{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T13:30:35Z","timestamp":1788442235026,"version":"build-2803163510"},"reference-count":40,"publisher":"IOP Publishing","issue":"17","license":[{"start":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T00:00:00Z","timestamp":1756771200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T00:00:00Z","timestamp":1756771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"the Natural Science Foundation of Guangdong Province in China","award":["2023B1515120007"],"award-info":[{"award-number":["2023B1515120007"]}]},{"name":"Shenzhen Science and Technology Program","award":["JCYJ20220818101804009"],"award-info":[{"award-number":["JCYJ20220818101804009"]}]},{"name":"the Shenzhen Excellent Technological Innovation Talent Training Project of China","award":["RCJC20200714114436080"],"award-info":[{"award-number":["RCJC20200714114436080"]}]},{"name":"Shenzhen Medical Research Fund of China","award":["B2301002"],"award-info":[{"award-number":["B2301002"]}]},{"name":"the Shenzhen Science and Technology Program of China","award":["JCYJ20220818101804009"],"award-info":[{"award-number":["JCYJ20220818101804009"]}]},{"name":"the National Key Research and Development Program of China","award":["2024YFE0202400"],"award-info":[{"award-number":["2024YFE0202400"]}]},{"DOI":"10.13039\/501100001809","name":"the National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["12326607"],"award-info":[{"award-number":["12326607"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Shenzhen Outstanding Talents Training Fund"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2025,9,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    The lengthy 1 h dynamic positron emission tomography (PET) scans discomfort patients, add motion artifacts, and inflate costs, highlighting the need for tech advancements to reduce scan times. Therefore, we attempted to reconstruct multi-parametric imaging with only 20 min dynamic PET frames through deep learning techniques.\n                    <jats:italic>Approach.<\/jats:italic>\n                    Total-body PET data from 49 subjects (18 [\n                    <jats:sup>68<\/jats:sup>\n                    Ga]Ga-FAPI-04 and 31 [\n                    <jats:sup>68<\/jats:sup>\n                    Ga]Ga-prostate-specific membrane antigen (PSMA)-11) at Renji Hospital were used. We employed the dynamic PET frames prediction, parametric linear fitting and generative adversarial network to form the whole deep learning framework accomplishing reconstruction of multi-parametric images ([\n                    <jats:sup>68<\/jats:sup>\n                    Ga]Ga-FAPI-04:\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>K<\/mml:mi>\n                              <mml:mn>1<\/mml:mn>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    , DV and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>v<\/mml:mi>\n                              <mml:mrow>\n                                <mml:mtext>B<\/mml:mtext>\n                              <\/mml:mrow>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ; [\n                    <jats:sup>68<\/jats:sup>\n                    Ga]Ga-PSMA-11:\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>K<\/mml:mi>\n                              <mml:mn>1<\/mml:mn>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ,\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>K<\/mml:mi>\n                              <mml:mrow>\n                                <mml:mtext>i<\/mml:mtext>\n                              <\/mml:mrow>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>v<\/mml:mi>\n                              <mml:mrow>\n                                <mml:mtext>B<\/mml:mtext>\n                              <\/mml:mrow>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) from 20 min dynamic PET frames. The peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) were used to evaluate the quality of the synthesized results. Statistical analyses, including Pearson correlation coefficient (PCC) and violin plot, were also used for the reconstruction assessments.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The reconstructed multi-parametric images using the proposed technique closely resembled their full-time parametric counterparts, demonstrating high image quality across various tissue types. The reconstructed images resulting from the [\n                    <jats:sup>68<\/jats:sup>\n                    Ga]Ga-FAPI-04 and [\n                    <jats:sup>68<\/jats:sup>\n                    Ga]Ga-PSMA-11 tracers outperform 5 comparison methods, yielding average PSNR values of 35.5535 dB and 36.4040 dB, along with SSIM scores of 0.9798 and 0.9630, respectively. Additionally, the PCCs within the region of interests exhibited strong correlations (above 0.92) with the ground truth. Moreover, the imaging results in the pancreatic and prostate areas matched well with full-time parametric images.\n                    <jats:italic>Significance.