{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T19:28:49Z","timestamp":1790364529022,"version":"4.1.0"},"reference-count":29,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2023,2,23]],"date-time":"2023-02-23T00:00:00Z","timestamp":1677110400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,2,23]],"date-time":"2023-02-23T00:00:00Z","timestamp":1677110400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2023,3,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . The purpose of this study was to evaluate the accuracy of brachytherapy (BT) planning structures derived from Deep learning (DL) based auto-segmentation compared with standard manual delineation for postoperative cervical cancer.\n                    <jats:italic>Approach<\/jats:italic>\n                    . We introduced a convolutional neural networks (CNN) which was developed and presented for auto-segmentation in cervical cancer radiotherapy. The dataset of 60 patients received BT of postoperative cervical cancer was used to train and test this model for delineation of high-risk clinical target volume (HRCTV) and organs at risk (OARs). Dice similarity coefficient (DSC), 95% Hausdorff distance (95%HD), Jaccard coefficient (JC) and dose-volume index (DVI) were used to evaluate the accuracy. The correlation between geometric metrics and dosimetric difference was performed by Spearman\u2019s correlation analysis. The radiation oncologists scored the auto-segmented contours by rating the lever of satisfaction (no edits, minor edits, major edits).\n                    <jats:italic>Main results<\/jats:italic>\n                    . The mean DSC values of DL based model were 0.87, 0.94, 0.86, 0.79 and 0.92 for HRCTV, bladder, rectum, sigmoid and small intestine, respectively. The Bland-Altman test obtained dose agreement for HRCTV_D\n                    <jats:sub>90%<\/jats:sub>\n                    , HRCTV_D\n                    <jats:sub>mean<\/jats:sub>\n                    , bladder_D\n                    <jats:sub>2cc<\/jats:sub>\n                    , sigmoid_D\n                    <jats:sub>2cc<\/jats:sub>\n                    and small intestine_D\n                    <jats:sub>2cc<\/jats:sub>\n                    . Wilcoxon\u2019s signed-rank test indicated significant dosimetric differences in bladder_D\n                    <jats:sub>0.1cc<\/jats:sub>\n                    , rectum_D\n                    <jats:sub>0.1cc<\/jats:sub>\n                    and rectum_D\n                    <jats:sub>2cc<\/jats:sub>\n                    (\n                    <jats:italic>P<\/jats:italic>\n                    &lt; 0.05). A strong correlation between HRCTV_D\n                    <jats:sub>90%<\/jats:sub>\n                    with its DSC (\n                    <jats:italic>R<\/jats:italic>\n                    = \u22120.842,\n                    <jats:italic>P<\/jats:italic>\n                    = 0.002) and JC (\n                    <jats:italic>R<\/jats:italic>\n                    = \u22120.818,\n                    <jats:italic>P<\/jats:italic>\n                    = 0.004) were found in Spearman\u2019s correlation analysis. From the physician review, 80% of HRCTVs and 72.5% of OARs in the test dataset were shown satisfaction (no edits).\n                    <jats:italic>Significance<\/jats:italic>\n                    . The proposed DL based model achieved a satisfied agreement between the auto-segmented and manually defined contours of HRCTV and OARs, although the clinical acceptance of small volume dose of OARs around the target was a concern. DL based auto-segmentation was an essential component in cervical cancer workflow which would generate the accurate contouring.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/acba76","type":"journal-article","created":{"date-parts":[[2023,2,8]],"date-time":"2023-02-08T17:46:16Z","timestamp":1675878376000},"page":"055012","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":16,"title":["Evaluation of auto-segmentation for brachytherapy of postoperative cervical cancer using deep learning-based workflow"],"prefix":"10.1088","volume":"68","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9998-7658","authenticated-orcid":true,"given":"Jiahao","family":"Wang","sequence":"first","affiliation":[{"name":"Zhejiang University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanyuan","family":"Chen","sequence":"additional","affiliation":[{"name":"Zhejiang University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yeqiang","family":"Tu","sequence":"additional","affiliation":[{"name":"Zhejiang University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongling","family":"Xie","sequence":"additional","affiliation":[{"name":"Zhejiang University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukai","family":"Chen","sequence":"additional","affiliation":[{"name":"Zhejiang University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lumeng","family":"Luo","sequence":"additional","affiliation":[{"name":"Zhejiang University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pengfei","family":"Zhou","sequence":"additional","affiliation":[{"name":"Zhejiang University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiu","family":"Tang","sequence":"additional","affiliation":[{"name":"Zhejiang University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2023,2,23]]},"reference":[{"key":"pmbacba76bib1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/jicru\/ndw027","type":"journal-article","article-title":"Prescribing, recording, and reporting brachytherapy for cancer of the cervix","volume":"13(1-2)","year":"2013","journal-title":"J ICRU"},{"key":"pmbacba76bib2","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20200842","type":"journal-article","article-title":"Artificial intelligence in brachytherapy: a summary of recent developments","volume":"94","author":"Banerjee","year":"2021","journal-title":"Br. J. Radiol."