{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T03:16:18Z","timestamp":1787800578722,"version":"build-2784847793"},"reference-count":48,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2021,2,25]],"date-time":"2021-02-25T00:00:00Z","timestamp":1614211200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,2,25]],"date-time":"2021-02-25T00:00:00Z","timestamp":1614211200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"National Cancer Institute","award":["NCI R01 229178"],"award-info":[{"award-number":["NCI R01 229178"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2021,3,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The high conformality of intensity-modulated proton therapy (IMPT) dose distributions causes treatment plans to be sensitive to geometrical changes during the course of a fractionated treatment. This can be addressed using adaptive proton therapy (APT). One important question in APT is the frequency of adaptations performed during a fractionated treatment, which is related to the question whether plan adaptation has to be done online or offline. The purpose of this work is to investigate the impact of weekly and daily online IMPT plan adaptation on the treatment quality for head and neck patients. A cohort of ten head and neck patients with daily acquired cone-beam CT (CBCT) images was evaluated retrospectively. Dose tracking of the IMPT treatment was performed for three scenarios: base plan with no adaptation (BP), weekly online adaptation (OA\n                    <jats:sub>W<\/jats:sub>\n                    ), and daily online adaptation (OA\n                    <jats:sub>D<\/jats:sub>\n                    ). Both adaptation schemes used an in-house developed online APT workflow, performing Monte Carlo dose calculations on scatter-corrected CBCTs. IMPT plan adaptation was achieved by only tuning the weights of a subset of beamlets, based on deformable image registration from the planning CT to each CBCT. Although OA\n                    <jats:sub>D<\/jats:sub>\n                    mitigated random delivery errors more effectively than OA\n                    <jats:sub>W<\/jats:sub>\n                    on a fraction per fraction basis, both OA\n                    <jats:sub>W<\/jats:sub>\n                    and OA\n                    <jats:sub>D<\/jats:sub>\n                    achieved the clinical goals for all ten patients, while BP failed for six cases. In the high-risk CTV, accumulated values of\n                    <jats:italic>D<\/jats:italic>\n                    <jats:sub>98%<\/jats:sub>\n                    ranged between 97.15% and 99.73% of the prescription dose for OA\n                    <jats:sub>D<\/jats:sub>\n                    , with a median of 98.07%. For OA\n                    <jats:sub>W<\/jats:sub>\n                    , values between 95.02% and 99.26% were obtained, with a median of 97.61% of the prescription dose. Otherwise, the dose to most organs at risk was similar for all three scenarios. Globally, our results suggest that OA\n                    <jats:sub>W<\/jats:sub>\n                    could be used as an alternative approach to OA\n                    <jats:sub>D<\/jats:sub>\n                    for most patients in order to reduce the clinical workload.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/abe050","type":"journal-article","created":{"date-parts":[[2021,1,27]],"date-time":"2021-01-27T17:15:26Z","timestamp":1611767726000},"page":"055023","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":56,"title":["Comparison of weekly and daily online adaptation for head and neck intensity-modulated proton therapy"],"prefix":"10.1088","volume":"66","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9409-8680","authenticated-orcid":false,"given":"Mislav","family":"Bobi\u0107","sequence":"first","affiliation":[{"name":"Massachusetts General Hospital"},{"name":"ETH Z\u00fcrich, Z\u00fcrich,"},{"name":"Harvard Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8715-8235","authenticated-orcid":false,"given":"Arthur","family":"Lalonde","sequence":"additional","affiliation":[{"name":"Massachusetts General Hospital"},{"name":"Harvard Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory C","family":"Sharp","sequence":"additional","affiliation":[{"name":"Massachusetts General Hospital"},{"name":"Harvard Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clemens","family":"Grassberger","sequence":"additional","affiliation":[{"name":"Massachusetts General Hospital"},{"name":"Harvard Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joost M","family":"Verburg","sequence":"additional","affiliation":[{"name":"Massachusetts General Hospital"},{"name":"Harvard Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian A","family":"Winey","sequence":"additional","affiliation":[{"name":"Massachusetts General Hospital"},{"name":"Harvard Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antony J","family":"Lomax","sequence":"additional","affiliation":[{"name":"ETH Z\u00fcrich, Z\u00fcrich,"},{"name":"Paul Scherrer Institute, Villigen,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harald","family":"Paganetti","sequence":"additional","affiliation":[{"name":"Massachusetts General Hospital"},{"name":"Harvard Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2021,2,25]]},"reference":[{"key":"pmbabe050bib1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20190594","type":"journal-article","article-title":"Online daily adaptive proton therapy","volume":"93","author":"Albertini","year":"2020","journal-title":"Br. J. Radiol."