{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T17:46:49Z","timestamp":1781804809153,"version":"3.54.5"},"reference-count":37,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2024,12,24]],"date-time":"2024-12-24T00:00:00Z","timestamp":1734998400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,12,24]],"date-time":"2024-12-24T00:00:00Z","timestamp":1734998400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100003246","name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","doi-asserted-by":"crossref","award":["17515"],"award-info":[{"award-number":["17515"]}],"id":[{"id":"10.13039\/501100003246","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2025,1,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> Inter- and intra-fractional anatomical changes during a radiotherapy treatment can cause differences between the initially planned dose and the delivered dose. The total delivered dose can be accumulated over all fractions by using deformable image registration (DIR). However, there is uncertainty in this process which should be accounted for. The aim of this study is to propose a novel metric estimating the spatial distribution of the accumulated dose uncertainty and to evaluate its performance for multi-fraction online adaptive treatments. <jats:italic>Approach.<\/jats:italic> We postulate a new metric, the delta (<jats:italic>\u03b4<\/jats:italic>) index, to estimate the uncertainties associated with the dose accumulation process. This metric is calculated for each voxel and takes into account the spatial uncertainty in DIR and local dose differences. For the spatial uncertainty of the DIR, the distance discordance metric was used. The accumulated dose and the <jats:italic>\u03b4<\/jats:italic> index were determined for ten lung stereotactic body radiation therapy patients. The <jats:italic>\u03b4<\/jats:italic> index was complemented by a more understandable metric, the <jats:italic>\u03b4<\/jats:italic> index passing rate, which is the percentage of points satisfying the passing criteria in a region. <jats:italic>Main results.<\/jats:italic> The spatial distribution of the <jats:italic>\u03b4<\/jats:italic> index and the <jats:italic>\u03b4<\/jats:italic> index passing rates showed that voxels failing the criteria were predominantly in lower-dose regions. The mean percentage of voxels passing the criterion increased from 65% to 78%, for threshold doses of 20% and 90% of the prescription doses, respectively. <jats:italic>Significance.<\/jats:italic> The <jats:italic>\u03b4<\/jats:italic> index was postulated to quantify the spatial distribution of the uncertainties associated with the dose accumulation process. The metric gives an intuitive understanding of the reliability of accumulated dose distributions and derived DVH metrics. The performance of the <jats:italic>\u03b4<\/jats:italic> index was evaluated for multi-fraction online adaptive treatments, where a case of sub-optimal image registration was identified by the metric.<\/jats:p>","DOI":"10.1088\/1361-6560\/ad9dae","type":"journal-article","created":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T23:02:26Z","timestamp":1733958146000},"page":"015003","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Quantifying the spatial distribution of the accumulated dose uncertainty using the novel delta index"],"prefix":"10.1088","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9671-8062","authenticated-orcid":true,"given":"Madelon","family":"van den Dobbelsteen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara L","family":"Hackett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8206-271X","authenticated-orcid":true,"given":"Lando S","family":"Bosma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-4965-9872","authenticated-orcid":true,"given":"Renate J A","family":"van Doormaal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bram","family":"van Asselen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9107-4627","authenticated-orcid":true,"given":"Martin F","family":"Fast","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,12,24]]},"reference":[{"key":"pmbad9daebib1","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1002\/mp.15320","article-title":"Identification of modes of tumor regression in non-small cell lung cancer patients during radiotherapy","volume":"49","author":"Amugongo","year":"2022","journal-title":"Med. Phys."},{"key":"pmbad9daebib2","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1016\/j.clon.2020.07.023","article-title":"Complex clinical decision-making process of re-irradiation","volume":"32","author":"Armstrong","year":"2020","journal-title":"Clin. Oncol."},{"key":"pmbad9daebib3","doi-asserted-by":"publisher","first-page":"689","DOI":"10.21037\/tlcr.2017.09.02","article-title":"Magnetic resonance imaging in precision radiation therapy for lung cancer","volume":"6","author":"Bainbridge","year":"2017","journal-title":"Transl. Lung Cancer Res."},{"key":"pmbad9daebib4","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.radonc.2021.01.022","article-title":"Dose accumulation for personalized stereotactic MR-guided adaptive radiation therapy in prostate cancer","volume":"157","author":"Bohoudi","year":"2021","journal-title":"Radiother. Oncol."