{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T17:23:09Z","timestamp":1794936189997,"version":"4.9.1"},"reference-count":43,"publisher":"IOP Publishing","issue":"8","license":[{"start":{"date-parts":[[2024,4,3]],"date-time":"2024-04-03T00:00:00Z","timestamp":1712102400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,4,3]],"date-time":"2024-04-03T00:00:00Z","timestamp":1712102400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"crossref","award":["APP1102198"],"award-info":[{"award-number":["APP1102198"]}],"id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2024,4,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objectives.<\/jats:italic>\n                    Contouring similarity metrics are often used in studies of inter-observer variation and automatic segmentation but do not provide an assessment of clinical impact. This study focused on post-prostatectomy radiotherapy and aimed to (1) identify if there is a relationship between variations in commonly used contouring similarity metrics and resulting dosimetry and (2) identify the variation in clinical target volume (CTV) contouring that significantly impacts dosimetry.\n                    <jats:italic>Approach.<\/jats:italic>\n                    The study retrospectively analysed CT scans of 10 patients from the TROG 08.03 RAVES trial. The CTV, rectum, and bladder were contoured independently by three experienced observers. Using these contours reference simultaneous truth and performance level estimation (STAPLE) volumes were established. Additional CTVs were generated using an atlas algorithm based on a single benchmark case with 42 manual contours. Volumetric-modulated arc therapy (VMAT) treatment plans were generated for the observer, atlas, and reference volumes. The dosimetry was evaluated using radiobiological metrics. Correlations between contouring similarity and dosimetry metrics were calculated using Spearman coefficient (\u0393). To access impact of variations in planning target volume (PTV) margin, the STAPLE PTV was uniformly contracted and expanded, with plans created for each PTV volume. STAPLE dose-volume histograms (DVHs) were exported for plans generated based on the contracted\/expanded volumes, and dose-volume metrics assessed.\n                    <jats:italic>Main<\/jats:italic>\n                    <jats:italic>results<\/jats:italic>\n                    . The study found no strong correlations between the considered similarity metrics and modelled outcomes. Moderate correlations (0.5 &lt;\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>|<\/mml:mo>\n                          <mml:mo>|<\/mml:mo>\n                          <mml:mfenced close=\"\" open=\"\">\n                            <mml:mrow>\n                              <mml:mi mathvariant=\"normal\">\u0393<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:mfenced>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    &lt; 0.7) were observed for Dice similarity coefficient, Jaccard, and mean distance to agreement metrics and rectum toxicities. The observations of this study indicate a tendency for variations in CTV contraction\/expansion below 5 mm to result in minor dosimetric impacts.\n                    <jats:italic>Significance<\/jats:italic>\n                    . Contouring similarity metrics must be used with caution when interpreting them as indicators of treatment plan variation. For post-prostatectomy VMAT patients, this work showed variations in contours with an expansion\/contraction of less than 5 mm did not lead to notable dosimetric differences, this should be explored in a larger dataset to assess generalisability.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ad3325","type":"journal-article","created":{"date-parts":[[2024,3,12]],"date-time":"2024-03-12T18:42:00Z","timestamp":1710268920000},"page":"085008","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Evaluating the relationship between contouring variability and modelled treatment outcome for prostate bed radiotherapy"],"prefix":"10.1088","volume":"69","author":[{"given":"Viet","family":"Le Bao","sequence":"first","affiliation":[{"name":"University of New South Wales"},{"name":"Ingham Institute for Applied Medical Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annette","family":"Haworth","sequence":"additional","affiliation":[{"name":"Institute of Medical Physics"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9349-2275","authenticated-orcid":true,"given":"Jason","family":"Dowling","sequence":"additional","affiliation":[{"name":"University of New South Wales"},{"name":"Ingham Institute for Applied Medical Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amy","family":"Walker","sequence":"additional","affiliation":[{"name":"University of New South Wales"},{"name":"Ingham Institute for Applied Medical Research"},{"name":"Liverpool and Macarthur Cancer Therapy Centres, Sydney,"},{"name":"University of Wollongong"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sankar","family":"Arumugam","sequence":"additional","affiliation":[{"name":"University of New South Wales"},{"name":"Ingham Institute for Applied Medical Research"},{"name":"Liverpool and Macarthur Cancer Therapy Centres, Sydney,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Jameson","sequence":"additional","affiliation":[{"name":"University of New South