{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:07:14Z","timestamp":1787008034421,"version":"build-2736575974"},"reference-count":52,"publisher":"IOP Publishing","issue":"10","license":[{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Research Training Group GRK 2274"},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"crossref","award":["399148265"],"award-info":[{"award-number":["399148265"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2023,5,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Daily cone beam computed tomography (CBCT) imaging during the course of fractionated radiotherapy treatment can enable online adaptive radiotherapy but also expose patients to a non-negligible amount of radiation dose. This work investigates the feasibility of low dose CBCT imaging capable of enabling accurate prostate radiotherapy dose calculation with only 25% projections by overcoming under-sampling artifacts and correcting CT numbers by employing cycle-consistent generative adversarial networks (cycleGAN). Uncorrected CBCTs of 41 prostate cancer patients, acquired with \u223c350 projections (CBCT\n                    <jats:sub>org<\/jats:sub>\n                    ), were retrospectively under-sampled to 25% dose images (CBCT\n                    <jats:sub>LD<\/jats:sub>\n                    ) with only \u223c90 projections and reconstructed using Feldkamp\u2013Davis\u2013Kress. We adapted a cycleGAN including shape loss to translate CBCT\n                    <jats:sub>LD<\/jats:sub>\n                    into planning CT (pCT) equivalent images (CBCT\n                    <jats:sub>LD_GAN<\/jats:sub>\n                    ). An alternative cycleGAN with a generator residual connection was implemented to improve anatomical fidelity (CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    ). Unpaired 4-fold cross-validation (33 patients) was performed to allow using the median of 4 models as output. Deformable image registration was used to generate virtual CTs (vCT) for Hounsfield units (HU) accuracy evaluation on 8 additional test patients. Volumetric modulated arc therapy plans were optimized on vCT, and recalculated on CBCT\n                    <jats:sub>LD_GAN<\/jats:sub>\n                    and CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    to determine dose calculation accuracy. CBCT\n                    <jats:sub>LD_GAN<\/jats:sub>\n                    , CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    and CBCT\n                    <jats:sub>org<\/jats:sub>\n                    were registered to pCT and residual shifts were analyzed. Bladder and rectum were manually contoured on CBCT\n                    <jats:sub>LD_GAN<\/jats:sub>\n                    , CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    and CBCT\n                    <jats:sub>org<\/jats:sub>\n                    and compared in terms of Dice similarity coefficient (DSC), average and 95th percentile Hausdorff distance (HD\n                    <jats:sub>avg<\/jats:sub>\n                    , HD\n                    <jats:sub>95<\/jats:sub>\n                    ). The mean absolute error decreased from 126 HU for CBCT\n                    <jats:sub>LD<\/jats:sub>\n                    to 55 HU for CBCT\n                    <jats:sub>LD_GAN<\/jats:sub>\n                    and 44 HU for CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    . For PTV, the median differences of\n                    <jats:italic>D<\/jats:italic>\n                    <jats:sub>98%<\/jats:sub>\n                    ,\n                    <jats:italic>D<\/jats:italic>\n                    <jats:sub>50%<\/jats:sub>\n                    and\n                    <jats:italic>D<\/jats:italic>\n                    <jats:sub>2%<\/jats:sub>\n                    comparing both CBCT\n                    <jats:sub>LD_GAN<\/jats:sub>\n                    to vCT were 0.3%, 0.3%, 0.3%, and comparing CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    to vCT were 0.4%, 0.3% and 0.4%. Dose accuracy was high with both 2% dose difference pass rates of 99% (10% dose threshold). Compared to the CBCT\n                    <jats:sub>org<\/jats:sub>\n                    -to-pCT registration, the majority of mean absolute differences of rigid transformation parameters were less than 0.20 mm\/0.20\u00b0. For bladder and rectum, the DSC were 0.88 and 0.77 for CBCT\n                    <jats:sub>LD_GAN<\/jats:sub>\n                    and 0.92 and 0.87 for CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    compared to CBCT\n                    <jats:sub>org<\/jats:sub>\n                    , and HD\n                    <jats:sub>avg<\/jats:sub>\n                    were 1.34 mm and 1.93 mm for CBCT\n                    <jats:sub>LD_GAN<\/jats:sub>\n                    , and 0.90 mm and 1.05 mm for CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    . The computational time was \u223c2 s per patient. This study investigated the feasibility of adapting two cycleGAN models to simultaneously remove under-sampling artifacts and correct image intensities of 25% dose CBCT images. High accuracy on dose calculation, HU and patient alignment were achieved. CBCT\n                    <jats:sub>LD_ResGAN<\/jats:sub>\n                    achieved better anatomical fidelity.