},{"key":"pmbacba76bib3","doi-asserted-by":"publisher","first-page":"1712","DOI":"10.1002\/mp.15490","type":"journal-article","article-title":"Automatic segmentation of high-risk clinical target volume for tandem-and-ovoids brachytherapy patients using an asymmetric dual-path convolutional neural network","volume":"49","author":"Cao","year":"2022","journal-title":"Med. Phys."},{"key":"pmbacba76bib4","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.ijrobp.2018.01.114","type":"journal-article","article-title":"Deep learning algorithm for auto-delineation of high-risk oropharyngeal clinical target volumes with built-in dice similarity coefficient parameter optimization function","volume":"101","author":"Cardenas","year":"2018","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbacba76bib5","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/j.prro.2020.04.002","type":"journal-article","article-title":"Radiation therapy for cervical cancer: executive summary of an ASTRO clinical practice guideline","volume":"10","author":"Chino","year":"2020","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbacba76bib6","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1136\/ijgc-2020-001412","type":"journal-article","article-title":"Long-term outcomes of intensity-modulated radiation therapy (IMRT) and high dose rate brachytherapy as adjuvant therapy after radical hysterectomy for cervical cancer","volume":"30","author":"Contreras","year":"2020","journal-title":"Int. J. Gynecol. Cancer"},{"key":"pmbacba76bib7","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.radonc.2011.12.024","type":"journal-article","article-title":"Recommendations from gynaecological (GYN) GEC-ESTRO working group (IV): basic principles and parameters for MR imaging within the frame of image based adaptive cervix cancer brachytherapy","volume":"103","author":"Dimopoulos","year":"2012","journal-title":"Radiother. Oncol."},{"key":"pmbacba76bib8","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/j.brachy.2013.08.010","type":"journal-article","article-title":"Impact of delineation uncertainties on dose to organs at risk in CT-guided intracavitary brachytherapy","volume":"13","author":"Duane","year":"2014","journal-title":"Brachytherapy"},{"key":"pmbacba76bib9","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1016\/j.ijrobp.2010.12.029","type":"journal-article","article-title":"Dose effect relationship for late side effects of the rectum and urinary bladder in magnetic resonance image-guided adaptive cervix cancer brachytherapy","volume":"82","author":"Georg","year":"2012","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbacba76bib10","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.radonc.2004.12.015","type":"journal-article","article-title":"Recommendations from gynaecological (GYN) GEC-ESTRO working group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV","volume":"74","author":"Haie-Meder","year":"2005","journal-title":"Radiother. Oncol."},{"key":"pmbacba76bib11","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1016\/j.ijrobp.2015.03.010","type":"journal-article","article-title":"Image-based brachytherapy for the treatment of cervical cancer","volume":"92","author":"Harkenrider","year":"2015","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbacba76bib12","doi-asserted-by":"publisher","first-page":"771","DOI":"10.1038\/s41571-020-0417-8","type":"journal-article","article-title":"Artificial intelligence in radiation oncology","volume":"17","author":"Huynh","year":"2020","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"pmbacba76bib13","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.radonc.2013.01.011","type":"journal-article","article-title":"Inter-application variation of dose and spatial location of D2cm3 volumes of OARs during MR image based cervix brachytherapy","volume":"107","author":"Jamema","year":"2013","journal-title":"Radiother. Oncol."},{"key":"pmbacba76bib14","doi-asserted-by":"publisher","first-page":"1721","DOI":"10.21037\/atm-21-4074","type":"journal-article","article-title":"RefineNet-based automatic delineation of the clinical target volume and organs at risk for three-dimensional brachytherapy for cervical cancer","volume":"9","author":"Jiang","year":"2021","journal-title":"Ann. Transl. Med."},{"key":"pmbacba76bib15","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1038\/nature14539","type":"journal-article","article-title":"Deep learning","volume":"521","author":"LeCun","year":"2015","journal-title":"Nature"},{"key":"pmbacba76bib16","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1186\/s13014-021-01877-4","type":"journal-article","article-title":"Stereotactic ablative body radiotherapy boost for cervical cancer when brachytherapy boost is not feasible","volume":"16","author":"Lee","year":"2021","journal-title":"Radiat. Oncol."