<\/jats:italic>\n                    Our approach shortens the scan duration of dynamic PET from above one hour to 20 min, which greatly improves the experience for patients and reduces motion artifacts and costs.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/adfe33","type":"journal-article","created":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T22:54:10Z","timestamp":1755816850000},"page":"175019","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Reconstruction of total-body multi parametric images with shortened-duration dynamic [\n                    <sup>68<\/sup>\n                    Ga]Ga-PSMA-11 and [\n                    <sup>68<\/sup>\n                    Ga]Ga-FAPI-04 PET scans"],"prefix":"10.1088","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-4858-3545","authenticated-orcid":false,"given":"Yunlong","family":"Gao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9042-4477","authenticated-orcid":true,"given":"Zixiang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2872-599X","authenticated-orcid":false,"given":"Wenjie","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1642-6631","authenticated-orcid":true,"given":"Yongfeng","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8558-5102","authenticated-orcid":false,"given":"Hairong","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1358-9777","authenticated-orcid":true,"given":"Dong","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianjun","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruohua","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0618-6240","authenticated-orcid":true,"given":"Zhanli","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,9,2]]},"reference":[{"key":"pmbadfe33bib1","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1007\/s12149-024-01939-z","type":"journal-article","article-title":"Dual-time-point dynamic 68Ga-PSMA-11 PET\/CT for parametric imaging generation in prostate cancer","volume":"38","author":"Burasothikul","year":"2024","journal-title":"Ann. Nucl. Med."},{"key":"pmbadfe33bib2","doi-asserted-by":"publisher","first-page":"1820","DOI":"10.1007\/s00259-020-04769-z","type":"journal-article","article-title":"Comparison of [68Ga]Ga-DOTA-FAPI-04 and [18F] FDG PET\/CT for the diagnosis of primary and metastatic lesions in patients with various types of cancer","volume":"47","author":"Chen","year":"2020","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbadfe33bib3","doi-asserted-by":"publisher","first-page":"960","DOI":"10.2967\/jnumed.122.264988","type":"journal-article","article-title":"First total-body kinetic modeling and parametric imaging of dynamic 68Ga-FAPI-04 PET in pancreatic and gastric cancer","volume":"64","author":"Chen","year":"2023","journal-title":"J. Nucl. Med."},{"key":"pmbadfe33bib4","doi-asserted-by":"publisher","first-page":"2121","DOI":"10.1002\/mp.15893","type":"journal-article","article-title":"Accurate total-body Ki parametric imaging with shortened dynamic 18F-FDG PET scan durations via effective data processing","volume":"50","author":"Chen","year":"2023","journal-title":"Med. Phys."},{"key":"pmbadfe33bib5","doi-asserted-by":"publisher","first-page":"3689","DOI":"10.1109\/TBME.2022.3176097","type":"journal-article","article-title":"High temporal resolution total-body dynamic PET imaging based on pixel-level time-activity curve correction","volume":"69","author":"Chen","year":"2022","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmbadfe33bib6","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2022.102519","type":"journal-article","article-title":"Unsupervised PET logan parametric image estimation using conditional deep image prior","volume":"80","author":"Cui","year":"2022","journal-title":"Med. Image Anal."},{"key":"pmbadfe33bib7","doi-asserted-by":"publisher","first-page":"2780","DOI":"10.1007\/s00259-019-04468-4","type":"journal-article","article-title":"PET image denoising using unsupervised deep learning","volume":"46","author":"Cui","year":"2019","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbadfe33bib8","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/s00259-020-04843-6","type":"journal-article","article-title":"Kinetic modeling and parametric imaging with dynamic PET for oncological applications: general considerations, current clinical applications, and future perspectives","volume":"48","author":"Dimitrakopoulou-Strauss","year":"2021","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbadfe33bib9","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1053\/j.semnuclmed.2021.10.002","type":"journal-article","article-title":"Parametric imaging with dynamic PET for oncological applications: protocols, interpretation, current applications and limitations for clinical use","volume":"52","author":"Dimitrakopoulou-Strauss","year":"2022","journal-title":"Semin. Nucl. Med."