{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:08:06Z","timestamp":1778778486079,"version":"3.51.4"},"reference-count":23,"publisher":"IOP Publishing","issue":"19","license":[{"start":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T00:00:00Z","timestamp":1695772800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T00:00:00Z","timestamp":1695772800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2023,10,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Treating multiple brain metastases in a single plan is a popular radiosurgery technique. However, targets positioned off-isocenter are subject to rotational uncertainties. This work introduces two new planning target volumes (PTVs) that address this increased uncertainty. The volume of normal tissue included in these PTVs when paired with optimized isocenters are evaluated and compared with conventional methods.\n                    <jats:italic>Approach.<\/jats:italic>\n                    Sets of 1000 random multi-target radiosurgery patients were simulated, each patient with a random number of spherical targets (2\u201310). Each target had a random volume (0.1\u201315 cc) and was randomly positioned between 5 and 50 mm or 100 mm from isocenter. Two new PTVs (\u2018LensPTV\u2019 and \u2018SwipePTV\u2019) and conventional isotropic PTVs were created using isocenters derived from the center-of-centroids, the center-of-mass, or optimized per PTV type. The total volume of normal tissue in the PTVs for each patient was calculated and compared using 1 mm translations and 0.5\u00b0, 1.0\u00b0, and 2.0\u00b0 rotations.\n                    <jats:italic>Main results.<\/jats:italic>\n                    Using the new PTVs and\/or using optimized isocenters decreased the total volume of normal tissue in the PTVs per patient. The SwipePTV, in particular, provided the greatest decrease. Compared to the SwipePTV, the LensPTV and the conventional isotropic PTV included an extra 0.68 and 0.73 cc of normal tissue per patient (median), respectively, when using 50 mm max distance to isocenter and 1\u00b0 max rotation angle. Under these conditions, 25% of patients had extra volume of normal tissue \u2265 0.96 and 1.04 cc. When using 100 mm max distance to isocenter and 2\u00b0 max rotation angle, 25% of patients had extra volume of normal tissue \u2265 4.35 and 5.75 cc.\n                    <jats:italic>Significance.<\/jats:italic>\n                    PTVs like those presented here, especially when paired with optimized isocenters, can decrease the total volume of included normal tissue and reduce the risk of toxicity without compromising target coverage.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/acf751","type":"journal-article","created":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T18:34:23Z","timestamp":1694025263000},"page":"195025","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Innovative margin design and optimized isocenter to minimize the normal tissue in target volumes for single-isocenter multi-target stereotactic radiosurgery"],"prefix":"10.1088","volume":"68","author":[{"given":"Adam D","family":"Yock","sequence":"first","affiliation":[{"name":"Vanderbilt University Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Beshoi","family":"Grees","sequence":"additional","affiliation":[{"name":"Vanderbilt University Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guozhen","family":"Luo","sequence":"additional","affiliation":[{"name":"Vanderbilt University Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2023,9,27]]},"reference":[{"key":"pmbacf751bib1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13014-021-01944-w","type":"journal-article","article-title":"Simultaneous radiosurgery for multiple brain metastases: technical overview of the UCLA experience","volume":"16","author":"Agazaryan","year":"2021","journal-title":"Radiat Oncol."},{"key":"pmbacf751bib2","doi-asserted-by":"publisher","first-page":"2483","DOI":"10.1001\/jama.295.21.2483","type":"journal-article","article-title":"Stereotactic radiosurgery plus whole-brain radiation therapy vs stereotactic radiosurgery alone for treatment of brain metastases: a randomized controlled trial","volume":"295","author":"Aoyama","year":"2006","journal-title":"JAMA"},{"key":"pmbacf751bib3","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1001\/jama.2016.9839","type":"journal-article","article-title":"Effect of radiosurgery alone vs radiosurgery with whole brain radiation therapy on cognitive function in patients with 1 to 3 brain metastases a randomized clinical trial","volume":"316","author":"Brown","year":"2016","journal-title":"JAMA\u2014J. Am. Med. Assoc."},{"key":"pmbacf751bib4","doi-asserted-by":"publisher","first-page":"1863","DOI":"10.1088\/0031-9155\/55\/7\/005","type":"journal-article","article-title":"Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study","volume":"55","author":"Cerv\u0129o","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"pmbacf751bib5","doi-asserted-by":"publisher","first-page":"2115","DOI":"10.1002\/mp.12262","type":"journal-article","article-title":"A statistical model for analyzing the rotational error of single isocenter for multiple targets technique","volume":"44","author":"Chang","year":"2017","journal-title":"Med. Phys."},{"key":"pmbacf751bib6","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.prro.2018.04.011","type":"journal-article","article-title":"Incorporating the rotational setup uncertainty into the planning target volume margin expansion for the single isocenter for multiple targets technique","volume":"8","author":"Chang","year":"2018","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbacf751bib7","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1016\/j.prro.2011.12.003","type":"journal-article","article-title":"Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy","volume":"2","author":"Clark","year":"2012","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbacf751bib8","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/j.ijrobp.2009.05.029","type":"journal-article","article-title":"Feasibility of single-isocenter volumetric modulated arc radiosurgery for treatment of multiple brain metastases","volume":"76","author":"Clark","year":"2010","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbacf751bib9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/mp.15294","type":"journal-article","article-title":"Optimization of treatment isocenter location in single-isocenter LINAC-based stereotactic radiosurgery for management of multiple brain metastases","volume":"48","author":"Cui","year":"2021","journal-title":"Med. Phys."