{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T11:40:54Z","timestamp":1793187654196,"version":"4.5.0"},"reference-count":175,"publisher":"IOP Publishing","issue":"10","license":[{"start":{"date-parts":[[2025,5,16]],"date-time":"2025-05-16T00:00:00Z","timestamp":1747353600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,5,16]],"date-time":"2025-05-16T00:00:00Z","timestamp":1747353600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"crossref","award":["R01CA272991"],"award-info":[{"award-number":["R01CA272991"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2025,5,18]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Photon-counting computed tomography (PCCT) marks a significant advancement over conventional Energy-integrating detector CT systems. This review highlights PCCT\u2019s superior spatial and contrast resolution, reduced radiation dose, and multi-energy imaging capabilities, which address key challenges in radiotherapy, such as accurate tumor delineation, precise dose calculation, and treatment response monitoring. PCCT\u2019s improved anatomical clarity enhances tumor targeting while minimizing damage to surrounding healthy tissues. Additionally, Metal artifact reduction and quantitative imaging capabilities optimize workflows, enabling ART and radiomics-driven personalized treatment. Emerging clinical applications in brachytherapy and radiopharmaceutical therapy show promising outcomes, although challenges like high costs and limited software integration remain. With advancements in artificial intelligence and dedicated radiotherapy packages, PCCT is poised to transform precision, safety, and efficacy in cancer radiotherapy, marking it as a pivotal technology for future clinical practice.<\/jats:p>","DOI":"10.1088\/1361-6560\/add4ba","type":"journal-article","created":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T18:53:28Z","timestamp":1746557608000},"page":"10TR01","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":22,"title":["Photon-counting CT in cancer radiotherapy: technological advances and clinical benefits"],"prefix":"10.1088","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0886-655X","authenticated-orcid":true,"given":"Keyur D","family":"Shah","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6078-9424","authenticated-orcid":true,"given":"Jun","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin","family":"Roper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anees","family":"Dhabaan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hania","family":"Al-Hallaq","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir","family":"Pourmorteza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9023-5855","authenticated-orcid":true,"given":"Xiaofeng","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,5,16]]},"reference":[{"key":"pmbadd4babib1","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1002\/jso.24761","article-title":"Dual energy CT\u2014a possible new method to assess regression of rectal cancers after neoadjuvant treatment","volume":"116","author":"Al-Najami","year":"2017","journal-title":"J. Surg. Oncol."},{"key":"pmbadd4babib2","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acc77e","article-title":"Micro-CT imaging of multiple K-edge elements using GaAs and CdTe photon counting detectors","volume":"68","author":"Allphin","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib3","doi-asserted-by":"publisher","first-page":"740","DOI":"10.3390\/tomography8020061","article-title":"Photon counting CT and radiomic analysis enables differentiation of tumors based on lymphocyte burden","volume":"8","author":"Allphin","year":"2022","journal-title":"Tomography"},{"key":"pmbadd4babib4","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1088\/0031-9155\/21\/5\/002","article-title":"Energy-selective reconstructions in x-ray computerised tomography","volume":"21","author":"Alvarez","year":"1976","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib5","article-title":"Deep PCCT: photon counting computed tomography deep learning applications review","author":"Alves","year":"2024"},{"key":"pmbadd4babib6","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1093\/jrr\/rrv100","article-title":"Prognostic impact of average iodine density assessed by dual-energy spectral imaging for predicting lung tumor recurrence after stereotactic body radiotherapy","volume":"57","author":"Aoki","year":"2016","journal-title":"J. Radiat. Res."},{"key":"pmbadd4babib7","doi-asserted-by":"publisher","first-page":"2971","DOI":"10.1007\/s00345-020-03082-6","article-title":"Substantial radiation dose reduction with consistent image quality using a novel low-dose stone composition protocol","volume":"38","author":"Apfaltrer","year":"2020","journal-title":"World J. Urol."},{"key":"pmbadd4babib8","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.zemedi.2017.05.001","article-title":"Feasibility of using single photon counting x-ray for lung tumor position estimation based on 4D-CT","volume":"27","author":"Aschenbrenner","year":"2017","journal-title":"Z. Med. Phys."},{"key":"pmbadd4babib9","doi-asserted-by":"publisher","first-page":"1294","DOI":"10.3390\/diagnostics12051294","article-title":"Comparison study of myocardial radiomics feature properties on energy-integrating and photon-counting detector CT","volume":"12","author":"Ayx","year":"2022","journal-title":"Diagnostics"},{"key":"pmbadd4babib10","doi-asserted-by":"publisher","first-page":"1220","DOI":"10.1117\/12.2548380.full","article-title":"Development of a benchtop photon counting cone-beam CT system with a translate-rotate geometry","volume":"11312","author":"Bader","year":"2020","journal-title":"Proc. SPIE"},{"key":"pmbadd4babib11","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1088\/0031-9155\/58\/5\/1433","article-title":"To bin or not to bin? The effect of CT system limiting resolution on noise and detectability","volume":"58","author":"Baek","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib12","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17440","article-title":"UNet\u2010based multi\u2010organ segmentation in photon counting CT using virtual monoenergetic images","volume":"54","author":"Baek","year":"2024","journal-title":"Med. Phys."},{"key":"pmbadd4babib13","doi-asserted-by":"publisher","first-page":"1926","DOI":"10.3390\/cancers16101926","article-title":"Update on renal cell carcinoma diagnosis with novel imaging approaches","volume":"16","author":"Bellin","year":"2024","journal-title":"Cancers"},{"key":"pmbadd4babib14","doi-asserted-by":"publisher","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","article-title":"Estimated risks of radiation-induced fatal cancer from pediatric CT","volume":"176","author":"Brenner","year":"2001","journal-title":"Am. J. Roentgenol."