{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T20:19:08Z","timestamp":1781813948335,"version":"3.54.5"},"reference-count":41,"publisher":"IOP Publishing","issue":"22","license":[{"start":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T00:00:00Z","timestamp":1731283200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T00:00:00Z","timestamp":1731283200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Innovative project of the State Key Laboratory of Radiation Medicine and Protection","award":["GZC00401"],"award-info":[{"award-number":["GZC00401"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["12105200"],"award-info":[{"award-number":["12105200"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"the National Key R&D Program of China","award":["2022YFC2503204"],"award-info":[{"award-number":["2022YFC2503204"]}]},{"name":"China Baoyuan Scientific Research Foundation","award":["2021(270001)"],"award-info":[{"award-number":["2021(270001)"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2024,11,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The method combining Monte Carlo (MC) simulation and mesh-type cell models provides a way to accurately assess the cellular dose induced by <jats:italic>\u03b2<\/jats:italic>-emitters. Although this approach allows for a specific evaluation of various nuclides and cell type combinations, the associated time cost for obtaining results is relatively high. In this work, we propose a Microdosimetric assessment method for Internal exposure of <jats:italic>\u03b2<\/jats:italic>-emitters based on Mesh-type Cell cluster models (abbreviated as MIMC-<jats:italic>\u03b2<\/jats:italic>). This approach is applied to evaluate the dose in various types of cells (human bronchial epithelial cells, BEAS-2B; normal human liver cells, L-O2; and normal human small intestine epithelial cells, FHs74Int) exposed to <jats:italic>\u03b2<\/jats:italic>-emitters. Furthermore, microdosimetric quantity based on the cell cluster model are employed to estimate the relative biological effectiveness (RBE) of <jats:italic>\u03b2<\/jats:italic>-emitters. The results indicate that this method can accurately and rapidly predict cellular doses caused by different types of <jats:italic>\u03b2<\/jats:italic>-emitters, significantly mitigating the efficiency challenges associated with directly employing MC to estimate the overall dose of the mesh-type cell cluster model. In comparison with results obtained from direct simulations of uniform administration of <jats:italic>\u03b2<\/jats:italic>- sources using PHITS for validation, the cellular cluster overall <jats:italic>S<\/jats:italic>-values obtained through MIMC-<jats:italic>\u03b2<\/jats:italic> show discrepancies mostly below 5%, with the minimum deviation reaching 1.35%. Small sampling sizes within the cell nucleus led to larger average lineal energies. In comparison to C-14, the differences in cellular cluster average lineal energy for Cs-134, Cs-137, and I-131 are negligible, resulting in close numerical estimations of RBE based on lineal energy. The MIMC-<jats:italic>\u03b2<\/jats:italic> can be extended to diverse cell types and <jats:italic>\u03b2<\/jats:italic>-emitters. Additionally, the RBE assessment based on the cell cluster model offers valuable insights for predicting radiobiological damage resulting from internal exposure by <jats:italic>\u03b2<\/jats:italic>-emitters. This method is expected to find applicability in various realistic scenarios, including radiation protection and radioligand therapy.<\/jats:p>","DOI":"10.1088\/1361-6560\/ad8c92","type":"journal-article","created":{"date-parts":[[2024,10,29]],"date-time":"2024-10-29T22:57:22Z","timestamp":1730242642000},"page":"225007","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["MIMC-\u03b2: microdosimetric assessment method for internal exposure of \u03b2-emitters based on mesh-type cell cluster model"],"prefix":"10.1088","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1153-0301","authenticated-orcid":false,"given":"Yidi","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinlei","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianghui","family":"Kong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinjie","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaijin","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9216-1439","authenticated-orcid":true,"given":"Yu","family":"Tu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8124-0801","authenticated-orcid":true,"given":"Liang","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,11,11]]},"reference":[{"key":"pmbad8c92bib1","doi-asserted-by":"publisher","first-page":"477","DOI":"10.2967\/jnumed.108.056036","article-title":"MIRD pamphlet no. 21: a generalized schema for radiopharmaceutical dosimetry\u2014standardization of nomenclature","volume":"50","author":"Bolch","year":"2009","journal-title":"J. Nucl. Med."