},{"key":"pmbabe050bib2","doi-asserted-by":"publisher","first-page":"6589","DOI":"10.1118\/1.4933245","type":"journal-article","article-title":"Comparison of organ\u2010at\u2010risk sparing and plan robustness for spot\u2010scanning proton therapy and volumetric modulated arc photon therapy in head\u2010and\u2010neck cancer","volume":"42","author":"Barten","year":"2015","journal-title":"Med. Phys."},{"key":"pmbabe050bib3","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1067\/mhn.2001.120428","type":"journal-article","article-title":"Predictors of weight loss during radiation therapy","volume":"125","author":"Beaver","year":"2001","journal-title":"Otolaryngol.\u2013Head Neck Surg."},{"key":"pmbabe050bib4","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaba8c","type":"journal-article","article-title":"Feasibility of online IMPT adaptation using fast, automatic and robust dose restoration","volume":"63","author":"Bernatowicz","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib5","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.radonc.2016.05.022","type":"journal-article","article-title":"Intensity-modulated proton beam therapy (IMPT) versus intensity-modulated photon therapy (IMRT) for patients with oropharynx cancer\u2014a case matched analysis","volume":"120","author":"Blanchard","year":"2016","journal-title":"Radiother. Oncol."},{"key":"pmbabe050bib6","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaf30b","type":"journal-article","article-title":"Online adaption approaches for intensity modulated proton therapy for head and neck patients based on cone beam CTs and Monte Carlo simulations","volume":"64","author":"Botas","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib7","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1088\/0031-9155\/57\/3\/591","type":"journal-article","article-title":"Including robustness in multi-criteria optimization for intensity-modulated proton therapy","volume":"57","author":"Chen","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib8","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.3109\/0284186X.2010.500304","type":"journal-article","article-title":"Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer","volume":"49","author":"Elstr\u00f8m","year":"2010","journal-title":"Acta Oncol."},{"key":"pmbabe050bib9","doi-asserted-by":"publisher","first-page":"2257","DOI":"10.1088\/0031-9155\/60\/6\/2257","type":"journal-article","article-title":"Validation of a GPU-based Monte Carlo code (gPMC) for proton radiation therapy: clinical cases study","volume":"60","author":"Giantsoudi","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib10","doi-asserted-by":"publisher","first-page":"1166","DOI":"10.3109\/0284186X.2015.1028590","type":"journal-article","article-title":"ART for head and neck patients: on the difference between VMAT and IMPT","volume":"54","author":"G\u00f3ra","year":"2015","journal-title":"Acta Oncol."},{"key":"pmbabe050bib11","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1016\/j.ijrobp.2014.02.023","type":"journal-article","article-title":"Quantification of proton dose calculation accuracy in the lung","volume":"89","author":"Grassberger","year":"2014","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbabe050bib12","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20170266","type":"journal-article","article-title":"A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance","volume":"90","author":"Hua","year":"2017","journal-title":"Br. J. Radiol."},{"key":"pmbabe050bib13","doi-asserted-by":"publisher","first-page":"7017","DOI":"10.1088\/0031-9155\/56\/22\/002","type":"journal-article","article-title":"GPU-based fast Monte Carlo simulation for radiotherapy dose calculation","volume":"56","author":"Jia","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib14","doi-asserted-by":"publisher","first-page":"7783","DOI":"10.1088\/0031-9155\/57\/23\/7783","type":"journal-article","article-title":"GPU-based fast Monte Carlo dose calculation for proton therapy","volume":"57","author":"Jia","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib15","doi-asserted-by":"publisher","first-page":"1651","DOI":"10.3109\/0284186X.2015.1061206","type":"journal-article","article-title":"Comparing cone-beam CT intensity correction methods for dose recalculation in adaptive intensity-modulated photon and proton therapy for head and neck cancer","volume":"54","author":"Kurz","year":"2015","journal-title":"Acta Oncol."},{"key":"pmbabe050bib16","doi-asserted-by":"publisher","first-page":"5635","DOI":"10.1118\/1.4962933","type":"journal-article","article-title":"Investigating deformable image registration and scatter correction for CBCT-based dose calculation in adaptive IMPT","volume":"43","author":"Kurz","year":"2016a","journal-title":"Med. Phys."},{"key":"pmbabe050bib17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13014-016-0641-7","type":"journal-article","article-title":"Feasibility of automated proton therapy plan adaptation for head and neck tumors using cone beam CT images","volume":"11","author":"Kurz","year":"2016b","journal-title":"Radiat. Oncol."