{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:15:01Z","timestamp":1778778901952,"version":"3.51.4"},"reference-count":71,"publisher":"IOP Publishing","issue":"18","license":[{"start":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T00:00:00Z","timestamp":1694649600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T00:00:00Z","timestamp":1694649600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"UHDpulse","award":["18HLT04"],"award-info":[{"award-number":["18HLT04"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2023,9,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    This work presents a method for enhanced detection, imaging, and measurement of the thermal neutron flux.\n                    <jats:italic>Approach<\/jats:italic>\n                    . Measurements were performed in a water tank, while the detector is positioned out-of-field of a 20 MeV ultra-high pulse dose rate electron beam. A semiconductor pixel detector Timepix3 with a silicon sensor partially covered by a\n                    <jats:sup>6<\/jats:sup>\n                    LiF neutron converter was used to measure the flux, spatial, and time characteristics of the neutron field. To provide absolute measurements of thermal neutron flux, the detection efficiency calibration of the detectors was performed in a reference thermal neutron field. Neutron signals are recognized and discriminated against other particles such as gamma rays and x-rays. This is achieved by the resolving power of the pixel detector using machine learning algorithms and high-resolution pattern recognition analysis of the high-energy tracks created by thermal neutron interactions in the converter.\n                    <jats:italic>Main results<\/jats:italic>\n                    . The resulting thermal neutrons equivalent dose was obtained using conversion factor (2.13(10) pSv\u00b7cm\n                    <jats:sup>2<\/jats:sup>\n                    ) from thermal neutron fluence to thermal neutron equivalent dose obtained by Monte Carlo simulations. The calibrated detectors were used to characterize scattered radiation created by electron beams. The results at 12.0 cm depth in the beam axis inside of the water for a delivered dose per pulse of 1.85 Gy (pulse length of 2.4\n                    <jats:italic>\u03bc<\/jats:italic>\n                    s) at the reference depth, showed a contribution of flux of 4.07(8) \u00d7 10\n                    <jats:sup>3<\/jats:sup>\n                    particles\u00b7cm\n                    <jats:sup>\u22122<\/jats:sup>\n                    \u00b7s\n                    <jats:sup>\u22121<\/jats:sup>\n                    and equivalent dose of 1.73(3) nSv per pulse, which is lower by \u223c9 orders of magnitude than the delivered dose.\n                    <jats:italic>Significance<\/jats:italic>\n                    . The presented methodology for in-water measurements and identification of characteristic thermal neutrons tracks serves for the selective quantification of equivalent dose made by thermal neutrons in out-of-field particle therapy.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/acf2e1","type":"journal-article","created":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T18:42:22Z","timestamp":1692729742000},"page":"185017","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":10,"title":["Thermal neutron detection and track recognition method in reference and out-of-field radiotherapy FLASH electron fields using Timepix3 detectors"],"prefix":"10.1088","volume":"68","author":[{"given":"Cristina","family":"Oancea","sequence":"first","affiliation":[{"name":"ADVACAM, U Pergamenky 12, 170 00 Prague 7,"},{"name":"University of Bucharest"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jaroslav","family":"Solc","sequence":"additional","affiliation":[{"name":"Czech Metrology Institute, Okruzni 31, 638 00 Brno,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6429-4122","authenticated-orcid":false,"given":"Alexandra","family":"Bourgouin","sequence":"additional","affiliation":[{"name":"Dosimetry for Radiation Therapy and Diagnostic Radiology, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, 38116,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4398-1553","authenticated-orcid":false,"given":"Carlos","family":"Granja","sequence":"additional","affiliation":[{"name":"ADVACAM, U