},{"key":"pmbadfe33bib10","doi-asserted-by":"publisher","first-page":"2842","DOI":"10.1109\/TMI.2023.3266455","type":"journal-article","article-title":"A shortened model for logan reference plot implemented via the self-supervised neural network for parametric PET imaging","volume":"42","author":"Ding","year":"2023","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbadfe33bib11","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1109\/TMI.2021.3112783","type":"journal-article","article-title":"Machine learning-based noninvasive quantification of single-imaging session dual-tracer 18F-FDG and 68Ga-DOTATATE dynamic PET-CT in oncology","volume":"41","author":"Ding","year":"2022","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbadfe33bib12","doi-asserted-by":"publisher","first-page":"4812","DOI":"10.1007\/s00330-018-5966-1","type":"journal-article","article-title":"Does whole-body Patlak 18F-FDG PET imaging improve lesion detectability in clinical oncology?","volume":"29","author":"Fahrni","year":"2019","journal-title":"Eur. Radiol."},{"key":"pmbadfe33bib13","doi-asserted-by":"publisher","first-page":"3433","DOI":"10.1002\/cncr.28860","type":"journal-article","article-title":"PET\/CT imaging in cancer: current applications and future directions","volume":"120","author":"Farwell","year":"2014","journal-title":"Cancer"},{"key":"pmbadfe33bib14","doi-asserted-by":"publisher","first-page":"386","DOI":"10.2967\/jnumed.118.215913","type":"journal-article","article-title":"68Ga-FAPI PET\/CT: biodistribution and preliminary dosimetry estimate of 2 DOTA-containing FAP-targeting agents in patients with various cancers","volume":"60","author":"Frederik","year":"2019","journal-title":"J. Nucl. Med."},{"key":"pmbadfe33bib15","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1109\/TMI.2018.2888491","type":"journal-article","article-title":"PET image reconstruction using deep image prior","volume":"38","author":"Gong","year":"2019a","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbadfe33bib16","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1109\/TMI.2018.2869871","type":"journal-article","article-title":"Iterative PET image reconstruction using convolutional neural network representation","volume":"38","author":"Gong","year":"2019b","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbadfe33bib17","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1007\/s00259-020-05061-w","type":"journal-article","article-title":"Attenuation correction using deep learning and integrated UTE\/multi-echo Dixon sequence: evaluation in amyloid and tau PET imaging","volume":"48","author":"Gong","year":"2021","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbadfe33bib18","first-page":"2672","type":"conference-proceedings","article-title":"Generative adversarial nets","volume":"vol 2","author":"Goodfellow","year":"2014"},{"key":"pmbadfe33bib19","doi-asserted-by":"publisher","first-page":"1292","DOI":"10.1007\/s12350-018-1201-3","type":"journal-article","article-title":"Dynamic cardiac PET imaging: technological improvements advancing future cardiac health","volume":"26","author":"Gullberg","year":"2019","journal-title":"J. Nucl. Cardiol."},{"key":"pmbadfe33bib20","doi-asserted-by":"publisher","first-page":"713","DOI":"10.3390\/ph14080713","type":"journal-article","article-title":"[68Ga]Ga-PSMA-11: the first FDA-approved 68Ga-Radiopharmaceutical for PET imaging of prostate cancer","volume":"14","author":"Hennrich","year":"2021","journal-title":"Pharmaceuticals"},{"key":"pmbadfe33bib21","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abc5cc","type":"journal-article","article-title":"DaNet: dose-aware network embedded with dose-level estimation for low-dose CT imaging","volume":"66","author":"Huang","year":"2021a","journal-title":"Phys. Med. Biol."},{"key":"pmbadfe33bib22","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.neucom.2020.10.077","type":"journal-article","article-title":"Considering anatomical prior information for low-dose CT image enhancement using attribute-augmented Wasserstein generative adversarial networks","volume":"428","author":"Huang","year":"2021b","journal-title":"Neurocomputing"},{"key":"pmbadfe33bib23","doi-asserted-by":"publisher","first-page":"3416","DOI":"10.1109\/JBHI.2021.3061758","type":"journal-article","article-title":"Learning a deep CNN denoising approach using anatomical prior information implemented with attention mechanism for low-dose CT imaging on clinical patient data from multiple anatomical sites","volume":"25","author":"Huang","year":"2021c","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"pmbadfe33bib24","doi-asserted-by":"publisher","first-page":"2482","DOI":"10.1007\/s00259-022-05731-x","type":"journal-article","article-title":"Parametric image generation with the uEXPLORER total-body PET\/CT system through deep learning","volume":"49","author":"Huang","year":"2022","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbadfe33bib25","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1038\/jcbfm.1991.130","type":"journal-article","article-title":"Compartmental analysis of [11C]Flumazenil kinetics for the estimation of ligand transport rate and receptor distribution using positron emission tomography","volume":"11","author":"Koeppe","year":"1991","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"pmbadfe33bib26","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1186\/s40658-023-00579-y","type":"journal-article","article-title":"Combining deep learning with a kinetic model to predict dynamic PET images and generate parametric images","volume":"10","author":"Liang","year":"2023","journal-title":"EJNMMI Phys."