},{"key":"pmbacf751bib10","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1120\/jacmp.v9i4.2828","type":"journal-article","article-title":"Simulation of intrafraction motion and overall geometric accuracy of a frameless intracranial radiosurgery process","volume":"9","author":"Feygelman","year":"2008","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbacf751bib11","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2022.02.003","type":"journal-article","article-title":"Radiation therapy for brain metastases: an astro clinical practice guideline","volume":"12","author":"Gondi","year":"2022","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbacf751bib12","doi-asserted-by":"publisher","first-page":"4197","DOI":"10.1118\/1.3190392","type":"journal-article","article-title":"Task Group 142 report: quality assurance of medical accelerators","volume":"36","author":"Klein","year":"2009","journal-title":"Med. Phys."},{"key":"pmbacf751bib13","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2021.09.007","type":"journal-article","article-title":"Practical considerations for single isocenter LINAC radiosurgery of multiple brain metastases","volume":"12","author":"Meeks","year":"2022","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbacf751bib14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/acm2.13853","type":"journal-article","article-title":"Optimization of isocenter position for multiple targets with nonuniform-margin expansion","volume":"24","author":"Miao","year":"2022","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbacf751bib15","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1002\/acm2.13081","type":"journal-article","article-title":"Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases","volume":"21","author":"Nakano","year":"2020","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbacf751bib16","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1002\/acm2.13322","type":"journal-article","article-title":"Radiobiological evaluation considering setup error on single-isocenter irradiation in stereotactic radiosurgery","volume":"22","author":"Nakano","year":"2021","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbacf751bib17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/noajnl\/vdaa034","type":"journal-article","article-title":"Multidisciplinary patient-centered management of brain metastases and future directions","volume":"2","author":"Palmer","year":"2020","journal-title":"Neuro-Oncol. Adv."},{"key":"pmbacf751bib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2021.05.031","type":"journal-article","article-title":"Use of genetic algorithm for PTV optimization in single isocenter multiple metastases radiosurgery treatments with Brainlab ElementsTM","volume":"86","author":"Rojas-L\u00f3pez","year":"2021","journal-title":"Phys. Med."},{"key":"pmbacf751bib19","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab9703","type":"journal-article","article-title":"Selection of single-isocenter for multiple-target stereotactic brain radiosurgery to minimize total margin volume","volume":"65","author":"Slagowski","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbacf751bib20","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/j.prro.2015.10.010","type":"journal-article","article-title":"Physics considerations for single-isocenter, volumetric modulated arc radiosurgery for treatment of multiple intracranial targets","volume":"6","author":"Stanhope","year":"2016","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbacf751bib21","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1038\/s41571-019-0320-3","type":"journal-article","article-title":"Current approaches to the management of brain metastases","volume":"17","author":"Suh","year":"2020","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"pmbacf751bib22","doi-asserted-by":"publisher","DOI":"10.3171\/2014.8.GKS141421","type":"journal-article","article-title":"Stereotactic radiosurgery for patients with multiple brain metastases: a case-matched study comparing treatment results for patients with 2\u20139 versus 10 or more tumors","volume":"121","author":"Yamamoto","year":"2014a","journal-title":"J. Neurosurg."},{"key":"pmbacf751bib23","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/S1470-2045(14)70061-0","type":"journal-article","article-title":"Stereotactic radiosurgery for patients with multiple brain metastases (JLGK0901): a multi-institutional prospective observational study","volume":"15","author":"Yamamoto","year":"2014b","journal-title":"Lancet Oncol."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:10:48Z","timestamp":1778775048000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/acf751"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,27]]},"references-count":23,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2023,9,27]]},"published-print":{"date-parts":[[2023,10,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/acf751","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,27]]},"assertion":[{"value":"Innovative margin design and optimized isocenter to minimize the normal tissue in target volumes for single-isocenter multi-target stereotactic radiosurgery","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2023-06-13","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-09-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-09-27","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}