{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:06:59Z","timestamp":1787008019647,"version":"build-2736575974"},"reference-count":24,"publisher":"IOP Publishing","issue":"17","license":[{"start":{"date-parts":[[2024,8,14]],"date-time":"2024-08-14T00:00:00Z","timestamp":1723593600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,14]],"date-time":"2024-08-14T00:00:00Z","timestamp":1723593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"ADEQUATE","award":["Dutch Science Organization (NWO) Applied Sciences"],"award-info":[{"award-number":["Dutch Science Organization (NWO) Applied Sciences"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2024,9,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    To ensure the accuracy of radiation delivery to patients in a 1.5 T MRI-linac, the implementation of quality assurance (QA) devices compatible with MR technology is essential. The OCTAVIUS 4D MR, made by PTW (Freiburg, Germany) is designed to ensure consistent and ideal alignment of its detectors with the direction of each beam segment. This study focuses on investigating the fundamental characteristics of the detector response for the OCTAVIUS Detector (OD) 1500 MR and OCTAVIUS 1600 MR when used in the MR-compatible OCTAVIUS 4D. Characteristics examined included short-term reproducibility, dose linearity, field size dependency, monitor unit (MU) rate dependency, dose-per-pulse dependency, and angular dependency. The evaluation of OD 1500 MR also involved measuring 25 clinical treatment plans across diverse target sizes and anatomical sites, including the liver\/pancreas, rectum, prostate, lungs, and lymph nodes. One plan was measured with the standard setup and with a 5 cm left offset. The OD 1600 MR was not available for these measurements. The capability of the OD 1500 MR to identify potential errors was assessed by introducing a MU and positional shift within the software. The results demonstrated no significant differences in short-term reproducibility (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:mo>&lt;<\/mml:mo>\n                          <\/mml:mrow>\n                          <mml:mn>0.2<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ), dose linearity (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:mo>&lt;<\/mml:mo>\n                          <\/mml:mrow>\n                          <mml:mn>1<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ), field size dependency (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:mo>&lt;<\/mml:mo>\n                          <\/mml:mrow>\n                          <mml:mn>0.7<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    for field sizes larger than 5 cm \u00d7 5 cm), MU rate dependency (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:mo>&lt;<\/mml:mo>\n                          <\/mml:mrow>\n                          <mml:mn>0.8<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ), dose-per-pulse dependency (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:mo>&lt;<\/mml:mo>\n                          <\/mml:mrow>\n                          <mml:mn>0.4<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) and angular dependency (standard deviation\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:mo>&lt;<\/mml:mo>\n                          <\/mml:mrow>\n                          <mml:mn>0.5<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ). All tests of clinical plans were successfully completed. The OD 1500 MR demonstrated compatibility with the standard 95% pass rate when employing a global 3%\/3 mm gamma criterion, and a 90% pass rate using a global 2%\/2 mm gamma criterion. The detector demonstrated the capacity to measure treatment plans with a 5 cm left offset. With the standard parameters, the gamma test was sensitive to position errors but required an addition tests of mean\/median dose or point dose in order to detect small dose difference.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ad67a2","type":"journal-article","created":{"date-parts":[[2024,7,25]],"date-time":"2024-07-25T18:54:05Z","timestamp":1721933645000},"page":"17NT01","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["MR-OCTAVIUS 4D with 1500 MR and 1600 MR arrays is suitable for plan QA in a 1.5 T MRI-linac"],"prefix":"10.1088","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-3265-8176","authenticated-orcid":true,"given":"Viktoriia","family":"Gorobets","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wilfred de","family":"Vries","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicole","family":"Brand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Foppen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9 J M","family":"Wopereis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Woodings","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,8,14]]},"reference":[{"key":"pmbad67a2bib1","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.radmeas.2013.08.009","article-title":"Evaluation of a liquid ionization chamber for relative dosimetry in small and large fields of radiotherapy photon beams","volume":"58","author":"Ben\u00edtez","year":"2013","journal-title":"Radiat. Meas."},{"key":"pmbad67a2bib2","article-title":"Quality assurance with OCTAVIUS detector 1600 SRS at the CyberKnife","author":"Brand","year":"2022"},{"key":"pmbad67a2bib3","doi-asserted-by":"publisher","first-page":"5359","DOI":"10.1118\/1.3238104","article-title":"TG-119 IMRT commissioning tests instructions for planning, measurement and analysis","volume":"36","author":"Ezzell","year":"2009","journal-title":"Med. Phys."},{"key":"pmbad67a2bib4","doi-asserted-by":"publisher","first-page":"2089","DOI":"10.1118\/1.1591194","article-title":"Guidance document on delivery, treatment planning and clinical implementation of IMRT: report of the IMRT subcommittee of the AAPM radiation therapy committee","volume":"30","author":"Ezzell","year":"2003","journal-title":"Med. Phys."