},{"key":"pmbad8c92bib2","doi-asserted-by":"publisher","first-page":"339","DOI":"10.2967\/jnumed.116.175695","article-title":"Monte Carlo N-particle (MCNP) modeling of the cellular dosimetry of 64Cu: comparison with MIRDcell S values and implications for studies of its cytotoxic effects","volume":"58","author":"Cai","year":"2017","journal-title":"J. Nucl. Med."},{"key":"pmbad8c92bib3","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.jrras.2015.03.003","article-title":"Targeted and non-targeted effects of ionizing radiation","volume":"8","author":"Desouky","year":"2015","journal-title":"J. Radiat. Res. Appl. Sci."},{"key":"pmbad8c92bib4","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.ejmp.2022.08.006","article-title":"Research on the proximity functions of microdosimetry of low energy electrons in liquid water based on different Monte Carlo codes","volume":"101","author":"Du","year":"2022","journal-title":"Phys. Med."},{"key":"pmbad8c92bib5","doi-asserted-by":"publisher","first-page":"3206","DOI":"10.1118\/1.1626990","article-title":"Summary and recommendations of a National Cancer Institute workshop on issues limiting the clinical use of Monte Carlo dose calculation algorithms for megavoltage external beam radiation therapy","volume":"30","author":"Fraass","year":"2003","journal-title":"Med. Phys."},{"key":"pmbad8c92bib6","first-page":"303","article-title":"Cellular dosimetry: absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments","volume":"35","author":"Goddu","year":"1994a","journal-title":"J. Nucl. Med."},{"key":"pmbad8c92bib7","doi-asserted-by":"publisher","first-page":"909","DOI":"10.3109\/02841869609104045","article-title":"Calculation of equivalent dose for Auger electron emitting radionuclides distributed in human organs","volume":"35","author":"Goddu","year":"1996","journal-title":"Acta Oncol."},{"key":"pmbad8c92bib8","first-page":"521","article-title":"Multicellular dosimetry for micrometastases: dependence of self-dose versus cross-dose to cell nuclei on type and energy of radiation and subcellular distribution of radionuclides","volume":"35","author":"Goddu","year":"1994b","journal-title":"J. Nucl. Med."},{"key":"pmbad8c92bib9","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1093\/oxfordjournals.rpd.a006722","article-title":"Uncertainties in dose coefficients for intakes of tritiated water and organically bound forms of tritium by members of the public","volume":"98","author":"Harrison","year":"2002","journal-title":"Radiat. Prot. Dosimetry"},{"key":"pmbad8c92bib10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/0955300021000038671","article-title":"Quantitative comparisons of cancer induction in humans by internally deposited radionuclides and external radiation","volume":"79","author":"Harrison","year":"2003","journal-title":"Int. J. Radiat. Biol."},{"key":"pmbad8c92bib11","doi-asserted-by":"publisher","first-page":"366","DOI":"10.2307\/3579114","article-title":"A statistical theory of cell killing by radiation of varying linear energy transfer","volume":"140","author":"Hawkins","year":"1994","journal-title":"Radiat. Res."},{"key":"pmbad8c92bib12","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1080\/095530096145481","article-title":"A microdosimetric-kinetic model of cell death from exposure to ionizing radiation of any LET, with experimental and clinical applications","volume":"69","author":"Hawkins","year":"1996","journal-title":"Int. J. Radiat. Biol."},{"key":"pmbad8c92bib13","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1118\/1.598307","article-title":"A microdosimetric-kinetic theory of the dependence of the RBE for cell death on LET","volume":"25","author":"Hawkins","year":"1998","journal-title":"Med. Phys."},{"key":"pmbad8c92bib14","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1667\/RR3010","article-title":"A microdosimetric-kinetic model for the effect of non-Poisson distribution of lethal lesions on the variation of RBE with LET","volume":"160","author":"Hawkins","year":"2003","journal-title":"Radiat. Res."