{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T05:18:23Z","timestamp":1790572703918,"version":"4.1.0"},"reference-count":78,"publisher":"IOP Publishing","issue":"19","license":[{"start":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T00:00:00Z","timestamp":1759190400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T00:00:00Z","timestamp":1759190400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"National Cancer Institute","award":["R01-CA266803"],"award-info":[{"award-number":["R01-CA266803"]}]},{"DOI":"10.13039\/100005294","name":"Massachusetts General Hospital","doi-asserted-by":"crossref","award":["C06-CA059267"],"award-info":[{"award-number":["C06-CA059267"]}],"id":[{"id":"10.13039\/100005294","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Asan Foundation Biomedical Science Scholarship Program"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2025,10,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> Efficient image guidance and online adaptive treatment are essential for the success of gantry-less proton therapy (PT). Low-field magnetic resonance imaging (MRI) is a viable option for image guidance, but scan time can limit the quality of low-field MRI images. This study aims to investigate the impact of MRI image quality on deformable image registration (DIR) performance. <jats:italic>Approach.<\/jats:italic> We propose a Chebyshev-polynomial-based DIR method, which calculates a mapping between the voxels of a high-quality source image and a lower-quality target image. We prepared a longitudinal breast MRI dataset and synthesized lower-quality target images with four image resolutions and noise levels. For evaluation, we assumed the registration between a pair of high-quality images as the reference registration. We calculated the root-mean-square error (RMSE) between the warped image and the reference target image, as well as between the warped images aligned with high- and lower-quality target images. Deformable vector field (DVF) errors were calculated based on the reference DVF. We obtained binary masks for glandular tissue and calculated Dice coefficients after DIR. The method was further validated with a volunteer breast MRI study with intentional movements between two scan sets and a longitudinal pelvic MRI dataset that includes two contours. Comparison studies with commercial software and open-source software were performed. <jats:italic>Main results.<\/jats:italic> Although the quantitative metrics worsened with higher levels of undersampling or increased noise, the RMSE between the warped and target images was substantially reduced compared to the RMSE between the source and target images before registration, even when the target images were severely degraded. Dice coefficients were also considerably increased under various image degradation scenarios. <jats:italic>Significance.<\/jats:italic> We have developed a Chebyshev-polynomial-based DIR method and demonstrated its performance with high-quality source and lower-quality target images. This study could help optimize MRI for adaptive gantry-less PT.<\/jats:p>","DOI":"10.1088\/1361-6560\/ae077e","type":"journal-article","created":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T22:52:03Z","timestamp":1758063123000},"page":"195014","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Chebyshev-polynomial-based deformable registration of magnetic resonance images with a specific application in adaptive gantry-less proton therapy"],"prefix":"10.1088","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5666-0129","authenticated-orcid":true,"given":"Hyeongseok","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samantha","family":"Hickey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1516-537X","authenticated-orcid":true,"given":"Gregory","family":"Buti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1700-7519","authenticated-orcid":true,"given":"Ali","family":"Ajdari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory C","family":"Sharp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susu","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Bortfeld","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,9,30]]},"reference":[{"key":"pmbae077ebib1","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1038\/nrc.2016.18","type":"journal-article","article-title":"Radiation oncology in the era of precision medicine","volume":"16","author":"Baumann","year":"2016","journal-title":"Nat. Rev. Cancer"},{"key":"pmbae077ebib2","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1002\/jmri.27324","type":"journal-article","article-title":"Low-field MRI of stroke: challenges and opportunities","volume":"54","author":"Bhat","year":"2021","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmbae077ebib3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ctro.2023.100625","type":"journal-article","article-title":"Large anatomical changes in head-and-neck cancers\u2013a dosimetric comparison of online and offline adaptive proton therapy","volume":"40","author":"Bobi\u0107","year":"2023","journal-title":"Clin. Transl. Radiat. Oncol."},{"key":"pmbae077ebib4","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2023.1250678","type":"journal-article","article-title":"Upright patient positioning for gantry-free breast radiotherapy: feasibility tests using a robotic chair and specialised bras","volume":"13","author":"Boisbouvier","year":"2023","journal-title":"Front. Oncol."