{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T18:08:08Z","timestamp":1778782088960,"version":"3.51.4"},"reference-count":52,"publisher":"IOP Publishing","issue":"8","license":[{"start":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T00:00:00Z","timestamp":1649030400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T00:00:00Z","timestamp":1649030400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100021130","name":"Federal Ministry for Economic Affairs and Climate Action","doi-asserted-by":"crossref","award":["Metrology for Artificial Intelligence in Medicine"],"award-info":[{"award-number":["Metrology for Artificial Intelligence in Medicine"]}],"id":[{"id":"10.13039\/100021130","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100001659","name":"German Research Foundation","doi-asserted-by":"crossref","award":["LO 2266\/1-2."],"award-info":[{"award-number":["LO 2266\/1-2."]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2022,4,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . To investigate the feasibility to train artificial neural networks (NN) to recover lateral dose profiles from detector measurements in a magnetic field.\n                    <jats:italic>Approach<\/jats:italic>\n                    . A novel framework based on a mathematical convolution model has been proposed to generate measurement-less training dataset. 2D dose deposition kernels and detector lateral fluence response functions of two air-filled ionization chambers and two diode-type detectors have been simulated without magnetic field and for magnetic field\n                    <jats:italic>B<\/jats:italic>\n                    \u00a0=\u00a00.35 and 1.5 T. Using these convolution kernels, training dataset consisting pairs of dose profiles\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mi>D<\/mml:mi>\n                        <mml:mrow>\n                          <mml:mfenced close=\")\" open=\"(\" separators=\"\">\n                            <mml:mrow>\n                              <mml:mi>x<\/mml:mi>\n                              <mml:mo>,<\/mml:mo>\n                              <mml:mi>y<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:mfenced>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    and signal profiles\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mi>M<\/mml:mi>\n                        <mml:mrow>\n                          <mml:mfenced close=\")\" open=\"(\" separators=\"\">\n                            <mml:mrow>\n                              <mml:mi>x<\/mml:mi>\n                              <mml:mo>,<\/mml:mo>\n                              <mml:mi>y<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:mfenced>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    were computed for a total of 108 2D photon fluence profiles\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mi>\u03c8<\/mml:mi>\n                        <mml:mrow>\n                          <mml:mo stretchy=\"false\">(<\/mml:mo>\n                          <mml:mi>x<\/mml:mi>\n                          <mml:mo>,<\/mml:mo>\n                          <mml:mi>y<\/mml:mi>\n                          <mml:mo stretchy=\"false\">)<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    (80% training\/20% validation). The NN were tested using three independent datasets, where the second test dataset has been obtained from simulations using realistic phase space files of clinical linear accelerator and the third test dataset was measured at a conventional linac equipped with electromagnets. Main\n                    <jats:italic>results<\/jats:italic>\n                    . The convolution kernels show magnetic field dependence due to the influence of the Lorentz force on the electron transport in the water phantom and detectors. The NN show good performance during training and validation with mean square error reaching a value of 1e-6 or smaller. The corresponding correlation coefficients\n                    <jats:italic>R<\/jats:italic>\n                    reached the value of 1 for all models indicating an excellent agreement between expected\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mi>D<\/mml:mi>\n                        <mml:mrow>\n                          <mml:mfenced close=\")\" open=\"(\" separators=\"\">\n                            <mml:mrow>\n                              <mml:mi>x<\/mml:mi>\n                              <mml:mo>,<\/mml:mo>\n                              <mml:mi>y<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:mfenced>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    and predicted\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:mrow>\n                            <mml:mi>D<\/mml:mi>\n                          <\/mml:mrow>\n                          <mml:mrow>\n                            <mml:mi mathvariant=\"normal\">pred<\/mml:mi>\n                          <\/mml:mrow>\n                        <\/mml:msub>\n                        <mml:mrow>\n                          <mml:mfenced close=\")\" open=\"(\" separators=\"\">\n                            <mml:mrow>\n                              <mml:mi>x<\/mml:mi>\n                              <mml:mo>,<\/mml:mo>\n                              <mml:mi>y<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:mfenced>\n                        <\/mml:mrow>\n                        <mml:mo>.