mean surface distance, and residual mean square distance (RMS) were used to evaluate the proposed method. The proposed method was evaluated on a cohort of 65 HN cancer patients. CBCT images were collected from those patients who received proton therapy. Overall, DSC values of 0.87\u00a0\u00b1\u00a00.03, 0.79\u00a0\u00b1\u00a00.10\/0.79\u00a0\u00b1\u00a00.11, 0.89\u00a0\u00b1\u00a00.08\/0.89\u00a0\u00b1\u00a00.07, 0.90\u00a0\u00b1\u00a00.08, 0.75\u00a0\u00b1\u00a00.06\/0.77\u00a0\u00b1\u00a00.06, 0.86\u00a0\u00b1\u00a00.13, 0.66\u00a0\u00b1\u00a00.14, 0.78\u00a0\u00b1\u00a00.05\/0.77\u00a0\u00b1\u00a00.04, 0.96\u00a0\u00b1\u00a00.04, 0.89\u00a0\u00b1\u00a00.04\/0.89\u00a0\u00b1\u00a00.04, 0.83\u00a0\u00b1\u00a00.02, and 0.84\u00a0\u00b1\u00a00.07 for commonly used OARs for treatment planning including brain stem, left\/right cochlea, left\/right eye, larynx, left\/right lens, mandible, optic chiasm, left\/right optic nerve, oral cavity, left\/right parotid, pharynx, and spinal cord, respectively, were achieved. This study provides a rapid and accurate OAR auto-delineation approach, which can be used for adaptive radiation therapy.<\/jats:p>","DOI":"10.1088\/1361-6560\/abd953","type":"journal-article","created":{"date-parts":[[2021,1,8]],"date-time":"2021-01-08T07:03:36Z","timestamp":1610089416000},"page":"045021","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":41,"title":["Head-and-neck organs-at-risk auto-delineation using dual pyramid networks for CBCT-guided adaptive radiotherapy"],"prefix":"10.1088","volume":"66","author":[{"given":"Xianjin","family":"Dai","sequence":"first","affiliation":[{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3572-0345","authenticated-orcid":false,"given":"Yang","family":"Lei","sequence":"additional","affiliation":[{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tonghe","family":"Wang","sequence":"additional","affiliation":[{"name":"Emory University"},{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anees H","family":"Dhabaan","sequence":"additional","affiliation":[{"name":"Emory University"},{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"McDonald","sequence":"additional","affiliation":[{"name":"Emory University"},{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan J","family":"Beitler","sequence":"additional","affiliation":[{"name":"Emory University"},{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walter J","family":"Curran","sequence":"additional","affiliation":[{"name":"Emory University"},{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Zhou","sequence":"additional","affiliation":[{"name":"Emory University"},{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tian","family":"Liu","sequence":"additional","affiliation":[{"name":"Emory University"},{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9023-5855","authenticated-orcid":false,"given":"Xiaofeng","family":"Yang","sequence":"additional","affiliation":[{"name":"Emory University"},{"name":"Emory University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2021,2,10]]},"reference":[{"key":"pmbabd953bib1","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.radonc.2007.11.032","type":"journal-article","article-title":"Sensitivity of intensity modulated proton therapy plans to changes in patient weight","volume":"86","author":"Albertini","year":"2008","journal-title":"Radiother. Oncol."},{"key":"pmbabd953bib2","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20190594","type":"journal-article","article-title":"Online daily adaptive proton therapy","volume":"93","author":"Albertini","year":"2020","journal-title":"Br. J. Radiol."},{"key":"pmbabd953bib3","doi-asserted-by":"publisher","first-page":"e265","DOI":"10.1016\/j.ijrobp.2011.03.042","type":"journal-article","article-title":"Cone-beam CT-based delineation of stereotactic lung targets: the influence of image modality and target size on interobserver variability","volume":"82","author":"Altorjai","year":"2012","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbabd953bib4","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1016\/j.radonc.2017.09.028","type":"journal-article","article-title":"The impact of treatment accuracy on proton therapy patient selection for oropharyngeal cancer patients","volume":"125","author":"Arts","year":"2017","journal-title":"Radiother. Oncol."