},{"key":"pmbae077ebib5","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1038\/549451a","type":"journal-article","article-title":"Three ways to make proton therapy affordable","volume":"549","author":"Bortfeld","year":"2017","journal-title":"Nature"},{"key":"pmbae077ebib6","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1088\/0031-9155\/55\/1\/006","type":"journal-article","article-title":"The number of beams in IMRT-theoretical investigations and implications for single-arc IMRT","volume":"55","author":"Bortfeld","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib7","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1088\/0031-9155\/44\/4\/020","type":"journal-article","article-title":"Fast and exact 2d image reconstruction by means of Chebyshev decomposition and backprojection","volume":"44","author":"Bortfeld","year":"1999","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib8","doi-asserted-by":"publisher","first-page":"1388","DOI":"10.1002\/jmri.25874","type":"journal-article","article-title":"Tumor radiomic heterogeneity: multiparametric functional imaging to characterize variability and predict response following cervical cancer radiation therapy","volume":"47","author":"Bowen","year":"2018","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmbae077ebib9","author":"Boyd","year":"2001","type":"book"},{"key":"pmbae077ebib10","first-page":"pp 981","type":"conference-proceedings","article-title":"A soft robotic device for patient immobilization in sitting and reclined positions for a compact proton therapy system","author":"Buchner","year":"2020"},{"key":"pmbae077ebib11","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1148\/radiol.2019190452","type":"journal-article","article-title":"Opportunities in interventional and diagnostic imaging by using high-performance low-field-strength MRI","volume":"293","author":"Campbell-Washburn","year":"2019","journal-title":"Radiology"},{"key":"pmbae077ebib12","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1137\/17M1134627","type":"journal-article","article-title":"Indirect image registration with large diffeomorphic deformations","volume":"11","author":"Chen","year":"2018","journal-title":"SIAM J. Imaging Sci."},{"key":"pmbae077ebib13","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1109\/42.932742","type":"journal-article","article-title":"Consistent image registration","volume":"20","author":"Christensen","year":"2001","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae077ebib14","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1080\/0284186X.2021.1891282","type":"journal-article","article-title":"Accuracy of automatic structure propagation for daily magnetic resonance image-guided head and neck radiotherapy","volume":"60","author":"Christiansen","year":"2021","journal-title":"Acta Oncol."},{"key":"pmbae077ebib15","doi-asserted-by":"publisher","first-page":"1045","DOI":"10.1007\/s10278-013-9622-7","type":"journal-article","article-title":"The cancer imaging archive (TCIA): maintaining and operating a public information repository","volume":"26","author":"Clark","year":"2013","journal-title":"J. Digital Imaging"},{"key":"pmbae077ebib16","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2020.101941","type":"journal-article","article-title":"Variational multi-task MRI reconstruction: joint reconstruction, registration and super-resolution","volume":"68","author":"Corona","year":"2021","journal-title":"Med. Image Anal."},{"key":"pmbae077ebib17","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1148\/radiology.153.1.6089263","type":"journal-article","article-title":"Simple proton spectroscopic imaging","volume":"153","author":"Dixon","year":"1984","journal-title":"Radiology"},{"key":"pmbae077ebib18","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acd518","type":"journal-article","article-title":"A motion model-guided 4d dose reconstruction for pencil beam scanned proton therapy","volume":"68","author":"Duetschler","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib19","doi-asserted-by":"publisher","first-page":"1084","DOI":"10.1137\/15M1047325","type":"journal-article","article-title":"Multicontrast MRI reconstruction with structure-guided total variation","volume":"9","author":"Ehrhardt","year":"2016","journal-title":"SIAM J. Imaging Sci."},{"key":"pmbae077ebib20","doi-asserted-by":"publisher","first-page":"966","DOI":"10.1002\/jmri.25547","type":"journal-article","article-title":"Compressed sensing for body MRI","volume":"45","author":"Feng","year":"2017","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmbae077ebib21","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abb16f","type":"journal-article","article-title":"Characterization of magnetic interference and image artefacts during simultaneous in-beam MR imaging and proton pencil beam scanning","volume":"65","author":"Gantz","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib22","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1109\/TRPMS.2021.3085991","type":"journal-article","article-title":"Image performance characterization of an in-beam low-field magnetic resonance imaging system during static proton beam irradiation","volume":"6","author":"Gantz","year":"2021","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbae077ebib23","article-title":"Scan-adaptive MRI undersampling using neighbor-based optimization (suno)","author":"Gautam","year":"2025","type":"preprint"},{"key":"pmbae077ebib24","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1109\/TMI.2010.2085084","type":"journal-article","article-title":"Compressed-sensing MRI with random encoding","volume":"30","author":"Haldar","year":"2010","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae077ebib25","doi-asserted-by":"publisher","first-page":"1670","DOI":"10.1093\/imanum\/drv060","type":"journal-article","article-title":"A fast FFT-based discrete legendre transform","volume":"36","author":"Hale","year":"2016","journal-title":"IMA J. Numer. Anal."