<\/mml:mo>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    The comparisons between\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mi>D<\/mml:mi>\n                        <mml:mrow>\n                          <mml:mfenced close=\")\" open=\"(\" separators=\"\">\n                            <mml:mrow>\n                              <mml:mi>x<\/mml:mi>\n                              <mml:mo>,<\/mml:mo>\n                              <mml:mi>y<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:mfenced>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:mrow>\n                            <mml:mi>D<\/mml:mi>\n                          <\/mml:mrow>\n                          <mml:mrow>\n                            <mml:mi mathvariant=\"normal\">pred<\/mml:mi>\n                          <\/mml:mrow>\n                        <\/mml:msub>\n                        <mml:mrow>\n                          <mml:mfenced close=\")\" open=\"(\" separators=\"\">\n                            <mml:mrow>\n                              <mml:mi>x<\/mml:mi>\n                              <mml:mo>,<\/mml:mo>\n                              <mml:mi>y<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:mfenced>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    using the three test datasets resulted in gamma indices (1 mm\/1% global)\u00a0&lt;1 for all evaluated data points.\n                    <jats:italic>Significance<\/jats:italic>\n                    . Two verification approaches have been proposed to warrant the mathematical consistencies of the NN outputs. Besides offering a correction strategy not existed so far for relative dosimetry in a magnetic field, this work could help to raise awareness and to improve understanding on the distortion of detector\u2019s signal profiles by a magnetic field.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ac5bfa","type":"journal-article","created":{"date-parts":[[2022,3,9]],"date-time":"2022-03-09T17:19:39Z","timestamp":1646846379000},"page":"085006","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Model-based machine learning for the recovery of lateral dose profiles of small photon fields in magnetic field"],"prefix":"10.1088","volume":"67","author":[{"given":"Hui Khee","family":"Looe","sequence":"first","affiliation":[{"name":"Carl von Ossietzky University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isabel","family":"Blum","sequence":"additional","affiliation":[{"name":"Carl von Ossietzky University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3903-4817","authenticated-orcid":true,"given":"Ann-Britt","family":"Sch\u00f6nfeld","sequence":"additional","affiliation":[{"name":"Physikalisch-Technische Bundesanstalt, PTB, Braunschweig,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8473-2668","authenticated-orcid":true,"given":"Tuba","family":"Tekin","sequence":"additional","affiliation":[{"name":"Carl von Ossietzky University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bj\u00f6rn","family":"Delfs","sequence":"additional","affiliation":[{"name":"Carl von Ossietzky University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bj\u00f6rn","family":"Poppe","sequence":"additional","affiliation":[{"name":"Carl von Ossietzky University"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2022,4,4]]},"reference":[{"key":"pmbac5bfabib1","doi-asserted-by":"publisher","first-page":"3643","DOI":"10.1088\/0031-9155\/47\/20\/306","type":"journal-article","article-title":"Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams","volume":"47","author":"Bednarz","year":"2002","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib2","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac0f2e","type":"journal-article","article-title":"The dose response of PTW microDiamond and microSilicon in transverse magnetic field under small field conditions","volume":"66","author":"Blum","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib3","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.zemedi.2012.05.001","type":"journal-article","article-title":"Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy","volume":"22","author":"Chofor","year":"2012","journal-title":"Z. Med. Phys."},{"key":"pmbac5bfabib4","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.zemedi.2013.04.001","type":"journal-article","article-title":"Supplementary values of the dosimetric parameters kNR and Em for various types of detectors in 6 and 15 MV photon fields","volume":"24","author":"Chofor","year":"2014","journal-title":"Z. Med. Phys."},{"key":"pmbac5bfabib5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13014-019-1308-y","type":"journal-article","article-title":"MR-guidance in clinical reality: current treatment challenges and future perspectives","volume":"14","author":"Corradini","year":"2019","journal-title":"Rad Oncol."