},{"key":"pmbabe050bib18","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab4d8c","type":"journal-article","article-title":"CBCT correction using a cycle-consistent generative adversarial network and unpaired training to enable photon and proton dose calculation","volume":"64","author":"Kurz","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib19","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab9fcb","type":"journal-article","article-title":"Evaluation of CBCT scatter correction using deep convolutional neural networks for head and neck adaptive proton therapy","volume":"65","author":"Lalonde","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib20","doi-asserted-by":"publisher","first-page":"1354","DOI":"10.1118\/1.4908223","type":"journal-article","article-title":"Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation","volume":"42","author":"Landry","year":"2015","journal-title":"Med. Phys."},{"key":"pmbabe050bib21","doi-asserted-by":"publisher","first-page":"e1086","DOI":"10.1002\/mp.12744","type":"journal-article","article-title":"Current state and future applications of radiological image guidance for particle therapy","volume":"45","author":"Landry","year":"2018","journal-title":"Med. Phys."},{"key":"pmbabe050bib22","doi-asserted-by":"publisher","first-page":"e254","DOI":"10.1016\/S1470-2045(17)30179-1","type":"journal-article","article-title":"Proton therapy for head and neck cancer: expanding the therapeutic window","volume":"18","author":"Leeman","year":"2017","journal-title":"Lancet Oncol."},{"key":"pmbabe050bib23","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0175906","type":"journal-article","article-title":"Comprehensive evaluation of ten deformable image registration algorithms for contour propagation between CT and cone-beam CT images in adaptive head & neck radiotherapy","volume":"12","author":"Li","year":"2017","journal-title":"PLoS One"},{"key":"pmbabe050bib24","doi-asserted-by":"publisher","first-page":"S443","DOI":"10.1016\/j.ijrobp.2013.06.1168","type":"journal-article","article-title":"Effectiveness of robust optimization in oropharynx IMPT planning","volume":"87","author":"Liu","year":"2013","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbabe050bib25","doi-asserted-by":"publisher","first-page":"1027","DOI":"10.1088\/0031-9155\/53\/4\/014","type":"journal-article","article-title":"Intensity modulated proton therapy and its sensitivity to treatment uncertainties: I. The potential effects of calculational uncertainties","volume":"53","author":"Lomax","year":"2008a","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib26","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1088\/0031-9155\/53\/4\/015","type":"journal-article","article-title":"Intensity modulated proton therapy and its sensitivity to treatment uncertainties: II. The potential effects of inter-fraction and inter-field motions","volume":"53","author":"Lomax","year":"2008b","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib27","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1016\/S0360-3016(00)00494-6","type":"journal-article","article-title":"Optimizing radiotherapy of orbital and paraorbital tumors: intensity-modulated x-ray beams vs intensity-modulated proton beams","volume":"47","author":"Miralbell","year":"2000","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbabe050bib28","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.oraloncology.2018.11.015","type":"journal-article","article-title":"Intensity modulated proton therapy (IMPT)\u2014the future of IMRT for head and neck cancer","volume":"88","author":"Moreno","year":"2019","journal-title":"Oral Oncol."},{"key":"pmbabe050bib29","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1016\/j.ejmp.2015.02.007","type":"journal-article","article-title":"Impact of interfractional changes in head and neck cancer patients on the delivered dose in intensity modulated radiotherapy with protons and photons","volume":"31","author":"M\u00fcller","year":"2015","journal-title":"Phys. Med."},{"key":"pmbabe050bib30","doi-asserted-by":"publisher","first-page":"1423","DOI":"10.1080\/0284186X.2019.1641217","type":"journal-article","article-title":"Daily adaptive proton therapy\u2014the key to innovative planning approaches for paranasal cancer treatments","volume":"58","author":"Nenoff","year":"2019","journal-title":"Acta Oncol."},{"key":"pmbabe050bib31","doi-asserted-by":"publisher","first-page":"R99","DOI":"10.1088\/0031-9155\/57\/11\/R99","type":"journal-article","article-title":"Range uncertainties in proton therapy and the role of Monte Carlo simulations","volume":"57","author":"Paganetti","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib32","doi-asserted-by":"publisher","first-page":"4449","DOI":"10.1118\/1.4923179","type":"journal-article","article-title":"Proton dose calculation on scatter-corrected CBCT image: feasibility study for adaptive proton therapy","volume":"42","author":"Park","year":"2015","journal-title":"Med. Phys."