{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T21:43:20Z","timestamp":1792791800756,"version":"4.5.0"},"reference-count":37,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2023,2,8]],"date-time":"2023-02-08T00:00:00Z","timestamp":1675814400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2023,2,8]],"date-time":"2023-02-08T00:00:00Z","timestamp":1675814400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"The Oklahoma Center for Advancement of Science and Technology","award":["OCAST HR19-131"],"award-info":[{"award-number":["OCAST HR19-131"]}]},{"name":"National Institute of Health","award":["R37CA240806"],"award-info":[{"award-number":["R37CA240806"]}]},{"DOI":"10.13039\/100000048","name":"American Cancer Society","doi-asserted-by":"crossref","award":["133697-RSG-19-110-01-CCE"],"award-info":[{"award-number":["133697-RSG-19-110-01-CCE"]}],"id":[{"id":"10.13039\/100000048","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2023,2,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Proton therapy as the next generation radiation-based cancer therapy offers dominant advantages over conventional radiation therapy due to the utilization of the Bragg peak; however, range uncertainty in beam delivery substantially mitigates the advantages of proton therapy. This work reports using protoacoustic measurements to determine the location of proton Bragg peak deposition within a water phantom in real time during beam delivery.\n                    <jats:italic>Approach.<\/jats:italic>\n                    In protoacoustics, proton beams have a definitive range, depositing a majority of the dose at the Bragg peak; this dose is then converted to heat. The resulting thermoelastic expansion generates a 3D acoustic wave, which can be detected by acoustic detectors to localize the Bragg peak.\n                    <jats:italic>Main results.<\/jats:italic>\n                    Protoacoustic measurements were performed with a synchrocyclotron proton machine over the exhaustive energy range from 45.5 to 227.15 MeV in clinic. It was found that the amplitude of the acoustic waves is proportional to proton dose deposition, and therefore encodes dosimetric information. With the guidance of protoacoustics, each individual proton beam (7 pC\/pulse) can be directly visualized with sub-millimeter (&lt;0.7 mm) resolution using single beam pulse for the first time.\n                    <jats:italic>Significance.<\/jats:italic>\n                    The ability to localize the Bragg peak in real-time and obtain acoustic signals proportional to dose within tumors could enable precision proton therapy and hope to progress towards\n                    <jats:italic>in vivo<\/jats:italic>\n                    measurements.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/acb2ae","type":"journal-article","created":{"date-parts":[[2023,1,12]],"date-time":"2023-01-12T17:41:29Z","timestamp":1673545289000},"page":"045011","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":16,"title":["Single pulse protoacoustic range verification using a clinical synchrocyclotron"],"prefix":"10.1088","volume":"68","author":[{"given":"Joseph","family":"Caron","sequence":"first","affiliation":[{"name":"University of Oklahoma Health Sciences Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gilberto","family":"Gonzalez","sequence":"additional","affiliation":[{"name":"University of Oklahoma Health Sciences Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prabodh Kumar","family":"Pandey","sequence":"additional","affiliation":[{"name":"University of California at Irvine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siqi","family":"Wang","sequence":"additional","affiliation":[{"name":"University of California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6753-2787","authenticated-orcid":false,"given":"Kiana","family":"Prather","sequence":"additional","affiliation":[{"name":"University of Oklahoma"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salahuddin","family":"Ahmad","sequence":"additional","affiliation":[{"name":"University of Oklahoma Health Sciences Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liangzhong","family":"Xiang","sequence":"additional","affiliation":[{"name":"University of California at Irvine"},{"name":"University of California"},{"name":"University of California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Chen","sequence":"additional","affiliation":[{"name":"University of Oklahoma Health Sciences Center"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2023,2,8]]},"reference":[{"key":"pmbacb2aebib1","doi-asserted-by":"publisher","first-page":"5735","DOI":"10.1118\/1.4929939","type":"journal-article","article-title":"Theoretical detection threshold of the proton-acoustic range verification technique","volume":"42","author":"Ahmad","year":"2015","journal-title":"Med. Phys."},{"key":"pmbacb2aebib2","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1118\/1.4905047","type":"journal-article","article-title":"Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy","volume":"42","author":"Assmann","year":"2015","journal-title":"Med. Phys."},{"key":"pmbacb2aebib3","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.ijrobp.2013.01.014","type":"journal-article","article-title":"Proton beam craniospinal irradiation reduces acute toxicity for adults with medulloblastoma","volume":"86","author":"Brown","year":"2013","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbacb2aebib4","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab7506","type":"journal-article","article-title":"Proton range verification with ultrasound imaging using injectable radiation sensitive nanodroplets: a feasibility study","volume":"65","author":"Carlier","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbacb2aebib5","doi-asserted-by":"publisher","first-page":"3","DOI":"10.2967\/jnumed.116.184028","type":"journal-article","article-title":"Total-body PET: maximizing sensitivity to create new opportunities for clinical research and patient care","volume":"59","author":"Cherry","year":"2018","journal-title":"J. Nucl. Med."