},{"key":"pmbac5bfabib53","doi-asserted-by":"publisher","first-page":"6592","DOI":"10.1118\/1.3658572","type":"journal-article","article-title":"Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors","volume":"38","author":"Cranmer-Sargison","year":"2011","journal-title":"Med Phys."},{"key":"pmbac5bfabib9","doi-asserted-by":"publisher","first-page":"4572","DOI":"10.1002\/mp.14994","type":"journal-article","article-title":"The role of the construction and sensitive volume of a compact ionization chamber on its magnetic field-dependent dose response","volume":"48","author":"Delfs","year":"2021","journal-title":"Med. Phys."},{"key":"pmbac5bfabib8","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aadd3d","type":"journal-article","article-title":"The 1D lateral dose response functions of photon-dosimetry detectors in magnetic fields -measurement and Monte-Carlo simulation","volume":"63","author":"Delfs","year":"2018b","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib7","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa9bd5","type":"journal-article","article-title":"Magnetic fields are causing small, but significant changes of the radiochromic EBT3 film response to 6 MV photons","volume":"63","author":"Delfs","year":"2018a","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/1361-6560\/ab9efe","type":"journal-article","article-title":"Reference dosimetry in MRI-linacs: evaluation of available protocols and data to establish a Code of Practice","volume":"66","author":"de Pooter","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib12","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/0029-554X(68)90470-9","type":"journal-article","article-title":"Ein plastik-szintillationspektrometer f\u00fcr elektronen im energiebereich 2 bis 20 MeV","volume":"58","author":"Feist","year":"1968","journal-title":"Nucl. Instrum. Methods"},{"key":"pmbac5bfabib13","doi-asserted-by":"publisher","first-page":"2901","DOI":"10.1088\/0031-9155\/58\/9\/2901","type":"journal-article","article-title":"Using cavity theory to describe the dependence on detector density of dosimeter response in non-equilibrium small fields","volume":"58","author":"Fenwick","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib14","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.addr.2016.11.005","type":"journal-article","article-title":"Stereotactic ablative body radiosurgery (SABR) or Stereotactic body radiation therapy (SBRT)","volume":"109","author":"Folkert","year":"2017","journal-title":"Adv. Drug Delivery Rev."},{"key":"pmbac5bfabib15","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1088\/1361-6560\/aa5610","type":"journal-article","article-title":"Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors","volume":"62","author":"Francescon","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib16","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab6154","type":"journal-article","article-title":"Small field dosimetry correction factors for circular and MLC shaped fields with the CyberKnife M6 System: evaluation of the PTW 60023 microSilicon detector","volume":"65","author":"Francescon","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib17","first-page":"249","type":"book","article-title":"Convolutions and deconvolutions in radiation dosimetry","author":"Harder","year":"2014"},{"key":"pmbac5bfabib18","doi-asserted-by":"publisher","first-page":"3636","DOI":"10.1118\/1.2128086","type":"journal-article","article-title":"Determination of penumbral widths from ion chamber measurements","volume":"32","author":"Herrup","year":"2005","journal-title":"Med. Phys."},{"key":"pmbac5bfabib19","doi-asserted-by":"publisher","first-page":"e138","DOI":"10.1016\/S2589-7500(20)30003-0","type":"journal-article","article-title":"Changes in cancer detection and false-positive recall in mammography using artificial intelligence: a retrospective, multireader study","volume":"2","author":"Kim","year":"2020","journal-title":"Lancet Digital Health"},{"key":"pmbac5bfabib20","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abd66d","type":"journal-article","article-title":"Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac","volume":"66","author":"Kontaxis","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib21","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1118\/1.1544678","type":"journal-article","article-title":"The volume effect of detectors in the dosimetry of small fields used in IMRT","volume":"30","author":"Laub","year":"2003","journal-title":"Med. Phys."},{"key":"pmbac5bfabib22","doi-asserted-by":"publisher","first-page":"5586","DOI":"10.1002\/mp.13230","type":"journal-article","article-title":"Feasibility of photon beam profile deconvolution using a neural network","volume":"45","author":"Liu","year":"2018","journal-title":"Med. Phys."