{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:01:13Z","timestamp":1792785673909,"version":"4.5.0"},"reference-count":36,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T00:00:00Z","timestamp":1708646400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T00:00:00Z","timestamp":1708646400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"IBA"},{"DOI":"10.13039\/501100004489","name":"Mitacs","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004489","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100000046","name":"National Research Council of Canada","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100000046","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2024,3,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . Proton therapy reduces the integral dose to the patient compared to conventional photon treatments. However,\n                    <jats:italic>in vivo<\/jats:italic>\n                    proton range uncertainties remain a considerable hurdle. Range uncertainty reduction benefits depend on clinical practices. During intensity-modulated proton therapy (IMPT), the target is irradiated from only a few directions, but proton arc therapy (PAT), for which the target is irradiated from dozens of angles, may see clinical implementation by the time considerable range uncertainty reductions are achieved. It is therefore crucial to determine the impact of PAT on range uncertainty reduction benefits.\n                    <jats:italic>Approach<\/jats:italic>\n                    . For twenty head-and-neck cancer patients, four different treatment plans were created: an IMPT and a PAT treatment plan assuming current clinical range uncertainties of 3.5% (IMPT\n                    <jats:sub>3.5%<\/jats:sub>\n                    and PAT\n                    <jats:sub>3.5%<\/jats:sub>\n                    ), and an IMPT and a PAT treatment plan assuming that range uncertainties can be reduced to 1% (IMPT\n                    <jats:sub>1%<\/jats:sub>\n                    and PAT\n                    <jats:sub>1%<\/jats:sub>\n                    ). Plans were evaluated with respect to target coverage and organ-at-risk doses as well as normal tissue complication probabilities (NTCPs) for parotid glands (endpoint: parotid gland flow &lt;25%) and larynx (endpoint: larynx edema).\n                    <jats:italic>Main results<\/jats:italic>\n                    . Implementation of PAT (IMPT\n                    <jats:sub>3.5%<\/jats:sub>\n                    \u2212PAT\n                    <jats:sub>3.5%<\/jats:sub>\n                    ) reduced mean NTCPs in the nominal and worst-case scenario by 3.2 percentage points (pp) and 4.2 pp, respectively. Reducing range uncertainties from 3.5% to 1% during use of IMPT (IMPT\n                    <jats:sub>3.5%<\/jats:sub>\n                    \u2212IMPT\n                    <jats:sub>1%<\/jats:sub>\n                    ) reduced evaluated NTCPs by 0.9 pp and 2.0 pp. Benefits of range uncertainty reductions subsequently to PAT implementation (PAT\n                    <jats:sub>3.5%<\/jats:sub>\n                    \u2212PAT\n                    <jats:sub>1%<\/jats:sub>\n                    ) were 0.2 pp and 1.0 pp, with considerably higher benefits in bilateral compared to unilateral cases.\n                    <jats:italic>Significance<\/jats:italic>\n                    . The mean clinical benefit of implementing PAT was more than twice as high as the benefit of a 3.5%\u20131% range uncertainty reduction. Range uncertainty reductions are expected to remain beneficial even after PAT implementation, especially in cases with target positions allowing for full leveraging of the higher number of gantry angles during PAT.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ad2718","type":"journal-article","created":{"date-parts":[[2024,2,7]],"date-time":"2024-02-07T17:23:21Z","timestamp":1707326601000},"page":"055015","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":9,"title":["Impact of and interplay between proton arc therapy and range uncertainties in proton therapy for head-and-neck cancer"],"prefix":"10.1088","volume":"69","author":[{"given":"Sebastian","family":"Tattenberg","sequence":"first","affiliation":[{"name":"Laurentian University"},{"name":"Northern Ontario School of Medicine University"},{"name":"TRIUMF, 4004 Wesbrook Mall, Vancouver V6T 2A3, British Columbia,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peilin","family":"Liu","sequence":"additional","affiliation":[{"name":"William Beaumont University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony","family":"Mulhem","sequence":"additional","affiliation":[{"name":"William Beaumont University Hospital"},{"name":"Michigan State University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoda","family":"Cong","sequence":"additional","affiliation":[{"name":"William Beaumont University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Thome","sequence":"additional","affiliation":[{"name":"Laurentian University"},{"name":"Northern Ontario School of Medicine University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuanfeng","family":"Ding","sequence":"additional","affiliation":[{"name":"William Beaumont University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,2,23]]},"reference":[{"key":"pmbad2718bib1","type":"other"},{"key":"pmbad2718bib2","doi-asserted-by":"publisher","first-page":"2332","DOI":"10.1002\/mp.12215","type":"journal-article","article-title":"The potential of dual-energy CT to reduce proton beam range uncertainties","volume":"44","author":"Baer","year":"2017","journal-title":"Med. Phys."