},{"key":"pmbad8c92bib15","author":"Hirayama","year":"2005"},{"key":"pmbad8c92bib16","article-title":"Nuclear decay data for dosimetric calculations","author":"ICRP","year":"2008"},{"key":"pmbad8c92bib17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.radphyschem.2015.05.021","article-title":"Thermal equilibrium and prehydration processes of electrons injected into liquid water calculated by dynamic Monte Carlo method","volume":"115","author":"Kai","year":"2015","journal-title":"Radiat. Phys. Chem."},{"key":"pmbad8c92bib18","doi-asserted-by":"publisher","first-page":"3989","DOI":"10.1007\/s00259-022-05878-7","article-title":"Predicting response of micrometastases with MIRDcell V3: proof of principle with 225Ac-DOTA encapsulating liposomes that produce different activity distributions in tumor spheroids","volume":"49","author":"Katugampola","year":"2022a","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbad8c92bib19","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.2967\/jnumed.121.263253","article-title":"MIRD pamphlet no. 27: MIRDcell V3, a revised software tool for multicellular dosimetry and bioeffect modeling","volume":"63","author":"Katugampola","year":"2022b","journal-title":"J. Nucl. Med."},{"key":"pmbad8c92bib20","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acec2b","article-title":"Microdosimetric assessment about proton spread-out Bragg peak at different depths based on the normal human mesh-type cell population model","volume":"68","author":"Kong","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbad8c92bib21","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2023.111284","article-title":"Microdosimetric analysis of monoenergetic electrons and beta-emitting radionuclides based on mesh-type cell models and RBE prediction","volume":"214","author":"Kong","year":"2024","journal-title":"Radiat. Phys. Chem."},{"key":"pmbad8c92bib22","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1186\/s40658-023-00564-5","article-title":"A GATE simulation study for dosimetry in cancer cell and micrometastasis from the 225Ac decay chain","volume":"10","author":"Koniar","year":"2023","journal-title":"EJNMMI Phys."},{"key":"pmbad8c92bib23","doi-asserted-by":"publisher","DOI":"10.1063\/1.4992076","article-title":"Microdosimetry of electrons in liquid water using the low-energy models of Geant4","volume":"122","author":"Kyriakou","year":"2017","journal-title":"J. Appl. Phys."},{"key":"pmbad8c92bib24","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1667\/RR15081.1","article-title":"Modeling cell and tumor-metastasis dosimetry with the particle and heavy ion transport code system (PHITS) software for targeted alpha-particle radionuclide therapy","volume":"190","author":"Lee","year":"2018","journal-title":"Radiat. Res."},{"key":"pmbad8c92bib25","doi-asserted-by":"publisher","first-page":"1484","DOI":"10.1080\/09553002.2019.1642537","article-title":"Development of computational model for cell dose and DNA damage quantification of multicellular system","volume":"95","author":"Liu","year":"2019","journal-title":"Int. J. Radiat. Biol."},{"key":"pmbad8c92bib26","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1007\/s004110000081","article-title":"Calculation of radiation-induced DNA damage from photons and tritium beta-particles: part II: tritium RBE and damage complexity","volume":"40","author":"Moiseenko","year":"2001","journal-title":"Radiat. Environ. Biophys."},{"key":"pmbad8c92bib27","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1016\/j.radmeas.2006.07.013","article-title":"PHITS\u2014a particle and heavy ion transport code system","volume":"41","author":"Niita","year":"2006","journal-title":"Radiat. Meas."},{"key":"pmbad8c92bib28","doi-asserted-by":"publisher","first-page":"18","DOI":"10.3390\/qubs8030018","article-title":"comparative evaluation of two analytical functions for the microdosimetry of ions from 1H to 238U","volume":"8","author":"Parisi","year":"2024","journal-title":"QuBS"},{"key":"pmbad8c92bib29","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1080\/00223131.2017.1419890","article-title":"Features of particle and heavy ion transport code system (PHITS) version 3.02","volume":"55","author":"Sato","year":"2018","journal-title":"J. Nucl. Sci. Technol."},{"key":"pmbad8c92bib30","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1667\/RR1510.1","article-title":"Biological dose estimation for charged-particle therapy using an improved PHITS code coupled with a microdosimetric kinetic model","volume":"171","author":"Sato","year":"2009","journal-title":"Radiat. Res."