Pergamenky 12, 170 00 Prague 7,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Jakubek","sequence":"additional","affiliation":[{"name":"ADVACAM, U Pergamenky 12, 170 00 Prague 7,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiri","family":"Pivec","sequence":"additional","affiliation":[{"name":"ADVACAM, U Pergamenky 12, 170 00 Prague 7,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Felix","family":"Riemer","sequence":"additional","affiliation":[{"name":"Deutsches Elektronen-Synchrotron DESY, Platanenallee 6, 15738 Zeuthen,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zdenek","family":"Vykydal","sequence":"additional","affiliation":[{"name":"Czech Metrology Institute, Okruzni 31, 638 00 Brno,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven","family":"Worm","sequence":"additional","affiliation":[{"name":"Deutsches Elektronen-Synchrotron DESY, Platanenallee 6, 15738 Zeuthen,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lukas","family":"Marek","sequence":"additional","affiliation":[{"name":"ADVACAM, U Pergamenky 12, 170 00 Prague 7,"},{"name":"Charles University"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2023,9,14]]},"reference":[{"key":"pmbacf2e1bib1","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1118\/1.597140","type":"journal-article","article-title":"Neutron fluxes in radiotherapy rooms","volume":"20","author":"Agosteo","year":"1993","journal-title":"Med. Phys."},{"key":"pmbacf2e1bib2","author":"Attix","year":"2008","type":"book"},{"key":"pmbacf2e1bib3","doi-asserted-by":"publisher","author":"Abadi","year":"2022","DOI":"10.48550\/arXiv.1605.08695","type":"other"},{"key":"pmbacf2e1bib4","volume":"10","author":"Aggarwal","year":"2018","type":"book"},{"key":"pmbacf2e1bib5","doi-asserted-by":"publisher","first-page":"085013","DOI":"10.1088\/1361-6560\/AC5DE8","type":"journal-article","article-title":"Characterization of the PTB ultra-high pulse dose rate reference electron beam","volume":"67","author":"Bourgouin","year":"2022a","journal-title":"Phys. Med. Biol."},{"key":"pmbacf2e1bib6","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac950b","type":"journal-article","article-title":"Absorbed-dose-to-water measurement using alanine in ultra-high-pulse-dose-rate electron beams","volume":"67","author":"Bourgouin","year":"2022b","journal-title":"Phys. Med. Biol."},{"key":"pmbacf2e1bib7","doi-asserted-by":"publisher","first-page":"400","DOI":"10.3389\/fphy.2020.567340","type":"journal-article","article-title":"Calorimeter for real-time dosimetry of pulsed ultra-high dose rate electron beams","volume":"8","author":"Bourgouin","year":"2020","journal-title":"Front. Phys."},{"key":"pmbacf2e1bib8","doi-asserted-by":"publisher","first-page":"6635","DOI":"10.1002\/mp.15899","type":"journal-article","article-title":"The probe-format graphite calorimeter, Aerrow, for absolute dosimetry in ultrahigh pulse dose rate electron beams","volume":"49","author":"Bourgouin","year":"2022c","journal-title":"Med. Phys."},{"key":"pmbacf2e1bib9","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.radmeas.2013.06.010","type":"journal-article","article-title":"Radiotherapy out-of-field dosimetry: Experimental and computational results for photons in a water tank","volume":"57","author":"Bordy","year":"2013","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib10","author":"Campbell","year":"2013","type":"other"},{"key":"pmbacf2e1bib11","doi-asserted-by":"publisher","first-page":"2931","DOI":"10.1016\/j.nds.2006.11.001","type":"journal-article","article-title":"ENDF\/B-VII.0: next generation evaluated nuclear data library for nuclear science and technology","volume":"107","author":"Chadwick","year":"2006","journal-title":"Nucl. Data Sheets"},{"key":"pmbacf2e1bib12","doi-asserted-by":"publisher","DOI":"10.48550\/arxiv.2209.01178","type":"journal-article","article-title":"Measurement of the time structure of FLASH beams using prompt gamma rays and secondary neutrons as surrogates","author":"Charyyev","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbacf2e1bib13","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.ejmp.2020.02.008","type":"journal-article","article-title":"Assessment of out-of-field doses in radiotherapy treatments of paediatric patients using Monte Carlo methods and measurements","volume":"71","author":"Cravo S\u00e1","year":"2020","journal-title":"Phys. Med."