},{"key":"pmbad67a2bib5","doi-asserted-by":"publisher","DOI":"10.1118\/1.4789580","article-title":"On the sensitivity of common gamma-index evaluation methods to MLC misalignments in Rapidarc quality assurance","volume":"40","author":"Heilemann","year":"2013","journal-title":"Med. Phys."},{"key":"pmbad67a2bib6","doi-asserted-by":"publisher","first-page":"N80","DOI":"10.1088\/0031-9155\/61\/3\/N80","article-title":"Performance of a cylindrical diode array for use in a 1.5 T MR-linac","volume":"61","author":"Houweling","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"pmbad67a2bib7","author":"International Atomic Energy Agency","year":"2017"},{"key":"pmbad67a2bib8","doi-asserted-by":"publisher","first-page":"2476","DOI":"10.1118\/1.4946822","article-title":"Investigating ion recombination effects in a liquid-filled ionization chamber array used for IMRT QA measurements","volume":"43","author":"Knill","year":"2016","journal-title":"Med. Phys."},{"key":"pmbad67a2bib9","first-page":"pp 207","article-title":"The magnetic resonance imaging\u2013linac system","volume":"vol 24","author":"Lagendijk","year":"2014"},{"key":"pmbad67a2bib10","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1118\/1.1544678","article-title":"The volume effect of detectors in the dosimetry of small fields used in IMRT","volume":"30","author":"Laub","year":"2003","journal-title":"Med. Phys."},{"key":"pmbad67a2bib11","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1118\/1.598248","article-title":"A technique for the quantitative evaluation of dose distributions","volume":"25","author":"Low","year":"1998","journal-title":"Med. Phys."},{"key":"pmbad67a2bib12","doi-asserted-by":"publisher","DOI":"10.1118\/1.4870439","article-title":"Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy","volume":"41","author":"Markovic","year":"2014","journal-title":"Med. Phys."},{"key":"pmbad67a2bib13","doi-asserted-by":"publisher","first-page":"1131","DOI":"10.1088\/0031-9155\/46\/4\/316","article-title":"The value of the LA48 linear ion chamber array for characterization of intensity-modulated beams","volume":"46","author":"Martens","year":"2001","journal-title":"Phys. Med. Biol."},{"key":"pmbad67a2bib14","doi-asserted-by":"publisher","first-page":"e53","DOI":"10.1002\/mp.12810","article-title":"Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218","volume":"45","author":"Miften","year":"2018","journal-title":"Med. Phys."},{"key":"pmbad67a2bib15","doi-asserted-by":"publisher","first-page":"16NT01","DOI":"10.1088\/1361-6560\/aba5ec","article-title":"Quality assurance of IMRT treatment plans for a 1.5 T MR-linac using a 2D ionization chamber array and a static solid phantom","volume":"65","author":"M\u00f6nnich","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbad67a2bib16","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1002\/acm2.12610","article-title":"Transit and non-transit 3D EPID dosimetry versus detector arrays for patient specific QA","volume":"20","author":"Olaciregui-Ruiz","year":"2019","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbad67a2bib17","doi-asserted-by":"publisher","first-page":"3700","DOI":"10.1118\/1.2349691","article-title":"Experimental determination of the effect of detector size on profile measurements in narrow photon beams","volume":"33","author":"Pappas","year":"2006","journal-title":"Med. Phys."},{"key":"pmbad67a2bib18","doi-asserted-by":"publisher","first-page":"3677","DOI":"10.1088\/0031-9155\/54\/12\/005","article-title":"Determining charge collection efficiency in parallel-plate liquid ionization chambers","volume":"54","author":"Pardo-Montero","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmbad67a2bib19","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1118\/1.2179167","article-title":"Two-dimensional ionization chamber arrays for IMRT plan verification","volume":"33","author":"Poppe","year":"2006","journal-title":"Med. Phys."},{"key":"pmbad67a2bib20","article-title":"OCTAVIUS\u00ae based plan verification at a MRIdian\u00ae linac","author":"Poppinga","year":"2021"},{"key":"pmbad67a2bib21","doi-asserted-by":"publisher","first-page":"e67","DOI":"10.1002\/mp.14764","article-title":"Machine QA for the Elekta Unity system: a report from the Elekta MR-linac consortium","volume":"48","author":"Roberts","year":"2021","journal-title":"Med. Phys."},{"key":"pmbad67a2bib22","doi-asserted-by":"publisher","first-page":"1528","DOI":"10.1118\/1.4914151","article-title":"Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500","volume":"42","author":"Stelljes","year":"2015","journal-title":"Med. Phys."},{"key":"pmbad67a2bib23","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1093\/jrr\/rrx088","article-title":"General ion recombination effect in a liquid ionization chamber in high-dose-rate pulsed photon and electron beams","volume":"59","author":"Takei","year":"2018","journal-title":"J. Radiat. Res."},{"key":"pmbad67a2bib24","doi-asserted-by":"publisher","DOI":"10.1118\/1.4892178","article-title":"The OCTAVIUS1500 2D ion chamber array and its associated phantoms: dosimetric characterization of a new prototype","volume":"41","author":"Van Esch","year":"2014","journal-title":"Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,14]],"date-time":"2024-08-14T00:45:46Z","timestamp":1723596346000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad67a2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,14]]},"references-count":24,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2024,8,14]]},"published-print":{"date-parts":[[2024,9,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ad67a2","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,14]]},"assertion":[{"value":"MR-OCTAVIUS 4D with 1500 MR and 1600 MR arrays is suitable for plan QA in a 1.5 T MRI-linac","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-04-12","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-07-25","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-08-14","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}