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/acccce","type":"journal-article","created":{"date-parts":[[2023,4,13]],"date-time":"2023-04-13T19:07:46Z","timestamp":1681412866000},"page":"105014","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":19,"title":["Feasibility of CycleGAN enhanced low dose CBCT imaging for prostate radiotherapy dose calculation"],"prefix":"10.1088","volume":"68","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2364-535X","authenticated-orcid":false,"given":"Y","family":"Chan","sequence":"first","affiliation":[{"name":"University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M","family":"Li","sequence":"additional","affiliation":[{"name":"University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K","family":"Parodi","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen (LMU Munich), D-85748 Garching,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C","family":"Belka","sequence":"additional","affiliation":[{"name":"University Hospital"},{"name":"German Cancer Consortium (DKTK)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1707-4068","authenticated-orcid":false,"given":"G","family":"Landry","sequence":"additional","affiliation":[{"name":"University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C","family":"Kurz","sequence":"additional","affiliation":[{"name":"University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2023,5,11]]},"reference":[{"key":"pmbaccccebib1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13479","type":"journal-article","article-title":"Varian ethos online adaptive radiotherapy for prostate cancer: early results of contouring accuracy, treatment plan quality, and treatment time","volume":"23","author":"Byrne","year":"2022","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaccccebib2","doi-asserted-by":"publisher","first-page":"5113","DOI":"10.1118\/1.3481510","type":"journal-article","article-title":"Compressed sensing based cone-beam computed tomography reconstruction with a first-order method a","volume":"37","author":"Choi","year":"2010","journal-title":"Med. Phys."},{"key":"pmbaccccebib3","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2021.102004","type":"journal-article","article-title":"Residual cyclegan for robust domain transformation of histopathological tissue slides","volume":"70","author":"de Bel","year":"2021","journal-title":"Med. Image Anal."},{"key":"pmbaccccebib4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13014-021-01866-7","type":"journal-article","article-title":"Feasibility of conebeam ct-based online adaptive radiotherapy for neoadjuvant treatment of rectal cancer","volume":"16","author":"de Jong","year":"2021","journal-title":"Radiat. Oncol."},{"key":"pmbaccccebib5","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac7b0a","type":"journal-article","article-title":"Improving cone-beam ct quality using a cycle-residual connection with a dilated convolution-consistent generative adversarial network","volume":"67","author":"Deng","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib6","doi-asserted-by":"publisher","first-page":"e84\u2013e99","DOI":"10.1002\/mp.12824","type":"journal-article","article-title":"Image guidance doses delivered during radiotherapy: quantification, management, and reduction: report of the aapm therapy physics committee task group 180","volume":"45","author":"Ding","year":"2018","journal-title":"Med. Phys."},{"key":"pmbaccccebib7","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.radonc.2007.06.015","type":"journal-article","article-title":"A study on adaptive imrt treatment planning using kv cone-beam CT","volume":"85","author":"Ding","year":"2007","journal-title":"Radiother. Oncol."},{"key":"pmbaccccebib8","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/j.radonc.2012.06.007","type":"journal-article","article-title":"Feasibility of CBCT-based dose calculation: comparative analysis of hu adjustment techniques","volume":"104","author":"Fotina","year":"2012","journal-title":"Radiother. Oncol."