Wales"},{"name":"GenesisCare, Sydney, NSW,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillip","family":"Chlap","sequence":"additional","affiliation":[{"name":"University of New South Wales"},{"name":"Ingham Institute for Applied Medical Research"},{"name":"Liverpool and Macarthur Cancer Therapy Centres, Sydney,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kirsty","family":"Wiltshire","sequence":"additional","affiliation":[{"name":"Peter MacCallum Cancer Centre"},{"name":"The University of Melbourne"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Keats","sequence":"additional","affiliation":[{"name":"Ingham Institute for Applied Medical Research"},{"name":"Liverpool and Macarthur Cancer Therapy Centres, Sydney,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kirrily","family":"Cloak","sequence":"additional","affiliation":[{"name":"University of New South Wales"},{"name":"Ingham Institute for Applied Medical Research"},{"name":"Liverpool and Macarthur Cancer Therapy Centres, Sydney,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Sidhom","sequence":"additional","affiliation":[{"name":"University of New South Wales"},{"name":"Liverpool and Macarthur Cancer Therapy Centres, Sydney,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Kneebone","sequence":"additional","affiliation":[{"name":"Royal North Shore Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4337-2165","authenticated-orcid":true,"given":"Lois","family":"Holloway","sequence":"additional","affiliation":[{"name":"University of New South Wales"},{"name":"Ingham Institute for Applied Medical Research"},{"name":"Institute of Medical Physics"},{"name":"Liverpool and Macarthur Cancer Therapy Centres, Sydney,"},{"name":"University of Wollongong"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,4,3]]},"reference":[{"key":"pmbad3325bib1","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.semradonc.2019.02.001","type":"journal-article","article-title":"Advances in auto-segmentation","volume":"29","author":"Cardenas","year":"2019","journal-title":"Semin. Radiat. Oncol."},{"key":"pmbad3325bib2","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1111\/1754-9485.12884","type":"journal-article","article-title":"Contour variation is a primary source of error when delivering post prostatectomy radiotherapy: results of the trans-tasman radiation oncology group 08.03 radiotherapy adjuvant versus early salvage (RAVES) benchmarking exercise","volume":"63","author":"Cloak","year":"2019a","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"pmbad3325bib3","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1111\/1754-9485.12884","type":"journal-article","article-title":"Contour variation is a primary source of error when delivering post prostatectomy radiotherapy: results of the trans-tasman radiation Oncology group 08.03 radiotherapy adjuvant versus early salvage (RAVES) benchmarking exercise","volume":"63","author":"Cloak","year":"2019b","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"pmbad3325bib4","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.radonc.2016.02.022","type":"journal-article","article-title":"Assessment of fully-automated atlas-based segmentation of novel oral mucosal surface organ-at-risk","volume":"119","author":"Dean","year":"2016","journal-title":"Radiother. Oncol."},{"key":"pmbad3325bib5","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2016.00178","type":"journal-article","article-title":"Comparison of automated atlas-based segmentation software for postoperative prostate cancer radiotherapy","volume":"6","author":"Delpon","year":"2016","journal-title":"Front. Oncol."},{"key":"pmbad3325bib6","doi-asserted-by":"publisher","first-page":"012048","DOI":"10.1088\/1742-6596\/489\/1\/012048","type":"journal-article","article-title":"Automatic atlas based electron density and structure contouring for mri-based prostate radiation therapy on the cloud","volume":"489","author":"Dowling","year":"2014","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmbad3325bib7","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1016\/j.ijrobp.2015.08.045","type":"journal-article","article-title":"Automatic substitute computed tomography generation and contouring for magnetic resonance imaging (MRI)-alone External beam radiation therapy from standard MRI sequences","volume":"93","author":"Dowling","year":"2015","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad3325bib8","doi-asserted-by":"publisher","DOI":"10.3127\/ajis.v22i0.1538","type":"journal-article","article-title":"Comparing sets of patterns with the Jaccard index","volume":"22","author":"Fletcher","year":"2018","journal-title":"Austr. J. Inf. Syst."},{"key":"pmbad3325bib9","doi-asserted-by":"publisher","first-page":"1676","DOI":"10.3109\/0284186X.2012.754989","type":"journal-article","article-title":"Clinical validation of atlas-based auto-segmentation of pelvic volumes and normal tissue in rectal tumors using auto-segmentation computed system","volume":"52","author":"Gambacorta","year":"2013","journal-title":"Acta Oncol."},{"key":"pmbad3325bib10","author":"Hinkle","year":"2003","type":"book"},{"key":"pmbad3325bib11","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.meddos.2011.11.004","type":"journal-article","article-title":"Comp plan: a computer program to generate dose and radiobiological metrics from dose\u2013volume histogram files","volume":"37","author":"Holloway","year":"2012","journal-title":"Med. Dosim."