},{"key":"pmbadd4babib15","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1148\/radiol.12111170","article-title":"Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers","volume":"263","author":"Brook","year":"2012","journal-title":"Radiology"},{"key":"pmbadd4babib16","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac6ebc","article-title":"Dual-energy CT based mass density and relative stopping power estimation for proton therapy using physics-informed deep learning","volume":"67","author":"Chang","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib17","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1002\/mp.13950","article-title":"Automatic multi\u2010organ segmentation in dual\u2010energy CT (DECT) with dedicated 3D fully convolutional DECT networks","volume":"47","author":"Chen","year":"2020","journal-title":"Med. Phys."},{"key":"pmbadd4babib18","doi-asserted-by":"publisher","first-page":"6445","DOI":"10.1088\/0031-9155\/59\/21\/6445","article-title":"Spectral diffusion: an algorithm for robust material decomposition of spectral CT data","volume":"59","author":"Clark","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib19","doi-asserted-by":"publisher","first-page":"4600","DOI":"10.1007\/s00261-024-04503-5","article-title":"Photon counting CT clinical adoption, integration, and workflow","volume":"49","author":"Dane","year":"2024a","journal-title":"Abdom Radiol."},{"key":"pmbadd4babib20","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1097\/RCT.0000000000001562","article-title":"Photon-counting computed tomography versus energy-integrating dual-energy computed tomography: virtual noncontrast image quality comparison","volume":"48","author":"Dane","year":"2024b","journal-title":"J. Comput. Assist. Tomogr."},{"key":"pmbadd4babib21","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad7775","article-title":"Simultaneous iodine and barium imaging with photon-counting CT","volume":"69","author":"Deng","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib22","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1159\/000536065","article-title":"Photon counting computed tomography with the radiation dose of a chest x-ray: feasibility and diagnostic yield","volume":"103","author":"Dettmer","year":"2024","journal-title":"Respiration"},{"key":"pmbadd4babib23","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.223088","article-title":"Photon-counting versus dual-source CT of congenital heart defects in neonates and infants: initial experience","volume":"307","author":"Dirrichs","year":"2023","journal-title":"Radiology"},{"key":"pmbadd4babib24","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejro.2023.100538","article-title":"Photon-counting detector CT allows significant reduction in radiation dose while maintaining image quality and noise on non-contrast chest CT","volume":"11","author":"Donuru","year":"2023","journal-title":"Eur. J. Radiol. Open"},{"key":"pmbadd4babib25","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222432","article-title":"Clinical applications of photon-counting CT: a review of pioneer studies and a glimpse into the future","volume":"309","author":"Douek","year":"2023","journal-title":"Radiology"},{"key":"pmbadd4babib26","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab735e","article-title":"Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center","volume":"65","author":"Faller","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib27","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac0afd","article-title":"Iterative material decomposition for spectral CT using self-supervised Noise2Noise prior","volume":"66","author":"Fang","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib28","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1097\/RTI.0000000000000569","article-title":"Review of technical advancements and clinical applications of photon-counting computed tomography in imaging of the thorax","volume":"36","author":"Farhadi","year":"2021","journal-title":"J. Thoracic Imaging"},{"key":"pmbadd4babib29","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1111\/1754-9485.12926","article-title":"Tumour response in non-small-cell lung cancer patients treated with chemoradiotherapy\u2014Can spectral CT predict recurrence?","volume":"63","author":"Fehrenbach","year":"2019","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"pmbadd4babib30","doi-asserted-by":"publisher","first-page":"4484","DOI":"10.1007\/s00330-023-10499-1","article-title":"Potential radiation dose reduction in clinical photon-counting CT by the small pixel effect: ultra-high resolution (UHR) acquisitions reconstructed to standard resolution","volume":"34","author":"Fix Martinez","year":"2023","journal-title":"Eur. Radiol."},{"key":"pmbadd4babib31","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","article-title":"Photon-counting CT review","volume":"79","author":"Flohr","year":"2020a","journal-title":"Phys. Med."},{"key":"pmbadd4babib32","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20230407","article-title":"Cardiac imaging with photon counting CT","volume":"96","author":"Flohr","year":"2023","journal-title":"Br. J. Radiol."},{"key":"pmbadd4babib33","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s42058-020-00029-z","article-title":"Basic principles and clinical potential of photon-counting detector CT","volume":"3","author":"Flohr","year":"2020b","journal-title":"Chin. J. Acad Radiol."},{"key":"pmbadd4babib34","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad70ef","article-title":"A direct comparison of multi-energy x-ray and proton CT for imaging and relative stopping power estimation of plastic andex-vivophantoms","volume":"69","author":"Fogazzi","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib35","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1016\/j.actbio.2023.05.026","article-title":"Spectral computed tomography-guided radiotherapy of osteosarcoma utilizing BiOI nanosheets","volume":"166","author":"Fu","year":"2023","journal-title":"Acta Biomater."},{"key":"pmbadd4babib36","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad67a1","article-title":"CT-based synthetic contrast-enhanced dual-energy CT generation using conditional denoising diffusion probabilistic model","volume":"69","author":"Gao","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib37","doi-asserted-by":"publisher","first-page":"B64","DOI":"10.1111\/ijcp.12855","article-title":"Utility of dual-energy spectral CT and low-iodine contrast medium in DIEP angiography","volume":"70","author":"Gao","year":"2016","journal-title":"Int. J. Clin. Pract."},{"key":"pmbadd4babib38","doi-asserted-by":"publisher","first-page":"542","DOI":"10.3748\/wjg.v30.i6.542","article-title":"Preoperative prediction of lymphovascular and perineural invasion in gastric cancer using spectral computed tomography imaging and machine learning","volume":"30","author":"Ge","year":"2024","journal-title":"World J. Gastroenterol."