},{"key":"pmbacb2aebib6","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1186\/s13014-019-1378-x","type":"journal-article","article-title":"Conventional versus hypofractionated postmastectomy radiotherapy: a report on long-term outcomes and late toxicity","volume":"14","author":"Chitapanarux","year":"2019","journal-title":"Radiat Oncol."},{"key":"pmbacb2aebib7","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.ultrasmedbio.2021.09.009","type":"journal-article","article-title":"Spatiotemporal distribution of nanodroplet vaporization in a proton beam using real-time ultrasound imaging for range verification","volume":"48","author":"Collado-Lara","year":"2022","journal-title":"Ultrasound Med. Biol."},{"key":"pmbacb2aebib8","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1007\/s00066-021-01782-5","type":"journal-article","article-title":"Conventional 3D conformal radiotherapy and volumetric modulated arc therapy for cervical cancer: comparison of clinical results with special consideration of the influence of patient- and treatment-related parameters","volume":"197","author":"Droge","year":"2021","journal-title":"Strahlenther Onkol."},{"key":"pmbacb2aebib9","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1097\/01.coc.0000197661.09628.03","type":"journal-article","article-title":"Intensity modulated radiation therapy (IMRT) decreases acute skin toxicity for women receiving radiation for breast cancer","volume":"29","author":"Freedman","year":"2006","journal-title":"Am. J. Clin. Oncol."},{"key":"pmbacb2aebib10","first-page":"p. 597","type":"book","volume":"vii","author":"Hall","year":"2019","edition":"Eighth edition"},{"key":"pmbacb2aebib11","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1007\/s00066-016-1005-9","type":"journal-article","article-title":"Dosimetric advantages of proton therapy over conventional radiotherapy with photons in young patients and adults with low-grade glioma","volume":"192","author":"Harrabi","year":"2016","journal-title":"Strahlenther Onkol."},{"key":"pmbacb2aebib12","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1002\/roi.2970030107","type":"journal-article","article-title":"Acoustic pulse generated in a patient during treatment by pulsed proton radiation beam.","volume":"3","author":"Hayakawa","year":"1995","journal-title":"Radiat. Oncol. Investigations"},{"key":"pmbacb2aebib13","doi-asserted-by":"publisher","first-page":"e707","DOI":"10.1002\/mp.12929","type":"journal-article","article-title":"Ionizing radiation-induced acoustics for radiotherapy and diagnostic radiology applications","volume":"45","author":"Hickling","year":"2018","journal-title":"Med. Phys."},{"key":"pmbacb2aebib14","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac9881","type":"journal-article","article-title":"3D in vivo dose verification in prostate proton therapy with deep learning-based proton-acoustic imaging","volume":"67","author":"Jiang","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbacb2aebib15","doi-asserted-by":"publisher","first-page":"7090","DOI":"10.1118\/1.4935865","type":"journal-article","article-title":"Experimental observation of acoustic emissions generated by a pulsed proton beam from a hospital-based clinical cyclotron","volume":"42","author":"Jones","year":"2015","journal-title":"Med. Phys."},{"key":"pmbacb2aebib16","doi-asserted-by":"publisher","first-page":"5213","DOI":"10.1118\/1.4961120","type":"journal-article","article-title":"Acoustic time-of-flight for proton range verification in water","volume":"43","author":"Jones","year":"2016","journal-title":"Med. Phys."},{"key":"pmbacb2aebib17","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa9d16","type":"journal-article","article-title":"Acoustic-based proton range verification in heterogeneous tissue: simulation studies","volume":"63","author":"Jones","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbacb2aebib18","doi-asserted-by":"publisher","DOI":"10.1038\/srep29305","type":"journal-article","article-title":"Ionoacoustic tomography of the proton Bragg peak in combination with ultrasound and optoacoustic imaging","volume":"6","author":"Kellnberger","year":"2016","journal-title":"Sci. Rep."},{"key":"pmbacb2aebib19","doi-asserted-by":"publisher","first-page":"4853","DOI":"10.1088\/0031-9155\/50\/20\/008","type":"journal-article","article-title":"Intrafractional motion during proton beam scanning","volume":"50","author":"Lambert","year":"2005","journal-title":"Phys. Med. Biol."},{"key":"pmbacb2aebib20","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-81964-4","type":"journal-article","article-title":"Enhancement of the ionoacoustic effect through ultrasound and photoacoustic contrast agents","volume":"11","author":"Lascaud","year":"2021","journal-title":"Sci. Rep."},{"key":"pmbacb2aebib21","doi-asserted-by":"publisher","first-page":"L20","DOI":"10.1088\/1361-6560\/aa81f8","type":"journal-article","article-title":"Submillimeter ionoacoustic range determination for protons in water at a clinical synchrocyclotron","volume":"62","author":"Lehrack","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"pmbacb2aebib22","doi-asserted-by":"publisher","first-page":"4800","DOI":"10.1118\/1.2982242","type":"journal-article","article-title":"Dosimetric uncertainty in prostate cancer proton radiotherapy","volume":"35","author":"Lin","year":"2008","journal-title":"Med. Phys."