},{"key":"pmbad3325bib12","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1186\/1748-717X-6-110","type":"journal-article","article-title":"Technology assessment of automated atlas based segmentation in prostate bed contouring","volume":"6","author":"Hwee","year":"2011","journal-title":"Radiat. Oncol."},{"key":"pmbad3325bib13","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.radonc.2014.03.019","type":"journal-article","article-title":"Correlation of contouring variation with modeled outcome for conformal non-small cell lung cancer radiotherapy","volume":"112","author":"Jameson","year":"2014","journal-title":"Radiother. Oncol."},{"key":"pmbad3325bib14","doi-asserted-by":"crossref","first-page":"S891","DOI":"10.1016\/S0167-8140(16)33137-1","type":"journal-article","article-title":"The feasibility of atlas-based automatic segmentation of MRI for H&N radiotherapy planning","volume":"119","author":"Kardman","year":"2016","journal-title":"Radiother. Oncol."},{"key":"pmbad3325bib15","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1016\/j.ijrobp.2007.10.008","type":"journal-article","article-title":"Radiotherapy after prostatectomy: is the evidence for dose escalation out there?","volume":"71","author":"King","year":"2008","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad3325bib16","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1016\/S1470-2045(20)30456-3","type":"journal-article","article-title":"Adjuvant radiotherapy versus early salvage radiotherapy following radical prostatectomy (TROG 08.03\/ANZUP RAVES): a randomised, controlled, phase 3, non-inferiority trial","volume":"21","author":"Kneebone","year":"2020","journal-title":"Lancet Oncol."},{"key":"pmbad3325bib17","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1016\/0360-3016(89)90972-3","type":"journal-article","article-title":"Calculation of complication probability factors for non-uniform normal tissue irradiation: the effective volume method","volume":"16","author":"Kutcher","year":"1989","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad3325bib18","doi-asserted-by":"crossref","first-page":"108","DOI":"10.3389\/fonc.2017.00108","type":"journal-article","article-title":"Delineation of the prostate bed: the \u2018Invisible Target\u2019 is still an issue?","volume":"31","author":"Latorzeff","year":"2017","journal-title":"Front. Oncol."},{"key":"pmbad3325bib19","article-title":"Modelling Uncertainties in Radiation Therapy: The Clinical Impact on Prostate Bed Treatment","author":"Le","year":"2023","type":"other"},{"key":"pmbad3325bib20","doi-asserted-by":"publisher","first-page":"11","DOI":"10.3857\/roj.2017.00080","type":"journal-article","article-title":"Interobserver variation in target volume for salvage radiotherapy in recurrent prostate cancer patients after radical prostatectomy using CT versus combined CT and MRI: a multicenter study (KROG 13-11)","volume":"36","author":"Lee","year":"2018","journal-title":"Radiat. Oncol. J."},{"key":"pmbad3325bib21","author":"Leslie","year":"2023","type":"book"},{"key":"pmbad3325bib22","doi-asserted-by":"publisher","first-page":"47","DOI":"10.4236\/ijmpcero.2021.102005","type":"journal-article","article-title":"Dosimetric effects due to inter-observer variability of organ contouring when utilizing a knowledge-based planning system for prostate cancer","volume":"10","author":"Liu","year":"2021","journal-title":"Int. J. Med. Phys., Clin. Eng. Radiat. Oncol."},{"key":"pmbad3325bib23","doi-asserted-by":"publisher","first-page":"1040","DOI":"10.3109\/0284186X.2010.509736","type":"journal-article","article-title":"Normal tissue complication probability (NTCP) modeling of late rectal bleeding following external beam radiotherapy for prostate cancer: a test of the QUANTEC-recommended NTCP model","volume":"49","author":"Liu","year":"2010","journal-title":"Acta Oncol."},{"key":"pmbad3325bib24","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1016\/j.ijrobp.2004.05.005","type":"journal-article","article-title":"Do differences in target volume definition in prostate cancer lead to clinically relevant differences in normal tissue toxicity?","volume":"60","author":"Livsey","year":"2004","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad3325bib25","doi-asserted-by":"crossref","DOI":"10.3389\/fninf.2013.00045","type":"journal-article","article-title":"The design of SimpleITK","volume":"7","author":"Lowekamp","year":"2013","journal-title":"Front. Neuroinform."},{"key":"pmbad3325bib26","doi-asserted-by":"publisher","first-page":"S13","DOI":"10.2307\/3583506","type":"journal-article","article-title":"Complication probability as assessed from dose\u2013volume histograms","volume":"8","author":"Lyman","year":"1985","journal-title":"Radiat. Res. Suppl."},{"key":"pmbad3325bib27","author":"Machin","year":"2011","type":"book"},{"key":"pmbad3325bib28","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s13014-018-0961-x","type":"journal-article","article-title":"Fitting NTCP models to bladder doses and acute urinary symptoms during post-prostatectomy radiotherapy","volume":"13","author":"Mavroidis","year":"2018","journal-title":"Radiat. Oncol."