},{"key":"pmbadd4babib39","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1148\/radiol.2015151169","article-title":"Radiomics: images are more than pictures, they are data","volume":"278","author":"Gillies","year":"2016","journal-title":"Radiology"},{"key":"pmbadd4babib40","doi-asserted-by":"publisher","first-page":"1787","DOI":"10.1016\/0360-3016(79)90562-5","article-title":"The value of ct scanning in radiation therapy treatment planning: a prospective study","volume":"5","author":"Goitein","year":"1979","journal-title":"Int. J. Radiat. Oncol.*Biol.*Phys."},{"key":"pmbadd4babib41","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1097\/RTI.0000000000000661","article-title":"Dose reduction and image quality in photon-counting detector high-resolution computed tomography of the chest: routine clinical data","volume":"37","author":"Graafen","year":"2022","journal-title":"J. Thoracic Imaging"},{"key":"pmbadd4babib42","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.diii.2024.09.002","article-title":"Photon-counting CT systems: a technical review of current clinical possibilities","volume":"106","author":"Greffier","year":"2024","journal-title":"Diagn. Intervent. Imaging"},{"key":"pmbadd4babib43","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1038\/s41584-019-0274-y","article-title":"Next-generation imaging of the skeletal system and its blood supply","volume":"15","author":"Gr\u00fcneboom","year":"2019","journal-title":"Nat. Rev. Rheumatol."},{"key":"pmbadd4babib44","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111448","article-title":"Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT","volume":"175","author":"Haag","year":"2024","journal-title":"Eur. J. Radiol."},{"key":"pmbadd4babib45","doi-asserted-by":"publisher","first-page":"467","DOI":"10.3390\/cancers16020467","article-title":"Enhancement of Stopping Power Ratio (SPR) estimation accuracy through image-domain dual-energy computer tomography for pencil beam scanning system: a simulation study","volume":"16","author":"Han","year":"2024","journal-title":"Cancers"},{"key":"pmbadd4babib46","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.8.5.052109","article-title":"Computed tomography recent history and future perspectives","volume":"8","author":"Hsieh","year":"2021","journal-title":"J. Med. Imaging"},{"key":"pmbadd4babib47","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.970299","article-title":"Assessment of quantitative information for radiation therapy at a first-generation clinical photon-counting computed tomography scanner","volume":"12","author":"Hu","year":"2022a","journal-title":"Front. Oncol."},{"key":"pmbadd4babib48","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.1007\/s00330-014-3257-z","article-title":"Spectral CT evaluation of interstitial brachytherapy in pancreatic carcinoma xenografts: preliminary animal experience","volume":"24","author":"Hu","year":"2014","journal-title":"Eur. Radiol."},{"key":"pmbadd4babib49","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac9176","article-title":"Small animal photon counting cone-beam CT on a preclinical radiation research platform to improve radiation dose calculation accuracy","volume":"67","author":"Hu","year":"2022b","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib50","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.acra.2024.08.013","article-title":"Advanced lung imaging with photon-counting detectors: insights from thermoluminescence dosimetry","volume":"32","author":"Huflage","year":"2024","journal-title":"Acad. Radiol."},{"key":"pmbadd4babib51","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1097\/RLI.0000000000000888","article-title":"Estimating the clinical impact of photon-counting-detector CT in diagnosing usual interstitial pneumonia","volume":"57","author":"Inoue","year":"2022","journal-title":"Invest. Radiol."},{"key":"pmbadd4babib52","doi-asserted-by":"publisher","first-page":"3752","DOI":"10.1002\/mp.14241","article-title":"Multi-energy computed tomography and material quantification: current barriers and opportunities for advancement","volume":"47","author":"Jacobsen","year":"2020","journal-title":"Med. Phys."},{"key":"pmbadd4babib53","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1109\/TBME.2019.2916907","article-title":"Noise suppression in image-domain multi-material decomposition for dual-energy CT","volume":"67","author":"Jiang","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmbadd4babib54","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1097\/RLI.0000000000000895","article-title":"Potential of photon-counting detector CT for radiation dose reduction for the assessment of interstitial lung disease in patients with systemic sclerosis","volume":"57","author":"Jungblut","year":"2022","journal-title":"Invest. Radiol."},{"key":"pmbadd4babib55","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1118\/1.1897083","article-title":"Presampling, algorithm factors, and noise: considerations for CT in particular and for medical imaging in general","volume":"32","author":"Kachelrie\u00df","year":"2005","journal-title":"Med. Phys."},{"key":"pmbadd4babib56","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20180850","article-title":"Determination of optimal virtual monochromatic energy level for target delineation of brain metastases in radiosurgery using dual-energy CT","volume":"93","author":"Karino","year":"2020","journal-title":"Br. J. Radiol."},{"key":"pmbadd4babib57","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/RLI.0000000000000616","article-title":"Effects of detector sampling on noise reduction in clinical photon-counting whole-body computed tomography","volume":"55","author":"Klein","year":"2020","journal-title":"Invest. Radiol."},{"key":"pmbadd4babib58","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1007\/s00247-006-0191-5","article-title":"Cancer risks following diagnostic and therapeutic radiation exposure in children","volume":"36","author":"Kleinerman","year":"2006","journal-title":"Pediatric Radiol."},{"key":"pmbadd4babib59","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1097\/RLI.0000000000000109","article-title":"The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency","volume":"50","author":"Krauss","year":"2015","journal-title":"Invest. Radiol."},{"key":"pmbadd4babib60","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13468","article-title":"Improving radiation physics, tumor visualisation, and treatment quantification in radiotherapy with spectral or dual-energy CT","volume":"23","author":"Kruis","year":"2022","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbadd4babib61","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.3390\/ijerph13111057","article-title":"Pediatric exposures to ionizing radiation: carcinogenic considerations","volume":"13","author":"Kutanzi","year":"2016","journal-title":"Int. J. Environ. Res. Public Health"},{"key":"pmbadd4babib62","doi-asserted-by":"publisher","first-page":"5293","DOI":"10.1002\/mp.12489","article-title":"A Bayesian approach to solve proton stopping powers from noisy multi-energy CT data","volume":"44","author":"Lalonde","year":"2017","journal-title":"Med. Phys."