},{"key":"pmbabe050bib33","doi-asserted-by":"publisher","first-page":"7347","DOI":"10.1088\/0031-9155\/61\/20\/7347","type":"journal-article","article-title":"Recent developments and comprehensive evaluations of a GPU-based Monte Carlo package for proton therapy","volume":"61","author":"Qin","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib34","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1016\/j.ijrobp.2015.04.006","type":"journal-article","article-title":"Assessing the clinical impact of approximations in analytical dose calculations for proton therapy","volume":"92","author":"Schuemann","year":"2015","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbabe050bib35","article-title":"Plastimatch 1.6\u2014current capabilities and future directions","author":"Shackleford","year":"2012","type":"conference-proceedings"},{"key":"pmbabe050bib36","article-title":"Plastimatch\u2014an open source software suite for radiotherapy image processing","author":"Sharp","year":"2010","type":"conference-proceedings"},{"key":"pmbabe050bib37","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1016\/j.radonc.2011.05.028","type":"journal-article","article-title":"Comparison of intensity-modulated radiotherapy, adaptive radiotherapy, proton radiotherapy, and adaptive proton radiotherapy for treatment of locally advanced head and neck cancer","volume":"101","author":"Simone","year":"2011","journal-title":"Radiother. Oncol."},{"key":"pmbabe050bib38","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1002\/acm2.12189","type":"journal-article","article-title":"Potential proton and photon dose degradation in advanced head and neck cancer patients by intratherapy changes","volume":"18","author":"St\u00fctzer","year":"2017","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbabe050bib39","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.radonc.2016.04.002","type":"journal-article","article-title":"Effects of anatomical changes on pencil beam scanning proton plans in locally advanced NSCLC patients","volume":"120","author":"Szeto","year":"2016","journal-title":"Radiother. Oncol."},{"key":"pmbabe050bib40","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abb1d6","type":"journal-article","article-title":"Comparison of the suitability of CBCT- and MR-based synthetic CTs for daily adaptive proton therapy in head and neck patients","volume":"65","author":"Thummerer","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib41","doi-asserted-by":"publisher","first-page":"2779","DOI":"10.1088\/0031-9155\/50\/12\/004","type":"journal-article","article-title":"Temporo-spatial IMRT optimization: concepts, implementation and initial results","volume":"50","author":"Trofimov","year":"2005","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib42","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aae659","type":"journal-article","article-title":"Robust radiotherapy planning","volume":"63","author":"Unkelbach","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib43","doi-asserted-by":"publisher","first-page":"404","DOI":"10.14338\/IJPT-14-00024.1","type":"journal-article","article-title":"Cone-beam computed tomography and deformable registration-based \u2018dose of the day\u2019 calculations for adaptive proton therapy","volume":"2","author":"Veiga","year":"2015","journal-title":"Int. J. Part. Ther."},{"key":"pmbabe050bib44","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/j.ijrobp.2016.01.055","type":"journal-article","article-title":"First clinical investigation of cone beam computed tomography and deformable registration for adaptive proton therapy for lung cancer","volume":"95","author":"Veiga","year":"2016","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbabe050bib45","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.radonc.2016.04.038","type":"journal-article","article-title":"The price of robustness; impact of worst-case optimization on organ-at-risk dose and complication probability in intensity-modulated proton therapy for oropharyngeal cancer patients","volume":"120","author":"van de Water","year":"2016","journal-title":"Radiother. Oncol."},{"key":"pmbabe050bib46","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa9c1c","type":"journal-article","article-title":"Anatomical robust optimization to account for nasal cavity filling variation during intensity-modulated proton therapy: a comparison with conventional and adaptive planning strategies","volume":"63","author":"van de Water","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbabe050bib47","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0152477","type":"journal-article","article-title":"Robust intensity modulated proton therapy (IMPT) increases estimated clinical benefit in head and neck cancer patients","volume":"11","author":"van Dijk","year":"2016","journal-title":"PLoS One"},{"key":"pmbabe050bib48","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1016\/j.ijrobp.2009.04.047","type":"journal-article","article-title":"Adaptive replanning strategies accounting for shrinkage in head and neck IMRT","volume":"75","author":"Wu","year":"2009","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:49:39Z","timestamp":1778777379000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/abe050"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,25]]},"references-count":48,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2021,2,25]]},"published-print":{"date-parts":[[2021,3,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/abe050","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,25]]},"assertion":[{"value":"Comparison of weekly and daily online adaptation for head and neck intensity-modulated proton therapy","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-11-20","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-01-27","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-02-25","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}