{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T22:04:21Z","timestamp":1791583461346,"version":"4.3.4"},"reference-count":40,"publisher":"IOP Publishing","issue":"11","license":[{"start":{"date-parts":[[2024,5,30]],"date-time":"2024-05-30T00:00:00Z","timestamp":1717027200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,5,30]],"date-time":"2024-05-30T00:00:00Z","timestamp":1717027200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Shanghai Key Laboratory of Proton-therapy"},{"name":"Hubei Key Laboratory of Precision Radiation Oncology","award":["No. jzfs005"],"award-info":[{"award-number":["No. jzfs005"]}]},{"name":"Research and Development Program of China","award":["2016YFC0105311"],"award-info":[{"award-number":["2016YFC0105311"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2024,6,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> To evaluate the feasibility of using a deep learning dose prediction approach to identify patients who could benefit most from proton therapy based on the normal tissue complication probability (NTCP) model. <jats:italic>Approach.<\/jats:italic> Two 3D UNets were established to predict photon and proton doses. A dataset of 95 patients with localized prostate cancer was randomly partitioned into 55, 10, and 30 for training, validation, and testing, respectively. We selected NTCP models for late rectum bleeding and acute urinary urgency of grade 2 or higher to quantify the benefit of proton therapy. Propagated uncertainties of predicted \u0394NTCPs resulting from the dose prediction errors were calculated. Patient selection accuracies for a single endpoint and a composite evaluation were assessed under different \u0394NTCP thresholds. <jats:italic>Main results.<\/jats:italic> Our deep learning-based dose prediction technique can reduce the time spent on plan comparison from approximately 2 days to as little as 5 seconds. The expanded uncertainty of predicted \u0394NTCPs for rectum and bladder endpoints propagated from the dose prediction error were 0.0042 and 0.0016, respectively, which is less than one-third of the acceptable tolerance. The averaged selection accuracies for rectum bleeding, urinary urgency, and composite evaluation were 90%, 93.5%, and 93.5%, respectively. <jats:italic>Significance.<\/jats:italic> Our study demonstrates that deep learning dose prediction and NTCP evaluation scheme could distinguish the NTCP differences between photon and proton treatment modalities. In addition, the dose prediction uncertainty does not significantly influence the decision accuracy of NTCP-based patient selection for proton therapy. Therefore, automated deep learning dose prediction and NTCP evaluation schemes can potentially be used to screen large patient populations and to avoid unnecessary delays in the start of prostate cancer radiotherapy in the future.<\/jats:p>","DOI":"10.1088\/1361-6560\/ad48f6","type":"journal-article","created":{"date-parts":[[2024,5,8]],"date-time":"2024-05-08T18:45:12Z","timestamp":1715193912000},"page":"115056","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Evaluation of an automated clinical decision system with deep learning dose prediction and NTCP model for prostate cancer proton therapy"],"prefix":"10.1088","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8108-9622","authenticated-orcid":true,"given":"Mei","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Pang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yiling","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiayi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kunyu","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2806-1214","authenticated-orcid":true,"given":"Zhiyong","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,5,30]]},"reference":[{"key":"pmbad48f6bib1","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1118\/1.3685447","article-title":"The use and QA of biologically related models for treatment planning: short report of the TG-166 of the therapy physics committee of the AAPM","volume":"39","author":"Allen Li","year":"2012","journal-title":"Med. Phys."},{"key":"pmbad48f6bib2","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1017\/S1460396908006316","article-title":"Variations in inter-observer contouring and its impact on dosimetric and radiobiological parameters for intensity-modulated radiotherapy planning in treatment of localised prostate cancer","volume":"7","author":"Bhardwaj","year":"2008","journal-title":"J. Radiother. Pract."},{"key":"pmbad48f6bib3","doi-asserted-by":"publisher","first-page":"1444","DOI":"10.1080\/0284186X.2017.1355113","article-title":"Impact of model and dose uncertainty on model-based selection of oropharyngeal cancer patients for proton therapy","volume":"56","author":"Bijman","year":"2017","journal-title":"Acta Oncol."},{"key":"pmbad48f6bib4","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/0360-3016(91)90172-Z","article-title":"Fitting of normal tissue tolerance data to an analytic-function","volume":"21","author":"Burman","year":"1991","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad48f6bib5","doi-asserted-by":"publisher","first-page":"9178","DOI":"10.1038\/s41598-022-12898-8","article-title":"Predictive performance of different NTCP techniques for radiation-induced esophagitis in NSCLC patients receiving proton radiotherapy","volume":"12","author":"Chen","year":"2022","journal-title":"Sci. Rep."