},{"key":"pmbaccccebib9","doi-asserted-by":"publisher","first-page":"1096","DOI":"10.1109\/ISBI.2019.8759529","type":"conference-proceedings","article-title":"Unpaired MR to CT synthesis with explicit structural constrained adversarial learning","author":"Ge","year":"2019"},{"key":"pmbaccccebib10","doi-asserted-by":"publisher","DOI":"10.48550\/arXiv.1406.2661","type":"conference-proceedings","article-title":"Generative adversarial nets","volume":"vol 27","author":"Goodfellow","year":"2014"},{"key":"pmbaccccebib11","doi-asserted-by":"publisher","first-page":"4916","DOI":"10.1002\/mp.13175","type":"journal-article","article-title":"Scatternet: a convolutional neural network for cone-beam ct intensity correction","volume":"45","author":"Hansen","year":"2018","journal-title":"Med. Phys."},{"key":"pmbaccccebib12","doi-asserted-by":"publisher","first-page":"3998","DOI":"10.1002\/mp.13656","type":"journal-article","article-title":"Paired cycle-gan-based image correction for quantitative cone-beam computed tomography","volume":"46","author":"Harms","year":"2019","journal-title":"Med. Phys."},{"key":"pmbaccccebib13","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1016\/j.radonc.2017.09.020","type":"journal-article","article-title":"Multi-criterial patient positioning based on dose recalculation on scatter-corrected cbct images","volume":"125","author":"Hofmaier","year":"2017","journal-title":"Radiother. Oncol."},{"key":"pmbaccccebib14","doi-asserted-by":"publisher","first-page":"4620","DOI":"10.1118\/1.3476459","type":"journal-article","article-title":"Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification","volume":"37","author":"Hyer","year":"2010","journal-title":"Med. Phys."},{"key":"pmbaccccebib15","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.48550\/arXiv.1611.07004","type":"conference-proceedings","article-title":"Image-to-image translation with conditional adversarial networks","author":"Isola","year":"2017"},{"key":"pmbaccccebib16","doi-asserted-by":"publisher","first-page":"694","DOI":"10.48550\/arXiv.1603.08155","type":"conference-proceedings","article-title":"Perceptual losses for real-time style transfer and super-resolution","author":"Johnson","year":"2016"},{"key":"pmbaccccebib17","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.ijrobp.2007.08.062","type":"journal-article","article-title":"Radiation dose from cone beam computed tomography for image-guided radiation therapy","volume":"70","author":"Kan","year":"2008","journal-title":"Int. J. Radiat. Oncol.* Biol.* Phys."},{"key":"pmbaccccebib18","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1002\/mp.13963","type":"journal-article","article-title":"Visual enhancement of Cone-beam CT by use of CycleGAN","volume":"47","author":"Kida","year":"2019","journal-title":"Med. Phys."},{"key":"pmbaccccebib19","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.2548","type":"journal-article","article-title":"Cone beam computed tomography image quality improvement using a deep convolutional neural network","volume":"10","author":"Kida","year":"2018","journal-title":"Cureus"},{"key":"pmbaccccebib20","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1097\/HP.0b013e318285c685","type":"journal-article","article-title":"Imaging doses and secondary cancer risk from kilovoltage cone-beam ct in radiation therapy","volume":"104","author":"Kim","year":"2013","journal-title":"Health Phys."},{"key":"pmbaccccebib21","doi-asserted-by":"publisher","first-page":"1651","DOI":"10.3109\/0284186X.2015.1061206","type":"journal-article","article-title":"Comparing cone-beam ct intensity correction methods for dose recalculation in adaptive intensity-modulated photon and proton therapy for head and neck cancer","volume":"54","author":"Kurz","year":"2015","journal-title":"Acta Oncol."},{"key":"pmbaccccebib22","doi-asserted-by":"publisher","first-page":"5635","DOI":"10.1118\/1.4962933","type":"journal-article","article-title":"Investigating deformable image registration and scatter correction for cbct-based dose calculation in adaptive impt","volume":"43","author":"Kurz","year":"2016","journal-title":"Med. Phys."},{"key":"pmbaccccebib23","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab4d8c","type":"journal-article","article-title":"Cbct correction using a cycle-consistent generative adversarial network and unpaired training to enable photon and proton dose calculation","volume":"64","author":"Kurz","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib24","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1088\/0031-9155\/60\/2\/595","type":"journal-article","article-title":"Phantom based evaluation of CT to CBCT image registration for proton therapy dose recalculation","volume":"60","author":"Landry","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib25","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaf496","type":"journal-article","article-title":"Comparing unet training with three different datasets to correct cbct images for prostate radiotherapy dose calculations","volume":"64","author":"Landry","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib26","doi-asserted-by":"publisher","first-page":"1354","DOI":"10.1118\/1.4908223","type":"journal-article","article-title":"Investigating ct to cbct image registration for head and neck proton therapy as a tool for daily dose recalculation","volume":"42","author":"Landry","year":"2015","journal-title":"Med. Phys."