{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:17:31Z","timestamp":1778779051232,"version":"3.51.4"},"reference-count":45,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2023,1,13]],"date-time":"2023-01-13T00:00:00Z","timestamp":1673568000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2023,1,13]],"date-time":"2023-01-13T00:00:00Z","timestamp":1673568000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2023,1,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . Polycrystalline mercuric iodide photoconductive converters fabricated using particle-in-binder techniques (PIB HgI\n                    <jats:sub>2<\/jats:sub>\n                    ) provide significantly more detected charge per x-ray interaction than from a-Se and CsI:Tl converters commonly used with active matrix flat-panel imagers (AMFPIs). This enhanced sensitivity makes PIB HgI\n                    <jats:sub>2<\/jats:sub>\n                    an interesting candidate for applications involving low x-ray exposures\u2014since the relatively high levels of additive electronic noise exhibited by AMFPIs incorporating a-Se and CsI:Tl reduce detective quantum efficiency (DQE) performance under such conditions. A theoretical study is reported on an approach for addressing a major challenge impeding practical use of PIB HgI\n                    <jats:sub>2<\/jats:sub>\n                    converters\u2014the high lag exhibited by the material (over 10%) which would lead to undesirable image artifacts in applications involving acquisition of consecutive images such as digital breast tomosynthesis.\n                    <jats:italic>Approach<\/jats:italic>\n                    . Charge transport modeling accounting for the trapping and release of holes (thought to be the primary contributor to lag) was used to examine signal properties, including lag, of pillar-supported Frisch grids embedded in the photoconductor for 100\n                    <jats:italic>\u03bc<\/jats:italic>\n                    m pitch AMFPI pixels. Performance was examined as a function of electrode voltage, grid pitch (center-to-center distance between neighboring grid wires) and the ratio of grid wire width to grid pitch.\n                    <jats:italic>Main results<\/jats:italic>\n                    . Optimum grid designs maximizing suppression of signal generated by hole transport, without significantly affecting the total signal due to electron and hole transport, were identified and MTF was determined. For the most favorable designs, additional modeling was used to determine DQE. The results indicate that, through judicious choice of grid design and operational conditions, first frame lag can be significantly reduced to below 1%\u2014less than the low levels exhibited by a-Se. DQE performance is shown to be largely maintained as exposure decreases\u2014which should help to maintain good image quality.\n                    <jats:italic>Significance<\/jats:italic>\n                    . Substantial reduction of lag in PIB HgI\n                    <jats:sub>2<\/jats:sub>\n                    converters via incorporation of Frisch grids has been demonstrated through modeling.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/aca952","type":"journal-article","created":{"date-parts":[[2023,1,12]],"date-time":"2023-01-12T23:44:07Z","timestamp":1673567047000},"page":"025023","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Minimization of image lag in polycrystalline mercuric iodide converters through incorporation of Frisch grid structures for digital breast tomosynthesis"],"prefix":"10.1088","volume":"68","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5055-7726","authenticated-orcid":false,"given":"Liuxing","family":"Shen","sequence":"first","affiliation":[{"name":"University of Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4052-3733","authenticated-orcid":true,"given":"Larry E","family":"Antonuk","sequence":"additional","affiliation":[{"name":"University of Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youcef","family":"El-Mohri","sequence":"additional","affiliation":[{"name":"University of Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qihua","family":"Zhao","sequence":"additional","affiliation":[{"name":"University of Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2023,1,13]]},"reference":[{"key":"pmbaca952bib1","type":"journal-article","article-title":"Exploration of strategies for implementation of screen-printed mercuric iodide converters in direct detection AMFPIs for digital breast tomosynthesis","volume":"10132","author":"Antonuk","year":"2017","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib2","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1118\/1.598831","type":"journal-article","article-title":"Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications","volume":"27","author":"Antonuk","year":"2000","journal-title":"Med. Phys."