},{"key":"pmbadd4babib63","doi-asserted-by":"publisher","first-page":"6851","DOI":"10.1088\/0031-9155\/58\/19\/6851","article-title":"Deriving effective atomic numbers from DECT based on a parameterization of the ratio of high and low linear attenuation coefficients","volume":"58","author":"Landry","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib64","doi-asserted-by":"publisher","first-page":"5260","DOI":"10.1002\/mp.12475","article-title":"Assessing lung function using contrast-enhanced dual-energy computed tomography for potential applications in radiation therapy","volume":"44","author":"Lapointe","year":"2017","journal-title":"Med. Phys."},{"key":"pmbadd4babib65","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.11.S1.S12809","article-title":"Deep learning estimation of proton stopping power with photon-counting computed tomography: a virtual study","volume":"11","author":"Larsson","year":"2024","journal-title":"J. Med. Imaging"},{"key":"pmbadd4babib66","doi-asserted-by":"publisher","first-page":"8955","DOI":"10.1038\/s41598-023-35989-6","article-title":"Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT","volume":"13","author":"Layer","year":"2023","journal-title":"Sci. Rep."},{"key":"pmbadd4babib67","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1038\/nature14539","article-title":"Deep learning","volume":"521","author":"LeCun","year":"2015","journal-title":"Nature"},{"key":"pmbadd4babib68","doi-asserted-by":"publisher","first-page":"3619","DOI":"10.1002\/mp.17036","article-title":"PET\/SPECT\/Spectral-CT\/CBCT imaging in a small-animal radiation therapy platform: a Monte Carlo study-Part II: biologically guided radiotherapy","volume":"51","author":"Li","year":"2024a","journal-title":"Med. Phys."},{"key":"pmbadd4babib69","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.7.5.053501","article-title":"Overcoming calcium blooming and improving the quantification accuracy of percent area luminal stenosis by material decomposition of multi-energy computed tomography datasets","volume":"7","author":"Li","year":"2020","journal-title":"J. Med. Imaging"},{"key":"pmbadd4babib70","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1186\/s13014-024-02468-9","article-title":"Quantitative parameter analysis of pretreatment dual-energy computed tomography in nasopharyngeal carcinoma cervical lymph node characteristics and prediction of radiotherapy sensitivity","volume":"19","author":"Li","year":"2024b","journal-title":"Radiat. Oncol."},{"key":"pmbadd4babib71","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1016\/j.crad.2022.03.024","article-title":"A spectral CT-based nomogram for predicting the response to induction chemotherapy in nasopharyngeal carcinoma","volume":"77","author":"Liao","year":"2022","journal-title":"Clin. Radiol."},{"key":"pmbadd4babib72","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1111\/1754-9485.12504","article-title":"The value of spectral imaging to reduce artefacts in the body after (125) I seed implantation","volume":"60","author":"Liu","year":"2016","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"pmbadd4babib73","doi-asserted-by":"publisher","first-page":"1614","DOI":"10.1109\/TMI.2014.2320284","article-title":"Multi-material decomposition using statistical image reconstruction for spectral CT","volume":"33","author":"Long","year":"2014","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbadd4babib74","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13977","article-title":"Dual-energy CT-based stopping power prediction for dental materials in particle therapy","volume":"24","author":"Longarino","year":"2023","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbadd4babib75","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.853495","article-title":"Potential of a second-generation dual-layer spectral CT for dose calculation in particle therapy treatment planning","volume":"12","author":"Longarino","year":"2022a","journal-title":"Front. Oncol."},{"key":"pmbadd4babib76","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13465","article-title":"Dual-layer spectral CT for proton, helium, and carbon ion beam therapy planning of brain tumors","volume":"23","author":"Longarino","year":"2022b","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbadd4babib77","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1148\/radiol.2018180126","article-title":"Detection and characterization of renal stones by using photon-counting-based CT","volume":"289","author":"Marcus","year":"2018","journal-title":"Radiology"},{"key":"pmbadd4babib78","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1097\/HP.0000000000000997","article-title":"Computed tomography technology\u2014and dose\u2014in the 21st century","volume":"116","author":"McCollough","year":"2019","journal-title":"Health Phys."},{"key":"pmbadd4babib79","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1097\/RLI.0000000000000948","article-title":"Standardization and quantitative imaging with photon-counting detector CT","volume":"58","author":"McCollough","year":"2023","journal-title":"Invest. Radiol."},{"key":"pmbadd4babib80","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s41747-018-0051-8","article-title":"Dual-layer spectral computed tomography: measuring relative electron density","volume":"2","author":"Mei","year":"2018","journal-title":"Eur. Radiol. Exp."},{"key":"pmbadd4babib81","doi-asserted-by":"publisher","first-page":"698","DOI":"10.21037\/cdt-24-52","article-title":"Technical principles, benefits, challenges, and applications of photon counting computed tomography in coronary imaging: a narrative review","volume":"14","author":"Meloni","year":"2024","journal-title":"Cardiovascular Diagn. Ther."},{"key":"pmbadd4babib82","doi-asserted-by":"publisher","first-page":"645","DOI":"10.3390\/diagnostics13040645","article-title":"Photon-counting computed tomography (PCCT): technical background and cardio-vascular applications","volume":"13","author":"Meloni","year":"2023","journal-title":"Diagnostics"},{"key":"pmbadd4babib83","doi-asserted-by":"publisher","first-page":"828","DOI":"10.1093\/jrr\/rrac051","article-title":"Prediction of proton beam range in phantom with metals based on monochromatic energy CT images","volume":"63","author":"Meng","year":"2022","journal-title":"J. Radiat. Res."