},{"key":"pmbabd953bib5","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaf30b","type":"journal-article","article-title":"Online adaption approaches for intensity modulated proton therapy for head and neck patients based on cone beam CTs and Monte Carlo simulations","volume":"64","author":"Botas","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbabd953bib6","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.semradonc.2009.11.002","type":"journal-article","article-title":"Adaptive radiotherapy of head and neck cancer","volume":"20","author":"Castadot","year":"2010","journal-title":"Semin. Radiat. Oncol."},{"key":"pmbabd953bib7","doi-asserted-by":"publisher","first-page":"3945","DOI":"10.1088\/0031-9155\/57\/12\/3945","type":"journal-article","article-title":"Automatic bladder segmentation on CBCT for multiple plan ART of bladder cancer using a patient-specific bladder model","volume":"57","author":"Chai","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbabd953bib8","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.radonc.2007.06.015","type":"journal-article","article-title":"A study on adaptive IMRT treatment planning using kV cone-beam CT","volume":"85","author":"Ding","year":"2007","journal-title":"Radiother. Oncol."},{"key":"pmbabd953bib9","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1016\/j.radonc.2019.09.028","type":"journal-article","article-title":"Synthetic MRI-aided multi-organ segmentation on male pelvic CT using cycle consistent deep attention network","volume":"141","author":"Dong","year":"2019","journal-title":"Radiother. Oncol."},{"key":"pmbabd953bib10","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.ejmp.2015.01.007","type":"journal-article","article-title":"Validation of a deformable image registration produced by a commercial treatment planning system in head and neck","volume":"31","author":"Garc\u00eda-Moll\u00e1","year":"2015","journal-title":"Phys. Med."},{"key":"pmbabd953bib11","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.radonc.2007.05.010","type":"journal-article","article-title":"Adaptive biological image-guided IMRT with anatomic and functional imaging in pharyngo-laryngeal tumors: impact on target volume delineation and dose distribution using helical tomotherapy","volume":"85","author":"Geets","year":"2007","journal-title":"Radiother. Oncol."},{"key":"pmbabd953bib12","doi-asserted-by":"publisher","first-page":"2088","DOI":"10.1118\/1.3554647","type":"journal-article","article-title":"Deformable planning CT to cone-beam CT image registration in head\u2010and-neck cancer","volume":"38","author":"Hou","year":"2011","journal-title":"Med. Phys."},{"key":"pmbabd953bib13","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1109\/34.232073","type":"journal-article","article-title":"Comparing images using the Hausdorff distance","volume":"15","author":"Huttenlocher","year":"1993","journal-title":"ITPAM"},{"key":"pmbabd953bib14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-62321-3","type":"journal-article","article-title":"Deep learning method for mandibular canal segmentation in dental cone beam computed tomography volumes","volume":"10","author":"Jaskari","year":"2020","journal-title":"Sci. Rep."},{"key":"pmbabd953bib15","first-page":"90","type":"conference-proceedings","article-title":"Robust face detection using the hausdorff distance","author":"Jesorsky","year":"2001"},{"key":"pmbabd953bib16","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1093\/jrr\/rrt093","type":"journal-article","article-title":"Evaluation of various deformable image registration algorithms for thoracic images","volume":"55","author":"Kadoya","year":"2014","journal-title":"J. Radiat. Res."},{"key":"pmbabd953bib17","doi-asserted-by":"publisher","DOI":"10.1118\/1.4769114","type":"journal-article","article-title":"The need for application-based adaptation of deformable image registration","volume":"40","author":"Kirby","year":"2013","journal-title":"Med. Phys."},{"key":"pmbabd953bib18","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1186\/s13014-016-0641-7","type":"journal-article","article-title":"Feasibility of automated proton therapy plan adaptation for head and neck tumors using cone beam CT images","volume":"11","author":"Kurz","year":"2016","journal-title":"Radiat. Oncol."},{"key":"pmbabd953bib19","doi-asserted-by":"publisher","first-page":"1354","DOI":"10.1118\/1.4908223","type":"journal-article","article-title":"Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation","volume":"42","author":"Landry","year":"2015","journal-title":"Med. Phys."},{"key":"pmbabd953bib20","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab4891","type":"journal-article","article-title":"Whole-body PET estimation from low count statistics using cycle-consistent generative adversarial networks","volume":"64","author":"Lei","year":"2019a","journal-title":"Phys. Med. Biol."