},{"key":"pmbac5bfabib27","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aab50c","type":"journal-article","article-title":"2D convolution kernels of ionization chambers used for photon-beam dosimetry in magnetic fields: the advantage of small over large chamber dimensions","volume":"63","author":"Looe","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib26","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa9b46","type":"journal-article","article-title":"The \u2018cutting away\u2019of potential secondary electron tracks explains the effects of beam size and detector wall density in small-field photon dosimetry","volume":"63","author":"Looe","year":"2017a","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib25","doi-asserted-by":"publisher","first-page":"5131","DOI":"10.1088\/1361-6560\/aa6ca0","type":"journal-article","article-title":"Magnetic field influences on the lateral dose response functions of photon-beam detectors: MC study of wall-less water-filled detectors with various densities","volume":"62","author":"Looe","year":"2017b","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib24","doi-asserted-by":"publisher","first-page":"6585","DOI":"10.1088\/0031-9155\/60\/16\/6585","type":"journal-article","article-title":"Understanding the lateral dose response functions of high-resolution photon detectors by reverse Monte Carlo and deconvolution analysis","volume":"60","author":"Looe","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib23","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.zemedi.2012.12.010","type":"journal-article","article-title":"The dose response functions of ionization chambers in photon dosimetry - Gaussian or non-Gaussian\u00a0?\u00a0","volume":"23","author":"Looe","year":"2013","journal-title":"Z. Med. Phys."},{"key":"pmbac5bfabib28","doi-asserted-by":"publisher","first-page":"4447","DOI":"10.1118\/1.4954318","type":"journal-article","article-title":"Charged particle transport in magnetic fields in EGSnrc","volume":"43","author":"Malkov","year":"2016","journal-title":"Med. Phys."},{"key":"pmbac5bfabib54","doi-asserted-by":"publisher","first-page":"2993","DOI":"10.1088\/0031-9155\/54\/10\/002","type":"journal-article","article-title":"Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber","volume":"54","author":"Meijsing","year":"2009","journal-title":"Phys Med Biol."},{"key":"pmbac5bfabib29","doi-asserted-by":"publisher","first-page":"111702","DOI":"10.1118\/1.4895827","type":"journal-article","article-title":"Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector","volume":"41","author":"Morales","year":"2014","journal-title":"Med. Phys."},{"key":"pmbac5bfabib30","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1002\/acm2.12865","type":"journal-article","article-title":"Evaluation of a neural network-based photon beam profile deconvolution method","volume":"21","author":"Mund","year":"2020","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbac5bfabib31","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.semradonc.2014.02.008","type":"journal-article","article-title":"The ViewRay system: magnetic resonance-guided and controlled radiotherapy","volume":"24","author":"Mutic","year":"2014","journal-title":"Semin. Radiat. Oncol."},{"key":"pmbac5bfabib32","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1002\/mp.12699","type":"journal-article","article-title":"Relative dosimetry with an MR\u2010linac: response of ion chambers, diamond, and diode detectors for off\u2010axis, depth dose, and output factor measurements","volume":"45","author":"O\u2019Brien","year":"2018","journal-title":"Med. Phys."},{"key":"pmbac5bfabib33","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1016\/j.ijrobp.2018.06.002","type":"journal-article","article-title":"Role of daily plan adaptation in MR-guided stereotactic ablative radiation therapy for adrenal metastases","volume":"102","author":"Palacios","year":"2018","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbac5bfabib34","doi-asserted-by":"publisher","first-page":"3700","DOI":"10.1118\/1.2349691","type":"journal-article","article-title":"Experimental determination of the effect of detector size on profile measurements in narrow photon beams","volume":"33","author":"Pappas","year":"2006","journal-title":"Med. Phys."},{"key":"pmbac5bfabib35","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aac4f2","type":"journal-article","article-title":"Ionization chamber correction factors for MR-linacs","volume":"63","author":"Pojtinger","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib36","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.zemedi.2017.07.006","type":"journal-article","article-title":"The output factor correction as function of the photon beam field size - direct measurement and calculation from the lateral dose response functions of gas-filled and solid detectors","volume":"28","author":"Poppinga","year":"2018","journal-title":"Z. Med. Phys."},{"key":"pmbac5bfabib37","doi-asserted-by":"publisher","first-page":"N229","DOI":"10.1088\/0031-9155\/54\/12\/N01","type":"journal-article","article-title":"Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept","volume":"54","author":"Raaymakers","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib38","doi-asserted-by":"publisher","DOI":"10.1118\/1.4794496","type":"journal-article","article-title":"Dose response of selected ion chambers in applied homogeneous transverse and longitudinal magnetic fields","volume":"40","author":"Reynolds","year":"2013","journal-title":"Med. Phys."},{"key":"pmbac5bfabib39","doi-asserted-by":"publisher","DOI":"10.1118\/1.4893276","type":"journal-article","article-title":"Dose response of selected solid state detectors in applied homogeneous transverse and longitudinal magnetic fields","volume":"41","author":"Reynolds","year":"2014","journal-title":"Med. Phys."