},{"key":"pmbadd4babib84","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1148\/radiol.213260","article-title":"Virtual noncontrast abdominal imaging with photon-counting detector CT","volume":"305","author":"Mergen","year":"2022","journal-title":"Radiology"},{"key":"pmbadd4babib85","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.240271","article-title":"Accuracy of ultralow-dose photon-counting CT in the detection of lung changes after lung transplant","volume":"312","author":"Milos","year":"2024","journal-title":"Radiology"},{"key":"pmbadd4babib86","doi-asserted-by":"publisher","first-page":"2429","DOI":"10.1002\/mp.12265","article-title":"Methodological accuracy of image-based electron density assessment using dual-energy computed tomography","volume":"44","author":"M\u00f6hler","year":"2017","journal-title":"Med. Phys."},{"key":"pmbadd4babib87","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac7d34","article-title":"Material decomposition from photon-counting CT using a convolutional neural network and energy-integrating CT training labels","volume":"67","author":"Nadkarni","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib88","doi-asserted-by":"publisher","first-page":"5232","DOI":"10.1002\/mp.15066","article-title":"Proton stopping power prediction based on dual-energy CT-generated virtual monoenergetic images","volume":"48","author":"N\u00e4smark","year":"2021","journal-title":"Med. Phys."},{"key":"pmbadd4babib89","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1136\/neurintsurg-2020-016953","article-title":"Utilizing dual energy CT to distinguish blood from contrast leakage following middle meningeal artery embolization for chronic subdural hematomas","volume":"13","author":"Naveed","year":"2021","journal-title":"J. Neurointervent. Surg."},{"key":"pmbadd4babib90","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.1016\/j.jcmg.2018.11.037","article-title":"The future of cardiovascular computed tomography: advanced analytics and clinical insights","volume":"12","author":"Nicol","year":"2019","journal-title":"JACC Cardiovascular Imaging"},{"key":"pmbadd4babib91","doi-asserted-by":"publisher","DOI":"10.1118\/1.4866386","article-title":"Iterative image\u2010domain decomposition for dual\u2010energy CT","volume":"41","author":"Niu","year":"2014","journal-title":"Med. Phys."},{"key":"pmbadd4babib92","doi-asserted-by":"publisher","first-page":"e172","DOI":"10.1016\/j.ijrobp.2024.07.387","article-title":"Initial examination of commercial photon counting CT for prostate planning","volume":"120","author":"O\u2019Connell","year":"2024","journal-title":"Int. J. Radiat. Oncol.*Biol.*Phys."},{"key":"pmbadd4babib93","doi-asserted-by":"publisher","first-page":"4383","DOI":"10.1007\/s00261-024-04414-5","article-title":"Photon-counting CT: technical features and clinical impact on abdominal imaging","volume":"49","author":"Onishi","year":"2024","journal-title":"Abdom Radiol."},{"key":"pmbadd4babib94","doi-asserted-by":"publisher","first-page":"5556","DOI":"10.1038\/s41598-021-84800-x","article-title":"Quantitative dual contrast photon-counting computed tomography for assessment of articular cartilage health","volume":"11","author":"Paakkari","year":"2021","journal-title":"Sci. Rep."},{"key":"pmbadd4babib95","doi-asserted-by":"publisher","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"pmbadd4babib96","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1186\/s12891-017-1420-9","article-title":"Utilization of CT scanning associated with complex spine surgery","volume":"18","author":"Patel","year":"2017","journal-title":"BMC Musculoskelet Disorders"},{"key":"pmbadd4babib97","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ejmp.2019.05.019","article-title":"Quality evaluation of monoenergetic images generated by dual-energy computed tomography for radiotherapy: a phantom study","volume":"63","author":"Pawa\u0142owski","year":"2019","journal-title":"Phys. Med."},{"key":"pmbadd4babib98","doi-asserted-by":"publisher","first-page":"6185","DOI":"10.1002\/mp.17255","article-title":"Image\u2010domain material decomposition for dual\u2010energy CT using unsupervised learning with data\u2010fidelity loss","volume":"51","author":"Peng","year":"2024","journal-title":"Med. Phys."},{"key":"pmbadd4babib99","first-page":"1","article-title":"The role of imaging in radiation therapy planning: past, present, and future","volume":"2014","author":"Pereira","year":"2014","journal-title":"Biomed. Res. Int."},{"key":"pmbadd4babib100","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.radonc.2021.11.002","article-title":"Reduction of clinical safety margins in proton therapy enabled by the clinical implementation of dual-energy CT for direct stopping-power prediction","volume":"166","author":"Peters","year":"2022","journal-title":"Radiother. Oncol."},{"key":"pmbadd4babib101","first-page":"4","article-title":"X-ray computed tomography for treatment planning: current status and innovations","author":"Peters","year":"2024"},{"key":"pmbadd4babib102","doi-asserted-by":"publisher","first-page":"4848","DOI":"10.1118\/1.4926780","article-title":"A general framework of noise suppression in material decomposition for dual\u2010energy CT","volume":"42","author":"Petrongolo","year":"2015","journal-title":"Med. Phys."},{"key":"pmbadd4babib103","doi-asserted-by":"publisher","first-page":"2286","DOI":"10.1109\/TMI.2015.2429000","article-title":"Noise suppression for dual-energy CT through entropy minimization","volume":"34","author":"Petrongolo","year":"2015","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbadd4babib104","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1148\/radiol.2020203896","article-title":"Photon-counting CT: scouting for quantitative imaging biomarkers","volume":"298","author":"Pourmorteza","year":"2021","journal-title":"Radiology"},{"key":"pmbadd4babib105","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/s41747-024-00530-5","article-title":"Beam hardening of K-edge contrast agents: a phantom study comparing clinical energy-integrating detector and photon-counting detector CT systems","volume":"9","author":"Pourmorteza","year":"2025","journal-title":"Eur. Radiol. Exp."},{"key":"pmbadd4babib106","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1097\/RLI.0000000000001060","article-title":"Photon-counting detector CT for liver lesion detection\u2014optimal virtual monoenergetic energy for different simulated patient sizes and radiation doses","volume":"59","author":"Racine","year":"2024","journal-title":"Invest. Radiol."},{"key":"pmbadd4babib107","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1016\/j.acra.2020.07.033","article-title":"Comparison of low dose performance of photon-counting and energy integrating CT","volume":"28","author":"Rajagopal","year":"2021","journal-title":"Acad. Radiol."},{"key":"pmbadd4babib108","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1148\/radiol.212579","article-title":"First clinical photon-counting detector CT system: technical evaluation","volume":"303","author":"Rajendran","year":"2022","journal-title":"Radiology"},{"key":"pmbadd4babib109","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1148\/rg.2020200038","article-title":"Update on multienergy CT: physics, principles, and applications","volume":"40","author":"Rajiah","year":"2020","journal-title":"Radiographics"},{"key":"pmbadd4babib110","doi-asserted-by":"publisher","first-page":"8034","DOI":"10.1002\/mp.17367","article-title":"Performance evaluation of single\u2010 and dual\u2010contrast spectral imaging on a photon\u2010counting\u2010detector CT","volume":"51","author":"Ren","year":"2024","journal-title":"Med. Phys."