},{"key":"pmbacba76bib17","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/j.radonc.2020.09.060","type":"journal-article","article-title":"Development and validation of a deep learning algorithm for auto-delineation of clinical target volume and organs at risk in cervical cancer radiotherapy","volume":"153","author":"Liu","year":"2020a","journal-title":"Radiother. Oncol."},{"key":"pmbacba76bib18","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1016\/j.ejmp.2019.12.008","type":"journal-article","article-title":"Segmentation of organs-at-risk in cervical cancer CT images with a convolutional neural network","volume":"69","author":"Liu","year":"2020b","journal-title":"Med. Phys."},{"key":"pmbacba76bib19","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1016\/j.brachy.2019.08.006","type":"journal-article","article-title":"Vaginal cuff brachytherapy in the adjuvant setting for patients with high-risk early-stage cervical cancer","volume":"18","author":"Mauro","year":"2019","journal-title":"Brachytherapy"},{"key":"pmbacba76bib20","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.radonc.2021.03.030","type":"journal-article","article-title":"Deep learning-based auto-segmentation of organs at risk in high-dose rate brachytherapy of cervical cancer","volume":"159","author":"Mohammadi","year":"2021","journal-title":"Radiother. Oncol."},{"key":"pmbacba76bib21","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1200\/JCO.2014.59.8128","type":"journal-article","article-title":"Brachytherapy: where has it gone ?","volume":"33","author":"Petereit","year":"2015","journal-title":"J. Clin. Oncol."},{"key":"pmbacba76bib22","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ctro.2018.01.001","type":"journal-article","article-title":"The EMBRACE II study: The outcome and prospect of two decades of evolution within the GEC-ESTRO GYN working group and the EMBRACE studies","volume":"9","author":"Potter","year":"2018","journal-title":"Clin. Transl. Radiat. Oncol."},{"key":"pmbacba76bib23","doi-asserted-by":"publisher","first-page":"5648","DOI":"10.1002\/mp.14467","type":"journal-article","article-title":"Automatic contouring system for cervical cancer using convolutional neural networks","volume":"47","author":"Rhee","year":"2020","journal-title":"Phys. Med."},{"key":"pmbacba76bib24","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/S0167-8140(00)00185-7","type":"journal-article","article-title":"Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancer","volume":"56","author":"Saarnak","year":"2000","journal-title":"Radiother. Oncol."},{"key":"pmbacba76bib25","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1136\/ijgc-2021-002466","type":"journal-article","article-title":"Role of stereotactic body radiotherapy in gynecologic radiation oncology","volume":"32","author":"Shenker","year":"2022","journal-title":"Int. J. Gynecol. Cancer"},{"key":"pmbacba76bib26","doi-asserted-by":"publisher","first-page":"13650","DOI":"10.1038\/s41598-022-18084-0","type":"journal-article","article-title":"Evaluation of auto-segmentation for EBRT planning structures using deep learning-based workflow on cervical cancer","volume":"12","author":"Wang","year":"2022","journal-title":"Sci. Rep."},{"key":"pmbacba76bib27","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1002\/acm2.13097","type":"journal-article","article-title":"Evaluation of deep learning-based auto-segmentation algorithms for delineating clinical target volume and organs at risk involving data for 125 cervical cancer patients","volume":"21","author":"Wang","year":"2020","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbacba76bib28","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1002\/mp.15506","type":"journal-article","article-title":"Automatic segmentation of magnetic resonance images for high-dose-rate cervical cancer brachytherapy using deep learning","volume":"49","author":"Yoganathan","year":"2022","journal-title":"Med. Phys."},{"key":"pmbacba76bib29","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1002\/acm2.13024","type":"journal-article","article-title":"Automatic segmentation and applicator reconstruction for CT-based brachytherapy of cervical cancer using 3D convolutional neural networks","volume":"21","author":"Zhang","year":"2020","journal-title":"J. Appl. Clin. Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:54:22Z","timestamp":1778777662000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acba76"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,23]]},"references-count":29,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023,2,23]]},"published-print":{"date-parts":[[2023,3,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/acba76","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,23]]},"assertion":[{"value":"Evaluation of auto-segmentation for brachytherapy of postoperative cervical cancer using deep learning-based workflow","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2022-11-13","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-02-08","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-02-23","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}