},{"key":"pmbaca952bib3","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.3938\/jkps.52.1123","type":"journal-article","article-title":"Properties of polycyrstalline HgI2 films fabricated by using a particle-in-binder method","volume":"52","author":"Cho","year":"2008","journal-title":"J. Korean Phys. Soc."},{"key":"pmbaca952bib4","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1016\/j.ijleo.2018.10.094","type":"journal-article","article-title":"Effective detective quantum efficiency of two detectors in a prototype digital breast tomosynthesis","volume":"178","author":"Choi","year":"2019","journal-title":"Optik\u2014Int. J. Light Electron Opt."},{"key":"pmbaca952bib5","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1118\/1.597401","type":"journal-article","article-title":"A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems","volume":"21","author":"Cunningham","year":"1994","journal-title":"Med. Phys."},{"key":"pmbaca952bib6","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1088\/0031-9155\/53\/5\/011","type":"journal-article","article-title":"Investigation of the signal behavior at diagnostic energies of prototype, direct detection, active matrix, flat-panel imagers incorporating polycrystalline HgI2","volume":"53","author":"Du","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"pmbaca952bib7","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1118\/1.3669486","type":"journal-article","article-title":"Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: application to pulse-height spectroscopy in a-Se","volume":"39","author":"Fang","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaca952bib8","first-page":"2","type":"conference-proceedings","article-title":"Active pixel sensors: are CCD\u2019s Dinosaurs ?","volume":"vol 1900","author":"Fossum","year":"1993"},{"key":"pmbaca952bib9","type":"journal-article","article-title":"Analysis of a new indium gallium zinc oxide (IGZO) detector","volume":"11312","author":"Freestone","year":"2020","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib10","type":"journal-article","volume":"65","author":"Frisch","year":"1944","journal-title":"Br. At. Energy Rep. BR-49"},{"key":"pmbaca952bib11","doi-asserted-by":"publisher","DOI":"10.1063\/1.4807292","type":"journal-article","article-title":"Unipolar time-differential charge sensing in non-dispersive amorphous solids","volume":"113","author":"Goldan","year":"2013","journal-title":"J. Appl. Phys."},{"key":"pmbaca952bib12","doi-asserted-by":"publisher","DOI":"10.1063\/1.4766726","type":"journal-article","article-title":"Unipolar time-differential pulse response with a solid-state Charpak photoconductor","volume":"101","author":"Goldan","year":"2012","journal-title":"Appl. Phys. Lett."},{"key":"pmbaca952bib13","doi-asserted-by":"publisher","first-page":"1812","DOI":"10.1109\/TNS.2004.832691","type":"journal-article","article-title":"Imaging performance of mercuric iodide polycrystalline films","volume":"51","author":"Hartsough","year":"2004","journal-title":"IEEE Trans. Med. Imag."},{"key":"pmbaca952bib14","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/S0168-9002(01)00223-6","type":"journal-article","article-title":"Review of the Shockley\u2013Ramo theorem and its application in semiconductor gamma-ray detectors","volume":"A463","author":"He","year":"2001","journal-title":"Nucl. Instrum. Meth. A"},{"key":"pmbaca952bib15","doi-asserted-by":"publisher","first-page":"2148","DOI":"10.1002\/mp.12222","type":"journal-article","article-title":"Generation and analysis of clinically relevant breast imaging x-ray spectra","volume":"44","author":"Hernandez","year":"2017","journal-title":"Med. Phys."},{"key":"pmbaca952bib16","doi-asserted-by":"publisher","first-page":"1694","DOI":"10.1109\/JSEN.2019.2950319","type":"journal-article","article-title":"Recent developments of amorphous selenium-based x-ray detectors: a review","volume":"20","author":"Huang","year":"2020","journal-title":"IEEE Sens. J."