{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T18:09:07Z","timestamp":1778782147990,"version":"3.51.4"},"reference-count":15,"publisher":"IOP Publishing","issue":"10","license":[{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2023,5,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Purpose<\/jats:italic>\n                    . Accurate image registration is an important step in online image-guided adaptive radiotherapy. The aim of this study was to investigate the effects of different factors on registration accuracy in a magnetic resonance (MR)-guided adaptive radiotherapy workflow.\n                    <jats:italic>Materials and Methods<\/jats:italic>\n                    . A thorax motion phantom was used to obtain computed tomography (CT) simulations in 8 different motion modes and to generate 8 reference plans. Daily pretreatment online MR images were obtained at 5 different positions in each reference plan. Online MR and CT simulations were separately registered using bone structures and the gross tumor volume (GTV) as ROIs, and the image shift distance was recorded by the online treatment planning system. The difference between the shift distance and the real isocentric distance was the registration error. The registration error was analyzed, and the effects of the setup position, motion mode and ROI selection on the registration error were investigated by multivariate analysis of variance.\n                    <jats:italic>Result<\/jats:italic>\n                    . The minimum values of registration error (\u0394\n                    <jats:italic>X<\/jats:italic>\n                    , \u0394\n                    <jats:italic>Y<\/jats:italic>\n                    , \u0394\n                    <jats:italic>Z<\/jats:italic>\n                    ) were \u22121.90 mm, \u22122.70 mm and \u22122.40 mm, respectively, and the maximum values were 1.70 mm, 4.30 mm and \u22120.90 mm. \u0394Y showed the maximum mean standard deviation of 1.25 mm, and \u0394\n                    <jats:italic>Z<\/jats:italic>\n                    showed the minimum mean standard deviation of 0.27 mm. The standard deviation of the registration error is largest in the inferior\/superior direction. The motion mode of the phantom and ROI selection were significantly correlated with \u0394\n                    <jats:italic>X<\/jats:italic>\n                    , \u0394\n                    <jats:italic>Y<\/jats:italic>\n                    , and \u0394\n                    <jats:italic>Z<\/jats:italic>\n                    (\n                    <jats:italic>p<\/jats:italic>\n                    &lt; 0.05).\n                    <jats:italic>Conclusion<\/jats:italic>\n                    . The registration result with the spine as the selected ROI was better than that with the GTV as the ROI. In 1.5 T MR-linac clinical treatment, more attention should be given to patient movement repeatability and to controlling the intrafractional motion as much as possible. It is not recommended to make the GTV-PTV margin expansion less than 2 mm for MR-linac.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/accef9","type":"journal-article","created":{"date-parts":[[2023,5,12]],"date-time":"2023-05-12T07:33:19Z","timestamp":1683876799000},"page":"10NT02","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Influence of different factors on registration error in a 1.5 T MR-guided linac"],"prefix":"10.1088","volume":"68","author":[{"given":"Peijun","family":"Yin","sequence":"first","affiliation":[{"name":"Shandong Normal University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gang","family":"Yu","sequence":"additional","affiliation":[{"name":"Shandong Normal University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chuanke","family":"Hou","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2544-3927","authenticated-orcid":true,"given":"Xuechun","family":"Liu","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5868-7229","authenticated-orcid":true,"given":"Mengdi","family":"Sun","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kuo","family":"Li","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhen","family":"Cui","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pei","family":"Liu","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xihua","family":"Shi","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Zhang","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukai","family":"Chen","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bingjie","family":"Pi","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong","family":"Yin","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhenjiang","family":"Li","sequence":"additional","affiliation":[{"name":"Shandong First Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2023,5,11]]},"reference":[{"key":"pmbaccef9bib1","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.tipsro.2020.01.001","type":"journal-article","article-title":"Laser-free pelvic alignment in an online adaptive radiotherapy environment","volume":"13","author":"Barnes","year":"2020","journal-title":"Tech. Innov. Patient Support Radiat. Oncol."},{"key":"pmbaccef9bib2","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.ejmp.2017.12.007","type":"journal-article","article-title":"The influence of the image registration method on the adaptive radiotherapy. a proof of the principle in a selected case of prostate IMRT","volume":"45","author":"Berenguer","year":"2018","journal-title":"Phys. Med."