},{"key":"pmbae077ebib26","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.pnmrs.2017.04.002","type":"journal-article","article-title":"Recent advances in parallel imaging for MRI","volume":"101","author":"Hamilton","year":"2017","journal-title":"Prog. Nucl. Magn. Reson. Spectrosc."},{"key":"pmbae077ebib27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13014-020-01571-x","type":"journal-article","article-title":"MR-guided proton therapy: a review and a preview","volume":"15","author":"Hoffmann","year":"2020","journal-title":"Radiat. Oncol."},{"key":"pmbae077ebib28","doi-asserted-by":"publisher","first-page":"1750","DOI":"10.1109\/TBME.2024.3520895","type":"journal-article","article-title":"Breast coil optimization for low field MRI and future MR-guided proton therapy","volume":"72","author":"Hornung","year":"2024","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmbae077ebib29","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1593\/tlo.13838","type":"journal-article","article-title":"Variations of dynamic contrast-enhanced magnetic resonance imaging in evaluation of breast cancer therapy response: a multicenter data analysis challenge","volume":"7","author":"Huang","year":"2014","journal-title":"Transl. Oncol."},{"key":"pmbae077ebib30","article-title":"Synthetic low-field MRI super-resolution via nested u-net architecture","author":"Kalluvila","year":"2022","type":"preprint"},{"key":"pmbae077ebib31","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1038\/s41571-022-00631-3","type":"journal-article","article-title":"Integrated MRI-guided radiotherapy-opportunities and challenges","volume":"19","author":"Keall","year":"2022","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"pmbae077ebib32","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1109\/TMI.2009.2035616","type":"journal-article","article-title":"Elastix: a toolbox for intensity-based medical image registration","volume":"29","author":"Klein","year":"2009","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae077ebib33","doi-asserted-by":"publisher","first-page":"8248","DOI":"10.1038\/s41598-021-87482-7","type":"journal-article","article-title":"Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction","volume":"11","author":"Koonjoo","year":"2021","journal-title":"Sci. Rep."},{"key":"pmbae077ebib34","doi-asserted-by":"publisher","first-page":"2447","DOI":"10.1109\/TMI.2016.2577642","type":"journal-article","article-title":"MR image reconstruction using a combination of compressed sensing and partial Fourier acquisition: Espresso","volume":"35","author":"K\u00fcstner","year":"2016","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae077ebib35","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acd433","type":"journal-article","article-title":"Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy","volume":"68","author":"Lalonde","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib36","doi-asserted-by":"publisher","first-page":"R15","DOI":"10.1088\/0031-9155\/52\/7\/R01","type":"journal-article","article-title":"Parallel magnetic resonance imaging","volume":"52","author":"Larkman","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib37","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2020.101930","type":"journal-article","article-title":"Rethinking medical image reconstruction via shape prior, going deeper and faster: deep joint indirect registration and reconstruction","volume":"68","author":"Liu","year":"2021","journal-title":"Med. Image Anal."},{"key":"pmbae077ebib38","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1109\/MSP.2007.914728","type":"journal-article","article-title":"Compressed sensing MRI","volume":"25","author":"Lustig","year":"2008","journal-title":"IEEE Signal Process. Mag."},{"key":"pmbae077ebib39","doi-asserted-by":"publisher","DOI":"10.1063\/5.0051770","type":"journal-article","article-title":"Is upright radiotherapy medically and financially better?","volume":"2348","author":"Mackie","year":"2021","journal-title":"AIP Conf. Proc."},{"key":"pmbae077ebib40","doi-asserted-by":"publisher","first-page":"1528","DOI":"10.1002\/jmri.26637","type":"journal-article","article-title":"Low-field MRI: an MR physics perspective","volume":"49","author":"Marques","year":"2019","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmbae077ebib41","doi-asserted-by":"publisher","DOI":"10.7937\/ERZ5-QZ59","type":"journal-article","article-title":"Cervical cancer\u2013tumor heterogeneity: serial functional and molecular imaging across the radiation therapy course in advanced cervical cancer (cc-tumor-heterogeneity)","author":"Mayr","year":"2023"},{"key":"pmbae077ebib42","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac1ef2","type":"journal-article","article-title":"Toward MR-integrated proton therapy: modeling the potential benefits for liver tumors","volume":"66","author":"Moteabbed","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib43","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1109\/83.931102","type":"journal-article","article-title":"Topology preserving deformable image matching using constrained hierarchical parametric models","volume":"10","author":"Musse","year":"2001","journal-title":"IEEE Trans. Image Process."