{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T19:39:07Z","timestamp":1790105947467,"version":"4.0.1"},"reference-count":25,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2024,2,26]],"date-time":"2024-02-26T00:00:00Z","timestamp":1708905600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,2,26]],"date-time":"2024-02-26T00:00:00Z","timestamp":1708905600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Lanzhou City Youth Science and Technology Talent Innovation Project","award":["2023-QN-87"],"award-info":[{"award-number":["2023-QN-87"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["62101226"],"award-info":[{"award-number":["62101226"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2024,3,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    A direct comparison of the impact of RF coil design under specific absorption rate and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:msubsup>\n                            <mml:mi>B<\/mml:mi>\n                            <mml:mn>1<\/mml:mn>\n                            <mml:mo>+<\/mml:mo>\n                          <\/mml:msubsup>\n                          <mml:mi>rms<\/mml:mi>\n                        <\/mml:msub>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    limitations are investigated and quantified using RF coils of different geometries and topologies at 64 MHz and 128 MHz. The RF-induced\n                    <jats:italic>in vivo<\/jats:italic>\n                    electric field and power deposition of a 50 cm long pacemaker and 55 cm long deep brain stimulator (DBS) are evaluated within two anatomical models exposed with these RF coils. The associated uncertainty is quantified and analyzed under a fixed\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:msubsup>\n                            <mml:mi>B<\/mml:mi>\n                            <mml:mn>1<\/mml:mn>\n                            <mml:mo>+<\/mml:mo>\n                          <\/mml:msubsup>\n                          <mml:mi>rms<\/mml:mi>\n                        <\/mml:msub>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    incident and normal operating mode. For a fixed\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:msubsup>\n                            <mml:mi>B<\/mml:mi>\n                            <mml:mn>1<\/mml:mn>\n                            <mml:mo>+<\/mml:mo>\n                          <\/mml:msubsup>\n                          <mml:mi>rms<\/mml:mi>\n                        <\/mml:msub>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    incident, the\n                    <jats:italic>in vivo<\/jats:italic>\n                    incident field shows a much higher uncertainty (&gt;5.6 dB) to the RF coil diameter compared to other design parameters (e.g. &lt;2.2 dB for coil length and topology), while the associated uncertainty reduced greatly (e.g. &lt;1.5 dB) under normal operating mode exposure. Similar uncertainties are observed in the power deposition near the pacemaker and DBS electrode. Compared to the normal operating mode, applying a fixed\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:msubsup>\n                            <mml:mi>B<\/mml:mi>\n                            <mml:mn>1<\/mml:mn>\n                            <mml:mo>+<\/mml:mo>\n                          <\/mml:msubsup>\n                          <mml:mi>rms<\/mml:mi>\n                        <\/mml:msub>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    field to the untested implant will lead to a large variation in the induced incident and power deposition of the implant, as a result, a larger safe margin when different coil designs (e.g. coil diameter) are considered.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ad2714","type":"journal-article","created":{"date-parts":[[2024,2,7]],"date-time":"2024-02-07T17:22:46Z","timestamp":1707326566000},"page":"055021","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Impact of MRI RF coil design on the RF-induced heating of medical implants: fixed\n                    <i>B<\/i>\n                    <sub>1<\/sub>\n                    <sup>+<\/sup>\n                    <sub>rms<\/sub>\n                    exposure versus normal operating mode"],"prefix":"10.1088","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3859-2684","authenticated-orcid":false,"given":"Aiping","family":"Yao","sequence":"first","affiliation":[{"name":"Nanchang University"},{"name":"Nanchang University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zihan","family":"Li","sequence":"additional","affiliation":[{"name":"Lanzhou University"},{"name":"Lanzhou University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4370-0395","authenticated-orcid":false,"given":"Mingjuan","family":"Ma","sequence":"additional","affiliation":[{"name":"Lanzhou University"},{"name":"Lanzhou University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,2,26]]},"reference":[{"key":"pmbad2714bib1","author":"(ASTM International)","year":"2019","type":"other"},{"key":"pmbad2714bib2","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1088\/0031-9155\/23\/4\/006","type":"journal-article","article-title":"RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging","volume":"23","author":"Bottomley","year":"1978","journal-title":"Phys. Med. Biol."},{"key":"pmbad2714bib3","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1002\/mrm.1910020404","type":"journal-article","article-title":"Estimating radiofrequency power deposition in body NMR imaging","volume":"2","author":"Bottomley","year":"1985","journal-title":"Magn. Reson. Med."},{"key":"pmbad2714bib4","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1118\/1.595000","type":"journal-article","article-title":"Power deposition in whole-body NMR imaging","volume":"8","author":"Bottomley","year":"1981","journal-title":"Med. Phys."