},{"key":"pmbadd4babib111","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1007\/978-3-030-96285-2_23","article-title":"Dual-energy CT in radiation oncology","author":"Richter","year":"2022"},{"key":"pmbadd4babib112","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1038\/sj.bjc.6601138","article-title":"Radiation dose, chemotherapy, hormonal treatment and risk of second cancer after breast cancer treatment","volume":"89","author":"Rubino","year":"2003","journal-title":"Br. J. Cancer"},{"key":"pmbadd4babib113","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1007\/s12194-018-00497-0","article-title":"Simulation of photon-counting detectors for conversion of dual-energy-subtracted computed tomography number to electron density","volume":"12","author":"Saito","year":"2019","journal-title":"Radiol. Phys. Technol."},{"key":"pmbadd4babib114","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1016\/j.zemedi.2022.01.005","article-title":"Quantification of the volume fraction of fat, water and bone mineral in spongiosa for red marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT\/)CT","volume":"32","author":"Salas-Ramirez","year":"2022","journal-title":"Z. Med. Phys."},{"key":"pmbadd4babib115","doi-asserted-by":"publisher","first-page":"539","DOI":"10.2214\/AJR.23.29463","article-title":"CT number accuracy and association with object size: a phantom study comparing energy-integrating detector CT and deep silicon photon-counting detector CT","volume":"221","author":"Salyapongse","year":"2023","journal-title":"Am. J. Roentgenol."},{"key":"pmbadd4babib116","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13900","article-title":"An evaluation of the use of DirectSPR images for proton planning in the RayStation treatment planning software","volume":"24","author":"Sarkar","year":"2023","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbadd4babib117","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20220544","article-title":"Photon-counting detector CT: early clinical experience review","volume":"96","author":"Sartoretti","year":"2023","journal-title":"Br. J. Radiol."},{"key":"pmbadd4babib118","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1055\/a-1902-9949","article-title":"Spectral CT in oncology","volume":"195","author":"Sauerbeck","year":"2023","journal-title":"RoFo"},{"key":"pmbadd4babib119","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.1002\/mp.17604","article-title":"CT material decomposition with contrast agents: single or multiple spectral photon\u2010counting CT scans? A simulation study","volume":"52","author":"Sawall","year":"2025","journal-title":"Med. Phys."},{"key":"pmbadd4babib120","doi-asserted-by":"publisher","first-page":"6631","DOI":"10.1007\/s00330-021-07786-0","article-title":"Threshold-dependent iodine imaging and spectral separation in a whole-body photon-counting CT system","volume":"31","author":"Sawall","year":"2021","journal-title":"Eur. Radiol."},{"key":"pmbadd4babib121","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1109\/TMI.2013.2250991","article-title":"Statistical reconstruction of material decomposed data in spectral CT","volume":"32","author":"Schirra","year":"2013","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbadd4babib122","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111276","article-title":"Advances in metal artifact reduction in CT images: a review of traditional and novel metal artifact reduction techniques","volume":"170","author":"Selles","year":"2024","journal-title":"Eur. J. Radiol."},{"key":"pmbadd4babib123","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2025.104945","article-title":"Accuracy and consistency of effective atomic number over object size using deep silicon photon-counting detector CT","volume":"131","author":"Shapiro","year":"2025","journal-title":"Phys. Med."},{"key":"pmbadd4babib124","doi-asserted-by":"publisher","first-page":"3325","DOI":"10.1111\/odi.14474","article-title":"Deep learning\u2010assisted diagnosis of parotid gland tumors by using contrast\u2010enhanced CT imaging","volume":"29","author":"Shen","year":"2023","journal-title":"Oral Dis."},{"key":"pmbadd4babib125","doi-asserted-by":"publisher","first-page":"5757","DOI":"10.3390\/jcm10245757","article-title":"Spectral photon-counting CT technology in chest imaging","volume":"10","author":"Si-Mohamed","year":"2021","journal-title":"J. Clin. Med."},{"key":"pmbadd4babib126","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1002\/mp.16363","article-title":"Report on the AAPM deep-learning spectral CT grand challenge","volume":"51","author":"Sidky","year":"2024","journal-title":"Med. Phys."},{"key":"pmbadd4babib127","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab1af1","article-title":"The potential of photon-counting CT for quantitative contrast-enhanced imaging in radiotherapy","volume":"64","author":"Simard","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib128","doi-asserted-by":"publisher","first-page":"3423","DOI":"10.1002\/mp.14204","article-title":"Quantitative imaging performance of MARS spectral photon-counting CT for radiotherapy","volume":"47","author":"Simard","year":"2020","journal-title":"Med. Phys."},{"key":"pmbadd4babib129","doi-asserted-by":"publisher","first-page":"2078","DOI":"10.1001\/archinternmed.2009.427","article-title":"Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer","volume":"169","author":"Smith-Bindman","year":"2009","journal-title":"Arch. Intern. Med."},{"key":"pmbadd4babib130","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-41854-3","article-title":"Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study","volume":"13","author":"Stein","year":"2023","journal-title":"Sci. Rep."},{"key":"pmbadd4babib131","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1007\/s11604-024-01537-z","article-title":"The value of preoperative diagnosis of colorectal adenocarcinoma pathological T staging based on dual-layer spectral-detector computed tomography extracellular volume fraction: a preliminary study","volume":"42","author":"Sun","year":"2024","journal-title":"Jpn. J. Radiol."},{"key":"pmbadd4babib132","doi-asserted-by":"publisher","first-page":"3620","DOI":"10.1016\/j.acra.2024.02.006","article-title":"Photon counting computed tomography in rectal cancer: associations between iodine concentration, histopathology and treatment response: a pilot study","volume":"31","author":"Surov","year":"2024","journal-title":"Acad. Radiol."