},{"key":"pmbacf2e1bib14","author":"Conlin","year":"2018","type":"other"},{"key":"pmbacf2e1bib15","doi-asserted-by":"publisher","first-page":"1185","DOI":"10.1016\/S0360-3016(98)00162-X","type":"journal-article","article-title":"In vivo neutron dosimetry during high-energy bremsstrahlung radiotherapy","volume":"41","author":"D\u2019Errico","year":"1998","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbacf2e1bib16","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2021.106665","type":"journal-article","article-title":"Fetus dose calculation during proton therapy of pregnant phantoms using MCNPX and MCNP6.2 codes","volume":"149","author":"de Saint-Hubert","year":"2021","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib17","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.radmeas.2012.11.022","type":"journal-article","article-title":"Superheated emulsions and track etch detectors for photoneutron measurements","volume":"57","author":"di Fulvio","year":"2013","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib18","doi-asserted-by":"publisher","DOI":"10.1051\/epjconf\/201817001004","type":"journal-article","article-title":"Neutron detection devices with 6LiF converter layers","volume":"170","author":"Finocchiaro","year":"2018","journal-title":"EPJ Web Conf."},{"key":"pmbacf2e1bib19","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2020.164901","type":"journal-article","article-title":"Wide-range tracking and LET-spectra of energetic light and heavy charged particles","volume":"988","author":"Granja","year":"2021","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbacf2e1bib20","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/18\/01\/P01003","type":"journal-article","article-title":"Detection of fast neutrons with the pixel detector Timepix3","volume":"18","author":"Granja","year":"2023","journal-title":"J. Instrum."},{"key":"pmbacf2e1bib21","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/17\/03\/C03019","type":"journal-article","article-title":"MiniPIX Timepix3 \u2014 a miniaturized radiation camera with onboard data processing for online characterization of wide-intensity mixed-radiation fields","volume":"17","author":"Granja","year":"2022","journal-title":"J. Instrum."},{"key":"pmbacf2e1bib22","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/17\/01\/C01066","type":"journal-article","article-title":"A miniaturized radiation monitor for continuous dosimetry and particle identification in space","volume":"17","author":"Gohl","year":"2022","journal-title":"J. Instrum."},{"key":"pmbacf2e1bib23","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.nima.2018.08.014","type":"journal-article","article-title":"Resolving power of pixel detector timepix for wide-range electron, proton and ion detection","volume":"908","author":"Granja","year":"2018","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbacf2e1bib24","type":"journal-article","article-title":"Evaluation of measurement data\u2014Guide to the expression of uncertainty in measurement","volume":"134","author":"GUM-2008","year":"2008","journal-title":"Int. Organ. Stand. Geneva"},{"key":"pmbacf2e1bib25","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1016\/j.ejmp.2017.02.001","type":"journal-article","article-title":"Out-of-field doses in radiotherapy: input to epidemiological studies and dose-risk models","volume":"42","author":"Harrison","year":"2017","journal-title":"Physica Med."},{"key":"pmbacf2e1bib26","first-page":"2","type":"book","volume":"37","author":"ICRP","year":"2007"},{"key":"pmbacf2e1bib27","first-page":"2","type":"book","volume":"40","author":"ICRP","year":"2010"},{"key":"pmbacf2e1bib28","first-page":"13","type":"journal-article","article-title":"Operational quantities for external radiation exposure","volume":"20","author":"ICRU","year":"2020","journal-title":"ICRU Rep. 95 J. ICRU"},{"key":"pmbacf2e1bib29","first-page":"p 2","type":"book","volume":"38","author":"ICRP","year":"2009"},{"key":"pmbacf2e1bib30","doi-asserted-by":"publisher","DOI":"10.1109\/NSSMIC.2009.5402420","type":"journal-article","article-title":"Neutron detector based on TimePix pixel device with micrometer spatial resolution","volume":"7449","author":"Jakubek","year":"2009","journal-title":"SPIE Proc."