},{"key":"pmbad9daebib5","doi-asserted-by":"publisher","first-page":"S505","DOI":"10.1016\/S0167-8140(23)08674-7","article-title":"Oc-0618 recommendations for validation and verification of deformable image registration in radiotherapy","volume":"182","author":"Bosma","year":"2023","journal-title":"Radiother. Oncol."},{"key":"pmbad9daebib6","doi-asserted-by":"publisher","first-page":"e43","DOI":"10.1002\/mp.12256","article-title":"Use of image registration and fusion algorithms and techniques in radiotherapy: report of the AAPM Radiation Therapy Committee Task Group No. 132","volume":"44","author":"Brock","year":"2017","journal-title":"Med. Phys."},{"key":"pmbad9daebib7","doi-asserted-by":"publisher","first-page":"2710","DOI":"10.3390\/cancers16152710","article-title":"Harnessing the power of radiotherapy for lung cancer: a narrative review of the evolving role of magnetic resonance imaging guidance","volume":"16","author":"Cheng","year":"2024","journal-title":"Cancers"},{"key":"pmbad9daebib8","doi-asserted-by":"publisher","DOI":"10.1088\/0266-5611\/24\/3\/034008","article-title":"Ill-posed medicine\u2014an introduction to image registration","volume":"24","author":"Fischer","year":"2008","journal-title":"Inverse Problems"},{"key":"pmbad9daebib9","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.973067","article-title":"Adaptive dose painting for prostate cancer","volume":"12","author":"Freden","year":"2022","journal-title":"Front. Oncol."},{"key":"pmbad9daebib10","doi-asserted-by":"publisher","first-page":"3023","DOI":"10.1088\/0031-9155\/58\/9\/3023","article-title":"Estimation of the uncertainty of elastic image registration with the demons algorithm","volume":"58","author":"Hub","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbad9daebib11","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aca94d","article-title":"Detailed dosimetric evaluation of inter-fraction and respiratory motion in lung stereotactic body radiation therapy based on daily 4D cone beam ct images","volume":"68","author":"Huesa-Berral","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbad9daebib12","author":"Joiner","year":"2009","edition":"4th edn"},{"key":"pmbad9daebib13","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1088\/0031-9155\/59\/1\/173","article-title":"Direct dose mapping versus energy\/mass transfer mapping for 4D dose accumulation: fundamental differences and dosimetric consequences","volume":"59","author":"Li","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbad9daebib14","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.phro.2022.05.002","article-title":"Towards mid-position based stereotactic body radiation therapy on the mr-linac for central lung tumours","volume":"23","author":"Ligtenberg","year":"2022","journal-title":"Phys. Imaging Radiat. Oncol."},{"key":"pmbad9daebib15","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1118\/1.598248","article-title":"A technique for the quantitative evaluation of dose distributions","volume":"25","author":"Low","year":"1998","journal-title":"Med. Phys."},{"key":"pmbad9daebib16","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1002\/acm2.12220","article-title":"Intra-and inter-fractional liver and lung tumor motions treated with SBRT under active breathing control","volume":"19","author":"Lu","year":"2018","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbad9daebib17","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.ejmp.2017.02.003","article-title":"MRI-guided lung SBRT: present and future developments","volume":"44","author":"Menten","year":"2017","journal-title":"Phys. Med."},{"key":"pmbad9daebib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ctro.2024.100744","article-title":"Stereotactic body radiotherapy of central lung tumours using a 1.5 T MR-linac: first clinical experiences","volume":"45","author":"Merckel","year":"2024","journal-title":"Clin. Transl. Radiat. Oncol."},{"key":"pmbad9daebib19","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1118\/1.3673772","article-title":"A method to estimate the effect of deformable image registration uncertainties on daily dose mapping","volume":"39","author":"Murphy","year":"2012","journal-title":"Med. Phys."},{"key":"pmbad9daebib20","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2023.109527","article-title":"Applicability and usage of dose mapping\/accumulation in radiotherapy","volume":"182","author":"Murr","year":"2023","journal-title":"Radiother. Oncol."},{"key":"pmbad9daebib21","doi-asserted-by":"publisher","first-page":"e196","DOI":"10.1016\/j.prro.2018.11.005","article-title":"Tumor control and toxicity after SBRT for ultracentral, central and paramediastinal lung tumors","volume":"9","author":"Nguyen","year":"2019","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbad9daebib22","doi-asserted-by":"publisher","first-page":"101","DOI":"10.3857\/roj.2017.00325","article-title":"Deformable image registration in radiation therapy","volume":"35","author":"Oh","year":"2017","journal-title":"Radiat. Oncol. J."