},{"key":"pmbad2714bib5","doi-asserted-by":"publisher","first-page":"5287\u2013303","DOI":"10.1088\/0031-9155\/59\/18\/5287","type":"journal-article","article-title":"Development of a new generation of high-resolution anatomical models for medical device evaluation: the virtual population 3.0","volume":"59","author":"Gosselin","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbad2714bib6","author":"Hasgall","year":"2018","type":"other"},{"key":"pmbad2714bib7","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1097\/00004032-200408000-00008","type":"journal-article","article-title":"Medical magnetic resonance (MR) procedures: protection of patients","volume":"87","author":"(International Commission on Non-Ionizing Radiation Protection)","year":"2004","journal-title":"Health Phys."},{"key":"pmbad2714bib8","article-title":"Medical electrical equipment\u2014Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis","author":"(International Electrotechnical Commission)","year":"2010","type":"report"},{"key":"pmbad2714bib9","article-title":"Magnetic resonance equipment for medical imaging part 1: determination of essential image quality parameters","author":"International Electrotechnical Commission","year":"2018","type":"report"},{"key":"pmbad2714bib10","article-title":"Medical electrical equipment\u2014Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis","author":"(International Electrotechnical Commission)","year":"2022","type":"report"},{"key":"pmbad2714bib11","author":"(ISO\/TS)","year":"2022","type":"other"},{"key":"pmbad2714bib12","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1006\/jmre.1996.7488","type":"journal-article","article-title":"Resonant modes of the birdcage coil","volume":"124","author":"Leifer","year":"1997","journal-title":"J. Magn. Reson."},{"key":"pmbad2714bib13","doi-asserted-by":"publisher","first-page":"1135","DOI":"10.1002\/mrm.26703","type":"journal-article","article-title":"A numerical investigation on the effect of RF coil feed variability on global and local electromagnetic field exposure in human body models at 64 MHz","volume":"79","author":"Lucano","year":"2018","journal-title":"Magn. Reson. Med."},{"key":"pmbad2714bib14","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1002\/mrm.24690","type":"journal-article","article-title":"Whole-body and local RF absorption in human models as a function of anatomy and position within 1.5 T MR body coil","volume":"71","author":"Murbach","year":"2014","journal-title":"Magn. Reson. Med."},{"key":"pmbad2714bib15","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.mri.2022.05.004","type":"journal-article","article-title":"Magnetic resonance imaging in patients with cardiac implantable electronic devices: a prospective study","volume":"91","author":"Navarro-Valverde","year":"2022","journal-title":"Magn. Reson. Imaging"},{"key":"pmbad2714bib16","doi-asserted-by":"publisher","first-page":"2555","DOI":"10.1056\/NEJMoa1604267","type":"journal-article","article-title":"Safety of magnetic resonance imaging in patients with cardiac devices","volume":"377","author":"Nazarian","year":"2017","journal-title":"New Engl. J. Med."},{"key":"pmbad2714bib17","doi-asserted-by":"publisher","DOI":"10.1002\/9780470034590.emrstm1230","type":"journal-article","article-title":"Safety considerations in MRI","author":"Norris","year":"2011","journal-title":"eMagRes"},{"key":"pmbad2714bib18","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1109\/TDMR.2005.859033","type":"journal-article","article-title":"MRI and implanted medical devices: basic interactions with an emphasis on heating","volume":"5","author":"Nyenhuis","year":"2005","journal-title":"IEEE Trans. Device Mater. Reliab."},{"key":"pmbad2714bib19","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.ijcard.2021.06.007","type":"journal-article","article-title":"Magnetic resonance imaging in all patients with implanted cardiac devices\u2013Yes, We Can!","volume":"338","author":"Sohns","year":"2021","journal-title":"Int. J. Cardiol."},{"key":"pmbad2714bib20","doi-asserted-by":"publisher","author":"Taflove","year":"2005","DOI":"10.1016\/B978-012170960-0\/50046-3","type":"book"},{"key":"pmbad2714bib21","author":"(U.S. Food and Drug Administration (FDA))","year":"2014","type":"other"},{"key":"pmbad2714bib22","author":"(U.S. Food and Drug Administration (FDA))","year":"2019","type":"other"},{"key":"pmbad2714bib23","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1002\/bem.22206","type":"journal-article","article-title":"Anatomical model uncertainty for RF safety evaluation of metallic implants under MRI exposure","volume":"40","author":"Yao","year":"2019","journal-title":"Bioelectromagnetics"},{"key":"pmbad2714bib24","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac212d","type":"journal-article","article-title":"Induced radiofrequency fields in patients undergoing MR examinations: insights for risk assessment","volume":"66","author":"Yao","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"pmbad2714bib25","first-page":"241","type":"other","article-title":"Piece-wise excitation system for the characterization of local RF-induced heating of AIMD during MR exposure","author":"Zastrow","year":"2014"}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:20:23Z","timestamp":1778775623000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2714"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,26]]},"references-count":25,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2024,2,26]]},"published-print":{"date-parts":[[2024,3,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ad2714","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,26]]},"assertion":[{"value":"Impact of MRI RF coil design on the RF-induced heating of medical implants: fixed\n                      B\n                      1\n                      +\n                      rms\n                      exposure versus normal operating mode","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2023-09-05","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-07","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-26","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}