},{"key":"pmbacf2e1bib31","doi-asserted-by":"publisher","first-page":"S262","DOI":"10.1016\/j.nima.2010.06.183","type":"journal-article","article-title":"Precise energy calibration of pixel detector working in time-over-threshold mode","volume":"633","author":"Jakubek","year":"2011","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbacf2e1bib39","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.1118\/1.2898144","type":"journal-article","article-title":"Measurement of the neutron leakage from a dedicated intraoperative radiation therapy electron linear accelerator and a conventional linear accelerator for 9, 12, 15(16), and 18(20) MeV electron energies","volume":"35","author":"Jaradat","year":"2008","journal-title":"Med. Phys."},{"key":"pmbacf2e1bib32","author":"Khan","year":"2014","type":"book"},{"key":"pmbacf2e1bib33","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1093\/rpd\/ncu192","type":"journal-article","article-title":"Spectral fluence of neutrons generated by radiotherapeutic linacs","volume":"163","author":"Kr\u00e1l\u00edk","year":"2015","journal-title":"Radiat. Prot. Dosim."},{"key":"pmbacf2e1bib34","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/11\/12\/C12026","type":"journal-article","article-title":"Development and characterization of high-resolution neutron pixel detectors based on Timepix read-out chips","volume":"11","author":"Krejci","year":"2016","journal-title":"J. Instrum."},{"key":"pmbacf2e1bib35","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac594e","type":"journal-article","article-title":"Response of diamond detectors in ultra-high dose-per-pulse electron beams for dosimetry at FLASH radiotherapy","volume":"67","author":"Kranzer","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbacf2e1bib36","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.rpor.2012.06.004","type":"journal-article","article-title":"Thermal and resonance neutrons generated by various electron and x-ray therapeutic beams from medical linacs installed in polish oncological centers","volume":"1","author":"Konefa\u0142","year":"2012","journal-title":"Rep. Pract. Oncol. Radiother."},{"key":"pmbacf2e1bib37","doi-asserted-by":"publisher","DOI":"10.1016\/J.APRADISO.2020.109206","type":"journal-article","article-title":"Radioactivity induced in new-generation cardiac implantable electronic devices during high-energy x-ray irradiation","volume":"163","author":"Konefa\u0142","year":"2020","journal-title":"Appl. Radiat. Isotopes: Incl. Data, Instrum. Methods Agric., Ind. Med."},{"key":"pmbacf2e1bib38","doi-asserted-by":"publisher","first-page":"1904","DOI":"10.1016\/j.apradiso.2011.03.028","type":"journal-article","article-title":"Epithermal neutron beam interference with cardiac pacemakers","volume":"69","author":"Koivunoro","year":"2011","journal-title":"Appl. Radiat. Isot."},{"key":"pmbacf2e1bib40","doi-asserted-by":"publisher","first-page":"3386","DOI":"10.3389\/fonc.2022.904563","type":"journal-article","article-title":"Out-of-field doses produced by a proton scanning beam inside pediatric anthropomorphic phantoms and their comparison with different photon modalities","volume":"12","author":"Kne\u017eevi\u0107","year":"2022","journal-title":"Front. Oncol."},{"key":"pmbacf2e1bib41","author":"Marek","year":"2023","type":"web-resource"},{"key":"pmbacf2e1bib42","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.ejmp.2020.10.016","type":"journal-article","article-title":"The impact of treatment parameter variation on secondary neutron spectra in high-energy electron beam radiotherapy","volume":"80","author":"Mathew","year":"2020","journal-title":"Phys. Med."},{"key":"pmbacf2e1bib43","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.radmeas.2014.04.026","type":"journal-article","article-title":"Out-of-field dose measurements in radiotherapy\u2014an overview of activity of EURADOS working group 9: Radiation protection in medicine","volume":"71","author":"Miljani\u0107","year":"2014","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib44","doi-asserted-by":"publisher","first-page":"12","DOI":"10.13182\/NSE70-A18875","type":"journal-article","article-title":"The Thermal-Neutron-Absorption Cross Sections of 6Li and 10B","volume":"40","author":"Meadows","year":"1970","journal-title":"Nuclear Science and