},{"key":"pmbabd953bib21","author":"Lei","year":"2020","type":"preprint"},{"key":"pmbabd953bib22","doi-asserted-by":"publisher","first-page":"3565","DOI":"10.1002\/mp.13617","type":"journal-article","article-title":"MRI-only based synthetic CT generation using dense cycle consistent generative adversarial networks","volume":"46","author":"Lei","year":"2019b","journal-title":"Med. Phys."},{"key":"pmbabd953bib24","doi-asserted-by":"publisher","first-page":"3194","DOI":"10.1002\/mp.13577","type":"journal-article","article-title":"Ultrasound prostate segmentation based on multidirectional deeply supervised V-Net","volume":"46","author":"Lei","year":"2019c","journal-title":"Med. Phys."},{"key":"pmbabd953bib25","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab63bb","type":"journal-article","article-title":"Male pelvic multi-organ segmentation aided by CBCT-based synthetic MRI","volume":"65","author":"Lei","year":"2019d","journal-title":"Phys. Med. Biol."},{"key":"pmbabd953bib26","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0175906","type":"journal-article","article-title":"Comprehensive evaluation of ten deformable image registration algorithms for contour propagation between CT and cone-beam CT images in adaptive head & neck radiotherapy","volume":"12","author":"Li","year":"2017","journal-title":"PLoS One"},{"key":"pmbabd953bib27","first-page":"2117","type":"conference-proceedings","article-title":"Feature pyramid networks for object detection","author":"Lin","year":"2017"},{"key":"pmbabd953bib28","doi-asserted-by":"publisher","first-page":"2472","DOI":"10.1002\/mp.14121","type":"journal-article","article-title":"CBCT-based synthetic CT generation using deep-attention cycleGAN for pancreatic adaptive radiotherapy","volume":"47","author":"Liu","year":"2020","journal-title":"Med. Phys."},{"key":"pmbabd953bib29","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1118\/1.1350587","type":"journal-article","article-title":"Intensity modulated proton therapy: a clinical example","volume":"28","author":"Lomax","year":"2001","journal-title":"Med. Phys."},{"key":"pmbabd953bib30","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.radonc.2010.11.016","type":"journal-article","article-title":"Feasibility of CBCT-based target and normal structure delineation in prostate cancer radiotherapy: multi-observer and image multi-modality study","volume":"98","author":"Lutgendorf-Caucig","year":"2011","journal-title":"Radiother. Oncol."},{"key":"pmbabd953bib31","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1118\/1.2818738","type":"journal-article","article-title":"Volumetric modulated arc therapy: IMRT in a single gantry arc","volume":"35","author":"Otto","year":"2008","journal-title":"Med. Phys."},{"key":"pmbabd953bib32","doi-asserted-by":"publisher","first-page":"R99","DOI":"10.1088\/0031-9155\/57\/11\/R99","type":"journal-article","article-title":"Range uncertainties in proton therapy and the role of Monte Carlo simulations","volume":"57","author":"Paganetti","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbabd953bib33","doi-asserted-by":"publisher","first-page":"e427","DOI":"10.1016\/j.ijrobp.2012.04.003","type":"journal-article","article-title":"Automatic segmentation and online virtualCT in head-and-neck adaptive radiation therapy","volume":"84","author":"Peroni","year":"2012","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbabd953bib34","author":"Ratko","year":"2014","type":"other"},{"key":"pmbabd953bib35","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.media.2019.01.012","type":"journal-article","article-title":"Attention gated networks: learning to leverage salient regions in medical images","volume":"53","author":"Schlemper","year":"2019","journal-title":"Med. Image Anal."},{"key":"pmbabd953bib36","doi-asserted-by":"publisher","DOI":"10.1118\/1.4865762","type":"journal-article","article-title":"Generic method for automatic bladder segmentation on cone beam CT using a patient-specific bladder shape model","volume":"41","author":"van de Schoot","year":"2014","journal-title":"Med. Phys."},{"key":"pmbabd953bib37","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.radonc.2019.11.021","type":"journal-article","article-title":"Clinical evaluation of a full-image deep segmentation algorithm for the male pelvis on cone-beam CT and CT","volume":"145","author":"Schreier","year":"2020","journal-title":"Radiother. Oncol."