},{"key":"pmbaca952bib17","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1088\/0031-9155\/58\/3\/703","type":"journal-article","article-title":"Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI2 for mammographic x-ray imaging","volume":"58","author":"Jiang","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbaca952bib18","doi-asserted-by":"publisher","first-page":"3288","DOI":"10.1109\/TNS.2015.2497313","type":"journal-article","article-title":"Characterization of screen-printed mercuric iodide photoconductors for mammography","volume":"62","author":"Joe","year":"2015","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaca952bib19","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1109\/TNS.2004.843135","type":"journal-article","article-title":"Examination of PbI2 and HgI2 photoconductive materials for direct detection, active matrix, flat-panel imagers for diagnostic x-ray imaging","volume":"52","author":"Kang","year":"2005","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaca952bib20","first-page":"2.1\u2013.4","type":"journal-article","article-title":"Highly sensitive and reliable x-ray detector with HgI2 photoconductor and oxide drive TFR","author":"Kim","year":"2011","journal-title":"IEEE International Electron Devices Meeting (IEDM)"},{"key":"pmbaca952bib21","doi-asserted-by":"publisher","first-page":"3972","DOI":"10.1002\/mp.14321","type":"journal-article","article-title":"Empirical noise performance of prototype actve pixel arrays employing polycrystalline silicon thin-film transistors","volume":"47","author":"Koniczek","year":"2020","journal-title":"Med. Phys."},{"key":"pmbaca952bib22","doi-asserted-by":"publisher","first-page":"3151","DOI":"10.1118\/1.2937652","type":"journal-article","article-title":"SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: spatial resolution","volume":"35","author":"Li","year":"2008","journal-title":"Med. Phys."},{"key":"pmbaca952bib23","doi-asserted-by":"publisher","first-page":"1062","DOI":"10.1118\/1.2436977","type":"journal-article","article-title":"Modeling and measurement of the detector presampling MTF of a variable resolution x-ray CT scanner","volume":"34","author":"Melnyk","year":"2007","journal-title":"Med. Phys."},{"key":"pmbaca952bib24","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/7\/02\/C02009","type":"journal-article","article-title":"The development of efficient x-ray conversion material for digital mammography","volume":"7","author":"Oh","year":"2012","journal-title":"J. Instrum."},{"key":"pmbaca952bib25","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1088\/0022-3727\/28\/7\/023","type":"journal-article","article-title":"A study of trapping levels in some red mercuric iodide single crystals for nuclear radiation detection","volume":"28","author":"Pal","year":"1995","journal-title":"J. Phys. D: Appl. Phys."},{"key":"pmbaca952bib26","type":"journal-article","article-title":"High dynamic range CMOS-based mammography detector for FFDM and DBT","volume":"9783","author":"Peters","year":"2016","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib27","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.1118\/1.4907971","type":"journal-article","article-title":"Development of solid-state avalanche amorphous selenium for medical imaging","volume":"42","author":"Scheuermann","year":"2015","journal-title":"Med. Phys."},{"key":"pmbaca952bib28","doi-asserted-by":"publisher","DOI":"10.1118\/1.4770279","type":"journal-article","article-title":"A review of breast tomosynthesis: I. The image acquisition process","volume":"40","author":"Sechopoulos","year":"2013","journal-title":"Med. Phys."},{"key":"pmbaca952bib29","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac1365","type":"journal-article","article-title":"Theoretical investigation of the signal performance of HgI2 x-ray converters incorporating a Frisch grid structure at mammographic energies","volume":"66","author":"Shen","year":"2021a","journal-title":"Phys. Med. Biol."},{"key":"pmbaca952bib30","type":"journal-article","article-title":"Theoretical investigation of detector MTF of polycrystalline mercuric iodide x-ray converters incorporating Frisch grid structures for digital breast tomosynthesis","volume":"11595","author":"Shen","year":"2021b","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib31","type":"journal-article","article-title":"Effect of charge trapping and release on the performance of polycrystalline mercuric iodide x-ray converters incorporating Frisch grid structures for digital breast tomosynthesis","volume":"12031","author":"Shen","year":"2022","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib32","type":"journal-article","article-title":"Theoretical performance of polycrystalline mercuric iodide x-ray converters incorporating pillar-supported Frisch grid structure","volume":"11312","author":"Shen","year":"2020","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib33","doi-asserted-by":"publisher","first-page":"2635","DOI":"10.1118\/1.598803","type":"journal-article","article-title":"Cone-beam computed tomography with a flat-panel imager: Effects of image lag","volume":"26","author":"Siewerdsen","year":"1999","journal-title":"Med. Phys."