Engineering"},{"key":"pmbacf2e1bib45","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1016\/j.radmeas.2017.04.015","type":"journal-article","article-title":"Out-of-field dosimetry and 2nd cancer risk assessment of child patients under proton therapy using a TLD-based microdosimeter","volume":"106","author":"Mukherjee","year":"2017","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib46","article-title":"Neutron contamination from medical electron accelerators: recommendations of the national council on radiation protection and measurements","author":"NCRP","year":"1984","type":"report"},{"key":"pmbacf2e1bib47","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/18\/01\/C01022","type":"journal-article","article-title":"Spectral tracking of proton beams by the Timepix3 detector with GaAs, CdTe and Si sensors","volume":"18","author":"Novak","year":"2023","journal-title":"J. Instrum."},{"key":"pmbacf2e1bib48","article-title":"Rectified linear units improve restricted Boltzmann machine","author":"Nair","year":"2010","type":"conference-proceedings"},{"key":"pmbacf2e1bib49","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/17\/01\/C01003","type":"journal-article","article-title":"Stray radiation produced in FLASH electron beams characterized by the MiniPIX Timepix3 Flex detector","volume":"17","author":"Oancea","year":"2022","journal-title":"J. Instrum."},{"key":"pmbacf2e1bib50","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2023.102529","type":"journal-article","article-title":"Out-of-field measurements and simulations of a proton pencil beam in a wide range of dose rates using a Timepix3 detector: Dose rate, flux and LET","volume":"106","author":"Oancea","year":"2023","journal-title":"Phys. Med."},{"key":"pmbacf2e1bib51","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aae656","type":"journal-article","article-title":"Perturbations of radiation field caused by titanium dental implants in pencil proton beam therapy","volume":"63","author":"Oancea","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbacf2e1bib52","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.radmeas.2018.01.003","type":"journal-article","article-title":"LET spectra behind high-density titanium and stainless steel hip implants irradiated with a therapeutic proton beam","volume":"110","author":"Oancea","year":"2018a","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib53","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/9\/05\/C05013","type":"journal-article","article-title":"Timepix3: a 65K channel hybrid pixel readout chip with simultaneous ToA\/ToT and sparse readout","volume":"9","author":"Poikela","year":"2014","journal-title":"J. Instrum."},{"key":"pmbacf2e1bib54","doi-asserted-by":"publisher","first-page":"2996","DOI":"10.1200\/JCO.2009.27.4498","type":"journal-article","article-title":"Critical impact of radiotherapy protocol compliance and quality in the treatment of advanced head and neck cancer: Results from TROG 02.02","volume":"28","author":"Peters","year":"2010","journal-title":"J. Clin. Oncol."},{"key":"pmbacf2e1bib55","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.radmeas.2017.10.012","type":"journal-article","article-title":"Timepix detector as a tool for x-ray and gamma dosimetry","volume":"107","author":"Rubovi\u010d","year":"2017","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib56","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2019.106211","type":"journal-article","article-title":"Medipix detectors in radiation therapy for advanced quality-assurance","volume":"130","author":"Rosenfeld","year":"2020","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib57","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/0168-9002(87)91101-6","type":"journal-article","article-title":"Superheated drop detector: a potential tool in neutron research","volume":"255","author":"Roy","year":"1987","journal-title":"Nucl. Instrum. Methods Phys. Res., Sect. A"},{"key":"pmbacf2e1bib58","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-018-34643-w","type":"journal-article","article-title":"Opportunistic dose amplification for proton and carbon ion therapy via capture of internally generated thermal neutrons","volume":"8","author":"Safavi-Naeini","year":"2018","journal-title":"Sci. Rep. 2018 8:1"},{"key":"pmbacf2e1bib59","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0181281","type":"journal-article","article-title":"Monte Carlo studies on neutron interactions in radiobiological experiments","volume":"12","author":"Shahmohammadi Beni","year":"2017","journal-title":"PLoS One"},{"key":"pmbacf2e1bib60","doi-asserted-by":"publisher","first-page":"235","DOI":"10.3389\/fonc.2015.00235","type":"journal-article","article-title":"The impact of neutrons in clinical proton therapy","volume":"5","author":"Schneider","year":"2015","journal-title":"Front. Oncol."