},{"key":"pmbaccccebib27","doi-asserted-by":"publisher","first-page":"2287","DOI":"10.1088\/0031-9155\/57\/8\/2287","type":"journal-article","article-title":"Improved compressed sensing-based cone-beam ct reconstruction using adaptive prior image constraints","volume":"57","author":"Lee","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib28","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab22f9","type":"journal-article","article-title":"Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using cyclegan for adaptive radiation therapy","volume":"64","author":"Liang","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib29","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac6289","type":"journal-article","article-title":"A two-step method to improve image quality of cbct with phantom-based supervised and patient-based unsupervised learning strategies","volume":"67","author":"Liu","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib30","doi-asserted-by":"publisher","DOI":"10.1117\/12.2292919","type":"conference-proceedings","article-title":"Deep scatter estimation (DSE): feasibility of using a deep convolutional neural network for real-time x-ray scatter prediction in cone-beam CT","author":"Maier","year":"2018"},{"key":"pmbaccccebib31","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1002\/mp.13274","type":"journal-article","article-title":"Real-time scatter estimation for medical ct using the deep scatter estimation: method and robustness analysis with respect to different anatomies, dose levels, tube voltages, and data truncation","volume":"46","author":"Maier","year":"2019","journal-title":"Med. Phys."},{"key":"pmbaccccebib32","doi-asserted-by":"publisher","first-page":"4495","DOI":"10.1088\/0031-9155\/55\/16\/S05","type":"journal-article","article-title":"Variance reduction techniques for fast monte carlo cbct scatter correction calculations","volume":"55","author":"Mainegra-Hing","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib33","doi-asserted-by":"publisher","first-page":"S10","DOI":"10.1016\/j.ijrobp.2009.07.1754","type":"journal-article","article-title":"Use of normal tissue complication probability models in the clinic","volume":"76","author":"Marks","year":"2010","journal-title":"Int. J. Radiat. Oncol.* Biol.* Phys."},{"key":"pmbaccccebib34","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1002\/acm2.13399","type":"journal-article","article-title":"Prospects for daily online adaptive radiotherapy via ethos for prostate cancer patients without nodal involvement using unedited cbct auto-segmentation","volume":"22","author":"Moazzezi","year":"2021","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaccccebib35","doi-asserted-by":"publisher","first-page":"1991","DOI":"10.1118\/1.3693050","type":"journal-article","article-title":"Quantitative cone-beam CT imaging in radiation therapy using planning ct as a prior: first patient studies","volume":"39","author":"Niu","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaccccebib36","doi-asserted-by":"publisher","first-page":"5395","DOI":"10.1118\/1.3483260","type":"journal-article","article-title":"Shading correction for on-board cone-beam ct in radiation therapy using planning MDCT images","volume":"37","author":"Niu","year":"2010","journal-title":"Med. Phys."},{"key":"pmbaccccebib37","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1118\/1.3679865","type":"journal-article","article-title":"Fast compressed sensing-based cbct reconstruction using barzilai-borwein formulation for application to on-line igrt","volume":"39","author":"Park","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaccccebib38","doi-asserted-by":"publisher","first-page":"4449","DOI":"10.1118\/1.4923179","type":"journal-article","article-title":"Proton dose calculation on scatter-corrected cbct image: feasibility study for adaptive proton therapy","volume":"42","author":"Park","year":"2015","journal-title":"Med. Phys."},{"key":"pmbaccccebib39","doi-asserted-by":"publisher","first-page":"e427","DOI":"10.1016\/j.ijrobp.2012.04.003","type":"journal-article","article-title":"Automatic segmentation and online virtualct in head-and-neck adaptive radiation therapy","volume":"84","author":"Peroni","year":"2012","journal-title":"Int. J. Radiat. Oncol.* Biol.* Phys."},{"key":"pmbaccccebib40","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/489\/1\/012079","type":"journal-article","article-title":"The reconstruction toolkit (RTK), an open-source cone-beam CT reconstruction toolkit based on the insight toolkit (ITK)","volume":"489","author":"Rit","year":"2014","journal-title":"J. Phys. Conf. Ser."