{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T18:24:04Z","timestamp":1789842244691,"version":"4.0.1"},"reference-count":26,"publisher":"IOP Publishing","issue":"11","license":[{"start":{"date-parts":[[2024,5,30]],"date-time":"2024-05-30T00:00:00Z","timestamp":1717027200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,30]],"date-time":"2024-05-30T00:00:00Z","timestamp":1717027200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Australian Synchrotron Access Program","award":["AS223\/IMBL\/18800"],"award-info":[{"award-number":["AS223\/IMBL\/18800"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2024,6,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> This study aims to characterize radiological properties of selected additive manufacturing (AM) materials utilizing both material extrusion and vat photopolymerization technologies. Monochromatic synchrotron x-ray images and synchrotron treatment beam dosimetry were acquired at the hutch 3B and 2B of the Australian Synchrotron-Imaging and Medical Beamline. <jats:italic>Approach.<\/jats:italic> Eight energies from 30 keV up to 65 keV were used to acquire the attenuation coefficients of the AM materials. Comparison of theoretical, and experimental attenuation data of AM materials and standard solid water for MV linac was performed. Broad-beam dosimetry experiment through attenuated dose measurement and a Geant4 Monte Carlo simulation were done for the studied materials to investigate its attenuation properties specific for a 4 tesla wiggler field with varying synchrotron radiation beam qualities. <jats:italic>Main results.<\/jats:italic> Polylactic acid (PLA) plus matches attenuation coefficients of both soft tissue and brain tissue, while acrylonitrile butadiene styrene, Acrylonitrile styrene acrylate, and Draft resin have close equivalence to adipose tissue. Lastly, PLA, co-polyester plus, thermoplastic polyurethane, and White resins are promising substitute materials for breast tissue. For broad-beam experiment and simulation, many of the studied materials were able to simulate RMI457 Solid Water and bolus within \u00b110% for the three synchrotron beam qualities. These results are useful in fabricating phantoms for synchrotron and other related medical radiation applications such as orthovoltage treatments. <jats:italic>Significance and conclusion.<\/jats:italic> These 3D printing materials were studied as potential substitutes for selected tissues such as breast tissue, adipose tissue, soft-tissue, and brain tissue useful in fabricating 3D printed phantoms for synchrotron imaging, therapy, and orthovoltage applications. Fabricating customizable heterogeneous anthropomorphic phantoms (e.g. breast, head, thorax) and pre-clinical animal phantoms (e.g. rodents, canine) for synchrotron imaging and radiotherapy using AM can be done based on the results of this study.<\/jats:p>","DOI":"10.1088\/1361-6560\/ad48f7","type":"journal-article","created":{"date-parts":[[2024,5,8]],"date-time":"2024-05-08T22:45:21Z","timestamp":1715208321000},"page":"115055","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":9,"title":["Characterization of selected additive manufacturing materials for synchrotron monochromatic imaging and broad-beam radiotherapy at the Australian synchrotron-imaging and medical beamline"],"prefix":"10.1088","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8052-0011","authenticated-orcid":true,"given":"John Paul O","family":"Bustillo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3648-7880","authenticated-orcid":false,"given":"Jason","family":"Paino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Micah","family":"Barnes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Cameron","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5116-6308","authenticated-orcid":true,"given":"Anatoly B","family":"Rosenfeld","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2406-9972","authenticated-orcid":false,"given":"Michael L F","family":"Lerch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,5,30]]},"reference":[{"key":"pmbad48f7bib1","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1177\/1533034617710579","article-title":"Characterization of water-clear polymeric gels for use as radiotherapy bolus","volume":"16","author":"Adamson","year":"2017","journal-title":"Technol. Cancer Res. Treat."},{"key":"pmbad48f7bib2","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.radphyschem.2017.02.009","article-title":"Evaluation of 3D printing materials for fabrication of a novel multi-functional 3D thyroid phantom for medical dosimetry and image quality","volume":"135","author":"Alssabbagh","year":"2017","journal-title":"Radiat. Phys. Chem."},{"key":"pmbad48f7bib3","doi-asserted-by":"publisher","first-page":"4120","DOI":"10.3390\/app11094120","article-title":"X-ray phase-contrast computed tomography for soft tissue imaging at the imaging and medical beamline (IMBL) of the Australian synchrotron","volume":"11","author":"Arhatari","year":"2021","journal-title":"Appl. Sci."},{"key":"pmbad48f7bib4","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.phro.2020.03.003","article-title":"A review of 3D printed patient specific immobilisation devices in radiotherapy","volume":"13","author":"Asfia","year":"2020","journal-title":"Phys. Imaging Radiat. Oncol."},{"key":"pmbad48f7bib5","author":"Berger","year":"2010"},{"key":"pmbad48f7bib6","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/j.mrrev.2009.12.003","article-title":"Effects of pulsed, spatially fractionated, microscopic synchrotron x-ray beams on normal and tumoral brain tissue","volume":"704","author":"Br\u00e4uer-Krisch","year":"2010","journal-title":"Mutat. Res."},{"key":"pmbad48f7bib7","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1120\/JACMP.V16I3.5247","article-title":"Use of 3D printers to create a patient-specific 3D bolus for external beam therapy","volume":"16","author":"Burleson","year":"2015","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbad48f7bib8","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2012.2216890","author":"Bushberg","year":"2011","edition":"3rd edn"},{"key":"pmbad48f7bib9","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1007\/978-981-10-9023-3_92","article-title":"Intensity modulated radiotherapy (IMRT) phantom fabrication using fused deposition modeling (FDM) 3D printing technique","volume":"68","author":"Bustillo","year":"2019","journal-title":"IFMBE Proc."