},{"key":"pmbacf2e1bib61","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/12\/03\/P03003","type":"journal-article","article-title":"Traceable charge measurement of the pulses of a 27 MeV electron beam from a linear accelerator","volume":"12","author":"Sch\u00fcller","year":"2017","journal-title":"JINST"},{"key":"pmbacf2e1bib62","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1007\/978-981-10-9023-3_109","type":"journal-article","article-title":"The metrological electron accelerator facility (MELAF) for research in dosimetry for radiotherapy","volume":"68","author":"Sch\u00fcller","year":"2019","journal-title":"IFMBE Proc."},{"key":"pmbacf2e1bib63","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.ejmp.2022.08.002","type":"journal-article","article-title":"Monte carlo modelling of pixel clusters in timepix detectors using the MCNP code","volume":"101","author":"\u0160olc","year":"2022","journal-title":"Phys. Med."},{"key":"pmbacf2e1bib64","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/11\/12\/C12065","type":"journal-article","article-title":"USB 3.0 readout and time-walk correction method for Timepix3 detector","volume":"11","author":"Turecek","year":"2016","journal-title":"J. Instrum."},{"key":"pmbacf2e1bib65","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1016\/S1350-4487(98)00071-7","type":"journal-article","article-title":"A combined use of the BD-PND and BDT bubble detectors in neutron dosimetry","volume":"29","author":"Vanhavere","year":"1998","journal-title":"Radiat. Meas."},{"key":"pmbacf2e1bib66","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1016\/S0168-9002(03)02013-8","type":"journal-article","article-title":"Neutron detection with a silicon PIN photodiode and 6LiF converter","volume":"512","author":"Voytchev","year":"2003","journal-title":"Nucl. Instrum. Methods Phys. Res., Sect. A"},{"key":"pmbacf2e1bib67","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1093\/rpd\/ncv504","type":"journal-article","article-title":"Measurement Of secondary neutrons generated during proton therapy","volume":"172","author":"Vykydal","year":"2016","journal-title":"Radiat. Prot. Dosim."},{"key":"pmbacf2e1bib68","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1093\/rpd\/ncx190","type":"journal-article","article-title":"Characterisation of the graphite moderated thermal neutron field at CMI","volume":"180","author":"Vykydal","year":"2018","journal-title":"Radiat. Prot. Dosim."},{"key":"pmbacf2e1bib69","author":"Werner","year":"2017","type":"other"},{"key":"pmbacf2e1bib70","doi-asserted-by":"publisher","author":"Werner","year":"2018","DOI":"10.2172\/1419730","type":"report"},{"key":"pmbacf2e1bib71","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2022.102513","type":"journal-article","article-title":"A review on fetal dose in Radiotherapy: A historical to contemporary perspective","volume":"105","author":"Wong","year":"2023","journal-title":"Phys. Med."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:45:24Z","timestamp":1778777124000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf2e1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,14]]},"references-count":71,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2023,9,14]]},"published-print":{"date-parts":[[2023,9,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/acf2e1","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,14]]},"assertion":[{"value":"Thermal neutron detection and track recognition method in reference and out-of-field radiotherapy FLASH electron fields using Timepix3 detectors","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-02-28","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-08-22","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-09-14","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}