},{"key":"pmbadd4babib133","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1148\/radiol.2017162587","article-title":"Feasibility of dose-reduced chest CT with photon-counting detectors: initial results in humans","volume":"285","author":"Symons","year":"2017c","journal-title":"Radiology"},{"key":"pmbadd4babib134","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1088\/1361-6560\/62\/1\/202","article-title":"Low-dose lung cancer screening with photon-counting CT: a feasibility study","volume":"62","author":"Symons","year":"2017a","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib135","doi-asserted-by":"publisher","first-page":"5120","DOI":"10.1002\/mp.12301","article-title":"Photon-counting CT for simultaneous imaging of multiple contrast agents in the abdomen: an in vivo study","volume":"44","author":"Symons","year":"2017b","journal-title":"Med. Phys."},{"key":"pmbadd4babib136","doi-asserted-by":"publisher","first-page":"5186","DOI":"10.1002\/mp.13173","article-title":"Theoretical and experimental analysis of photon counting detector CT for proton stopping power prediction","volume":"45","author":"Taasti","year":"2018","journal-title":"Med. Phys."},{"key":"pmbadd4babib137","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1007\/s13246-018-0653-8","article-title":"Simultaneous characterization of electron density and effective atomic number for radiotherapy planning using stoichiometric calibration method and dual energy algorithms","volume":"41","author":"Tahmasebi Birgani","year":"2018","journal-title":"Australas. Phys. Eng. Sci. Med."},{"key":"pmbadd4babib138","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.ejca.2023.02.017","article-title":"CT radiomics compared to a clinical model for predicting checkpoint inhibitor treatment outcomes in patients with advanced melanoma","volume":"185","author":"Ter Maat","year":"2023","journal-title":"Eur. J. Cancer"},{"key":"pmbadd4babib139","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1097\/RLI.0000000000000873","article-title":"Effective spatial resolution of photon counting CT for imaging of trabecular structures is superior to conventional clinical CT and similar to high resolution peripheral CT","volume":"57","author":"Thomsen","year":"2022","journal-title":"Invest. Radiol."},{"key":"pmbadd4babib140","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1117\/12.2293776","article-title":"A general CT reconstruction algorithm for model-based material decomposition","volume":"10573","author":"Tilley","year":"2018","journal-title":"Proc. SPIE"},{"key":"pmbadd4babib141","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2024.e29214","article-title":"A nomogram model of spectral CT quantitative parameters and clinical characteristics predicting lymphovascular invasion of gastric cancer","volume":"10","author":"Tong","year":"2024","journal-title":"Heliyon"},{"key":"pmbadd4babib142","doi-asserted-by":"publisher","first-page":"112","DOI":"10.3390\/jimaging8040112","article-title":"Spectral photon-counting computed tomography: a review on technical principles and clinical applications","volume":"8","author":"Tortora","year":"2022","journal-title":"J. Imaging"},{"key":"pmbadd4babib143","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.110829","article-title":"Photon-counting CT: review of initial clinical results","volume":"163","author":"van der Bie","year":"2023","journal-title":"Eur. J. Radiol."},{"key":"pmbadd4babib144","doi-asserted-by":"publisher","first-page":"6324","DOI":"10.1002\/mp.14886","article-title":"Silicon photomultiplier-based scintillation detectors for photon-counting CT: a feasibility study","volume":"48","author":"van der Sar","year":"2021","journal-title":"Med. Phys."},{"key":"pmbadd4babib145","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1007\/s00330-021-08152-w","article-title":"Coronary calcium scoring potential of large field-of-view spectral photon-counting CT: a phantom study","volume":"32","author":"Van Der Werf","year":"2022","journal-title":"Eur. Radiol."},{"key":"pmbadd4babib146","doi-asserted-by":"publisher","first-page":"2941","DOI":"10.1002\/mp.17007","article-title":"PET\/SPECT\/spectral-CT\/CBCT imaging in a small-animal radiation therapy platform: a Monte Carlo study\u2014Part I: quad-modal imaging","volume":"51","author":"Wang","year":"2024","journal-title":"Med. Phys."},{"key":"pmbadd4babib147","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1109\/TMI.2019.2932333","article-title":"An on-board spectral-CT\/CBCT\/SPECT imaging configuration for small-animal radiation therapy platform: a monte carlo study","volume":"39","author":"Wang","year":"2020","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbadd4babib148","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s42492-022-00129-w","article-title":"Photon-counting computed tomography thermometry via material decomposition and machine learning","volume":"6","author":"Wang","year":"2023","journal-title":"Vis. Comput. Ind. Biomed. Art"},{"key":"pmbadd4babib149","doi-asserted-by":"publisher","first-page":"46","DOI":"10.14338\/IJPT-D-20-00020.1","article-title":"Learning-based stopping power mapping on dual-energy CT for proton radiation therapy","volume":"7","author":"Wang","year":"2021a","journal-title":"Int. J. Part. Ther."},{"key":"pmbadd4babib150","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1002\/acm2.12539","article-title":"Optimal virtual monoenergetic image in \u201cTwinBeam\u201d dual\u2010energy CT for organs\u2010at\u2010risk delineation based on contrast\u2010noise\u2010ratio in head\u2010and\u2010neck radiotherapy","volume":"20","author":"Wang","year":"2019","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbadd4babib151","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abfce2","article-title":"Head and neck multi-organ segmentation on dual-energy CT using dual pyramid convolutional neural networks","volume":"66","author":"Wang","year":"2021b","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib152","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.zemedi.2022.06.002","article-title":"Ultrahigh resolution whole body photon counting computed tomography as a novel versatile tool for translational research from mouse to man","volume":"33","author":"Wehrse","year":"2023","journal-title":"Z. Med. Phys."},{"key":"pmbadd4babib153","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2016\/5871604","article-title":"Polychromatic iterative statistical material image reconstruction for photon-counting computed tomography","volume":"2016","author":"Weidinger","year":"2016","journal-title":"Int. J. Biomed. Imaging"},{"key":"pmbadd4babib154","doi-asserted-by":"publisher","first-page":"1990","DOI":"10.21037\/apm-21-3083","article-title":"Application value of double-layer spectral detector CT in differentiating central lung cancer from atelectasis","volume":"11","author":"Wen","year":"2022","journal-title":"Ann. Palliat Med."