},{"key":"pmbaccef9bib3","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1159\/000511114","type":"journal-article","article-title":"CT and MRI image fusion error: an analysis of Co-Registration error using commercially available deep brain stimulation surgical planning software","volume":"99","author":"Burke","year":"2021","journal-title":"Stereotact. Funct. Neurosurg."},{"key":"pmbaccef9bib4","doi-asserted-by":"publisher","first-page":"e0193809","DOI":"10.1371\/journal.pone.0193809","type":"journal-article","article-title":"Assessment of image co-registration accuracy for frameless gamma knife surgery","volume":"13","author":"Chung","year":"2018","journal-title":"PLoS One"},{"key":"pmbaccef9bib5","doi-asserted-by":"publisher","first-page":"e46","DOI":"10.1016\/j.prro.2018.08.010","type":"journal-article","article-title":"Dosimetric benefits and practical pitfalls of daily online adaptive MRI-guided stereotactic radiation therapy for pancreatic cancer","volume":"9","author":"El-Bared","year":"2019","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbaccef9bib6","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1093\/jrr\/rrab078","type":"journal-article","article-title":"Evaluation of performance of pelvic CT-MR deformable image registration using two software programs","volume":"62","author":"Ishida","year":"2021","journal-title":"J. Radiat. Res."},{"key":"pmbaccef9bib7","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1111\/joim.12516","type":"journal-article","article-title":"The development of the MRI linac system for online MRI-guided radiotherapy: a clinical update","volume":"280","author":"Lagendijk","year":"2016","journal-title":"J. Intern. Med."},{"key":"pmbaccef9bib8","doi-asserted-by":"publisher","first-page":"5479","DOI":"10.1002\/mp.15057","type":"journal-article","article-title":"Technical Note: End-to-end verification of an MR-Linac using a dynamic motion phantom","volume":"48","author":"Liu","year":"2021","journal-title":"Med. Phys."},{"key":"pmbaccef9bib9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13014-018-0986-1","type":"journal-article","article-title":"Comparison of carina-based versus bony anatomy-based registration for setup verification in esophageal cancer radiotherapy","volume":"13","author":"Machiels","year":"2018","journal-title":"Radiat. Oncol."},{"key":"pmbaccef9bib10","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1111\/j.1754-9485.2010.02171.x","type":"journal-article","article-title":"Effect of lateral target motion on image registration accuracy in CT-guided helical tomotherapy: a phantom study","volume":"54","author":"Medwig","year":"2010","journal-title":"J. Med. Imaging Radiat Oncol."},{"key":"pmbaccef9bib11","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.radonc.2018.03.015","type":"journal-article","article-title":"Influence of deformable image registration on 4D dose simulation for extracranial SBRT: a multi-registration framework study","volume":"127","author":"Mogadas","year":"2018","journal-title":"Radiother. Oncol."},{"key":"pmbaccef9bib12","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1118\/1.4938412","type":"journal-article","article-title":"Effect of deformable registration uncertainty on lung SBRT dose accumulation","volume":"43","author":"Samavati","year":"2016","journal-title":"Med. Phys."},{"key":"pmbaccef9bib13","doi-asserted-by":"publisher","first-page":"3674","DOI":"10.1118\/1.4734933","type":"journal-article","article-title":"SU-E-J-97: evaluation of multi-modality (CT\/MR\/PET) image registration accuracy in radiotherapy planning","volume":"39","author":"Sethi","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaccef9bib14","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1016\/j.ijrobp.2017.11.009","type":"journal-article","article-title":"Magnetic resonance imaging-guided radiation therapy: a short strengths, weaknesses, opportunities, and threats analysis","volume":"101","author":"van Herk","year":"2018","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbaccef9bib15","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.radonc.2019.06.007","type":"journal-article","article-title":"MRI-guided mid-position liver radiotherapy: validation of image processing and registration steps","volume":"138","author":"Van de Lindt","year":"2019","journal-title":"Radiother. Oncol."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/accef9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/accef9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/accef9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/accef9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:18:28Z","timestamp":1778779108000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/accef9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,11]]},"references-count":15,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2023,5,11]]},"published-print":{"date-parts":[[2023,5,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/accef9","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,11]]},"assertion":[{"value":"Influence of different factors on registration error in a 1.5 T MR-guided linac","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2023-01-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-04-20","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-05-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}