},{"key":"pmbae077ebib44","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/j.ijrobp.2021.05.110","type":"journal-article","article-title":"Proton therapy for breast cancer: a consensus statement from the particle therapy cooperative group breast cancer subcommittee","volume":"111","author":"Mutter","year":"2021","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbae077ebib45","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2023.1112481","type":"journal-article","article-title":"Intrafraction tumor motion monitoring and dose reconstruction for liver pencil beam scanning proton therapy","volume":"13","author":"Nankali","year":"2023","journal-title":"Front. Oncol."},{"key":"pmbae077ebib46","doi-asserted-by":"publisher","first-page":"24TR01","DOI":"10.1088\/1361-6560\/ad0d8a","type":"journal-article","article-title":"Review and recommendations on deformable image registration uncertainties for radiotherapy applications","volume":"68","author":"Nenoff","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib47","article-title":"Cupy: a numpy-compatible library for NVidia GPU calculations","volume":"vol 151","author":"Nishino","type":"conference-proceedings"},{"key":"pmbae077ebib48","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1109\/TIP.2005.846026","type":"journal-article","article-title":"3-d deformable image registration: a topology preservation scheme based on hierarchical deformation models and interval analysis optimization","volume":"14","author":"Noblet","year":"2005","journal-title":"IEEE Trans. Image Process."},{"key":"pmbae077ebib49","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.media.2006.01.001","type":"journal-article","article-title":"Retrospective evaluation of a topology preserving non-rigid registration method","volume":"10","author":"Noblet","year":"2006","journal-title":"Med. Image Anal."},{"key":"pmbae077ebib50","first-page":"pp 101","type":"conference-proceedings","article-title":"itk-elastix: Medical image registration in python","author":"Ntatsis","year":"2023"},{"key":"pmbae077ebib51","doi-asserted-by":"publisher","first-page":"101","DOI":"10.3857\/roj.2017.00325","type":"journal-article","article-title":"Deformable image registration in radiation therapy","volume":"35","author":"Oh","year":"2017","journal-title":"Radiat. Oncol. J."},{"key":"pmbae077ebib52","doi-asserted-by":"publisher","first-page":"9186","DOI":"10.1038\/s41467-024-53387-y","type":"journal-article","article-title":"LLM-driven multimodal target volume contouring in radiation oncology","volume":"15","author":"Oh","year":"2024","journal-title":"Nat. Commun."},{"key":"pmbae077ebib53","first-page":"pp 426","type":"conference-proceedings","article-title":"Two-dimensional Chebyshev polynomials for image fusion","author":"Omar","year":"2010"},{"key":"pmbae077ebib54","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20160667","type":"journal-article","article-title":"The future of image-guided radiotherapy will be MR guided","volume":"90","author":"Pollard","year":"2017","journal-title":"Br. J. Radiol."},{"key":"pmbae077ebib55","doi-asserted-by":"publisher","first-page":"10TR01","DOI":"10.1088\/1361-6560\/accdb2","type":"journal-article","article-title":"Online adaptive planning methods for intensity-modulated radiotherapy","volume":"68","author":"Qiu","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib56","doi-asserted-by":"publisher","first-page":"213","DOI":"10.3389\/fonc.2020.00213","type":"journal-article","article-title":"Upright radiation therapy-a historical reflection and opportunities for future applications","volume":"10","author":"Rahim","year":"2020","journal-title":"Front. Oncol."},{"key":"pmbae077ebib57","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1109\/42.929618","type":"journal-article","article-title":"Landmark-based elastic registration using approximating thin-plate splines","volume":"20","author":"Rohr","year":"2001","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae077ebib58","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1109\/42.796284","type":"journal-article","article-title":"Nonrigid registration using free-form deformations: application to breast MR images","volume":"18","author":"Rueckert","year":"2002","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae077ebib59","doi-asserted-by":"publisher","first-page":"23LT01","DOI":"10.1088\/1361-6560\/aaece8","type":"journal-article","article-title":"Integrating a low-field open MR scanner with a static proton research beam line: proof of concept","volume":"63","author":"Schellhammer","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib60","author":"Shah","year":"2022","type":"book"},{"key":"pmbae077ebib61","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/abf9e6","type":"journal-article","article-title":"A generalized framework for analytic regularization of uniform cubic b-spline displacement fields","volume":"7","author":"Shah","year":"2021","journal-title":"Biomed. Phys. Eng. Express"},{"key":"pmbae077ebib62","article-title":"Improving deformable image registration accuracy through a hybrid similarity metric and cyclegan based auto-segmentation","author":"Shah","year":"2024","type":"preprint"},{"key":"pmbae077ebib63","doi-asserted-by":"publisher","first-page":"50","DOI":"10.3389\/fninf.2013.00050","type":"journal-article","article-title":"Marius staring and Alzheimer\u2019s disease neuroimaging initiative. Fast parallel image registration on CPU and GPU for diagnostic classification of Alzheimer\u2019s disease","volume":"7","author":"Shamonin","year":"2014","journal-title":"Front. Neuroinform."