},{"key":"pmbad3325bib29","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.ijrobp.2009.03.078","type":"journal-article","article-title":"Radiation dose\u2013volume effects in radiation-induced rectal injury","volume":"76","author":"Michalski","year":"2010a","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad3325bib30","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.ijrobp.2009.02.006","type":"journal-article","article-title":"Development of RTOG consensus guidelines for the definition of the clinical target volume for postoperative conformal radiation therapy for prostate cancer","volume":"76","author":"Michalski","year":"2010b","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad3325bib31","type":"journal-article","article-title":"Use and misuse of corrections for multiple testing","volume":"8","author":"Miguel","year":"2023","journal-title":"Methods Psychol."},{"key":"pmbad3325bib32","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1016\/j.ijrobp.2008.12.042","type":"journal-article","article-title":"Assessing the effect of a contouring protocol on postprostatectomy radiotherapy clinical target volumes and interphysician variation","volume":"75","author":"Mitchell","year":"2009","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad3325bib33","type":"journal-article","article-title":"Automation in intensity modulated radiotherapy treatment planning\u2014a review of recent innovations","volume":"91","author":"Mohammad","year":"2018","journal-title":"Br. J. Radiol."},{"key":"pmbad3325bib34","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.ijrobp.2010.12.057","type":"journal-article","article-title":"Delineation of the postprostatectomy prostate bed using computed tomography: interobserver variability following the EORTC delineation guidelines","volume":"81","author":"Ost","year":"2011","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad3325bib35","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1111\/bju.12623","type":"journal-article","article-title":"A phase III trial to investigate the timing of radiotherapy for prostate cancer with high-risk features: background and rationale of the radiotherapy\u2014adjuvant versus early salvage (RAVES) trial","volume":"113","author":"Pearse","year":"2014","journal-title":"BJU Int."},{"key":"pmbad3325bib36","doi-asserted-by":"publisher","first-page":"035001","DOI":"10.1088\/1361-6560\/aaa50c","type":"journal-article","article-title":"Correlations between contouring similarity metrics and simulated treatment outcome for prostate radiotherapy","volume":"63","author":"Roach","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbad3325bib37","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.radonc.2008.05.006","type":"journal-article","article-title":"Post-prostatectomy radiation therapy: consensus guidelines of the Australian and New Zealand radiation oncology genito-urinary group","volume":"88","author":"Sidhom","year":"2008","journal-title":"Radiother. Oncol."},{"key":"pmbad3325bib38","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.radonc.2014.09.014","type":"journal-article","article-title":"Recommendations on how to establish evidence from auto-segmentation software in radiotherapy","volume":"112","author":"Valentini","year":"2014","journal-title":"Radiother. Oncol."},{"key":"pmbad3325bib39","doi-asserted-by":"crossref","first-page":"S61","DOI":"10.1016\/j.neuroimage.2008.10.040","type":"journal-article","article-title":"Diffeomorphic demons: efficient non-parametric image registration","volume":"45","author":"Vercauteren","year":"2009","journal-title":"NeuroImage"},{"key":"pmbad3325bib40","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.radonc.2016.09.009","type":"journal-article","article-title":"Uncertainties in volume delineation in radiation oncology: A systematic review and recommendations for future studies","volume":"121","author":"Vinod","year":"2016","journal-title":"Radiat. Oncol."},{"key":"pmbad3325bib41","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1109\/TMI.2004.828354","type":"journal-article","article-title":"Simultaneous truth and performance level estimation (STAPLE): an algorithm for the validation of image segmentation","volume":"23","author":"Warfield","year":"2004","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbad3325bib42","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/s00066-003-0976-5","type":"journal-article","article-title":"The impact of gross tumor volume (GTV) and clinical target volume (CTV) definition on the total accuracy in radiotherapy","volume":"179","author":"Weiss","year":"2003","journal-title":"Strahlenther. Onkol."},{"key":"pmbad3325bib43","type":"journal-article","article-title":"Advances in high-risk localized prostate cancer: Staging and management","volume":"47","author":"Yeison","year":"2023","journal-title":"Curr. Probl. Cancer"}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:16:46Z","timestamp":1778775406000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad3325"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,3]]},"references-count":43,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2024,4,3]]},"published-print":{"date-parts":[[2024,4,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ad3325","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,3]]},"assertion":[{"value":"Evaluating the relationship between contouring variability and modelled treatment outcome for prostate bed radiotherapy","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2023-10-19","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-03-12","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-04-03","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}