},{"key":"pmbad2718bib3","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/j.ijrobp.2021.06.036","type":"journal-article","article-title":"First-in-human validation of CT-based proton range prediction using prompt gamma imaging in prostate cancer treatments","volume":"111","author":"Berthold","year":"2021","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad2718bib4","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.dib.2017.03.037","type":"journal-article","article-title":"Data for TROTS\u2014the radiotherapy optimisation test set","volume":"12","author":"Breedveld","year":"2017","journal-title":"Data Brief"},{"key":"pmbad2718bib5","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/0360-3016(91)90172-Z","type":"journal-article","article-title":"Fitting of normal tissue tolerance data to an analytic function","volume":"21","author":"Burman","year":"1991","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad2718bib6","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1002\/mp.16098","type":"journal-article","article-title":"Spot scanning proton arc therapy reduces toxicity in oropharyngeal cancer patients","volume":"50","author":"de Jong","year":"2023a","journal-title":"Med. Phys."},{"key":"pmbad2718bib7","doi-asserted-by":"publisher","first-page":"109670","DOI":"10.1016\/j.radonc.2023.109670","type":"journal-article","article-title":"Proton arc therapy increases the benefit of proton therapy for oropharyngeal cancer patients in the model based clinic","volume":"184","author":"de Jong","year":"2023b","journal-title":"Radiother. Oncol."},{"key":"pmbad2718bib8","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1016\/j.ijrobp.2009.07.1708","type":"journal-article","article-title":"Parotid gland function after radiotherapy: the combined michigan and utrecht experience","volume":"78","author":"Dijkema","year":"2010","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad2718bib9","doi-asserted-by":"publisher","first-page":"1107","DOI":"10.1016\/j.ijrobp.2016.08.049","type":"journal-article","article-title":"Spot-scanning proton arc (SPArc) therapy: the first robust and delivery-efficient spot-scanning proton arc therapy","volume":"96","author":"Ding","year":"2016","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad2718bib10","doi-asserted-by":"publisher","first-page":"4100","DOI":"10.1038\/s41598-018-22325-6","type":"journal-article","article-title":"Online proton therapy moni- toring: clinical test of a silicon-photodetector-based in-beam PET","volume":"8","author":"Ferrero","year":"2018","journal-title":"Sci Rep."},{"key":"pmbad2718bib11","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1002\/roi.2970030107","type":"journal-article","article-title":"Acoustic pulse generated in a patient during treatment by pulsed proton radiation beam","volume":"3","author":"Hayakawa","year":"1995","journal-title":"Radiat. Oncol. Invest."},{"key":"pmbad2718bib12","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aad513","type":"journal-article","article-title":"A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy","volume":"63","author":"Hueso-Gonzalez","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbad2718bib13","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.radonc.2019.04.032","type":"journal-article","article-title":"The first prototype of spot-scanning proton arc treatment delivery","volume":"137","author":"Li","year":"2019","journal-title":"Radiother. Oncol."},{"key":"pmbad2718bib14","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2021.698537","type":"journal-article","article-title":"Linear energy transfer incorporated spot-scanning proton arc therapy optimization: a feasibility study","volume":"11","author":"Li","year":"2021","journal-title":"Front. Oncol."},{"key":"pmbad2718bib15","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-020-01676-3.","type":"journal-article","article-title":"Feasibility study: spot-scanning proton arc therapy (SPArc) for left-sided whole breast radiotherapy","volume":"15","author":"Liu","year":"2020a","journal-title":"Radiat. Oncol."},{"key":"pmbad2718bib16","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-020-1476-9","type":"journal-article","article-title":"Improve the dosimetric outcome in bilateral head and neck cancer (HNC) treatment using spot-scanning proton arc (SPArc) therapy: a feasibility study","volume":"15","author":"Liu","year":"2020b","journal-title":"Radiat. Oncol."},{"key":"pmbad2718bib17","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acfec5","type":"journal-article","article-title":"The first investigation of spot-scanning proton arc (SPArc) delivery time and accuracy with different delivery tolerance window settings","volume":"68","author":"Liu","year":"2023b","journal-title":"Phys. Med. Biol."},{"key":"pmbad2718bib18","doi-asserted-by":"publisher","DOI":"10.1002\/mp.16879","type":"journal-article","article-title":"Development of a standalone delivery sequence model for proton arc therapy","author":"Liu","year":"2023a","journal-title":"Med. Phys."},{"key":"pmbad2718bib19","doi-asserted-by":"publisher","DOI":"10.1063\/1.2378561","type":"journal-article","article-title":"Prompt gamma measurements for locating the dose falloff region in the proton therapy","volume":"89","author":"Min","year":"2006","journal-title":"Appl. Phys. Lett."},{"key":"pmbad2718bib20","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.oraloncology.2018.11.015.","type":"journal-article","article-title":"Intensity modulated proton therapy (IMPT)\u2014the future of IMRT for Head and neck cancer","volume":"88","author":"Moreno","year":"2020","journal-title":"Oral. Oncol."