},{"key":"pmbaccccebib41","doi-asserted-by":"publisher","first-page":"234","DOI":"10.48550\/arXiv.1505.04597","type":"conference-proceedings","article-title":"U-net: convolutional networks for biomedical image segmentation","author":"Ronneberger","year":"2015"},{"key":"pmbaccccebib42","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.phro.2020.12.004","type":"journal-article","article-title":"Clinical implementation of artificial intelligence-driven cone-beam computed tomography-guided online adaptive radiotherapy in the pelvic region","volume":"17","author":"Sibolt","year":"2021","journal-title":"Phys. Imaging Radiat. Oncol."},{"key":"pmbaccccebib43","doi-asserted-by":"publisher","first-page":"6565","DOI":"10.1088\/0031-9155\/59\/21\/6565","type":"journal-article","article-title":"A low-complexity 2-point step size gradient projection method with selective function evaluations for smoothed total variation based cbct reconstructions","volume":"59","author":"Song","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib44","doi-asserted-by":"publisher","first-page":"5781","DOI":"10.1088\/0031-9155\/61\/15\/5781","type":"journal-article","article-title":"Hounsfield unit recovery in clinical cone beam ct images of the thorax acquired for image guided radiation therapy","volume":"61","author":"Thing","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib45","article-title":"Instance normalization: the missing ingredient for fast stylization","author":"Ulyanov","year":"2016","type":"preprint"},{"key":"pmbaccccebib46","doi-asserted-by":"publisher","first-page":"404","DOI":"10.14338\/IJPT-14-00024.1","type":"journal-article","article-title":"Cone-beam computed tomography and deformable registration-based \u2018dose of the day\u2019 calculations for adaptive proton therapy","volume":"2","author":"Veiga","year":"2015","journal-title":"Int. J. Part. Ther."},{"key":"pmbaccccebib47","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/j.ijrobp.2016.01.055","type":"journal-article","article-title":"First clinical investigation of cone beam computed tomography and deformable registration for adaptive proton therapy for lung cancer","volume":"95","author":"Veiga","year":"2016","journal-title":"Int. J. Radiat. Oncol.* Biol.* Phys."},{"key":"pmbaccccebib48","doi-asserted-by":"publisher","DOI":"10.1118\/1.4864240","type":"journal-article","article-title":"Toward adaptive radiotherapy for head and neck patients: feasibility study on using CT-to-CBCT deformable registration for \u2018dose of the day\u2019 calculations","volume":"41","author":"Veiga","year":"2014","journal-title":"Med. Phys."},{"key":"pmbaccccebib49","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1120\/jacmp.v17i2.5819","type":"journal-article","article-title":"Quantitative assessment of anatomical change using a virtual proton depth radiograph for adaptive head and neck proton therapy","volume":"17","author":"Wang","year":"2016","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaccccebib50","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab6240","type":"journal-article","article-title":"Convolutional neural network enhancement of fast-scan low-dose cone-beam ct images for head and neck radiotherapy","volume":"65","author":"Yuan","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbaccccebib51","doi-asserted-by":"publisher","first-page":"2223","DOI":"10.48550\/arXiv.1703.10593","type":"conference-proceedings","article-title":"Unpaired image-to-image translation using cycle-consistent adversarial networks","author":"Zhu","year":"2017"},{"key":"pmbaccccebib52","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.phro.2017.09.002","type":"journal-article","article-title":"Decomposing a prior-ct-based cone-beam ct projection correction algorithm into scatter and beam hardening components","volume":"3","author":"Z\u00f6llner","year":"2017","journal-title":"Phys. and Imaging Radiat. Oncol."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:23:00Z","timestamp":1778775780000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acccce"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,11]]},"references-count":52,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2023,5,11]]},"published-print":{"date-parts":[[2023,5,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/acccce","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,11]]},"assertion":[{"value":"Feasibility of CycleGAN enhanced low dose CBCT imaging for prostate radiotherapy dose calculation","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2022-12-07","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-04-13","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-05-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}