},{"key":"pmbac5bfabib40","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1038\/s41597-020-00715-8","type":"journal-article","article-title":"CT-ORG, a new dataset for multiple organ segmentation in computed tomography","volume":"7","author":"Rister","year":"2020","journal-title":"Sci Data"},{"key":"pmbac5bfabib42","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1002\/acm2.13447","type":"journal-article","article-title":"Corrections of photon beam profiles of small fields measured with ionization chambers using a three-layer neural network","volume":"22","author":"Sch\u00f6nfeld","year":"2021","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbac5bfabib41","doi-asserted-by":"publisher","first-page":"4257","DOI":"10.1002\/mp.13710","type":"journal-article","article-title":"Characterization of the new microSilicon diode detector","volume":"46","author":"Sch\u00f6nfeld","year":"2019","journal-title":"Med. Phys."},{"key":"pmbac5bfabib43","doi-asserted-by":"publisher","first-page":"4461","DOI":"10.1088\/0031-9155\/57\/14\/4461","type":"journal-article","article-title":"Characterizing the influence of detector density on dosimeter response in non-equilibrium small photon fields","volume":"57","author":"Scott","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib44","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1186\/s40537-019-0197-0","type":"journal-article","article-title":"A survey on image data augmentation for deep learning","volume":"6","author":"Shorten","year":"2019","journal-title":"J. Big Data"},{"key":"pmbac5bfabib45","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aab56c","type":"journal-article","article-title":"Spectral characterization of plastic scintillation detector response as a function of magnetic field strength","volume":"63","author":"Simiele","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib46","doi-asserted-by":"publisher","first-page":"261","DOI":"10.2307\/3570921","type":"journal-article","article-title":"Iterative response correction for a scintillation spectrometer","volume":"14","author":"Skarsgard","year":"1961","journal-title":"Radiat. Res."},{"key":"pmbac5bfabib47","doi-asserted-by":"publisher","first-page":"6708","DOI":"10.1088\/1361-6560\/aa7ae4","type":"journal-article","article-title":"Radiation dosimetry in magnetic fields with Farmer-type ionization chambers: determination of magnetic field correction factors for different magnetic field strengths and field orientations","volume":"62","author":"Spindeldreier","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"pmbac5bfabib48","doi-asserted-by":"publisher","first-page":"6509","DOI":"10.1002\/mp.14535","type":"journal-article","article-title":"The dose response of high-resolution diode-type detectors and the role of their structural components in strong magnetic field","volume":"47","author":"Tekin","year":"2020","journal-title":"Med. Phys."},{"key":"pmbac5bfabib50","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1038\/nrclinonc.2012.203","type":"journal-article","article-title":"Past, present, and future of radiotherapy for the benefit of patients","volume":"10","author":"Thariat","year":"2012","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"pmbac5bfabib49","doi-asserted-by":"publisher","first-page":"2847","DOI":"10.1200\/JCO.2014.55.4675","type":"journal-article","article-title":"Emergence of stereotactic body radiation therapy and its impact on current and future clinical practice","volume":"32","author":"Timmerman","year":"2014","journal-title":"J. Clin. Oncol."},{"key":"pmbac5bfabib51","doi-asserted-by":"publisher","DOI":"10.1118\/1.4812687","type":"journal-article","article-title":"Detector density and small field dosimetry: integral versus point dose measurement schemes","volume":"40","author":"Underwood","year":"2013","journal-title":"Med. Phys."},{"key":"pmbac5bfabib52","doi-asserted-by":"publisher","first-page":"3165","DOI":"10.1002\/mp.14149","type":"journal-article","article-title":"Small field output correction factors of the microSilicon detector and a deeper understanding of their origin by quantifying perturbation factors","volume":"47","author":"Weber","year":"2020","journal-title":"Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:12:54Z","timestamp":1778778774000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ac5bfa"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,4]]},"references-count":52,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2022,4,4]]},"published-print":{"date-parts":[[2022,4,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ac5bfa","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,4]]},"assertion":[{"value":"Model-based machine learning for the recovery of lateral dose profiles of small photon fields in magnetic field","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2021-10-22","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-03-09","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-04-04","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}