},{"key":"pmbad8c92bib31","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0099831","article-title":"Microdosimetric analysis confirms similar biological effectiveness of external exposure to gamma-rays and internal exposure to 137Cs, 134Cs, and 131I","volume":"9","author":"Sato","year":"2014","journal-title":"PLoS One"},{"key":"pmbad8c92bib32","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ace14c","article-title":"Improvement of the hybrid approach between Monte Carlo simulation and analytical function for calculating microdosimetric probability densities in macroscopic matter","volume":"68","author":"Sato","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbad8c92bib33","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1093\/rpd\/ncl407","article-title":"Development of a calculation method for estimating specific energy distribution in complex radiation fields","volume":"122","author":"Sato","year":"2006","journal-title":"Radiat. Prot. Dosimetry"},{"key":"pmbad8c92bib34","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40658-020-0276-5","article-title":"Cellular dosimetry of [177 Lu] Lu-DOTA-[Tyr 3] octreotate radionuclide therapy: the impact of modeling assumptions on the correlation with in vitro cytotoxicity","volume":"7","author":"Tamborino","year":"2020","journal-title":"EJNMMI Phys."},{"key":"pmbad8c92bib35","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.121.262610","article-title":"Modeling early radiation DNA damage occurring during [177 Lu]Lu-DOTA-[Tyr 3]octreotate radionuclide therapy","volume":"121","author":"Tamborino","year":"2021","journal-title":"J. Nucl. Med."},{"key":"pmbad8c92bib36","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.2967\/jnumed.113.131037","article-title":"MIRD pamphlet no. 25: MIRDcell V2. 0 software tool for dosimetric analysis of biologic response of multicellular populations","volume":"55","author":"Vaziri","year":"2014","journal-title":"J. Nucl. Med."},{"key":"pmbad8c92bib37","doi-asserted-by":"publisher","DOI":"10.1016\/j.cpc.2021.108228","article-title":"Pyg4ometry: a python library for the creation of Monte Carlo radiation transport physical geometries","volume":"272","author":"Walker","year":"2022","journal-title":"Comput. Phys. Commun."},{"key":"pmbad8c92bib38","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1667\/RADE-23-00020.1","article-title":"Multiple mesh-type real human cell models for dosimetric application coupled with Monte Carlo simulations","volume":"200","author":"Wang","year":"2023","journal-title":"Radiat. Res."},{"key":"pmbad8c92bib39","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-62501-5","article-title":"A comparative study on the dose\u2013effect of low-dose radiation based on microdosimetric analysis and single-cell sequencing technology","volume":"14","author":"Wang","year":"2024","journal-title":"Sci. Rep."},{"key":"pmbad8c92bib40","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1093\/jrr\/rrz076","article-title":"The influence of Geant4-DNA toolkit parameters on electron microdosimetric track structure","volume":"61","author":"Wang","year":"2020","journal-title":"J. Radiat. Res."},{"key":"pmbad8c92bib41","doi-asserted-by":"publisher","first-page":"2601","DOI":"10.3748\/wjg.v12.i16.2601","article-title":"Comparison of clonogenic assay with premature chromosome condensation assay in prediction of human cell radiosensitivity","volume":"12","author":"Wang","year":"2006","journal-title":"World J. Gastroenterology"}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T10:51:31Z","timestamp":1731322291000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad8c92"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,11]]},"references-count":41,"journal-issue":{"issue":"22","published-online":{"date-parts":[[2024,11,11]]},"published-print":{"date-parts":[[2024,11,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ad8c92","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,11]]},"assertion":[{"value":"MIMC-\u03b2: microdosimetric assessment method for internal exposure of \u03b2-emitters based on mesh-type cell cluster model","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-01-12","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-10-29","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-11-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}