},{"key":"pmbadd4babib155","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon-counting CT: technical principles and clinical prospects","volume":"289","author":"Willemink","year":"2018","journal-title":"Radiology"},{"key":"pmbadd4babib156","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.3390\/diagnostics12061441","article-title":"Low-dose high-resolution photon-counting CT of the lung: radiation dose and image quality in the clinical routine","volume":"12","author":"Woeltjen","year":"2022","journal-title":"Diagnostics"},{"key":"pmbadd4babib157","doi-asserted-by":"publisher","first-page":"2362","DOI":"10.1016\/j.acra.2023.05.029","article-title":"Photon counting CT: technical principles, clinical applications, and future prospects","volume":"30","author":"Wu","year":"2023","journal-title":"Acad. Radiol."},{"key":"pmbadd4babib158","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaae91","article-title":"Ex vivo validation of a stoichiometric dual energy CT proton stopping power ratio calibration","volume":"63","author":"Xie","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib159","doi-asserted-by":"publisher","first-page":"708","DOI":"10.3390\/diagnostics12030708","article-title":"Assessment of liver fat: dual-energy CT versus conventional CT with and without contrast","volume":"12","author":"Xu","year":"2022","journal-title":"Diagnostics"},{"key":"pmbadd4babib160","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1186\/1748-717X-9-168","article-title":"Radiotherapy treatment planning with contrast-enhanced computed tomography: feasibility of dual-energy virtual unenhanced imaging for improved dose calculations","volume":"9","author":"Yamada","year":"2014","journal-title":"Radiat. Oncol."},{"key":"pmbadd4babib161","doi-asserted-by":"publisher","first-page":"9064","DOI":"10.1038\/s41598-018-27341-0","article-title":"Therapy effects of advanced hypopharyngeal and laryngeal squamous cell carcinoma: evaluated using dual-energy CT quantitative parameters","volume":"8","author":"Yang","year":"2018","journal-title":"Sci. Rep."},{"key":"pmbadd4babib162","doi-asserted-by":"publisher","first-page":"04TR01","DOI":"10.1088\/1361-6560\/acabfa","article-title":"Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential","volume":"68","author":"Yang","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib163","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1007\/s11604-015-0482-6","article-title":"Spectral CT with monochromatic imaging and metal artifacts reduction software for artifacts reduction of 125I radioactive seeds in liver brachytherapy","volume":"33","author":"Yang","year":"2015","journal-title":"Jpn. J. Radiol."},{"key":"pmbadd4babib164","doi-asserted-by":"publisher","first-page":"NP17","DOI":"10.1177\/1533034615595902","article-title":"Spectral imaging technology-based evaluation of radiation treatment planning to remove contrast agent artifacts","volume":"15","author":"Yi-Qun","year":"2016","journal-title":"Technol. Cancer Res. Treat."},{"key":"pmbadd4babib165","doi-asserted-by":"publisher","first-page":"S9","DOI":"10.2214\/AJR.12.9121","article-title":"Dual-energy CT\u2013based monochromatic imaging","volume":"199","author":"Yu","year":"2012","journal-title":"Am. J. Roentgenol."},{"key":"pmbadd4babib166","doi-asserted-by":"publisher","first-page":"6054","DOI":"10.1007\/s00330-023-09568-2","article-title":"Deep learning\u2013assisted diagnosis of benign and malignant parotid tumors based on contrast-enhanced CT: a multicenter study","volume":"33","author":"Yu","year":"2023","journal-title":"Eur. Radiol."},{"key":"pmbadd4babib167","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/tomography10010001","article-title":"Advantages of photon-counting detector CT in aortic imaging","volume":"10","author":"Zanon","year":"2023","journal-title":"Tomography"},{"key":"pmbadd4babib168","doi-asserted-by":"publisher","first-page":"1044","DOI":"10.1109\/TBME.2015.2476371","article-title":"Spectral CT image restoration via an average image-induced nonlocal means filter","volume":"63","author":"Zeng","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmbadd4babib169","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acebb3","article-title":"Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies","volume":"68","author":"Zhan","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbadd4babib170","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2024.106853","article-title":"A novel iterative iso-transmission line empirical material decomposition algorithm for multi-energy photon-counting CT","volume":"99","author":"Zhang","year":"2025","journal-title":"Biomed. Signal Process. Control"},{"key":"pmbadd4babib171","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1002\/mp.13489","article-title":"Image domain dual material decomposition for dual\u2010energy CT using butterfly network","volume":"46","author":"Zhang","year":"2019","journal-title":"Med. Phys."},{"key":"pmbadd4babib172","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1186\/s13244-023-01426-5","article-title":"Robustness of radiomics features of virtual unenhanced and virtual monoenergetic images in dual-energy CT among different imaging platforms and potential role of CT number variability","volume":"14","author":"Zhong","year":"2023","journal-title":"Insights Imaging"},{"key":"pmbadd4babib173","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14062","article-title":"Investigation on the proton range uncertainty with spectral CT-based virtual monoenergetic images","volume":"24","author":"Zhu","year":"2023","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbadd4babib174","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1016\/j.ijrobp.2024.11.069","article-title":"Assessment of photon-counting Computed Tomography for quantitative imaging in radiation therapy","volume":"121","author":"Zimmerman","year":"2024","journal-title":"Int. J. Radiat. Oncol.*Biol.*Phys."},{"key":"pmbadd4babib175","doi-asserted-by":"publisher","first-page":"1481","DOI":"10.1002\/mp.16063","article-title":"Stopping-power ratio estimation for proton radiotherapy using dual-energy computed tomography and prior-image constrained denoising","volume":"50","author":"Zimmerman","year":"2023","journal-title":"Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T05:49:31Z","timestamp":1747633771000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/add4ba"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,16]]},"references-count":175,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2025,5,16]]},"published-print":{"date-parts":[[2025,5,18]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/add4ba","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,16]]},"assertion":[{"value":"Photon-counting CT in cancer radiotherapy: technological advances and clinical benefits","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-10-30","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-05-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-05-16","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}