},{"key":"pmbad48f7bib10","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1107\/S1600577517005641","article-title":"Comparison of phantom materials for use in quality assurance of microbeam radiation therapy","volume":"24","author":"Cameron","year":"2017","journal-title":"J. Synchrotron Radiat."},{"key":"pmbad48f7bib11","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-53991-9","article-title":"Validation of a Monte Carlo simulation for microbeam radiation therapy on the imaging and medical beamline at the Australian synchrotron","volume":"9","author":"Dipuglia","year":"2019","journal-title":"Sci. Rep."},{"key":"pmbad48f7bib12","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acaf4a","article-title":"Dual-energy CT evaluation of 3D printed materials for radiotherapy applications","volume":"68","author":"Fonseca","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbad48f7bib13","doi-asserted-by":"publisher","DOI":"10.1117\/12.893252","article-title":"Toolbox for advanced x-ray image processing","volume":"8141","author":"Gureyev","year":"2011","journal-title":"Proc. SPIE"},{"key":"pmbad48f7bib14","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/8\/06\/C06011","article-title":"Detectors for the imaging and medical beam line at the Australian synchrotron","volume":"8","author":"Hall","year":"2013","journal-title":"J. Instrum."},{"key":"pmbad48f7bib15","doi-asserted-by":"publisher","DOI":"10.1093\/jicru\/nd","volume":"vol 11","author":"International Commission on Radiation Units and Measurements (ICRU)","year":"2011","journal-title":"ICRU Report 85: Fundamental Quantities and Units for Ionizing Radiation"},{"key":"pmbad48f7bib16","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aad315","article-title":"Suitability of low density materials for 3D printing of physical breast phantoms","volume":"63","author":"Ivanov","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbad48f7bib17","author":"Khan","year":"2014","edition":"5th edn"},{"key":"pmbad48f7bib18","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.763960","article-title":"Classification of x-ray attenuation properties of additive manufacturing and 3D printing materials using computed tomography from 70 to 140 kVp","volume":"9","author":"Ma","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"pmbad48f7bib19","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac8966","article-title":"Attenuation coefficient in the energy range 14\u201336 keV of 3D printing materials for physical breast phantoms","volume":"67","author":"Mettivier","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbad48f7bib20","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1107\/S1600577515004579","article-title":"Dual-energy x-ray analysis using synchrotron computed tomography at 35 and 60 keV for the estimation of photon interaction coefficients describing attenuation and energy absorption","volume":"22","author":"Midgley","year":"2015","journal-title":"J. Synchrotron Radiat."},{"key":"pmbad48f7bib21","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1107\/S1600577518018015","article-title":"CT dosimetry at the Australian synchrotron for 25\u2013100 kev photons and 35\u2013160 mm-diameter biological specimens","volume":"26","author":"Midgley","year":"2019","journal-title":"J. Synchrotron Radiat."},{"key":"pmbad48f7bib22","doi-asserted-by":"publisher","first-page":"9101","DOI":"10.3390\/app11199101","article-title":"Incorporating clinical imaging into the delivery of microbeam radiation therapy","volume":"11","author":"Paino","year":"2021","journal-title":"Appl. Sci."},{"key":"pmbad48f7bib23","doi-asserted-by":"publisher","first-page":"1995","DOI":"10.3390\/ma14081995","article-title":"A micro-computed tomography comparison of the porosity in additively fabricated cucr1 alloy parts using virgin and surface-modified powders","volume":"14","author":"Sinico","year":"2021","journal-title":"Materials"},{"key":"pmbad48f7bib24","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1107\/S1600577516015563","article-title":"Quantitative characterization of the x-ray beam at the Australian synchrotron imaging and medical beamline (IMBL)","volume":"24","author":"Stevenson","year":"2017","journal-title":"J. Synchrotron Radiat."},{"key":"pmbad48f7bib25","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0031-9155\/48\/13\/201","article-title":"Medical applications of synchrotron radiation medical applications of synchrotron radiation","volume":"48","author":"Suortti","year":"2003","journal-title":"Phys. Med. Biol."},{"key":"pmbad48f7bib26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/1533033819870208","article-title":"A systematic review on 3D-printed imaging and dosimetry phantoms in radiation therapy","volume":"18","author":"Tino","year":"2019","journal-title":"Technol. Cancer Res. Treat."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,24]],"date-time":"2024-07-24T21:28:59Z","timestamp":1721856539000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad48f7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,30]]},"references-count":26,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2024,5,30]]},"published-print":{"date-parts":[[2024,6,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ad48f7","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,30]]},"assertion":[{"value":"Characterization of selected additive manufacturing materials for synchrotron monochromatic imaging and broad-beam radiotherapy at the Australian synchrotron-imaging and medical beamline","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-01-19","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-08","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-30","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}