},{"key":"pmbad2718bib21","doi-asserted-by":"publisher","first-page":"R99","DOI":"10.1088\/0031-9155\/57\/11\/R99","type":"journal-article","article-title":"Range uncertainties in proton therapy and the role of Monte Carlo simulations","volume":"57","author":"Paganetti","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbad2718bib22","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1016\/j.ijrobp.2007.01.063","type":"journal-article","article-title":"Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton ther- apy","volume":"68","author":"Parodi","year":"2007","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad2718bib23","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.zemedi.2022.11.001","type":"journal-article","article-title":"Experience and new prospects of pet imaging for ion beam therapy monitoring","volume":"33","author":"Parodi","year":"2023","journal-title":"Z. Med. Phys."},{"key":"pmbad2718bib24","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.radonc.2021.11.002","type":"journal-article","article-title":"Reduction of clinical safety margins in proton therapy enabled by the clinical implementation of dual-energy CT for direct stopping-power prediction","volume":"166","author":"Peters","year":"2022","journal-title":"Radiother. Oncol."},{"key":"pmbad2718bib25","doi-asserted-by":"publisher","first-page":"S64","DOI":"10.1016\/j.ijrobp.2009.03.079","type":"journal-article","article-title":"Radiation dose-volume effects in the larynx and pharynx","volume":"76","author":"Rancati","year":"2010","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad2718bib26","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1016\/j.radonc.2016.01.004","type":"journal-article","article-title":"First clinical application of a prompt gamma based in vivo proton range verification system","volume":"118","author":"Richter","year":"2016","journal-title":"Radiother. Oncol."},{"key":"pmbad2718bib27","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1016\/S0360-3016(97)00059-X","type":"journal-article","article-title":"Phantom assessment of lung dose from proton arc therapy","volume":"38","author":"Sandison","year":"1997","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad2718bib28","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.925542","type":"journal-article","article-title":"Proton beam range verification by means of ionoacoustic measurements at clinically relevant doses using a correlation-based evaluation","volume":"12","author":"Schauer","year":"2022","journal-title":"Front. Oncol."},{"key":"pmbad2718bib29","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1118\/1.596618","type":"journal-article","article-title":"Time resolved properties of acoustic pulses generated in water and in soft tissue by pulsed proton beam irradiation\u2014a possibility of doses distribution monitoring in proton radiation therapy","volume":"18","author":"Tada","year":"1991","journal-title":"Med. Phys."},{"key":"pmbad2718bib30","doi-asserted-by":"publisher","first-page":"4693","DOI":"10.1002\/mp.15644","type":"journal-article","article-title":"Range uncertainty reductions in proton therapy may lead to the feasibility of novel beam arrangements which improve organ-at-risk sparing","volume":"49","author":"Tattenberg","year":"2022","journal-title":"Med. Phys."},{"key":"pmbad2718bib31","doi-asserted-by":"publisher","first-page":"5356","DOI":"10.1002\/mp.15097","type":"journal-article","article-title":"Proton range uncertainty reduction benefits for skull base tumors in terms of normal tissue complication probability (NTCP) and healthy tissue doses","volume":"48","author":"Tattenberg","year":"2021","journal-title":"Med. Phys."},{"key":"pmbad2718bib32","doi-asserted-by":"publisher","first-page":"7089","DOI":"10.1088\/0031-9155\/59\/23\/7089","type":"journal-article","article-title":"Proton range verification through prompt gamma-ray spectroscopy","volume":"59","author":"Verburg","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbad2718bib33","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.radonc.2020.09.001","type":"journal-article","article-title":"Head and neck IMPT probabilistic dose accumulation: feasibility of a 2 mm setup uncertainty setting","volume":"154","author":"Wagenaar","year":"2021","journal-title":"Radiother. Oncol."},{"key":"pmbad2718bib34","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.radonc.2016.04.038","type":"journal-article","article-title":"The price of robustness; impact of worst-case optimization on organ-at-risk dose and complication probability in intensity-modulated proton therapy for oropharyngeal cancer patients","volume":"120","author":"van de Water","year":"2016","journal-title":"Radiother. Oncol."},{"key":"pmbad2718bib35","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1148\/47.5.487","type":"journal-article","article-title":"Radiological use of fast protons","volume":"47","author":"Wilson","year":"1946","journal-title":"Radiology"},{"key":"pmbad2718bib36","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/j.ijrobp.2017.04.027","type":"journal-article","article-title":"Prompt gamma imaging for in vivo range verification of pencil beam scanning proton therapy","volume":"99","author":"Xie","year":"2017","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:59:11Z","timestamp":1778777951000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad2718"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,23]]},"references-count":36,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2024,2,23]]},"published-print":{"date-parts":[[2024,3,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ad2718","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,23]]},"assertion":[{"value":"Impact of and interplay between proton arc therapy and range uncertainties in proton therapy for head-and-neck cancer","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-09-01","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-07","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-23","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}