},{"key":"pmbae077ebib64","first-page":"2024","type":"other","article-title":"Breast imaging with an ultra-low field MRI scanner: a pilot study","author":"Sheng","year":"2024"},{"key":"pmbae077ebib65","doi-asserted-by":"publisher","DOI":"10.1148\/rg.230073","type":"journal-article","article-title":"Low-field-strength body MRI: challenges and opportunities at 0.55 t","volume":"43","author":"Shetty","year":"2023","journal-title":"RadioGraphics"},{"key":"pmbae077ebib66","article-title":"Accelerating low-field MRI: compressed sensing and ai for fast noise-robust imaging","author":"Shimron","year":"2024","type":"preprint"},{"key":"pmbae077ebib67","doi-asserted-by":"publisher","first-page":"1477","DOI":"10.1088\/0031-9155\/57\/6\/1477","type":"journal-article","article-title":"Analytic regularization for landmark-based image registration","volume":"57","author":"Shusharina","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbae077ebib68","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCIMAGING.117.005446","type":"journal-article","article-title":"Low-field cardiac magnetic resonance imaging: a compelling case for cardiac magnetic resonance\u2019s future","volume":"10","author":"Simonetti","year":"2017","journal-title":"Circulation"},{"key":"pmbae077ebib69","author":"Trefethen","year":"2019","type":"book"},{"key":"pmbae077ebib70","doi-asserted-by":"publisher","first-page":"e401","DOI":"10.1016\/j.prro.2015.01.011","type":"journal-article","article-title":"Utility and validation of biomechanical deformable image registration in low-contrast images","volume":"5","author":"Velec","year":"2015","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbae077ebib71","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.930850","type":"journal-article","article-title":"Considerations for upright particle therapy patient positioning and associated image guidance","volume":"12","author":"Volz","year":"2022","journal-title":"Front. Oncol."},{"key":"pmbae077ebib72","article-title":"Systems and methods for patient positioning during radiotherapy","author":"Yan","year":"2023","type":"other"},{"key":"pmbae077ebib73","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1002\/mp.15409","type":"journal-article","article-title":"Does the greater power of pencil beam scanning reduce the need for a proton gantry? a study of head-and-neck and brain tumors","volume":"49","author":"Yan","year":"2022","journal-title":"Med. Phys."},{"key":"pmbae077ebib74","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.ijrobp.2015.09.033","type":"journal-article","article-title":"Reassessment of the necessity of the proton gantry: analysis of beam orientations from 4332 treatments at the Massachusetts general hospital proton center over the past 10 years","volume":"95","author":"Yan","year":"2016","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbae077ebib75","doi-asserted-by":"publisher","first-page":"e245","DOI":"10.1016\/S1470-2045(23)00184-5","type":"journal-article","article-title":"Global democratisation of proton radiotherapy","volume":"24","author":"Yan","year":"2023","journal-title":"Lancet Oncol."},{"key":"pmbae077ebib76","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.mri.2023.12.012","type":"journal-article","article-title":"On retrospective k-space subsampling schemes for deep MRI reconstruction","volume":"107","author":"Yiasemis","year":"2024","journal-title":"Magn. Reson. Imaging"},{"key":"pmbae077ebib77","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1002\/mrm.20458","type":"journal-article","article-title":"Reduced field-of-view MRI with two-dimensional spatially-selective RF excitation and unfold","volume":"53","author":"Zhao","year":"2005","journal-title":"Magn. Reson. Med."},{"key":"pmbae077ebib78","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1002\/mrm.20983","type":"journal-article","article-title":"Targeted-haste imaging with automated device tracking for MR-guided needle interventions in closed-bore MR systems","volume":"56","author":"Zimmermann","year":"2006","journal-title":"Magn. Reson. Med."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T09:12:00Z","timestamp":1759223520000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae077e"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,30]]},"references-count":78,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2025,9,30]]},"published-print":{"date-parts":[[2025,10,5]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae077e","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,30]]},"assertion":[{"value":"Chebyshev-polynomial-based deformable registration of magnetic resonance images with a specific application in adaptive gantry-less proton therapy","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-04-12","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-09-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-09-30","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}