},{"key":"pmbacb2aebib23","doi-asserted-by":"publisher","first-page":"5090","DOI":"10.1002\/mp.14358","type":"journal-article","article-title":"An ionizing radiation acoustic imaging (iRAI) technique for real-time dosimetric measurements for FLASH radiotherapy","volume":"47","author":"Oraiqat","year":"2020","journal-title":"Med. Phys."},{"key":"pmbacb2aebib24","doi-asserted-by":"publisher","first-page":"R99","DOI":"10.1088\/0031-9155\/57\/11\/R99","type":"journal-article","article-title":"Range uncertainties in proton therapy and the role of Monte Carlo simulations","volume":"57","author":"Paganetti","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbacb2aebib25","author":"Paganetti","year":"2019","edition":"2nd edn","type":"book"},{"key":"pmbacb2aebib26","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1118\/1.2401042","type":"journal-article","article-title":"PET\/CT imaging for treatment verification after proton therapy: a study with plastic phantoms and metallic implants","volume":"34","author":"Parodi","year":"2007","journal-title":"Med. Phys."},{"key":"pmbacb2aebib27","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.radonc.2021.03.027","type":"journal-article","article-title":"Thermoacoustic range verification during pencil beam delivery of a clinical plan to an abdominal imaging phantom","volume":"159","author":"Patch","year":"2021","journal-title":"Radiother. Oncol."},{"key":"pmbacb2aebib28","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1109\/TRPMS.2022.3177236","type":"journal-article","article-title":"3D protoacoustic imaging through a planar ultrasound array: a simulation workflow","volume":"7","author":"Pratik Samant","year":"2022","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbacb2aebib29","doi-asserted-by":"publisher","first-page":"1579","DOI":"10.1088\/0031-9155\/43\/6\/016","type":"journal-article","article-title":"The precision of proton range calculations in proton radiotherapy treatment planning: experimental verification of the relation between CT-HU and proton stopping power","volume":"43","author":"Schaffner","year":"1998","journal-title":"Phys. Med. Biol."},{"key":"pmbacb2aebib30","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1002\/acm2.12714","type":"journal-article","article-title":"Impact of intrafraction prostate motion on clinical target coverage in proton therapy: a simulation study of dosimetric differences in two delivery techniques","volume":"20","author":"Su","year":"2019","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbacb2aebib31","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/0029-554X(79)90386-0","type":"journal-article","article-title":"Experimental studies of the acoustic signature of proton beams traversing fluid media","volume":"161","author":"Sulak","year":"1979","journal-title":"Nucl. Instrum. Methods"},{"key":"pmbacb2aebib32","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.phro.2018.04.002","type":"journal-article","article-title":"Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer","volume":"6","author":"Taasti","year":"2018","journal-title":"Phys. Imaging Radiat. Oncol."},{"key":"pmbacb2aebib33","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abc939","type":"journal-article","article-title":"Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning","volume":"66","author":"Tian","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"pmbacb2aebib34","doi-asserted-by":"publisher","first-page":"212","DOI":"10.21037\/jgo.2019.11.07","type":"journal-article","article-title":"Managing treatment-related uncertainties in proton beam radiotherapy for gastrointestinal cancers","volume":"11","author":"Tryggestad","year":"2020","journal-title":"J. Gastrointest. Oncol."},{"key":"pmbacb2aebib35","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/1561\/1\/012021","type":"journal-article","article-title":"Prompt gamma imaging in proton therapy - status, challenges and developments","volume":"1561","author":"Wroska","year":"2020","journal-title":"J. Phys. Conf. Ser."},{"key":"pmbacb2aebib36","doi-asserted-by":"publisher","first-page":"10","DOI":"10.34133\/2020\/9853609","type":"journal-article","article-title":"Dual-modality x-ray-induced radiation acoustic and ultrasound imaging for real-time monitoring of radiotherapy","volume":"2020","author":"Zhang","year":"2020","journal-title":"BME Frontiers"},{"key":"pmbacb2aebib37","doi-asserted-by":"publisher","first-page":"731","DOI":"10.7150\/thno.5162","type":"journal-article","article-title":"Proton therapy verification with PET imaging","volume":"3","author":"Zhu","year":"2013","journal-title":"Theranostics."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:14:28Z","timestamp":1778778868000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acb2ae"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,8]]},"references-count":37,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,2,8]]},"published-print":{"date-parts":[[2023,2,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/acb2ae","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,8]]},"assertion":[{"value":"Single pulse protoacoustic range verification using a clinical synchrocyclotron","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2022-08-12","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-01-12","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-02-08","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}