},{"key":"pmbad48f6bib6","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1002\/mp.13262","article-title":"A feasibility study on an automated method to generate patient-specific dose distributions for radiotherapy using deep learning","volume":"46","author":"Chen","year":"2019","journal-title":"Med. Phys."},{"key":"pmbad48f6bib7","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1016\/j.ijrobp.2004.07.723","article-title":"Dose-response characteristics of low- and intermediate-risk prostate cancer treated with external beam radiotherapy","volume":"61","author":"Cheung","year":"2005","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad48f6bib8","first-page":"424","author":"\u00c7i\u00e7ek","year":"2016"},{"key":"pmbad48f6bib9","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.radonc.2022.08.031","article-title":"Automated clinical decision support system with deep learning dose prediction and NTCP models to evaluate treatment complications in patients with esophageal cancer","volume":"176","author":"Draguet","year":"2022","journal-title":"Radiother. Oncol."},{"key":"pmbad48f6bib10","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1002\/mp.13271","article-title":"Automatic treatment planning based on three-dimensional dose distribution predicted from deep learning technique","volume":"46","author":"Fan","year":"2019","journal-title":"Med. Phys."},{"key":"pmbad48f6bib11","doi-asserted-by":"publisher","DOI":"10.3389\/fdata.2022.1080715","article-title":"3D bi-directional transformer U-Net for medical image segmentation","volume":"5","author":"Fu","year":"2023","journal-title":"Front. Big Data"},{"key":"pmbad48f6bib12","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.radonc.2020.11.026","article-title":"Deep learning prediction of proton and photon dose distributions for paediatric abdominal tumours","volume":"156","author":"Guerreiro","year":"2021","journal-title":"Radiother. Oncol."},{"key":"pmbad48f6bib13","first-page":"49","author":"Humbert-Vidan"},{"key":"pmbad48f6bib14","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2022.100903","article-title":"Fast, automated, knowledge-based treatment planning for selecting patients for proton therapy based on normal tissue complication probabilities","volume":"7","author":"Hyt\u00f6nen","year":"2022","journal-title":"Adv. Radiat. Oncol."},{"key":"pmbad48f6bib15","author":"ISO\/IEC 17025:2017","year":"2017"},{"key":"pmbad48f6bib16","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaef74","article-title":"DoseNet: a volumetric dose prediction algorithm using 3D fully-convolutional neural networks","volume":"63","author":"Kearney","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbad48f6bib17","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.ijrobp.2018.08.023","article-title":"Automated robust proton planning using dose-volume histogram-based mimicking of the photon reference dose and reducing organ at risk dose optimization","volume":"103","author":"Kierkels","year":"2019","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad48f6bib18","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.radonc.2021.02.034","article-title":"Model based patient pre-selection for intensity-modulated proton therapy (IMPT) using automated treatment planning and machine learning","volume":"158","author":"Kouwenberg","year":"2021","journal-title":"Radiother. Oncol."},{"key":"pmbad48f6bib19","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1016\/0360-3016(89)90972-3","article-title":"Calculation of complication probability factors for non-uniform normal tissue irradiation\u2014the effective volume method","volume":"16","author":"Kutcher","year":"1989","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad48f6bib20","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/0360-3016(91)90173-2","article-title":"Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations","volume":"21","author":"Kutcher","year":"1991","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad48f6bib21","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.semradonc.2017.11.008","article-title":"Clinical trial strategies to compare protons with photons","volume":"28","author":"Langendijk","year":"2018","journal-title":"Semin. Radiat. Oncol."},{"key":"pmbad48f6bib22","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.radonc.2013.05.007","article-title":"Selection of patients for radiotherapy with protons aiming at reduction of side effects: the model-based approach","volume":"107","author":"Langendijk","year":"2013","journal-title":"Radiother. Oncol."},{"key":"pmbad48f6bib23","doi-asserted-by":"publisher","first-page":"S13","DOI":"10.2307\/3576626","article-title":"Complication probability as assessed from dose-volume histograms","volume":"104","author":"Lyman","year":"1985","journal-title":"Radiat. Res. Suppl."},{"key":"pmbad48f6bib24","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1002\/mp.15461","article-title":"Site-agnostic 3D dose distribution prediction with deep learning neural networks","volume":"49","author":"Mashayekhi","year":"2022","journal-title":"Med. Phys."},{"key":"pmbad48f6bib25","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/s13014-018-0961-x","article-title":"Fitting NTCP models to bladder doses and acute urinary symptoms during post-prostatectomy radiotherapy","volume":"13","author":"Mavroidis","year":"2018","journal-title":"Radiat. Oncol."