},{"key":"pmbaca952bib34","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1109\/TNS.2005.856790","type":"journal-article","article-title":"Analysis of lead oxide (PbO) layers for direct conversion x-ray detection","volume":"52","author":"Simon","year":"2005","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaca952bib35","type":"journal-article","article-title":"SAWD: the effect of pixel geometry on the spatial uniformity of avalanche gain","volume":"10948","author":"Stavro","year":"2019","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib36","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1118\/1.1449874","type":"journal-article","article-title":"The x-ray sensitivity of amorphous selenium for mammography","volume":"29","author":"Stone","year":"2002","journal-title":"Med. Phys."},{"key":"pmbaca952bib37","doi-asserted-by":"publisher","first-page":"3345","DOI":"10.1063\/1.1436298","type":"journal-article","article-title":"Comparison of PbI2 and HgI2 for direct detection active matrix x-ray image sensors","volume":"91","author":"Street","year":"2002","journal-title":"J. Appl. Phys."},{"key":"pmbaca952bib38","doi-asserted-by":"crossref","DOI":"10.1117\/12.713848","type":"journal-article","article-title":"Dark current and DQE improvements of mercuric iodide medical imagers","volume":"6510","author":"Zentai","year":"2007","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib39","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1117\/12.535948","type":"journal-article","article-title":"Mercuric iodide medical imagers for low-exposure radiography and fluoroscopy","volume":"5368","author":"Zentai","year":"2004","journal-title":"Proc. SPIE"},{"key":"pmbaca952bib40","doi-asserted-by":"publisher","first-page":"1978","DOI":"10.1118\/1.2903425","type":"journal-article","article-title":"Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system","volume":"35","author":"Zhao","year":"2008","journal-title":"Med. Phys."},{"key":"pmbaca952bib41","doi-asserted-by":"publisher","first-page":"8977","DOI":"10.1088\/0031-9155\/60\/23\/8977","type":"journal-article","article-title":"50 \u03bcm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis","volume":"60","author":"Zhao","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"pmbaca952bib42","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1118\/1.1538233","type":"journal-article","article-title":"Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector","volume":"30","author":"Zhao","year":"2003","journal-title":"Med. Phys."},{"key":"pmbaca952bib43","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.1118\/1.1405845","type":"journal-article","article-title":"Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors","volume":"28","author":"Zhao","year":"2001","journal-title":"Med. Phys."},{"key":"pmbaca952bib44","doi-asserted-by":"publisher","first-page":"2954","DOI":"10.1118\/1.2008428","type":"journal-article","article-title":"Indirect flat-panel detector with avalanche gain: fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager)","volume":"32","author":"Zhao","year":"2005","journal-title":"Med. Phys."},{"key":"pmbaca952bib45","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1109\/TNS.2003.814544","type":"journal-article","article-title":"Near single-crystal electrical properties of polycrystalline HgI2 produced by physical vapor deposition","volume":"50","author":"Zuck","year":"2003","journal-title":"IEEE Trans. Nucl. Sci."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aca952","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aca952\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aca952\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aca952\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:01:41Z","timestamp":1778778101000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aca952"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,13]]},"references-count":45,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,1,13]]},"published-print":{"date-parts":[[2023,1,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/aca952","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,13]]},"assertion":[{"value":"Minimization of image lag in polycrystalline mercuric iodide converters through incorporation of Frisch grid structures for digital breast tomosynthesis","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2022-05-19","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-12-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-01-13","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}