},{"key":"pmbabd953bib38","doi-asserted-by":"publisher","first-page":"3","DOI":"10.4103\/0971-6203.58777","type":"journal-article","article-title":"Automated medical image segmentation techniques","volume":"35","author":"Sharma","year":"2010","journal-title":"J. Med. Phys."},{"key":"pmbabd953bib39","doi-asserted-by":"publisher","first-page":"7","DOI":"10.3322\/caac.21590","type":"journal-article","article-title":"Cancer statistics, 2020","volume":"70","author":"Siegel","year":"2020","journal-title":"CA Cancer J. Clin."},{"key":"pmbabd953bib40","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1177\/1533034616662165","type":"journal-article","article-title":"Adaptive radiotherapy for head and neck cancer: implications for clinical and dosimetry outcomes","volume":"16","author":"Surucu","year":"2017","journal-title":"Technol. Cancer Res. Treat."},{"key":"pmbabd953bib41","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/s12880-015-0068-x","type":"journal-article","article-title":"Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool","volume":"15","author":"Taha","year":"2015","journal-title":"BMC Med. Imaging"},{"key":"pmbabd953bib42","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1118\/1.4905050","type":"journal-article","article-title":"Toward adaptive radiotherapy for head and neck patients: uncertainties in dose warping due to the choice of deformable registration algorithm","volume":"42","author":"Veiga","year":"2015","journal-title":"Med. Phys."},{"key":"pmbabd953bib43","doi-asserted-by":"publisher","DOI":"10.1118\/1.4864240","type":"journal-article","article-title":"Toward adaptive radiotherapy for head and neck patients: feasibility study on using CT-to-CBCT deformable registration for \u2018dose of the day\u2019 calculations","volume":"41","author":"Veiga","year":"2014","journal-title":"Med. Phys."},{"key":"pmbabd953bib44","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.radonc.2008.08.017","type":"journal-article","article-title":"The clinical feasibility and effect of online cone beam computer tomography-guided intensity-modulated radiotherapy for nasopharyngeal cancer","volume":"90","author":"Wang","year":"2009","journal-title":"Radiother. Oncol."},{"key":"pmbabd953bib45","author":"Webb","year":"2015","type":"book"},{"key":"pmbabd953bib46","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1097\/PPO.0b013e31821da9d8","type":"journal-article","article-title":"Adaptive radiation therapy: technical components and clinical applications","volume":"17","author":"Wu","year":"2011","journal-title":"Cancer J."},{"key":"pmbabd953bib47","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1002\/acm2.12717","type":"journal-article","article-title":"Quantifying the accuracy of deformable image registration for cone-beam computed tomography with a physical phantom","volume":"20","author":"Wu","year":"2019","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbabd953bib48","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1088\/0031-9155\/42\/1\/008","type":"journal-article","article-title":"Adaptive radiation therapy","volume":"42","author":"Yan","year":"1997","journal-title":"Phys. Med. Biol."},{"key":"pmbabd953bib49","first-page":"2223","type":"conference-proceedings","article-title":"Unpaired image-to-image translation using cycle-consistent adversarial networks","author":"Zhu","year":"2017"},{"key":"pmbabd953bib50","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1109\/42.363096","type":"journal-article","article-title":"Morphometric analysis of white matter lesions in MR images: method and validation","volume":"13","author":"Zijdenbos","year":"1994","journal-title":"IEEE Trans. Med. Imaging"}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:58:18Z","timestamp":1778777898000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abd953"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,10]]},"references-count":49,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021,2,10]]},"published-print":{"date-parts":[[2021,2,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/abd953","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,10]]},"assertion":[{"value":"Head-and-neck organs-at-risk auto-delineation using dual pyramid networks for CBCT-guided adaptive radiotherapy","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-10-08","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-01-07","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-02-10","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}