},{"key":"pmbadfe33bib27","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ac086c","type":"journal-article","article-title":"Direct and indirect parameter imaging methods for dynamic PET","volume":"7","author":"Mao","year":"2021","journal-title":"Biomed. Phys. Eng. Express"},{"key":"pmbadfe33bib28","doi-asserted-by":"publisher","first-page":"783","DOI":"10.2967\/jnumed.106.032789","type":"journal-article","article-title":"Clinical myocardial perfusion PET\/CT","volume":"48","author":"Marcelo","year":"2007","journal-title":"J. Nucl. Med."},{"key":"pmbadfe33bib29","first-page":"6309","type":"conference-proceedings","article-title":"Neural discrete representation learning","author":"Oord","year":"2017"},{"key":"pmbadfe33bib30","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.dld.2021.07.011","type":"journal-article","article-title":"FAPI PET\/CT research progress in digestive system tumours","volume":"54","author":"Peng","year":"2022","journal-title":"Digestive Liver Dis."},{"key":"pmbadfe33bib31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TRPMS.2020.3014786","type":"journal-article","article-title":"Deep learning for PET image reconstruction","volume":"5","author":"Reader","year":"2021","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbadfe33bib32","doi-asserted-by":"publisher","first-page":"2405","DOI":"10.1007\/s00259-020-05167-1","type":"journal-article","article-title":"Deep learning-assisted ultra-fast\/low-dose whole-body PET\/CT imaging","volume":"48","author":"Sanaat","year":"2021","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbadfe33bib33","doi-asserted-by":"publisher","first-page":"2383","DOI":"10.1007\/s00259-020-04746-6","type":"journal-article","article-title":"Deep learning-based attenuation map generation for myocardial perfusion SPECT","volume":"47","author":"Shi","year":"2020","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbadfe33bib34","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1109\/TRPMS.2020.3025086","type":"journal-article","article-title":"PET parametric imaging: past, present, and future","volume":"4","author":"Wang","year":"2020","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbadfe33bib35","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2021.693640","type":"journal-article","article-title":"68Ga-FAPI-04 versus 18F-FDG PET\/CT in the detection of hepatocellular carcinoma","volume":"11","author":"Wang","year":"2021","journal-title":"Front. Oncol."},{"key":"pmbadfe33bib36","doi-asserted-by":"publisher","first-page":"2676","DOI":"10.1007\/s00330-022-09237-w","type":"journal-article","article-title":"Deep learning\u2013based dynamic PET parametric Ki image generation from lung static PET","volume":"33","author":"Wang","year":"2023","journal-title":"Eur. Radiol."},{"key":"pmbadfe33bib37","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1007\/BF02984655","type":"journal-article","article-title":"PET kinetic analysis\u2014compartmental model","volume":"20","author":"Watabe","year":"2006","journal-title":"Ann. Nucl. Med."},{"key":"pmbadfe33bib38","doi-asserted-by":"publisher","first-page":"622","DOI":"10.2967\/jnumed.120.261651","type":"journal-article","article-title":"Whole-body parametric imaging of 18F-FDG PET using uEXPLORER with reduced scanning time","volume":"63","author":"Wu","year":"2022","journal-title":"J. Nucl. Med."},{"key":"pmbadfe33bib39","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1186\/s40658-024-00698-0","type":"journal-article","article-title":"Bidirectional dynamic frame prediction network for total-body [68Ga] Ga-PSMA-11 and [68Ga] Ga-FAPI-04 PET images","volume":"11","author":"Yang","year":"2024","journal-title":"EJNMMI Phys."},{"key":"pmbadfe33bib40","doi-asserted-by":"publisher","first-page":"285","DOI":"10.2967\/jnumed.119.230565","type":"journal-article","article-title":"Total-body dynamic reconstruction and parametric imaging on the uEXPLORER","volume":"61","author":"Zhang","year":"2019","journal-title":"J. Nucl. Med."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T15:13:38Z","timestamp":1770909218000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/adfe33"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,2]]},"references-count":40,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2025,9,2]]},"published-print":{"date-parts":[[2025,9,7]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/adfe33","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,2]]},"assertion":[{"value":"Reconstruction of total-body multi parametric images with shortened-duration dynamic [\n                      68\n                      Ga]Ga-PSMA-11 and [\n                      68\n                      Ga]Ga-FAPI-04 PET scans","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-02-10","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-08-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-09-02","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}