},{"key":"pmbad9daebib23","doi-asserted-by":"publisher","first-page":"e908","DOI":"10.1002\/mp.13162","article-title":"Patient-specific validation of deformable image registration in radiation therapy: overview and caveats","volume":"45","author":"Paganelli","year":"2018","journal-title":"Med. Phys."},{"key":"pmbad9daebib24","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1097\/JTO.0b013e3182614bf3","article-title":"Stereotactic body radiotherapy for central lung tumors","volume":"7","author":"Rowe","year":"2012","journal-title":"J. Thorac. Oncol."},{"key":"pmbad9daebib25","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1088\/0031-9155\/59\/3\/733","article-title":"The distance discordance metric\u2014a novel approach to quantifying spatial uncertainties in intra-and inter-patient deformable image registration","volume":"59","author":"Saleh","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbad9daebib26","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1118\/1.3528201","article-title":"Estimation of three-dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping","volume":"38","author":"Salguero","year":"2011","journal-title":"Med. Phys."},{"key":"pmbad9daebib27","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1118\/1.4938412","article-title":"Effect of deformable registration uncertainty on lung SBRT dose accumulation","volume":"43","author":"Samavati","year":"2016","journal-title":"Med. Phys."},{"key":"pmbad9daebib28","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.ejmp.2017.09.121","article-title":"Deformable image registration applied to lung SBRT: usefulness and limitations","volume":"44","author":"Sarrut","year":"2017","journal-title":"Phys. Medica"},{"key":"pmbad9daebib29","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20170522","article-title":"Initial clinical observations of intra-and interfractional motion variation in MR-guided lung SBRT","volume":"91","author":"Thomas","year":"2018","journal-title":"Br. J. Radiol."},{"key":"pmbad9daebib30","doi-asserted-by":"publisher","first-page":"4833","DOI":"10.1200\/JCO.2006.07.5937","article-title":"Excessive toxicity when treating central tumors in a phase II study of stereotactic body radiation therapy for medically inoperable early-stage lung cancer","volume":"24","author":"Timmerman","year":"2006","journal-title":"J. Clin. Oncol."},{"key":"pmbad9daebib31","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.radonc.2019.06.007","article-title":"MRI-guided mid-position liver radiotherapy: validation of image processing and registration steps","volume":"138","author":"van de Lindt","year":"2019","journal-title":"Radiother. Oncol."},{"key":"pmbad9daebib32","doi-asserted-by":"publisher","first-page":"S700","DOI":"10.1016\/S0167-8140(21)07144-9","article-title":"The delta index: a novel metric to assess dose accumulation uncertainty in MR-guided radiotherapy","volume":"161","author":"van den Dobbelsteen","year":"2021","journal-title":"Radiother. Oncol."},{"key":"pmbad9daebib33","doi-asserted-by":"publisher","first-page":"N391","DOI":"10.1088\/1361-6560\/aa8133","article-title":"Representing the dosimetric impact of deformable image registration errors","volume":"62","author":"Vickress","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"pmbad9daebib34","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TIP.2003.819861","article-title":"Image quality assessment: from error visibility to structural similarity","volume":"13","author":"Wang","year":"2004","journal-title":"IEEE Trans. Image Process."},{"key":"pmbad9daebib35","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/S0360-3016(99)00007-3","article-title":"A model to accumulate fractionated dose in a deforming organ","volume":"44","author":"Yan","year":"1999","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbad9daebib36","doi-asserted-by":"publisher","first-page":"3499","DOI":"10.1088\/0031-9155\/57\/11\/3499","article-title":"A finite element method to correct deformable image registration errors in low-contrast regions","volume":"57","author":"Zhong","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbad9daebib37","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-018-21966-x","article-title":"Real-time energy\/mass transfer mapping for online 4D dose reconstruction","volume":"8","author":"Ziegenhein","year":"2018","journal-title":"Sci. Rep."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,24]],"date-time":"2024-12-24T12:17:05Z","timestamp":1735042625000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ad9dae"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,24]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12,24]]},"published-print":{"date-parts":[[2025,1,5]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ad9dae","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,24]]},"assertion":[{"value":"Quantifying the spatial distribution of the accumulated dose uncertainty using the novel delta index","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-08-16","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-12-11","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-12-24","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}