},{"key":"pmbad48f6bib26","doi-asserted-by":"publisher","first-page":"7791","DOI":"10.1002\/mp.16066","article-title":"Small beams, fast predictions: a comparison of machine learning dose prediction models for proton minibeam therapy","volume":"49","author":"Mentzel","year":"2022","journal-title":"Med. Phys."},{"key":"pmbad48f6bib27","doi-asserted-by":"publisher","first-page":"S123","DOI":"10.1016\/j.ijrobp.2009.03.078","article-title":"Radiation dose-volume effects in radiation-induced rectal injury","volume":"76","author":"Michalski","year":"2010","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad48f6bib28","doi-asserted-by":"publisher","first-page":"1879","DOI":"10.1002\/mp.16235","article-title":"Impact of delineation errors on the estimated organ at risk dose and of dose errors on the normal tissue complication probability model","volume":"50","author":"M\u00f6vik","year":"2023","journal-title":"Med. Phys."},{"key":"pmbad48f6bib29","doi-asserted-by":"publisher","first-page":"1893","DOI":"10.1002\/mp.14658","article-title":"Long short-term memory networks for proton dose calculation in highly heterogeneous tissues","volume":"48","author":"Neishabouri","year":"2021","journal-title":"Med. Phys."},{"key":"pmbad48f6bib30","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1118\/1.598063","article-title":"Reporting and analyzing dose distributions: a concept of equivalent uniform dose","volume":"24","author":"Niemierko","year":"1997","journal-title":"Med. Phys."},{"key":"pmbad48f6bib31","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aba164","article-title":"Fast spot-scanning proton dose calculation method with uncertainty quantification using a three-dimensional convolutional neural network","volume":"65","author":"Nomura","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbad48f6bib32","doi-asserted-by":"publisher","first-page":"4980","DOI":"10.1002\/mp.15812","article-title":"Technical note: optimal allocation of limited proton therapy resources using model-based patient selection","volume":"49","author":"Papp","year":"2022","journal-title":"Med. Phys."},{"key":"pmbad48f6bib33","author":"Particle Therapy Co-Operative Group","year":"2022"},{"key":"pmbad48f6bib34","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.radonc.2009.12.002","article-title":"How costly is particle therapy? Cost analysis of external beam radiotherapy with carbon-ions, protons and photons","volume":"95","author":"Peeters","year":"2010","journal-title":"Radiother. Oncol."},{"key":"pmbad48f6bib35","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2021.644767","article-title":"Inter-observer variation in delineating the pharyngeal constrictor muscle as organ at risk in radiotherapy for head and neck cancer","volume":"11","author":"Petkar","year":"2021","journal-title":"Front. Oncol."},{"key":"pmbad48f6bib36","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.3109\/0284186X.2014.1001034","article-title":"Variation of normal tissue complication probability (NTCP) estimates of radiation-induced hypothyroidism in relation to changes in delineation of the thyroid gland","volume":"54","author":"R\u00f8njom","year":"2015","journal-title":"Acta Oncol."},{"key":"pmbad48f6bib37","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1016\/j.radonc.2018.07.027","article-title":"Texture analysis of 3D dose distributions for predictive modelling of toxicity rates in radiotherapy","volume":"129","author":"Rossi","year":"2018","journal-title":"Radiother. Oncol."},{"key":"pmbad48f6bib38","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/j.radonc.2020.07.056","article-title":"First experience with model-based selection of head and neck cancer patients for proton therapy","volume":"151","author":"Tambas","year":"2020","journal-title":"Radiother. Oncol."},{"key":"pmbad48f6bib39","doi-asserted-by":"publisher","first-page":"5451","DOI":"10.1002\/mp.15702","article-title":"Feasibility study of fast intensity-modulated proton therapy dose prediction method using deep neural networks for prostate cancer","volume":"49","author":"Wang","year":"2022","journal-title":"Med. Phys."},{"key":"pmbad48f6bib40","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.ijrobp.2015.10.004","article-title":"The quest for evidence for proton therapy: model-based approach and precision medicine","volume":"95","author":"Widder","year":"2016","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,23]],"date-time":"2025-08-23T10:54:15Z","timestamp":1755946455000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,30]]},"references-count":40,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2024,5,30]]},"published-print":{"date-parts":[[2024,6,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ad48f6","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,30]]},"assertion":[{"value":"Evaluation of an automated clinical decision system with deep learning dose prediction and NTCP model for prostate cancer proton therapy","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-12-08","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-08","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-30","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}